Filtern
Dokumenttyp
- Zeitschriftenartikel (8)
- Vortrag (3)
- Beitrag zu einem Tagungsband (1)
- Sonstiges (1)
Sprache
- Englisch (13)
Schlagworte
- Ellipsometry (13) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
CdSe films grown on Ti-coated polished steel by constant-current deposition from an aqueous solution containing selenosulfite and cadmium nitrilotriacetate have been studied by spectroscopic ellipsometry under in-situ conditions. Ellipsometric parameters, tan? and cos?, were measured both as a function of deposition time at ? = 825 nm and of wavelength (? = 500-900 nm) for constant film thickness from 0.02 µm to 2.3 µm. The model used for data analysis, Ti-substrate | TiO2 | CdSe-film | solution, with optically homogenous phases was valid for film thickness larger than 0.3 µm. Refractive indices and extinction coefficients of the 2.3-µm film were derived for ? = 500900 nm. A direct band-gap of 1.72 eV was determined. The faradaic efficiency of electrodeposition was 0.93 for a current density of 50 µA cm-2.
In this work, thin iron doped tin oxide layers (3–6 nm) were investigated with regard to gas sensitivity by means of surface plasmon resonance (SPR) effect with ellipsometric readout. The experimental set-up was a Kretschmann configuration with gold as metal layer. The sensor system was exposed to different concentrations of methane in the low ppm range and the sensor response of an uncoated gold layer compared to a gold layer coated with iron doped tin oxide. The additional layer effects stability with regard to drift behavior of the sensor and an increase in sensitivity. Furthermore, the sensor is able to detect the toxic gas carbon monoxide in low concentration range (down to 0.5 ppm). The thin layers were investigated by X-ray photoelectron spectroscopy, secondary electron microscopy and spectroscopic ellipsometry. The possible mechanisms taking place on the surface are discussed.
A gas sensor system based on the surface plasmon resonance (SPR) effect in a 44 nm Au layer was studied. The usability of this sensor system was investigated for several analyte gases and gas mixtures which are interesting due to their flammability, toxicity or greenhouse effect. The SPR effect of gold was measured in nitrogen and compared with the gaseous alkane series which caused a shift of the position of the SPR effect. For in situ measurements, the phase shift Δ at the SPR angle (ψ minimum) in the analyte gas mixtures was measured for investigated gases in comparison with nitrogen. With this method, detection limits of different gases could be determined, which lie in a range interesting for safety engineering. Furthermore the aging effect of the gold layers which leads to loss in sensitivity of the sensor was investigated.
Embedding of information on surfaces is state of the art for identification testing in which public, hidden and forensic features are used. In many instances, the legal authentication of a product, a material or a document is required. Among the surface-based encoded labels, bar codes and data matrices are most frequently applied. They are publicly visible. The material itself is irrelevant, only a sufficient optical contrast is required.
However, a strong material dependence of the label can be achieved by means of Fabry-Perot layer stacks. Stack designs are described with regard to all three security levels: public features (e.g. color and tilt effect) perceptible by the human eye, hidden features (e.g. optical response in a given spectral range) detectable by commonly available instruments and forensic features (ellipsometric quantities Ψ and Δ as a function of wavelength λ and angle of incidence AOI) only detectable by sophisticated instruments.
Regarding material-correlated authentication, ellipsometric quantities Ψ and Δ are used as encoded forensic features for the first time. Hence, Fabry-Perot layer stacks as information carriers in combination with imaging ellipsometry as optical read-out system provide all-in-one anti-counterfeiting capabilities.
Standardisation of ellipsometry is mainly based on three documents: pioneering work at NIST [1] on film standards, a publicly available specification and stan-dard testing procedure [2] for real-world samples by BAM and a standard specification for integrated metrology by SEMI [3]. Other activities refer to inter-laboratory comparisons for selected layer/substrate systems and analytical methods including ellipsometry [4] and the development of combined standards for thickness d and step height h [5].
Generally, precision of ellipsmetry in terms of raw data Ψ and Δ meets the major demands for all ellipsometric principles (RPE, RAE, PME, RCE, NE).
As a result, fingerprint capabilty is al-most perfect for various layer/substrate systems. However, this is not true for accuracy in terms of physical quantities such as thickness d, optical (n, k) and dielectric constans (ε1, ε2,) as modelling is required. Hence, the layer/substrate and material dependent validation of models is nowadays a key issue.
In contrast to the sub-nanometer sensi-tivity in vertical direction, the effective lateral resolution of almost all ellipso-metric principles except for imaging null
ellipsometry is rather poor, usually be-yond 100 µm.
Hence, nanometer-scaled homogeneity testing and the measurement of micro- and nanopatterned structures is not feasible by standard configurations.
An ellipsometric gas sensor based on the surface Plasmon resonance (SPR) effect of ~ 43 nm thick gold layers was investigated. To protect the gold layer from contamination and to improve the detection limits, the gold layers were top-coated with 5–6 nm thick layers of organic a-C:H or with inorganic metal oxides TiO2 or ZrO2. The additional layers increased the long-term stability, whereas the metal oxide layers protect better than a-C:H. Furthermore, the additional layers decreased the detection limits by one order of magnitude in case of a-C:H and two orders of magnitude in case of the oxides. It could be shown that the detection limits also depend on the kind of preparation (sol–gel process or physical vapour deposition) of the additional layers.
Interlaboratory comparison: optical property classification of carbon-based films by ellipsometry
(2017)
The paper addresses the “INTERLABORATORY COMPARISON: OPTICAL PROPERTY CLASSIFICATION OF CARBON-BASED FILMS BY ELLIPSOMETRY” and the following points are discussed in more detail: Established classification for mechanical properties, Complementary classification for optical properties, Ellipsometry for determination of optical constants n-k plane as material fingerprint, Samples, participants & set-ups (samples: Japan, participants: Japan, Germany, France, set-ups: Japan, Germany, USA) and Results of interlaboratory comparison: thickness, n & k.
The talk addresses the STANDARDIZATION OF ELLIPSOMETRY and the following points are discussed in more detail: historical background of ellipsometry, history of International Conferences on Ellipsometry, Workshops Ellipsometry in Germany and Europe, information on German/European Working Group Ellipsometry, technical/industrial importance of ellipsometry, applications on non-ideal material systems and standardization activities on ellipsometry.