Visualization of surface modifications may be very challenging for coating/substrate systems of either almost identical optical constants, e.g. transparent films on substrates of the same material, or minor film thickness, substance quantity and affected area, e.g. ultra-thin or island films. Methods for visualization are optical microscopy (OM), imaging ellipsometry (IE), and referenced spectroscopic ellipsometry (RSE). Imaging ellipsometry operates at oblique incidence near Brewster angle of the bare, clean or unmodified substrate. In this configuration, reflected intensities are rather weak. However, the contrast to add-on and sub-off features may be superior. Referenced spectroscopic ellipsometry operates in a two-sample configuration but with much higher intensities. In many cases, both ellipsometric techniques reveal and visualize thin films, printed-pattern, laser-induced changes, and impurities better than optical microscopy. In particular for stratified homogeneous modifications, ellipsometric techniques give access to modelling and hence thickness determination. Modifications under investigation are polymer foil residue on silicon, laser-induced changes of ta-C:H coatings on 100Cr6 steel, imperfections of ta-C:H on thermal silicon oxide, degradation of glass, thin film tin oxide pattern on silicon, printed and dried pattern of liquids such as deionized water, cleaning agents, and dissolved silicone. © 2016 Elsevier B.V. All rights reserved.
The future commercial prospects for adhesive tapes are very good and its application range is very broad. From every-day-use in office, packaging, maintenance, and quick repair in workshops, it ranges from handicraft work, medical purposes and cosmetics up to workmanship. The study describes a new multi-sample approach in adhesive tape testing from theoretical background, preparation of test specimen for tensile as well as shear testing, detailed measurement procedures up to analysis and result interpretation. Various types of single and double-sided pressure sensitive adhesive tapes supplied by different manufacturers were investigated and compared
Iron-doped SnO2 coatings were deposited in a 50 kHz DC-pulsed magnetron sputtering discharge. The pulses had a duration of 4 µs in selected gas mixtures from pure argon up to
60% of oxygen at a constant total pressure of 0.2 Pa. A single target of SnO2 with Fe inset was used. The mass spectrometry study detected the gas-related ions Ar+, O2+ and O+, where the last one becomes the dominant positive ion at higher oxygen contents. Atomic oxygen ions had a higher energy as it resulted from the collision-caused dissociation on the target surface. The tin-related species were detected as Sn+ and SnO+. SnO2+ species were not detected. The deposition rate decreased by using gas mixtures with oxygen as well as the corresponding amount of Sn-related species in the plasma. The increase of oxygen also increased significantly the sheet resistance of the films. The XPS study showed that the iron concentration decreased by using additional oxygen. But the O/Sn ratio in the coatings was constant, contrary to the increased FeO/Fe ratio in the films. An additional analysis of the coatings by spectroscopic ellipsometry has shown a dependence of the polarizability and the permittivity on the amount of oxygen used during the deposition. In contrast, the study has found no such dependence for the absorption of the layers.
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO2, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO2 particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO2, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection.
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO₂, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO₂ particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO₂, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection
Novel air-coupled ultrasonic transducer combining the thermoacoustic with the piezoelectric effect
(2016)
In recent years, there has been an increasing industrial demand for one-sided inspection of various structures by means of air-coupled ultrasonic technique. Lightweight structures based on carbon-fibre-reinforced polymers may have very complex shapes, making air-coupled transmission difficult or even impossible. The inspection of concrete structures is another example where one-sided inspection is required.
To address these challenges a new type of transducer for air-coupled pulse-echo inspection was developed, which unites two principles: thermoacoustic emission and piezoelectric reception. The thermoacoustic emitter is a titanium electrode with a thickness of several tens of nanometer. This electrode was deposited onto charged cellular polypropylene, which serves as a piezoelectric receiver. The thermoacoustic transmission is based on a transformation of the thermal energy of an electrically heated electrode into the acoustic energy of an ultrasonic wave. Thermoacoustic emitters provide resonance-free behaviour and thus extremely broadband pulses. Charged cellular polypropylene is piezoelectric due to the polarization of its cells and it is well matched to air, with a Young modulus in the order of magnitude of MPa. In this contribution we present some pulse-echo measurements with the first prototypes of the combined thermoacoustic-piezoelectric transducer.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
The multiple-sample approach by means of centrifugal adhesion testing (CAT-technology) allows the determination of bonding strength of adhesive-bonded joints on a statistical basis of up to eight samples. Therefore, it is obvious to ensure the continuous handling and identical processing of an octet of samples within the entire process chain of wet-chemical cleaning, plasma-chemical pre-treatment, bonding of samples, and testing of bonding strength. Within the multiple-sample bonding set-up (MPKV-technology) a defined bonding pressure can be adjusted regardless the actual number of samples. A comparison of single- and multiple-sample approach is made for bonding strength of selected adhesives, double-sided adhesive tapes and different material combinations [stainless steel (V2A) vs. stainless steel, polyamide (PA), or polypropylene (PP)]. It is shown that both technologies improve reliability of results
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A high-performance fiber Bragg grating-based (FBG) sensor device has been developed for the detection of small magnetic fields. Based on a smart multilayer jacket around the fibre over the physical length of the FBG, magnetic fields generated by rotating machine parts, power generators or power cable can be easily detected, analysed and evaluated. Consequently, this innovative, on-line and non-contact inspection method results in an increase in quality and reliability of high-performing machine parts, devices and cables. The basic physical principle is based on a magnetostrictive multilayer system that strains the high-resolution FBG element in presence of magnetic fields. Subsequently, a fixed relationship between induced magnetic field and wavelength change of the FBG element describes the characteristic sensitivity curve. Intensive tests regarding characterisation of this magnetic field FBG sensor have been carried out and its performance has been evaluated.