A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
Durch faseroptische Sensoren können Bauteile im Einsatz kontinuierlich überwacht und frühzeitig Informationen über Materialveränderungen gewonnen werden. Mittels einer magnetostriktiven Aktorschicht, welche den Sensor umhüllt, kann nun auch die korrekte Sensorfunktion jederzeit kontrolliert werden. Als Aktorschicht eignet sich galvanisch abgeschiedenes reines Nickel oder Nickel-Eisen in der Zusammensetzung 50:50. Um diese haftfest mit dem Sensor zu verbinden wurde ein ECD/PVD-Kombinationsschichtsystem entwickelt. Die mechanischen Eigenschaften der ECD-Schicht können sowohl mit einer auf die Fasergeometrie angepassten instrumentierten Eindringprüfung als auch einem 2-Punkt-Biegeversuch bestimmt werden.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m² test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
Geogenic gases from natural sources, carbon dioxide (CO2) from a geological repository (carbon capture and storage - CCS) or a leaking gas pipeline can present serious risks in industrial and urban areas. To extend the lead time for risk treatment in such critical regions, reliable detection of gases within the shallow subsurface is required to observe critical gas accumulations before degassing into the atmosphere.
A near real-time monitoring approach is introduced to determine the volumetric expansion of a leakinggas in the subsurface. Considering the pressure relaxation with the ambient air pressure, the approach enables the forecasting of the final size of a pressurized gas body in terms of characteristic lengths. According to theoretical basics, such a characteristic length, which enables us to perform a gas (safety) measurement based on a purely geometrical measure, behaves independently of subsurface properties,i.e., it enables a reliable quantification of the escaping gas irrespective of its heterogeneous or changingflow path distribution. A field test for a 10 l/min pinhole leakage injected into a 10 m long, 0.4 m wide, 0.95 m deep soil-filled trench that was equipped with linear sensors shows the lateral-vertical volumetric gas expansion along these sensors, and demonstrates the applicability of the characteristic length approach.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
Concept for investigating mechanical and thermal impacts on distributed subsurface gas monitoring
(2016)
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO 2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas Distribution behavior. In this paper, we briefly describe the setup of a CO 2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.