Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (36) (entfernen)
Schlagworte
- Brominated flame retardant (4)
- Chiral separation (3)
- Extraction (3)
- Gas chromatography (3)
- HPLC-MS/MS (3)
- Analysis (2)
- Breath (2)
- Diastereomers (2)
- Flame retardant (2)
- GC-MS (2)
- Groundwater (2)
- Hydroxylation (2)
- Mass spectrometry (2)
- Phenols (2)
- Proficiency testing (2)
- Reference materials (2)
- Sampling (2)
- Solid phase microextraction (2)
- Summation parameter (2)
- Volatile organic compounds (2)
- Volatilome (2)
- A549 (1)
- APCI (1)
- Absolute configuration (1)
- Acrylamid (1)
- Active sampling (1)
- Alcohol marker (1)
- Anomalous dispersion (1)
- Anomeric configuration (1)
- Benzenes (1)
- Bioaccumulation (1)
- Bioisomerization (1)
- Biomarkers (1)
- Bleaching (1)
- Bromierte Falmmschutzmittel (1)
- Calibration (1)
- Cancer (1)
- Certification (1)
- Certified reference materials (1)
- Combustion (1)
- Contaminated site (1)
- Contamination (1)
- Crystal structures (1)
- Cysteic acid (1)
- Cytochrom (1)
- Cytochrome P450 (1)
- Cytochromes (1)
- D-Glucuronic acid derivates (1)
- Derivatisierung (1)
- Derivatization (1)
- Detection dog (1)
- Enantiomer fraction (1)
- Enantiomer-specific bioaccumulation (1)
- Enantiomer-specific determination (1)
- Enantiomeric fraction (1)
- Enantiomers (1)
- Equivalence (1)
- Equivalent carbon number (1)
- Ethyl glucuronide (1)
- European Reference Material (1)
- External quality management (1)
- Fish feeding experiment (1)
- Flame ionization detection (1)
- Fortification (1)
- Fuel (1)
- Furfurals (1)
- GC-AED (1)
- Gasoline (1)
- Groundwater monitoring (1)
- HBCD (1)
- HPLC (1)
- HPLC-DAD (1)
- HPLC-ESI-MS/MS (1)
- HPLCMS/MS (1)
- Hair (1)
- Hair testing (1)
- Hexabromcyclododecan (1)
- High resolution NMR (1)
- High-throughput analysis (1)
- Homogeneity (1)
- Honey bees (1)
- Hydrochar (1)
- Interlaboratory study (1)
- Ion chromatography (1)
- Isoleucin (1)
- Kinetics (1)
- LC-MS (1)
- Liquid chromatography (1)
- Long term stability (1)
- Lung cancer (1)
- Marker (1)
- Measurement uncertainty (1)
- Metabolism of HBCD (1)
- Metaboliten (1)
- Methane (1)
- Method development (1)
- Method validation (1)
- Micropulverization (1)
- Micropulverized extraction (1)
- Odour discrimination task (1)
- Optical rotation (1)
- Organic pollutants (1)
- Organohalogen compounds (1)
- Oxidation (1)
- PCB (1)
- Passive sampling (1)
- Phase I metabolism (1)
- Predicting sites of metabolism (1)
- Process water (1)
- QM (1)
- Rearrangement (1)
- Remediation (1)
- Sediment (1)
- Sewage sludge (1)
- Simulation (1)
- Sniffer dogs (1)
- Stabilisation (1)
- Standardisation (1)
- Static headspace (1)
- Synthesis (1)
- Synthetic air (1)
- TBBPA-dbpe (1)
- Total organic carbon (1)
- Total petroleum hydrocarbons (1)
- Trichloroethene (1)
- VOC (1)
- Vinyl chloride (1)
- Waste (1)
- X-ray analysis (1)
- dog training (1)
- herbs (1)
- reference materials, (1)
- scent dog (1)
- smell (1)
- training model (1)
Organisationseinheit der BAM
1,2,5,6,9,10-Hexabromocyclododecane (HBCD) is a widely used flame retardant, which tends to persist in the environment and accumulates in biota. The six stereoisomers (three racemates named α-, β-, and γ-HBCD) of the technical mixture were isolated with high-performance liquid chromatography (HPLC). Direct separations were performed on a chiral stationary phase containing permethylated -cyclodextrin (NUCLEODEX -PM column) and the pure enantiomers of α-, β-, and γ-HBCD were physically characterized for the first time. The absolute configurations of all six isomers were determined by anomalous dispersion using single crystal X-ray crystallography. Optical rotations αD in tetrahydrofuran were +4.2/-4.0 (α-HBCD), +26.1/-27.5 (β-HBCD), and +68.0/-66.3 (γ-HBCD). The sense of rotation could be correlated with the absolute configurations of α-, β-, and γ-HBCD enantiomers and their order of elution on a chiral permethylated β-cyclodextrin-bonded stationary phase. The diastereomers α-, β-, and γ-HBCD displayed distinctly different melting points as well as 1H-, 13C NMR, and IR spectra.
The title compound [systematic name: (2R,3R,4S,5R,6R) 2-(acetoxymethyl)-6-propoxytetrahydro-2H-pyran-3,4,5-triyl triacetate], C17H26O10, was formed by a Koenigs-Knorr reaction of 2,3,4,6-tetra-O-acetyl-α-D-glucopyranosyl bromide and n-propanol. The central ring adopts a chair conformation. The crystal does not contain any significant interactions such as hydrogen bonds.
The performance of twelve laboratories with previously established proficiency in the determination of the mineral oil content in a fresh water sediment is described. The summation parameter total petrol hydrocarbon (TPH) is defined according to ISO 16703:2004 with regard to the sample preparation to be applied, the flame ionisation detection (FID) and the boiling range of C10C40 to be integrated. Comprehensive tests of homogeneity and stability have been carried out on the candidate material using appropriate models. The outcome of the study served as the basis for the certification of the candidate reference material as ERM-CC015a. The certified mass fraction is 1,820±130mgkg-1 and traceability was established by using an appropriate calibration standard certified for the mass fraction of C10C40. The interlaboratory scatter of measurement results in this exercise can largely be explained by the variability of the individual calibrations based on this common calibration standard.
Der Einsatz aktiver (Pumpprobennahme,
Schöpfprobennahme) und passiver (Diffusionsprobennahme)
Probennahmetechniken zur Gehaltsbestimmung von
LHKW sowie Ethen und Methan in Grundwasser wird aus
ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit
von Analysendaten untersucht. Am Beispiel einer Kontamination
mit Trichlorethen sowie 1,2-Dichlorethen und
Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit
der passiven Probennahme durch unzureichende
Strömungsverhältnisse im Aquifer sowie biologische
Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme
ist bei ungeklärten oder unzureichenden Strömungsverhältnissen
im Grundwasserleiter daher der Vorzug
zu geben. Das gaschromatographische Verfahren für Vinylchlorid
mittels Dampfraumtechnik wird um die Quantifizierung
von Methan und Ethen erweitert. Dabei werden für
die Bewertung von Altlasten relevante Bestimmungsgrenzen
von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan)
erreicht.
Aus der Validierung der Analysenmethode und den
Ergebnissen verschiedener Probennahmen werden Toleranzbereiche
für die Ergebnisse eines Grundwassermonitorings
abgeschätzt. Diese Streubreiten von Monitoring-
Ergebnissen sollten von Ingenieurbüros und zuständigen
Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse
eines LHKW-Grundwasserschadens beachtet
werden.
Odor Perception by Dogs: Evaluating Two Training Approaches for Odor Learning of Sniffer Dogs
(2017)
In this study, a standardized experimental set-up with various combinations of herbs as odor sources was designed. Two training approaches for sniffer dogs were compared; first, Training with a pure reference odor, and second, training with a variety of odor mixtures with the target odor as a common denominator. The ability of the dogs to identify the target odor in a new context was tested. Six different herbs (basil, St. John’s wort, dandelion, marjoram, parsley, ribwort) were chosen to produce reference materials in various mixtures with (positive) and without (negative)chamomile as the target odor source. The dogs were trained to show 1 of 2 different behaviors, 1 for the positive, and 1 for the negative sample as a yes/no task. Tests were double blind with one sample presented at a time. In both training approaches, dogs were able to detect chamomile as the target odor in any presented mixture with an average sensitivity of 72% and a specificity of 84%. Dogs trained with odor mixture containing the target odor had more correct indications in the transfer task.
The concentration of contaminants in groundwater samples can be decreased by degradation in the time course between field sampling and quantification in the laboratory, especially in samples from sites where degradation activity is enhanced by remediation measures. The sampling sites covered a variety of priority organic pollutants such as volatile aromatic and chlorinated compounds, phenols and petroleum hydrocarbons and different remediation strategies such as anaerobic and aerobic microbial in situ degradation, in situ chemical oxidation, and on-site purification with biological treatment. The stability of the contaminants' concentration was investigated over a time range of several hours without cooling in the autosampler of the analytical equipment (short term) and over several days of storage until analysis (long term). A number of stabilisation techniques suggested in international standards ISO 5667-3:2013 and ASTM D6517:2000 were compared both with regard to short term and long term stabilisation of the contaminants and their practicability for field sampling campaigns. Long term storage turned out to be problematic for most compound groups even under cooling. Short term stability was problematic also for volatiles such as benzenic aromates, naphthalene and volatile organic halogenated compounds to be analysed by headspace gas chromatography. Acidification (pH <2) was sufficient to prevent degradation of benzenic aromates, naphthalene, phenols and petrol hydrocarbons for up to seven days. The use of acids was not applicable to stabilise volatiles in waters rich in carbonates and sulphides due to stripping of the volatiles with the liberated gases. The addition of sodium azide was successfully used for stabilisation of volatile organic halogenated compounds.
The nature and concentrations of volatile organic compounds (VOCs) in chars generated by hydrothermal carbonization (HTC) is of concern considering their application as soil amendment. Therefore, the presence of VOCs in solid HTC products obtained from wheat straw, biogas digestate and four woody materials was investigated using headspace gas chromatography. A variety of potentially harmful benzenic, phenolic and furanic volatiles along with various aldehydes and ketones were identified in feedstock- and temperature-specific patterns. The total amount of VOCs observed after equilibration between headspace and char samples produced at 270 °C ranged between 2000 and 16,000 µg/g (0.2–1.6 wt.%). Depending on feedstock 50–9000 µg/g of benzenes and 300–1800 µg/g of phenols were observed. Substances potentially harmful to soil ecology such as benzofurans (200–800 µg/g) and p-cymene (up to 6000 µg/g in pine wood char) exhibited concentrations that suggest restrained application of fresh hydrochar as soil amendment or for water purification.
A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM.
A practical method for the quantification of
total purgeable organic sulfur (POS) in highly contaminated
groundwater is described. Volatile organic sulfur
compounds (VOSC) are purged from the water samples by
a stream of oxygen and combusted. The emerging sulfur
dioxide is absorbed in H2O2 and converted to sulfate which
is quantified by ion chromatography and reported as mass
sulfur equivalent. The overall limit of quantification is
0.03 mg l1. The content of POS is balanced with the total
VOSC determined by GC-AED after liquidliquid extraction.
Separate determination of the non-volatile organic
sulfur compounds by direct combustion of the water sample
and adsorption to charcoal yielded a mass balance of
the total sulfur content. Semi-quantitative GC-MS after
purge & trap accumulation revealed that the VOSC mixture
is composed of C1C4 alkyl sulfides. The implementation
of the developed methodology for the quantification of
VOSC as potential catalyst poison in a cleaning plant
for groundwater contaminated with volatile haloorganics
(VOX) is presented.