Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (87)
- Posterpräsentation (23)
- Vortrag (19)
- Beitrag zu einem Tagungsband (18)
- Sonstiges (8)
- Beitrag zu einem Sammelband (3)
- Forschungsbericht (3)
Schlagworte
- Boden (12)
- Eignungsprüfung (9)
- Interlaboratory comparison (9)
- MKW (9)
- Soil (9)
- Proficiency testing (8)
- Gesamtcyanid (7)
- PAK (7)
- Spurenelemente (7)
- Gas chromatography (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (24)
- 1.7 Organische Spuren- und Lebensmittelanalytik (24)
- 6 Materialchemie (6)
- 4 Material und Umwelt (5)
- 6.6 Physik und chemische Analytik der Polymere (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 1.4 Prozessanalytik (2)
- 1.6 Anorganische Referenzmaterialien (2)
- 4.0 Abteilungsleitung und andere (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (19)
An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted.
The binding affinities of the six main hexabromocyclododecane (HBCD) stereoisomers and all of their possible 48 allylic pentabromocyclododecene (PBCD) metabolites to the endocrinous human transthyretin receptor (hTTR) were investigated and compared to the natural binder thyroxine, and the two brominated diphenyl ethers BDE-47 and 3-hydroxy-BDE-47. The endocrine disrupting potency was approximated by a combination of two methods: a surface matching with the natural binder thyroxine (T4) followed by approximation of free binding energies for various binding modes within hTTR. The results indicate slightly higher binding affinities for both BDE structures than for T4 itself and similarly high affinities for two trans-configurated PBCD isomers. For many other PBCD isomers, intermediate values were computed, whereas all HBCD diastereomers yielded significantly lower binding affinities.
In this paper, we investigate the interconversion processes of the major flame retardant - 1,2,5,6,9,10-hexabromocyclododecane (HBCD) - by the means of statistical thermodynamics based on classical force-fields. Three ideas will be presented. First, the application of classical hybrid Monte-Carlo simulations for quantum mechanical processes will be justified. Second, the problem of insufficient convergence properties of hybrid Monte-Carlo methods for the generation of low temperature canonical ensembles will be solved by an interpolation approach. Furthermore, it will be shown how free energy differences can be used for a rate matrix computation. The results of our numerical simulations will be compared to experimental results.
Phosphorus recycling from sewage sludge will be obligatory in Germany from 2029. Phosphorus content determination in sewage sludge is crucial to assess the prescribed recycling rates. Currently, German law regards sample preparation using aqua regia digestion in a microwave or under reflux conditions as well as instrumental phosphorus determination by ICP-OES, ICP-MS, or photometric determination with ammonium molybdate as equivalent. However, it is questionable whether these methods are indeed equivalent regarding phosphorus quantification in sludges near the limit of 20 g/kg for mandatory recycling. To answer this question, 15 sewage sludges of 11 different wastewater treatment plants were investigated with all permitted method (digestion and measurement) combinations. Moreover, one sewage sludge was also examined in an interlaboratory comparison (ILC) with 28 participants. This study shows that the above-mentioned methods differ in some cases significantly but across all method combinations and sludges, phosphorus recovery was between 80 and 121% after normalization to the grand mean (average of 15 sludges between 85 and 111%). The ILC and the examination of 15 sludges produced largely similar results. There is a tendency to higher phosphorus recovery after microwave digestion compared to reflux digestion and ICP-OES measurements determine higher phosphorus contents than ICP-MS and photometric phosphorus determination. As a result, the authors recommend ICP-OES determination of phosphorus in sewage sludge after microwave digestion.
Ziel der vorliegenden Untersuchungen, die im Rahmen einer Diplomarbeit der Fachhochschule Lausitz/Senftenberg an der BAM durchgeführt wurden, war ein Vergleich unterschiedlicher Extraktionsverfahren für die Bestimmung von extrahierbarem organischem Halogen (EOX) in Bodenproben. EOX ist ein für die rasche Bewertung der Organochlor- Belastung kontaminationsverdächtiger Flächen wertvoller Summenparameter, der sämtliche mit organischen Lösungsmittel extrahierbare Organohalogenverbindungen erfasst. Gegenwärtig existiert jedoch kein für die Bodenanalytik genormtes Verfahren für die Durchführung von EOX-Bestimmungen. Daher wird in der Praxis auf das für Schlämme und Sedimente entwickelte Verfahren nach DIN 38414 S17 (1990) zurückgegriffen, so auch in der Bundesbodenschutz- und Altlasten-Verordung (BBodSchV). Literaturangaben und Erfahrungen mit der Wiederfindungsrate polarer Extraktionsmittel und moderner Extraktionsverfahren bei Organochlorpestiziden, die eine bedeutende Quelle für EOX in Schlämmen und Böden darstellen, lassen vermuten, dass das genannte Normverfahren systematisch zu Unterbefunden neigen könnte. Für die Untersuchungen wurden an der BAM entwickelte Boden-Referenzmaterialien mit "natürlicher", über jahrzehntelangen Eintrag entstandener DDT- und Lindan-Belastung verwendet. Neben den klassischen Extraktionsverfahren nach Soxhlet kamen die ultraschallunterstützte Extraktion, die Mikrowellen- und die beschleunigte Lösungsmittelextraktion (ASE) jeweils mit Lösungsmitteln unterschiedlicher Polarität zum Einsatz. Extraktionsausbeuten und Wiederholpräzision der einzelnen Varianten wurden verglichen und vor dem Hintergrund der Ergebnisse unabhängiger Verfahren wie der gaschromatographischen Bestimmung der einzelnen Organochlorverbindungen bewertet. Die Polarität des Extraktionsmittels weist auch bei trockenen Böden den größten Einfluss auf die Extraktionsausbeuten der in den untersuchten Proben enthaltenen Organochlorverbindungen auf. Die Mischung Hexan/Aceton (1:1), die sich für die Extraktion verschiedener organischer Parameter bewährt hat, ist hinsichtlich der EOX-Analytik der existierenden Norm überlegen.
Polyether and -ester urethanes (PU) were exposed to artificial weathering at 40 °C and artificial UV radiation in a weathering chamber. In 3 parallel exposures, humidity was varied between dry, humid, and wet conditions. Material alteration was investigated by various analytical techniques like size exclusion chromatography
(SEC), liquid chromatography-infrared spectroscopy (LC-FTIR), thermal-desorption gas chromatography-mass spectrometry (TD-GC-MS), fluorescence mapping and dynamic mechanical analysis (DMA). Our results show that depending on the weathering conditions, different degradation effects can be observed. By means of SEC an initial strong decrease of the molar masses and a broadening of the mass distributions was found. After a material dependent time span this was followed by a plateau where molar mass changes were less significant. A minor moisture-dependent degradation effect was only found for polyester PU. Fluorescence measurements on two materials revealed an increase in the luminescence intensity upon weathering process reaching a saturation level after about 500 h. The changes in the optical properties observed after different exposure conditions and times were very similar. The TD-GC-MS data showed the fate of the stabilizers and antioxidant in the course of weathering. LC-FTIR measurements revealed a change in peak intensities and the ratio of urethane and carbonyl bands.
This article describes a simple and quick in silico method for the prediction of cytochrome P450 (CYP)-mediated hydroxylation of drug-like compounds. Testosterone and progesterone, two known substrates of CYP3A4, are used to test the method. Further, we apply the procedure to predict sites of hydroxylation of isomers of the flame retardant hexabromocyclododecane by CYP3A4. Within the method, the compound is rotated in the binding pocket of the cytochrome, so that each hydrogen under consideration is placed near the active centre. Afterwards, short molecular dynamics simulations are provided for each step of the rotation. All steps of the simulation are compared concerning the distances between the hydrogens and the active centre and the corresponding energies. The computational results correlate well with experimental results.
The resource-saving utilisation of recovered
waste wood is a matter of growing concern. In several
European countries, this utilisation is governed by regulations
and is dependent on the contents of certain trace
elements and organic compounds. Thus, for decisionmaking
with respect to waste wood management (recycling
or combustion), reliable analytical data are needed and, due
to their great economic and environmental impact, must be
assured by appropriate quality control. To support the
improvement in quality assurance in waste wood analysis,
for the first time, a wood reference material was certified
for its mass fractions of arsenic, cadmium, chromium,
copper, lead, mercury, and pentachlorophenol (PCP).
These analytes were selected because they represent typical
constituents of wood preservatives most widely used in the
past. Material preparation and testing of homogeneity and
stability were carried out by BAM Federal Institute for
Materials Research and Testing. The certification measurements
were performed involving selected laboratories
with documented expertise in the field of waste wood
analysis. The certified values and their corresponding
uncertainties were assigned in full compliance with the
requirements of ISO Guide 35. The certified mass fractions
and their expanded uncertainties (k/i> = 2) are as follows:
(3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd,
(36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu,
(0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and
(7.9 ± 0.6) mg/kg for PCP. The certified material is
available as European Reference Material ERM®-CD100.
In vitro cultured lung cancer cells are not suitable for animal-based breath biomarker detection
(2015)
In vitro cultured lung cancer cell lines were investigated regarding the possible identification of volatile organic compounds as potential biomarkers. Gas samples from the headspace of pure culture medium and from the cultures of human lung adenocarcinoma cell lines A549 and Lu7466 were exposed to polypropylene fleece in order to absorb odour components. Sniffer dogs were trained with loaded fleeces of both cell lines, and honey bees were trained with fleeces exposed to A549. Afterwards, their ability to distinguish between cell-free culture medium odour and lung cancer cell odour was tested. Neither bees nor dogs were able to discriminate between odours from the cancer cell cultures and the pure culture medium. Solid phase micro extraction followed by gas chromatography with mass selective detection produced profiles of volatiles from the headspace offered to the animals. The profiles from the cell lines were largely similar; distinct differences were based on the decrease of volatile culture medium components due to the cells' metabolic activity. In summary, cultured lung cancer cell lines do not produce any biomarkers recognizable by animals or gas chromatographic analysis.
Three strategies to sample volatile organic compounds (VOC) from lung cancer cell lines cultured in vitro were compared. Headspace solid phase microextraction was applied in situ to culture flasks and alternatively to subsamples of headspace gas or to nutrient solution subsamples followed by gas chromatography–mass spectrometry. The direct quantification of 55 VOC in the headspace of cell cultures was validated and is discussed with respect to reproducibility and system-related interferences. The role of the VOC background from culture media and usually employed polystyrene culture vessels is examined and was seen to invoke potentially misleading conclusions. The commercial A549 and two further adenocarcinoma cell lines displayed largely similar VOC profiles with distinct differences regarding certain individual substances. There is evidence for the inappropriateness of the standard cell culturing methods in the search for volatile cancer markers.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden.
Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden.
The development of a test to evaluate the degradation of semi-volatile fuels as diesel by microorganisms is presented. This method is based on the principles described in the CEC-L-103 Standard procedure that is exclusively meant for testing the biodegradability of non-volatile lubricants. Therefore, significant modifications involve aseptic conditions for testing specific microorganisms and conducting the test in closed vessels avoiding evaporation losses, while fuel quantification using gas chromatography-flame ionization detection (GC-FID) is retained. It is suggested that the modified procedure should enable routine application for semi-volatile hydrocarbon-based fuels. GC-FID provides additionally valuable information on the alteration of fuel component patterns during biodegradation. The procedure was successfully tested using two bacteria (Pseudomonas aeruginosa and Sphingomonas sp.) and two yeasts (Moesziomyces sp. and Candida sp.) isolated from real diesel contamination cases. All tested microorganisms caused a significant degradation of diesel fuel achieving hydrocarbon degradation percentages ranging from 23% to 35%. Specific aspects on the test modification and prospects for further modification regarding targeted investigations in the field of fuel contamination by microorganisms are briefly discussed.
Technical 1,2,5,6,9,10-hexabromocyclododecane (HBCD) consists largely of three diastereomers (α-, β-, and γ-HBCD) produced by the trans addition of bromine to cis,trans,trans-cyclododeca-1,5,9-triene (CDT). However, another seven diastereomers are theoretically possible and may be produced by trans addition of bromine across the double bonds of the other three isomers of 1,5,9-CDT. There are indications that small amounts of the minor HBCD isomers may be present in commercial HBCD mixtures or in products containing this brominated flame retardant (BFR). Such minor components may indeed derive from traces of other 1,5,9-CDTs in the cis, trans, trans starting material, however their formation may also be possible through isomerizations during the processing of this BFR or by bioisomerization subsequent to its release into the environment. Two of the seven additional diastereomers (δ- and ε-HBCD) were synthesized previously from trans,trans,trans-CDT. We now report the preparation of the remaining five diastereomers, ζ-, η-, and θ-HBCD from cis,cis,trans-CDT and ι- and κ-HBCD from cis,cis,cis-CDT, and their characterization by 1H NMR spectroscopy and X-ray crystallography. The availability of these further diastereomers of HBCD should aid in determining if the minor isomers are present in commercial samples of this BFR, in products containing HBCDs, or in environmental samples. We have also carried out an X-ray crystal structure determination on ε-HBCD, so that crystal structures are now available for all 10 HBCD diastereomers.
The key comparison CCQM-K102: Polybrominated diphenyl ethers in sediment was coordinated by the JRC, Directorate F - Health, Consumers & Reference Materials, Geel (Belgium) under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM). Thirteen National Metrology institutes or Designated Institutes and the JRC participated. Participants were requested to report the mass fraction (on a dry mass basis) of BDE 47, 99 and 153 in the freshwater sediment study material. The sediment originated from a river in Belgium and contained PBDEs (and other pollutants) at levels commonly found in environmental samples. The comparison was designed to demonstrate participants' capability of analysing non-polar organic molecules in abiotic dried matrices (approximate range of molecular weights: 100 to 800 g/mol, polarity corresponding to pKow < −2, range of mass fraction: 1–1000 μg/kg). All participants (except one using ultrasonic extraction) applied Pressurised Liquid Extraction or Soxhlet, while the instrumental analysis was performed with GC-MS/MS, GC-MS or GC-HRMS. Isotope Dilution Mass Spectrometry approach was used for quantification (except in one case). The assigned Key Comparison Reference Values (KCRVs) were the medians of thirteen results for BDE 47 and eleven results for BDE 99 and 153, respectively. BDE 47 was assigned a KCRV of 15.60 μg/kg with a combined standard uncertainty of 0.41 μg/kg, BDE 99 was assigned a KCRV of 33.69 μg/kg with a combined standard uncertainty of 0.81 μg/kg and BDE 153 was assigned a KCRV of 6.28 μg/kg with a combined standard uncertainty of 0.28 μg/kg. The k-factor for the estimation of the expanded uncertainty of the KCRVs was chosen as k = 2.
Zinc dialkyl dithiocarbamoylsulfinates have been proposed as intermediates in the antioxidant action of the respective zinc dialkyl dithiocarbamate additives in hydrocarbon-based plastics and lubricants. As a model compound, zinc diisobutyl dithiocarbamoylsulfinate, [Zn(C9H18NO2S2)2], has been prepared and its crystal structure determined.
Bis(N,N-di-n-butyldithiocarbamato-?2S,S')(1,10-phenanthroline-?2N,N')zinc(II) ethanol hemisolvate, [Zn(C9H18NS2)2(C12H8N2)]·0.5C2H6O, (I), and bis(N,N-di-n-hexyldithiocarbamato-?2S,S')bis(1,10-phenanthroline-?2N,N')calcium(II), [Ca(C13H26NS2)2(C12H8N2)2], (II), are mixed-ligand complexes. In the first compound, the Zn atom has a distorted octahedral coordination, while in the second compound, the Ca atom is eight-coordinate, with four S and four N atoms forming a highly distorted cube.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris leads to the accumulation of microscopic plastic particles of still unknown amount. To monitor the degree of contamination analytical methods are urgently needed, which help to quantify microplastics (MP). Currently, time-costly purified materials enriched on filters are investigated both by micro-infrared spectroscopy and/or micro-Raman. Although yielding precise results, these techniques are time consuming, and are restricted to the analysis of a small part of the sample in the order of few micrograms. To overcome these problems, here we tested a macroscopic dimensioned NIR process-spectroscopic method in combination with chemometrics. For calibration, artificial MP/soil mixtures containing defined ratios of polyethylene, polyethylene terephthalate, polypropylene, and polystyrene with diameters < 125 µm were prepared and measured by a process FT-NIR spectrometer equipped with a fiber optic reflection probe. The resulting spectra were processed by chemometric models including support vector machine regression (SVR), and partial least squares discriminant analysis (PLS-DA). Validation of models by MP mixtures, MP-free soils and real-world samples, e.g. and fermenter residue, suggest a reliable detection and a possible classification of MP at levels above 0.5 to 1.0 mass% depending on the polymer. The benefit of the combined NIRS chemometric approach lies in the rapid assessment whether soil contains MP, without any chemical pre-treatment. The method can be used with larger sample volumes and even allows for an online prediction and thus meets the demand of a high-throughput method.
Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis.
This paper describes Food-MetNet, a coordinated preparatory initiative to establish the European Metrology Network on Food Safety (EMN-FS). Food-MetNet aims to establish a long-term ongoing dialogue between the metrology community and relevant stakeholders, in particular, European Union Reference Laboratories (EURLs), National Reference Laboratories (NRLs) and the Joint Research Centre (JRC). This dialogue is meant to support the collection of needs from stakeholders, the take-up of metrological research output and the development of the roadmaps needed to navigate future research.
Wie viele Forschergruppen, haben auch wir uns das langfristige Ziel gesetzt, einen Beitrag bei der Beantwortung der Frage zu leisten, was Hunde riechen, wenn sie Krebs erschnüffeln.
Dabei sollen die Hunde nicht nur anzeigen, ob eine Atemluftprobe positiv oder negativ ist, sondern sie sollen auch aktiv eingebunden werden in den systematischen Suchprozess nach detektierbaren Biomarkern. So ist geplant, dass mittels eines präparativen Fraktionssammlers definierte Schnitte des Gaschromatogramms einzeln oder in möglichen Kombinationen auf das Adsorbervlies gebracht werden, um im Hundetraining eingesetzt zu werden. In analoger Weise könnte auch mit spezifischen Kandidatensubstanzen verfahren werden.
The title compound, {2-[(2-carbamoylethyl)amino]-3-methylpentanoic acid}, C9H18N2O3, is of interest with respect to its biological activity. It was formed during an addition reaction between acrylamide and the amino acid isoleucine. The crystal structure is a three-dimensional network built up by intermolecular N–H···O and O–H···N hydrogen bonds.
Die Präsenz von Mikroplastik in aquatischen Ökosystemen ist ein globales Problem und steht zunehmend im Fokus der Öffentlichkeit. In mehreren Studien konnten Anreicherungen hydrophober, organischer Schadstoffe an MP nachgewiesen werden. Der Einfluss des Alterungszustandes der MP-Partikel auf das Sorptionsverhalten von hydrophoben organischen Substanzen ist nicht hinreichend geklärt.
Ziel der vorliegenden Arbeit war die Untersuchung des Sorptionsverhaltens von Schadstoffen mit Bedeutung für limnische Gewässer an künstlich gealterten Partikeln relevanter Polymere. Das Modell verwendete die Aromaten Benzol, Toluol, Ethylbenzol und Xylol (BTEX) sowie Etherverbindungen. Diese Substanzen sind oder waren Bestandteile in unterschiedlichen Kraftstoffen und finden sich daher in vielen aquatischen Ökosystemen weltweit. Als Sorbentien kamen teilkristallines Polypropylen (PP) und amorphes Polystyrol (PS) in Form von Industriepellets zum Einsatz. Die Pellets wurden jeweils sowohl unbehandelt als auch mittels UV-Bestrahlung künstlich gealtert verwendet und mikroskopisch sowie mittels XPS, FTIR und DSC charakterisiert. Die Alterung führte bei PS zu einer verringerten Sorptionskapazität, während bei PP keine Veränderung im Sorptionsverhalten beobachtet wurde.
The title compound [systematic name: (2R,3R,4S,5R,6R) 2-(acetoxymethyl)-6-propoxytetrahydro-2H-pyran-3,4,5-triyl triacetate], C17H26O10, was formed by a Koenigs-Knorr reaction of 2,3,4,6-tetra-O-acetyl-α-D-glucopyranosyl bromide and n-propanol. The central ring adopts a chair conformation. The crystal does not contain any significant interactions such as hydrogen bonds.
Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 1030 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 23 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values.
A combination of simultaneous milling and extraction known as micropulverized extraction was developed for the quantification of the alcohol marker ethyl glucuronide (EtG) in hair samples using a homogeneous reference material and a mixer mill. Best extraction results from 50 mg of hair were obtained with 2-mL plastic tubes containing two steel balls (Ø = 5 mm), 0.5 mL of water and with an oscillating frequency of 30 s-1 over a period of 30 min. EtG was quantified employing a validated GC-MS procedure involving derivatization with pentafluoropropionic acid anhydride. This micropulverization procedure was compared with dry milling followed by separate aqueous extraction and with aqueous extraction after manual cutting to millimeter-size snippets. Micropulverization yielded 28.0±1.70 pg/mg and was seen to be superior to manually cutting (23.0±0.83 pg/mg) and equivalent to dry grinding (27.7±1.71 pg/mg) with regard to completeness of EtG extraction. The option to process up to 20 samples simultaneously makes micropulverization especially valuable for the high throughput of urgent samples.
The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment.
Microplastics are increasingly entering marine, limnic and terrestrial ecosystems worldwide, where they sorb hydrophobic organic contaminants. Here, the sorption behavior of the fuel-related water contaminants benzene, toluene, ethyl benzene and xylene (BTEX) and four tertiary butyl ethers to virgin and via UV radiation aged polypropylene (PP) and polystyrene (PS) pellets was investigated. Changes in material properties due to aging were recorded using appropriate polymer characterization methods, such as differential scanning calorimetry, Fourier transform infrared spectroscopy, gel permeation chromatography, X-ray photoelectron spectroscopy, and microscopy.
Pellets were exposed to water containing BTEX and the ethers at 130-190 mg/L for up to two weeks.
Aqueous sorbate concentrations were determined by headspace gas chromatography. Sorption to the polymers was correlated with the sorbate's Kow and was significant for BTEX and marginal for the ethers.
Due to substantially lower glass transition temperatures, PP showed higher sorption than PS. Aging had no effect on the sorption behavior of PP. PS sorbed less BTEX after aging due to an oxidized surface layer.
The ecotoxicological characterization of waste is part of its assessment as hazardous or non-hazardous according to the European Waste List. For this classification 15 hazard criteria are derived from the Council Directive 91/689/EEC on hazardous waste. Some of the hazard criteria are based on the content of dangerous substances. The criterion H14 'ecotoxic' lacks of an assessment and testing strategy and no specific threshold values have been defined so far. Based on the recommendations of CEN guideline 14735 (2005), an international round robin test (ring test) was organized by the German Federal Environment Agency in order to define suitable test methods for the biological assessment of waste and waste eluates. A basic test battery, consisting of three aquatic and three terrestrial tests, was compiled. In addition, data were submitted for ten additional tests (five aquatic (including a genotoxicity test) and five terrestrial ones). The tests were performed with three representative waste types: an ash from an incineration plant, a soil containing high concentrations of organic contaminants (polycyclic aromatic hydrocarbons) and a preserved wood waste. The results of this ring test confirm that a combination of a battery of biological tests and chemical residual analysis is needed for an ecotoxicological characterization of wastes. With small modifications the basic test battery is considered to be well suitable for the hazard and risk assessment of wastes and waste eluates. All results and documents are accessible via a web-based data bank application.
The statistical tool eCerto was developed for the evaluation of measurement data to assign property values and associated uncertainties of reference materials. The analysis is based on collaborative studies of expert laboratories and was implemented using the R software environment. Emphasis was put on comparability of eCerto with SoftCRM, a statistical tool based on the certification strategy of the former Community Bureau of Reference. Additionally, special attention was directed towards easy usability from data collection through processing, archiving, and reporting. While the effects of outlier removal can be flexibly explored, eCerto always retains the original data set and any manipulation such as outlier removal is (graphically and tabularly) documented adequately in the report. As a major reference materials producer, the Bundesanstalt für Materialforschung und -prüfung (BAM) developed and will maintain a tool to meet the needs of modern data processing, documentation requirements, and emerging fields of RM activity. The main features of eCerto are discussed using previously certified reference materials.
Delta-Hexabromocyclododecane
(2007)
Decabromodiphenylethane
(2007)
Decabromodiphenylethane [systematic name: 1,1'-ethane-1,2-diylbis(pentabromobenzene)], C14H4Br10 (DBDPE), was crystallized from toluene. The molecule shows crystallographic inversion symmetry. The CBr distances are in the range 1.873 (7)1.891 (6) Å; intermolecular BrBr contacts contribute to the formation of ribbons.
A method for the determination of the novel brominated flame retardant tetrabromobisphenol A bis(2,3-dibromopropylether), 1,1'-(isopropylidene)bis[3,5-dibromo-4-(2,3-dibromo-propoxy)-benzene] (TBBPA-dbpe), was developed. Technical TBBPA-dbpe was purified and the results of a thorough physical characterisation are reported. The application of APCI-MS is discussed and the fragmentation patterns are described. Quantification of TBBPA-dbpe was done by HPLC-DAD using external calibration. The validation of the method was accomplished using sediment and sewage sludge samples spiked with defined amounts of authentic TBBPA-dbpe. The average recovery rates of TBBPA-dbpe from spiked samples ranged from 35 to 91% (sediment) and from 57 to 98% (sewage sludge) depending on the respective extraction method. Pressurised fluid extraction (PFE) and fluidised bed extraction were superior to classical Soxhlet and sonication procedures and yielded recovery rates between 90 and 98% with relative standard deviations of 2%. The limits of detection (DTC), identification (ID) and determination (DTM) using HPLC-DAD were 10, 21 and 30 ng g-1 in sediment and 22, 44 and 72 ng g-1 in sewage sludge, respectively.
The interconversion of the stereoisomers contained in technical 1,2,5,6,9,10-hexabromocyclododecane, a major brominated flame retardant increasingly found in the environment and in biota, was investigated at elevated temperatures. The application of pure enantiomers of the three constituents α-, β-, and γ-HBCD enabled the unambiguous elucidation of the individual isomerisation reactions as well as the quantification of all respective rate constants. At 160 °C the rate constants range over two orders of magnitude from 1.50 × 10-3 to 1.88 × 10-5 mol(%) s-1. A preliminary mechanistic explanation for the differences of the rate constants which govern the composition of HBCD diastereomers at equilibrium is given.
High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments.
1,2,5,6,9,10-Hexabromocyclododecane (HBCD) is a widely used flame retardant, which tends to persist in the environment and accumulates in biota. The six stereoisomers (three racemates named α-, β-, and γ-HBCD) of the technical mixture were isolated with high-performance liquid chromatography (HPLC). Direct separations were performed on a chiral stationary phase containing permethylated -cyclodextrin (NUCLEODEX -PM column) and the pure enantiomers of α-, β-, and γ-HBCD were physically characterized for the first time. The absolute configurations of all six isomers were determined by anomalous dispersion using single crystal X-ray crystallography. Optical rotations αD in tetrahydrofuran were +4.2/-4.0 (α-HBCD), +26.1/-27.5 (β-HBCD), and +68.0/-66.3 (γ-HBCD). The sense of rotation could be correlated with the absolute configurations of α-, β-, and γ-HBCD enantiomers and their order of elution on a chiral permethylated β-cyclodextrin-bonded stationary phase. The diastereomers α-, β-, and γ-HBCD displayed distinctly different melting points as well as 1H-, 13C NMR, and IR spectra.
Certified reference materials for organic contaminants in sewage sludge - a feasibility study
(2008)
As an answer to the re-evaluation of the European sludge directive, two novel reference materials for organic components in municipal sludge have been produced and test certified for AOX (absorbable organic halogens), PAH (polycyclic aromatic hydrocarbons), NPE (nonylphenol and nonylphenolethoxylates), DEHP (di(2-ethylhexyl)phthalate), bisphenol A, and BFR (brominated flame retardants). The materials were prepared from raw sludge without spiking or mixing of different sludges. The study demonstrated that the technique for the preparation of a suitable reference material, sufficiently homogenous and stable, and with concentration levels that answer the needs of the laboratories and the relevant authorities, can now be presented in detail. The results, furthermore, show there is a need for method validation and standardisation of the measurements of NPEs and certain BFR congeners, and that the development of the laboratory structure in Europe, with fewer and more specialised laboratories, might become a major obstacle when trying to find a sufficient number of laboratories being appropriately proficient for this kind of study in the future.
On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.
A Proof of Concept: Are Detection Dogs a Useful Tool to Verify Potential Biomarkers for Lung Cancer?
(2018)
Early and reliable diagnostic test is essential for effective therapy of lung cancer. Volatile organic compounds that are characteristic for cancer could serve as valuable biomarkers in cancer diagnosis. Both trace analytical and detection dog approaches give some evidence for the existence of such biomarkers. In this proof of concept, study dogs and trace analysis were implemented in combination to gain more information concerning cancer biomarkers. Two dogs were trained to distinguish between absorbed breath samples of lung cancer patients and healthy persons and succeeded with correct identification of patients with 9/9 and 8/9 and correct negative indications from of 8/10 and 4/10 samples from healthy individuals. A recent observational study found that breath samples from lung cancer patients showed an increase in 1-butanol, 2-butanone, 2-pentanone, and hexanal. Synthetic air samples were therefore fortified with these compounds and adsorbed to a fleece. Tested against breath samples from healthy probands, on presentation to the dogs these synthetic samples provoked an indication in three out of four samples. We were able to demonstrate that a combination of the natural nose of a dog and a trace analytic technique can be a valuable concept in the search for cancer biomarkers.
Odor Perception by Dogs: Evaluating Two Training Approaches for Odor Learning of Sniffer Dogs
(2017)
In this study, a standardized experimental set-up with various combinations of herbs as odor sources was designed. Two training approaches for sniffer dogs were compared; first, Training with a pure reference odor, and second, training with a variety of odor mixtures with the target odor as a common denominator. The ability of the dogs to identify the target odor in a new context was tested. Six different herbs (basil, St. John’s wort, dandelion, marjoram, parsley, ribwort) were chosen to produce reference materials in various mixtures with (positive) and without (negative)chamomile as the target odor source. The dogs were trained to show 1 of 2 different behaviors, 1 for the positive, and 1 for the negative sample as a yes/no task. Tests were double blind with one sample presented at a time. In both training approaches, dogs were able to detect chamomile as the target odor in any presented mixture with an average sensitivity of 72% and a specificity of 84%. Dogs trained with odor mixture containing the target odor had more correct indications in the transfer task.
Enantiomerenspezifischer Vergleich von HBCD-Gehalten maritimer Lebewesen zweier norwegischer Fjorde
(2010)
HBCD isomers: degradation rates and hydroxylated products from microsome incubation experiments
(2010)
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-
HBCD. No evidence for the isomerization of HBCD stereoisomers was observed in Mirror Carp fillets.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
Hexabromocyclododecane enantiomers: microsomal degradation and patterns of hydroxylated metabolites
(2011)
The degradation of the enantiomers of α-, β-, and γ-hexabromocyclododecane (HBCD) by phase I metabolism was investigated using induced rat liver microsomes. HBCD isomers were quantified using HPLC-MS/MS (ESI-) after separation on a combination of a reversed phase and a chiral analytical column. The degradation of all six isomers followed first-order kinetics and the estimated half-lives ranged from 6.3 min for both β-HBCD enantiomers to 32.3 min in case of (+)-γ-HBCD. (+)-α- and (–)-γ-HBCD displayed significantly shorter half-lives than their corresponding antipodes. It could be shown that this degradation led to a significant enrichment of the first eluting enantiomers (–)-α- and (+)-γ-HBCD. Individual patterns of mono- and dihydroxylated derivatives obtained from each α- and γ-HBCD enantiomer were seen to be distinctly characteristic. The patterns of monohydroxylated HBCD derivatives detected in liver and muscle tissues of pollack, mackerel and in herring gull eggs were largely similar to those observed in the in vitro experiments with rat liver microsomes. This enabled individual hydroxy-HBCDs to be assigned to their respective parent HBCD enantiomers.
Time courses of HBCD levels and enantiomeric signatures in herring gull eggs from the German coast
(2010)
Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LCMS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD.
The title compounds Zn2[S2CN(n-C4H9)2]4 1 and Zn2[(S(SO)CN(n-C4H9)2)(S2CN(n-C4H9)2)]2 3 build mixed crystals in the ratio 0.42: 0.58. Each compound forms dimers, in which the monomer moieties are related via a two-fold axis, coinciding with that of the monoclinic space group C2/c. The lattice parameters are a = 23.581(9), b = 17.112(5), c = 16.372(9) Å, and β = 128.33(3)°.
In recent years, an increasing trend towards investigating and monitoring the contamination of the environment by microplastics (MP) (plastic pieces < 5 mm) has been observed worldwide. Nonetheless, a reliable methodology that would facilitate and automate the monitoring of MP is still lacking. With the goal of selecting practical and standardized methods, and considering the challenges in microplastics detection, we present here a critical evaluation of two vibrational spectroscopies, Raman and Fourier transform infrared (FTIR) spectroscopy, and two extraction methods: thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) and liquid extraction with subsequent size exclusion chromatography (SEC) using a soil with known contents of PE, PP, PS and PET as reference material. The obtained results were compared in terms of measurement time, technique handling, detection limits and requirements for sample preparation. The results showed that in designing and selecting the right methodology, the scientific question that determines what needs to be understood is significant, and should be considered carefully prior to analysis. Depending on whether the object of interest is quantification of the MP particles in the sample, or merely a quick estimate of sample contamination with plastics, the appropriate method must be selected. To obtain overall information about MP in environmental samples, the combination of several parallel approaches should be considered.
A novel approach for the simulation of host.guest systems by systematically scanning the host moleculefs orientations within the guest cavity is presented along with a thermodynamic strategy for determining preferential binding modes and corresponding optimal interaction energies between host and guest molecules. By way of example, the elution order of hexabromocyclododecane stereoisomers from high performance liquid chromatography separation on a permethylated β-cyclcodextrin stationary phase has been computed using classical molecular dynamics simulations with the explicit solvents water and acetonitrile. Comparison of estimated with experimental separation data reveals remarkable squared coefficients of correlation with R2=0.87 and a very high correlation RLOO2 . 0:72 using the leaveone-out cross-validation method and water as solvent. In particular, the approach presented shapes up as very robust in terms of the evaluated time range under consideration, reflecting well thermodynamic equilibria. These and further observations correlating with experimental results suggest the suitability of the underlying force fields and our multi-mode approach for the estimation of relative binding affinities for host–guest systems with unknown binding modes.
Im vorliegenden Forschungsbericht werden die Ergebnisse zum LFP Projekt „Ableitung validierter Probenahme- und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von LCKW im Grundwasser im Rahmen von Altlastenuntersuchungen“ (Länderfinanzierungsprogramm, Projekt B2/08, Laufzeit vom 01.09.2008 – 31.08.2009) zusammengefasst. Es werden verschiedene Verfahren der Probenahme und Analytik zur Bestimmung von Wasserstoff, Methan, Ethen und Vinylchlorid (VC) im Grundwasser untersucht und validiert. Für die Probenahme werden folgende Ansätze beschrieben und diskutiert: i. aktive Probenahme: Pumpprobe und Probenahme von in Grundwasser gelösten Gasen in Gasbeprobungsrohren (Gasmaus) ii. passive Probenahme: Diffusionsprobenahme in Polyethylenbeuteln (PDB) und Kunststoffspritzen als Diffusionssammler für gelöste Gase Der Einsatz aktiver (Pumpprobenahme, Schöpfprobenahme) und passiver (Diffusionsprobenahme) Probenahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probenahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probenahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Die chromatographischen Verfahren zur Bestimmung der Analyte werden umfänglich validiert und mit anderen geeigneten Analysenverfahren verglichen: I. Headspace-GC-FID zur Bestimmung von Methan, Ethen und VC aus der wässrigen Probenmatrix der Pumpprobe (i.) und des PDB (ii.) II. Direktinjektion-GC-PDD zur Bestimmung von Wasserstoff aus den gesammelten Gasproben der Gasmaus (i.) und der Kunststoffspritzen (ii.) Für die Bestimmung von Ethen und VC in Grundwasserproben (I.) werden Bestimmungsgrenzen von 0,1 μg/L erreicht. Methan kann aus wässrigen Proben nur ab 5 μg/L quantifiziert werden. Mit den Verfahren zur Bestimmung von Methan aus der Gasmaus (i.-II.) werden 0,1 μg/L im Grundwasser erreicht. Die Bestimmung von im Grundwasser gelösten Wasserstoff (II.) ist bis zu einer Konzentration von 1 nM möglich. Die Reproduzierbarkeit für die Bestimmung von Wasserstoff in Grundwasser liegt konzentrationsabhängig zwischen 10 bis 20% bei der aktiven Probenahme (i.-II.) und 10 bis 70% bei der passiven Probenahme (ii.-II.). Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probenahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring-Ergebnissen sollten von Ingenieurbüros und zuständige Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden.
Als Folge der industriellen Produktion und der vielfältigen industriellen Nutzung von organischen Lösungsmitteln sind eine Vielzahl von Edukten, Zwischen- und Endprodukten in die Umwelt eingetragen worden und führen zu massiven Verunreinigungen des Bodens und des Grundwassers. Die Untersuchung und Sanierung des Grundwassers stellt einen aktuellen Schwerpunkt in der Altlastenbearbeitung dar. Vielfach werden klassische pump & treat-Verfahren zur Grundwassersanierung verwendet. Diese aktiven Sicherungs- und Sanierungsmaßnahmen werden jedoch unter dem Gesichtspunkt der Verhältnismäßigkeit häufig als ineffizient eingeschätzt. Als Alternative sollen die natürlichen Abbauprozesse im Grundwasserleiter genutzt oder gezielt verstärkt werden, um auf diesem Weg eine in-situ-Sanierung des Grundwasserleiters zu erreichen. In den letzten Jahren haben sich verschiedene Sanierungsverfahren etabliert, bei denen durch die Zugabe von Hilfsstoffen die mikrobiologische Aktivität des Aquifers erhöht wird bzw. Stoffe zugeführt werden, die mit den Schadstoffen reagieren (in-situ chemische Oxidation bzw. Reduktion, ISCO). An ausgewählten Standorten ist auch die aktive Sanierung (pump & treat, on-site- Sanierung) mit biologischem Schadstoffabbau (Bio-Filter) kombiniert worden. Um den Sanierungsverlauf zu verfolgen und zu optimieren, ist die Beprobung von Grundwasser aus dem Grundwasserleiter oder aus laufenden Anlagen erforderlich. In Fällen der gesteigerten mikrobiologischen Aktivität des Grundwassers treten gehäuft Probleme bei der Stabilisierung der Wasserproben auf. Die forcierten Abbauprozesse der Schadstoffe gehen nach der Probenahme in der Probenflasche weiter, bis die Energiebasis der Mikrobiologie aufgebraucht ist. Durch eine geringe Temperaturerhöhung beschleunigen sich diese Prozesse zusätzlich. In der Folge können die Schadstoffgehalte teilweise innerhalb weniger Stunden stark reduziert werden. Im Analysenlabor wird dann ein Schadstoffgehalt nachgewiesen, der nicht mehr die Verhältnisse im Aquifer bzw. im Ablauf der Reinigungsstufen widerspiegelt. Eine Einschätzung des Sanierungsfortschritts oder der Reinigungsleistung ist unter diesen Bedingungen stark fehlerbehaftet und kann zu groben Fehlinterpretationen führen. Grundwasserproben, die einem Aquifer mit hoher natürlicher oder initiierter mikrobiologischer Abbauaktivität entstammen, müssen daher zusätzlich stabilisiert werden, um den Ist-Zustand zum Zeitpunkt der Probenahme zu erfassen. Die Konservierung von Wasserproben bei der Probenahme von Grundwasser ist in der Normung umfangreich beschrieben: Die EN ISO 5667-3 von 2004 ist im Normausschuss (NA 119-01-03-01-01) überarbeitet und 2012 als Norm verabschiedet worden (EN ISO 5667-3, 03.12, deutsche Fassung DIN EN ISO 5667-3, 03-2013) [1], In Einzelfällen hat sie sich nicht als ausreichend erwiesen, um die Stabilität der organischen Schadstoffe in den oben beschriebenen Wasserproben zu gewährleisten.
Der Einsatz aktiver (Pumpprobennahme,
Schöpfprobennahme) und passiver (Diffusionsprobennahme)
Probennahmetechniken zur Gehaltsbestimmung von
LHKW sowie Ethen und Methan in Grundwasser wird aus
ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit
von Analysendaten untersucht. Am Beispiel einer Kontamination
mit Trichlorethen sowie 1,2-Dichlorethen und
Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit
der passiven Probennahme durch unzureichende
Strömungsverhältnisse im Aquifer sowie biologische
Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme
ist bei ungeklärten oder unzureichenden Strömungsverhältnissen
im Grundwasserleiter daher der Vorzug
zu geben. Das gaschromatographische Verfahren für Vinylchlorid
mittels Dampfraumtechnik wird um die Quantifizierung
von Methan und Ethen erweitert. Dabei werden für
die Bewertung von Altlasten relevante Bestimmungsgrenzen
von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan)
erreicht.
Aus der Validierung der Analysenmethode und den
Ergebnissen verschiedener Probennahmen werden Toleranzbereiche
für die Ergebnisse eines Grundwassermonitorings
abgeschätzt. Diese Streubreiten von Monitoring-
Ergebnissen sollten von Ingenieurbüros und zuständigen
Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse
eines LHKW-Grundwasserschadens beachtet
werden.
A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM.
Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines.
A practical method for the quantification of
total purgeable organic sulfur (POS) in highly contaminated
groundwater is described. Volatile organic sulfur
compounds (VOSC) are purged from the water samples by
a stream of oxygen and combusted. The emerging sulfur
dioxide is absorbed in H2O2 and converted to sulfate which
is quantified by ion chromatography and reported as mass
sulfur equivalent. The overall limit of quantification is
0.03 mg l1. The content of POS is balanced with the total
VOSC determined by GC-AED after liquidliquid extraction.
Separate determination of the non-volatile organic
sulfur compounds by direct combustion of the water sample
and adsorption to charcoal yielded a mass balance of
the total sulfur content. Semi-quantitative GC-MS after
purge & trap accumulation revealed that the VOSC mixture
is composed of C1C4 alkyl sulfides. The implementation
of the developed methodology for the quantification of
VOSC as potential catalyst poison in a cleaning plant
for groundwater contaminated with volatile haloorganics
(VOX) is presented.
Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed.
The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached.
Evidence for the formation of difluoroacetic acid in chlorofluorocarbon-contaminated ground water
(2019)
The concentrations of difluoroacetic acid (DFA) and trifluoroacetic acid (TFA) in rainwater and surface water from Berlin, Germany resembled those reported for similar urban areas, and the TFA/DFA ratio in rainwater of 10:1 was in accordance with the literature. In contrast, nearby ground water historically contaminated with 1,1,2-trichloro-1,2,2-trifluoroethane (R113) displayed a TFA/DFA ratio of 1:3. This observation is discussed versus the inventory of microbial Degradation products present in this ground water along with the parent R113 itself. A microbial Transformation of chlorotrifluoroethylene (R1113) to DFA so far has not been reported for environmental media, and is suggested based on well-established mammalian metabolic pathways.
Soils are essential components of terrestrial ecosystems that experience strong pollution pressure. Microplastic contamination of soils is being increasingly documented, with potential consequences for soil biodiversity and function. Notwithstanding, data on effects of such contaminants on fundamental properties potentially impacting soil biota are lacking. The present study explores the potential of microplastics to disturb vital relationships between soil and water, as well as its consequences for soil structure and microbial function. During a 5-weeks garden experiment we exposed a loamy sand soil to environmentally relevant nominal concentrations (up to 2%) of four common microplastic types (polyacrylic fibers, polyamide beads, polyester fibers, and polyethylene fragments). Then, we measured bulk density, water holding capacity, hydraulic conductivity, soil aggregation, and microbial activity. Microplastics affected the bulk density, water holding capacity, and the functional relationship between the microbial activity and water stable aggregates. The effects are underestimated if idiosyncrasies of particle type and concentrations are neglected, suggesting that purely qualitative environmental microplastic data might be of limited value for the assessment of effects in soil. If extended to other soils and plastic types, the processes unravelled here suggest that microplastics are relevant long-term anthropogenic stressors and drivers of global change in terrestrial ecosystems.
Microplastics can affect biophysical properties of the soil. However, little is known about the cascade of events in fundamental levels of terrestrial ecosystems, i.e., starting with the changes in soil abiotic properties and propagating across the various components of soil−plant interactions, including soil microbial communities and plant traits. We investigated here the effects of six different microplastics (polyester fibers, polyamide beads, and four fragment types: polyethylene, polyester terephthalate, polypropylene, and polystyrene) on a broad suite of proxies for soil health and performance of spring onion (Allium fistulosum). Significant changes were observed in plant biomass, tissue elemental composition, root traits, and soil microbial activities. These plant and soil responses to microplastic exposure were used to propose a causal model for the mechanism of the effects. Impacts were dependent on particle type, i.e., microplastics with a shape similar to other natural soil particles elicited smaller differences from control. Changes in soil structure and water dynamics may explain the observed results in which polyester fibers and polyamide beads triggered the most pronounced impacts on plant traits and function. The findings reported here imply that the pervasive microplastic contamination in soil may have consequences for plant performance and thus for agroecosystems and terrestrial biodiversity.
Feste Referenzmaterialien für die Spurenanalytik umweltrelevanter organischer Schadstoffe erfordern aufgrund der geringen thermischen Belastbarkeit der Analyten besondere Aufarbeitungsstrategien für die Herstellung repräsentativer Teilproben. Das in der Fachgruppe I.2 seit 1994 für diesen Zweck systematisch aufgebaute technologische Instrumentarium wird vorgestellt, und das im Laufe der Jahre angesammelte Know How wird anhand von Beispielen vermittelt. Das im Laboratorium I.21 entwickelte Qualitätssystem für eine optimale Logistik der Arbeitsabläufe der Probenherstellung und -verwaltung sowie für eine bedarfsgerechte Charakterisierung der Materialien wird ausführlich erläutert.
Bezüglich der Verwendung der Referenzmaterialien wird herausgestellt, daß es zwei gleichberechtigte Anwendungsrichtungen gibt: die interne Qualitätskontrolle mit zertifizierten Referenzmaterialien (ZRM, z.B. für die Methodenvalidierung) und die externe Qualitätskontrolle (Proficiency Testing = Kompetenzbewertung von Prüflaboratorien). Referenzmaterialien für das Proficiency Testing, die im Umweltbereich in viel größeren Stückzahlen umgesetzt werden können als ZRM, weisen bezüglich Homogenität und Charakterisierung die gleichen Qualitätskriterien wie ZRM auf. Diese Materialien haben - auch im internationalen Maßstab - stark an Bedeutung gewonnen.
Ein englisches Abstract gibt es nicht, aber eine Grobgliederung zur Vortragsankündigung:
This lecture includes:
· the technological and logistical aspects of reference material preparation and sub-sampling and subsequent sample management,
· appropriate measurement strategies for homogeneity and stability studies,
· the use of relevant statistical tests to evaluate those measurement data,
· the organisation of interlaboratory studies based on traceable measurements
ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment.
The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1 mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80 pg/mg were provided for 27–35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield.
Thermo-Desorption Gas Chromatography-Mass Spectrometry (TD-GC-MS) was used to investigate the thermal degradation of two different polyurethanes (PU). PU samples were heated at different heating rates and the desorbed products were collected in a cold injection system and thereafter submitted to GC-MS. Prospects and limitations of the detection and quantification of semi-volatile degradation products were investigated. A temperature dependent PU depolymerization was
found at temperatures above 200 °C proved by an increasing release of 1,4-butanediol and methylene diphenyl diisocyanate (MDI) representing the main building blocks of both polymers. Their release was monitored quantitatively based on external calibration with authentic compounds. Size Exclusion Chromatography (SEC) of the residues obtained after thermodesorption confirmed the initial competitive degradation mechanism indicating an equilibrium of crosslinking and depolymerization as previously suggested. Matrix-Assisted Laser Desorption Ionization (MALDI) mass spectrometry of SEC fractions of thermally degraded PUs provided additional hints on degradation mechanism.
The total petrol hydrocarbon (TPH) content in soil is determined by gas chromatographic separation and flame ionisation detection according to ISO 16703 in routine laboratories for about 20 years. The development of the interlaboratory variability observed with this analytical procedure over 15 years in a proficiency testing scheme conducted annually with more than 170 participants is evaluated in detail. A significant improvement of the reproducibility standard deviation among participants is observed over the years and attributed to an increasing familiarity with the procedure. Nevertheless, the determination of TPH in the environmentally relevant mass fraction range between 500 mg/kg and 10 000 mg/kg in soils or sediments is far from reaching the reproducibility standard deviations predicted by the Horwitz curve. It is seen that laboratories with sporadic participation tend to report higher bias, while a core group of laboratories participating on a regular basis arrived at reproducibility standard deviations below 20 %. Results from a given laboratory obtained on two different samples tend to be highly correlated in the same PT round indicating a sound repeatability. Expectedly, the within-laboratory correlation between results from consecutive rounds was considerably lower. However, results from consecutive rounds with a temporal distance of 1, 2 or 3 years revealed largely similar correlations which suggests that the within-laboratory reproducibility adjusts to a constant level at least after a period of 1 year.