Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (10)
- Zeitschriftenartikel (7)
- Vortrag (1)
Sprache
- Englisch (18)
Schlagworte
- Gas storage areas (11)
- Membrane-based gas sensing (11)
- Subsurface monitoring (11)
- Distributed linear sensor (5)
- Distributed sensor (4)
- Computed tomography (3)
- Linear sensor (3)
- CO2 (2)
- Carbon capture and storage (2)
- Fiber optical sensing (2)
Eingeladener Vortrag
- nein (1)
In preliminary work, gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. In this study, first experimental results are presented for adapting the technology for measuring methane (CH4). A material with suitable selective permeability was identified and utilized in a sensor setup containing the gas selective membrane and a reference membrane, both integrated in a measuring cell, to which a gas stream with defined CH4 concentrations was applied. The results prove the sensor's capability for measuring methane and indicate further application potential of the method, e.g., as a robust field monitoring technology, since CH4 is the major component of natural gas, town gas, and fracking gas.
One of the main unsolved issues of under-ground storages for, e.g., CO2, H2, and natural gas is the comprehensive surveillance of these areas with reasonable effort and costs. Conventional sensors (e.g., soil air probes or borehole probes), however, can only be used for punctual or locally limited measurements; further their application can cause structural influences (invasive application).
In this paper, we describe in detail the setup of a CO2 injection soil test field. This test field will be used to enhance and validate an innovative ap-proach for distributed subsurface monitoring of gas storage areas. To the author’s knowledge, this is the first time that, for this purpose, a test field is built in an application relevant scale.
A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
A 400 m2 soil test field with gas injection system was built up, which enables an experimental validation of linear membrane-based gas sensors – a sensor technology which was developed based on the selective permeation of gases through membranes. Several soil watering and injection experiments with carbon dioxide at different days with varying boundary conditions were performed showing that the sensor behaves mostly insensitive to the environmental conditions investigated, i.e., barometric pressure fluctuations, soil temperature, air temperature and humidity, sun duration, and wind speed. Furthermore, depending on water infiltration, a gas phase displacement could be observed in-situ based on the changed measurement signal. The results of the validation experiments highlight the potential of the method for rapid leak detection and localization qualifying the sensor particularly for safety applications, e.g., in underground gas storage areas.
One of the main unsolved issues of CCS is the comprehensive surveillance of CO2 storage areas with reasonable effort and costs. This study presents an approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane based measurement technology for in situ monitoring of gases in soil and fibre optical sensing of temperature and strain (as a measure for structural change). A test field of application-relevant dimensions is built up to validate and optimize the technology.
Geogenic gases such as CH4 or CO2 from natural sources, gases (CCS-CO2, H2, Natural
gas, City gas …) from a geological repository, or a leaking gas pipeline can present serious
risks in industrial and urban areas where the density of infrastructural elements increases as
well as above and below ground. To extend the lead time for risk treatment in such critical
regions, reliable detection of gases within the shallow subsurface is required to observe
critical gas accumulations before degassing into the atmosphere.
A near real-time monitoring approach is introduced to determine the volumetric expansion of
such a gas escaping from a leak in the subsurface. Considering the pressure relaxation with
the ambient air pressure, the approach enables the forecasting of the final size of a
pressurized gas body in terms of characteristic lengths. According to theoretical basics, such
a characteristic length, which allows to perform a gas (safety) measurement based on a
purely geometrical measure, behaves independently of subsurface properties, i.e., it enables
a reliable quantification of the escaping gas, irrespective of its heterogeneous flow path
distribution. A field test for a 10 l/min pinhole leakage of CO2 injected in an unsaturated Chernozemic soil (agricultural test field Bad Lauchstädt)that was equipped with linear gas sensors demonstrates the lateral-vertical volumetric gas expansion along the environment of these gas sensors, and confirms the applicability of the new characteristic length approach.
Linear sensor for areal subsurface gas monitoring - calibration routine and validation experiments
(2014)
Membrane based linear gas sensors and fiber optical sensors feature similar geometries and complement each other in quantities to be measured. To the author's best knowledge, it is the first time that these sensors are combined to a multifunctional sensor for distributed measuring of gas concentrations, temperature, and strain. Objective is a comprehensive monitoring of underground gas storage areas. In the presented project a 400 m² test site and a corresponding laboratory system were just built up to characterize, validate, and optimize the combined sensor. Application of the sensor lines in a grid structure should enable spatial resolution of the measurement data and early detection of relevant events, as gas leakage, temperature change, or mechanical impact. A Calibration routine was developed which can be applied subsequent to underground installation. First measurement results indicate the potential of the method, with regard to highly topical energy transport and storage issues.
Comprehensive monitoring of pipelines over their full length is technically difficult and expensive. Considering a cost-benefit ratio it is reasonable to implement monitoring solutions in pipeline segments, which bear a high risk potential, like residential areas, construction sites, slopes, street or river crossings. Still such segments can measure up to several hundred meters in length, demanding for monitoring solutions that extend along such distances and enable fast response. Point wise sensing and periodical surveillance have clear drawbacks, particularly regarding early damage detection. Fibre optic sensors enable distributed sensing of temperature and strain, but they offer very limited possibilities for measuring gas concentrations. Linear membrane-based gas sensors enable the monitoring of gas concentrations alongside a pipeline. Such line-sensors are implemented in form of flexible tubes and can be arranged inside or outside the pipeline (also underwater or within the subsurface), corresponding to the technical requirements. The measuring method combines the gas specific diffusion rates through a membrane with Dalton’s law of partial pressures and enables the calculation of gas concentrations or the detection of a change of the gas composition. The objective is to detect gas leakages fast and with high reliability. Furthermore, the calibrated system enables to estimate the spatial extent of a leakage. So far the gas concentration measurement is tested for oxygen, carbon dioxide, methane; further gases should follow, e.g. hydrogen, carbon monoxide or mixtures like natural gas. The paper introduces in the different operating modes of line-sensors. A near real-time approach will be demonstrated to quantify the impact of a gas leak on the near environment. This approach is based on a critical length describing the expansion of the leaking gas.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m² test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
Geogenic gases from natural sources, carbon dioxide (CO2) from a geological repository (carbon capture and storage - CCS) or a leaking gas pipeline can present serious risks in industrial and urban areas. To extend the lead time for risk treatment in such critical regions, reliable detection of gases within the shallow subsurface is required to observe critical gas accumulations before degassing into the atmosphere.
A near real-time monitoring approach is introduced to determine the volumetric expansion of a leakinggas in the subsurface. Considering the pressure relaxation with the ambient air pressure, the approach enables the forecasting of the final size of a pressurized gas body in terms of characteristic lengths. According to theoretical basics, such a characteristic length, which enables us to perform a gas (safety) measurement based on a purely geometrical measure, behaves independently of subsurface properties,i.e., it enables a reliable quantification of the escaping gas irrespective of its heterogeneous or changingflow path distribution. A field test for a 10 l/min pinhole leakage injected into a 10 m long, 0.4 m wide, 0.95 m deep soil-filled trench that was equipped with linear sensors shows the lateral-vertical volumetric gas expansion along these sensors, and demonstrates the applicability of the characteristic length approach.
A monitoring method is introduced that creates, in near real-time, two-dimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. A first experimental test indicates the high potential of the proposed method for, e.g., rapid gas leak localization.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
BAM Federal Institute for Materials Research and Testing, in cooperation with the company MeGaSen UG carries out a research project to enhance and validate an innovative approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane-based gas measurement technology for in-situ monitoring of gases in soil and fiber optical sensing of temperature and strain (as a measure for structural change). Key aspect of the research project is the first-time validation of the system in an application relevant dimension. For this purpose a 20 x 20 m2 test field is build. A comprehensive validation of the system is carried out by systematic variation of different parameters like position-dependent gasinjection, temperature and mechanical impact.
A 400 m² soil test field with gas injection system was built up, which enables an experimental validation of linear gas sensors for specific applications and gases in an application-relevant scale. Several injection and soil watering experiments with carbon dioxide (CO2) at different days with varying boundary conditions were performed indicating the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
Concept for investigating mechanical and thermal impacts on distributed subsurface gas monitoring
(2016)
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO 2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas Distribution behavior. In this paper, we briefly describe the setup of a CO 2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas distribution behavior. In this paper, we briefly describe the setup of a CO2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m(2) test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
This work presents first results from repetitive CO2 injection experiments performed on a recently built-up 400 m² soil test field with gas injection system. The test field contains 48 membrane-based linear gas sensors that were installed in several depths of the test field. Sensors for measuring meteorological parameters (e.g., wind / rain) and the parameters soil temperature, soil moisture, and groundwater level were installed additionally.