Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (28)
- Posterpräsentation (19)
- Zeitschriftenartikel (14)
- Vortrag (4)
- Sonstiges (2)
- Forschungsbericht (1)
Sprache
- Englisch (55)
- Deutsch (11)
- Mehrsprachig (1)
- Polnisch (1)
Schlagworte
- Nano aerial robot (10)
- Mobile Robot Olfaction (8)
- Swarm (8)
- Electronic nose (6)
- Gas sensing (5)
- Environmental monitoring (4)
- TDLAS (4)
- Tomographic reconstruction of gas plumes (4)
- Aerial robot (3)
- Drop test (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (68) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (4)
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Der Fokus des Arbeitsfelds ist die messtechnisch fundierte Anwendung der 3D-Verfahrenskombination zur Lösung vielfältiger Messaufgaben mit optimaler Datenqualität für interne und externe Kunden.
Das setzt insbesondere eine jeweils problembezogene Messmethodik voraus. Dazu setzen wir kameragestützte 3D-Koordinatenmessverfahren ein, die auf dem fotogrammetrischen Prinzip der Bildtriangulation beruhen. Darunter fallen folgende miteinander flexibel kombinierbare Verfahrensmodifikationen: Mehrbildfotogrammetrie, Messadapter für Geometriemerkmale, Streifenprojektionsverfahren, statische bis hochdynamische Stereofotogrammetrie auf Punktebasis oder aufgabenangepasster Oberflächenmuster und mechanisch-optische Taster.
KonSens (Kommunizierende Sensorsysteme für die Bauteil- und Umweltüberwachung) - Projektergebnisse
(2019)
Im Projekt KonSens werden für die Anwendungsbeispiele bauteilintegrierte Sensorik für Betonkomponenten und mobile Multigassensorik Sensorsysteme in Form von Funktionsmustern entwickelt, validiert und angewendet. Schwerpunkte liegen einerseits in der Detektion und Bewertung von Korrosionsprozessen in Beton und andererseits in der Detektion und Quantifizierung sehr geringer Konzentrationen toxischer Gase in der Luft. Dabei ist die Adaption der sensorischen Methoden aus dem Labor in reale Messumgebungen inklusive geeigneter Kommunikationstechnik ein wichtiger Aspekt.
Im Projekt KonSens werden für die Anwendungsbei-
spiele bauteilintegrierte Sensorik für Betonkomponen-
ten und mobile Multigassensorik Sensorsysteme in
Form von Funktionsmustern entwickelt, validiert und
angewendet. Schwerpunkte liegen einerseits in der
Detektion und Bewertung von Korrosionsprozessen in
Beton und andererseits in der Detektion und Quantifi-
zierung sehr geringer Konzentrationen toxischer Gase
in der Luft. Dabei ist die Adaption der sensorischen
Methoden aus dem Labor in reale Messumgebungen
inklusive geeigneter Kommunikationstechnik ein
wichtiger Aspekt.
Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air Quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The System is part of a mobile sensor network of several sensor units, which can also be used as standalone systems.