Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (63) (entfernen)
Schlagworte
- Gas storage areas (9)
- Membrane-based gas sensing (9)
- Subsurface monitoring (9)
- Autonomous micro UAV (5)
- Gas source localization (5)
- Distributed linear sensor (4)
- Distributed sensor (4)
- Electronic nose (4)
- Embedded sensors (4)
- Nanocomposites (4)
- Structural health monitoring (4)
- Chemical and wind sensing (3)
- Computed tomography (3)
- Cone Calorimeter (3)
- Drop test (3)
- Fire retardancy (3)
- Linear sensor (3)
- Nano aerial robot (3)
- Particle filter (3)
- Artificial potential field (2)
- Behälter (2)
- Chemometric techniques (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Fallprüfung (2)
- Fiber Bragg grating (2)
- Fibre optical sensing (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- LOI (2)
- Localization (2)
- Magnetic field (2)
- Magnetostriction (2)
- Mobile robot olfaction (2)
- Monitoring (2)
- Monitoring of CO2 (2)
- Multichannel measuring system (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Quadrocopter (2)
- RFID sensors (2)
- Sensor planning (2)
- Soil test field (2)
- Strain (2)
- Swarm (2)
- TDLAS (2)
- Trail detection (2)
- Trail following (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Wireless sensors (2)
- Actuators (1)
- Aerial robot (1)
- Aerial robot olfaction (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Biologically inspired robots (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- DDS (1)
- Dangerous goods (1)
- Data bus (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Discrimination of multiple gas sources (1)
- Early damage detection (1)
- Early-damage-detection (1)
- Elastoplastic material parameters (1)
- Embedded system (1)
- Embedded systems (1)
- Emission control (1)
- Emissionskontrolle (1)
- Energy harvesting (1)
- Environmental analysis (1)
- Epoxide (1)
- Fiber Bragg gratings (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fiber optical sensing (1)
- Fibre optical sensing (1)
- Field conditions (1)
- Finite element methods (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluorescent sensor (1)
- Fluoreszenz (1)
- Gas dispersion simulation (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasmessung (1)
- Guided wave (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (1)
- Inertial measurement unit (IMU) (1)
- Inertial navigation system (1)
- Intumescence (1)
- Intumescent coating materials (1)
- Lamb wave (1)
- Lamb-waves (1)
- Large scale soil test field (1)
- Leak detection (1)
- Leakage (1)
- Long-term requirements (1)
- Magnetostrictive metal coating (1)
- Membrane-based linear gas sensor (1)
- Metal oxide semiconductor (1)
- Mg(OH)2 (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mikrodrohne (1)
- Mobile Robot Olfaction (1)
- Mobile sensing system (1)
- Modeling and simulation (1)
- Moisture (1)
- Monitoring of CO 2 (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Non-destructive evaluation (1)
- Oil (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- Passive RFID (1)
- Passive sensors (1)
- Person tracking (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID-based sensors (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Reactive plume tracking (1)
- Real-time (1)
- Red Phosphorus (1)
- Reinforced concrete (1)
- Remote gas sensor model (1)
- SHM (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensor calibration and validation (1)
- Sensor requirements (1)
- Sensoren (1)
- Sensors in concrete (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smart structures (1)
- Smartphone (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Subsurface (1)
- TD-GC-MS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Transmission characteristics (1)
- UAV (1)
- UL94 (1)
- Ultrasound (1)
- Uncertainty (1)
- Validation (1)
- Water quality (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- Wireless mobile sensor device (1)
- Wireless sensor network (WSN) (1)
- agricultural economy (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- poly(propylene) (PP) (1)
- spectroscopy (1)
- Öl (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (17)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.9 Chemische und optische Sensorik (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 1.2 Biophotonik (1)
- 8.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (1)
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.----------------------------------------------------------------------------------------------------------------------------------------------------------------
Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen.
Limited access to the object of relevance is often an essential problem in testing routines, e.g. for non-destructive testing of industry facilities or components of means of transportation. The presented project is about the development of a non-destructive testing method for application over great distances (up to 100 m). The method is based on directed excitation and measuring of Lamb waves (guided waves). It enables an effective differentiation of structural and defective indications as well as a classification of different defect types.
The advantage of guided waves is the ability of propagation over great distances. This offers innovative possibilities for the investigation of large or difficult to access constructions. The testing method can be helpful in a broad variety of applications. It is useable for the characterization of plane or cylindrical, thin-walled surfaces of metal or fiber laminated materials. Particularly the investigation of aircraft wings and other aerospace components as well as the investigation of pipelines are addressed fields of application.
One of the main unsolved issues of CCS is the comprehensive surveillance of CO2 storage areas with reasonable effort and costs. This study presents an approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane based measurement technology for in situ monitoring of gases in soil and fibre optical sensing of temperature and strain (as a measure for structural change). A test field of application-relevant dimensions is built up to validate and optimize the technology.
Linear sensor for areal subsurface gas monitoring - calibration routine and validation experiments
(2014)
Membrane based linear gas sensors and fiber optical sensors feature similar geometries and complement each other in quantities to be measured. To the author's best knowledge, it is the first time that these sensors are combined to a multifunctional sensor for distributed measuring of gas concentrations, temperature, and strain. Objective is a comprehensive monitoring of underground gas storage areas. In the presented project a 400 m² test site and a corresponding laboratory system were just built up to characterize, validate, and optimize the combined sensor. Application of the sensor lines in a grid structure should enable spatial resolution of the measurement data and early detection of relevant events, as gas leakage, temperature change, or mechanical impact. A Calibration routine was developed which can be applied subsequent to underground installation. First measurement results indicate the potential of the method, with regard to highly topical energy transport and storage issues.
Polymeric nanocomposites are discussed as one of the most promising advanced materials whose nanoscale effects can be exploited for industry. Layered silicate polypropylene-graft-maleic anhydride nanocomposites are investigated as a model to clarify the potential of such materials in terms of fire retardancy. The nanostructure is characterized using transmission electron microscopy (TEM) and shear viscosity. The fire behavior is characterized using different external heat fluxes in cone calorimeter, limiting oxygen index and UL 94 classification. A comprehensive fire behavior characterization is presented which enables an assessment of the materials’ potential with respect to different fire scenarios and fire tests. The influence of morphology and the active mechanisms are discussed, such as barrier formation and changed melt viscosity. To our knowledge, it is the first attempt to illuminate the concept’s strengths, such as the reduction of flame spread, and weaknesses, such as the lack of influence on ignitability, in a clear, comprehensive and detailed manner.
A method was developed to assess the heat insulation performance of intumescent coatings. The method consists of temperature measurements using the bench-scaled experimental set-up of a cone calorimeter and finite difference simulation to calculate the effective thermal conductivity dependent on time/temperature. This simulation procedure was also adapted to the small scale test furnace, in which the standard time-temperature curve is applied to a larger sample and thus which provides results relevant for approval. Investigations on temperature and calculated effective thermal conduction were performed on intumescent coatings in both experimental set-ups using various coating thicknesses. The results correspond to each other as well as showing the limits of transferability between both fire tests. It is shown that bench-scaled cone calorimeter tests are a valuable tool for assessing and predicting the performance of intumescent coatings in larger tests relevant for approval. The correlation fails for processes at surface temperatures above 750°C, which are not reached in the cone calorimeter, but are attained in the small scale furnace set-up.
Polymeric intumescent coatings are fire protective materials that increase their thermal resistance when exposed to high temperatures to prevent building structures from damage. The idea of the investigation was to develop a simple test method to determine the time dependent thermal conductivity of intumescent coatings. Therefore steel plates were coated with two different intumescent systems. During cone calorimeter tests the temperature at the back side of the coated plates was measured. These results were used to calculate the time dependent thermal resistance of the protective layer with the simulation program IOPT2D for different external heat fluxes and different layer thickness.
The measurement characteristics of every conventional accelerometer are temperature dependent - often to an extent which is highly relevant for the addressed application. For instance, at BAM Container drop tests are performed to investigate and evaluate the structural integrity of Containers for transport and storage of dangerous goods. Often, the test program includes drop tests at specific temperatures, also as part of approval procedures. The applied sensors are exposed to these test conditions and get influenced by them. Acceleration sensors show a considerable temperature influence on their fünction and characteristics. Particularly the damping mechanism of the seismic mass is a critical part. In regard to such applications, capable equipment and methods are required to consider and investigate this aspect in an adequate way. A fortiori as Manufacturer’s infonnation often is deficient. This study presents the setup and results of a method for testing and calibration of acceleration sensors under high dynamic irnpact. It combines a Hopkinson Bar with a temperature chamber.
Zur Untersuchung der Sicherheit von Behältern für den Transport und die Lagerung von Gefahrstoffen und -gütern werden Fallprüfungen durchgeführt. Die Aufpralldynamik und die strukturmechanischen Einwirkungen auf den Behälter werden mittels Beschleunigungsaufnehmern und Dehnungsmessstreifen erfasst. Dabei kommen derzeit Vielkanalmesssysteme zum Einsatz, die eine Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums erfordern, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. Die Verwendung eines Messsystems mit Datenbus und dezentraler Datenspeicherung bietet diesbezüglich einen vielversprechenden Lösungsansatz.
The influence of different organobentonites on the decomposition and the combustion behaviour of an epoxy resin were examined. The epoxy resin is a cationically polymerised cycloaliphatic epoxy resin flexibilised with poly(tetrahydrofuran) (PTHF), with hydroxyl endgroups. The bentonite was modified with either an ammonium or a phosphonium salt. The thermal decomposition of the PTHF induced by the initiator, used for the cationic polymerisation, did neither take place for the nanocomposite based on the ammonium bentonite nor for that based on the phosphonium bentonite. This improved decomposition characteristic lead to a larger time to ignition for both kinds of nanocomposites compared to the not modified polymer, which is not the case for other polymer/clay nanocomposites described in the literature. The fire behaviour was investigated using limiting oxygen index (LOI), a horizontal burner test and a cone calorimeter. The forced flaming conditions in the cone calorimeter were varied using different external heat fluxes between 30 and 70 kW · m-2. The fire behaviour of the nanocomposites was improved in comparison to the polymer, and phosphonium bentonite was superior to ammonium bentonite. The main mechanism is a barrier formation resulting in a reduction of the fire growth rate, which was more pronounced in the case of high external heat fluxes.
Remote gas sensors mounted on mobile robots enable the mapping of gas distributions in large or hardly accessible areas. A challenging task, however, is the generation of threedimensional distribution maps from these gas measurements.
Suitable reconstruction algorithms can be adapted, for instance, from the field of computed tomography (CT), but both their performance and strategies for selecting optimal measuring poses must be evaluated. For this purpose simulations are used, since, in contrast to field tests, they allow repeatable conditions. Although several simulation tools exist, they lack realistic models of remote gas sensors. Recently, we introduced a model for a Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor taking into account the conical shape of its laser beam. However, the novel model has not yet been validated with experiments. In this paper, we compare our model with a real sensor device and show that the assumptions made hold.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.)
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.