This work presents first results from repeti-tive CO2 injection experiments performed on a recently built-up 400 m² soil test field with gas injection system. The test field contains 48 membrane-based linear gas sensors that were installed in several depths of the test field. Sensors for measuring meteorological parameters (e.g., wind / rain) and the parameters soil temperature, soil moisture, and groundwater level were installed additionally. A more de-tailed description of the test field setup can be found in. A short description of the mem-brane-based linear gas sensors’ functional prin-ciple can be found in.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
This work presents first results from repetitive CO2 injection experiments performed on a recently built-up 400 m² soil test field with gas injection system. The test field contains 48 membrane-based linear gas sensors that were installed in several depths of the test field. Sensors for measuring meteorological parameters (e.g., wind / rain) and the parameters soil temperature, soil moisture, and groundwater level were installed additionally.
A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.