Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (56)
- Posterpräsentation (46)
- Vortrag (33)
- Zeitschriftenartikel (12)
- Beitrag zu einem Sammelband (7)
- Forschungsbericht (4)
- Sonstiges (2)
- Dissertation (1)
Sprache
- Englisch (91)
- Deutsch (67)
- Mehrsprachig (2)
- Polnisch (1)
Referierte Publikation
- nein (161) (entfernen)
Schlagworte
- RFID sensors (12)
- Structural health monitoring (12)
- Mobile Robot Olfaction (9)
- Monitoring (9)
- Smart structures (9)
- Sensors in concrete (8)
- Gas sensors (7)
- Nano aerial robot (7)
- Drop test (6)
- Passive RFID (6)
- Swarm (6)
- Tomographic reconstruction of gas plumes (6)
- Funksensorik (5)
- Gas sensing (5)
- Localization of gas sources (5)
- Mikrodrohne (5)
- Sensornetzwerk (5)
- Strukturüberwachung (5)
- UAV-REGAS (5)
- Air quality monitoring (4)
- Environmental monitoring (4)
- Hazardous scenarios (4)
- RFID (4)
- Schadensfrüherkennung (4)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS) (4)
- UAV (4)
- VOC (4)
- Chemical sensing (3)
- Embedded sensor (3)
- Energy harvesting (3)
- Fluorescence (3)
- Gas source localization (3)
- Gas storage areas (3)
- Hopkinson bar (3)
- LoRaWAN (3)
- Long term monitoring (3)
- Membrane-based gas sensing (3)
- Mobile robot olfaction (3)
- Mobile sensing system (3)
- Multisensor system (3)
- Plume tracking (3)
- Quadrocopter (3)
- Sensor requirements (3)
- Sensors (3)
- Subsurface monitoring (3)
- Transmission characteristics (3)
- Wireless sensors (3)
- Accelerometer (2)
- Aerial robot (2)
- Air quality (2)
- Ammonia (2)
- Ammonia gas sensor (2)
- BAM Datenbank Gefahrgut (2)
- Bauwerksüberwachung (2)
- Concrete (2)
- Condition monitoring (2)
- Dangerous goods (2)
- Data fusion (2)
- Data-fusion (2)
- Diagnosis of concrete components (2)
- Digitalisation (2)
- Distributed linear sensor (2)
- Electronic nose (2)
- Environment (2)
- Fiber bragg grating (2)
- Gas detection (2)
- Gas distribution mapping and gas source localization (2)
- Gas standard generator (2)
- Gasmessung (2)
- Gefahrgut (2)
- High impact shock application (2)
- IMS (2)
- Indoor Localization (2)
- Indoor air quality (2)
- Ionenmobilitätsspektrometrie (2)
- Localization (2)
- Long-term requirements (2)
- Magnetic field (2)
- Magnetostrictive metal coating (2)
- Magnetostriktive Beschichtung (2)
- Miniaturized sensor device (2)
- Mobile Robot (2)
- Monitoring of dangerous goods (2)
- Multi sensor device (2)
- Multi-sensor system (2)
- NDT Inspection (2)
- Piezoresistive accelerometer (2)
- Pump control (2)
- Quadrokopter (2)
- RFID-Sensorsysteme (2)
- Robotik (2)
- SHM (2)
- Safety management (2)
- Self-diagnostic fiber optical sensor (2)
- Sensortechnik (2)
- Setup and Validation (2)
- Smart sensors (2)
- Spectroscopy (2)
- Sprengstoffspurendetektion (2)
- Standard gas generator (2)
- Suche und Lokalisierung von gasförmigen Gefahrstoffquellen (2)
- TDLAS (2)
- Temperature characteristics (2)
- Umweltmonitoring (2)
- Wasserstoff (2)
- 3D-Verformungsmessung (1)
- Aerial robot olfaction (1)
- Air-based (1)
- Analysis (1)
- Anemometer (1)
- Anemometric sensor (1)
- Anemotaxis (1)
- Artificial potential field (1)
- Autonomous UAV (1)
- Autonomous micro UAV (1)
- Autonomous robot (1)
- Bauteilintegrierte Sensoren (1)
- Bauteilmonitoring (1)
- Bauwerk (1)
- Behälter (1)
- Berlin Main Station (1)
- Beschleunigungsaufnehmer (1)
- Betonkorrosion (1)
- Bio-inspired (1)
- Biologically inspired robots (1)
- Bridge components (1)
- CCS (1)
- CO2 (1)
- Calibration of electrical quantities (1)
- Calibration of force (1)
- Calibration of temperature (1)
- Carbon capture and storage (1)
- Chemical source localization (1)
- Chemotaxis (1)
- Cone Calorimeter (1)
- Data mapping (1)
- Dehnungsmessstreifen (1)
- Differential displacements (1)
- Digital Certificates (1)
- Digitalisierung (1)
- Distributed multifunctional sensor (1)
- Drop (1)
- Drop tests (1)
- Druckgasspeicher (1)
- DuraBASt (1)
- ECD-Aktorschicht (1)
- ETD (1)
- Early-damage-detection (1)
- Eindringmodul (1)
- Electronic transport documents (1)
- Embedded (1)
- Embedded sensors (1)
- Embedded systems (1)
- Emission control (1)
- Emmbedded sensor (1)
- Energiespeicherung (1)
- Estimation (1)
- Explosionsschutz (1)
- Fallprüfung (1)
- Faser-Bragg Gitter (1)
- Faser-Bragg-Gitter (FBG) (1)
- Faseroptik-Sensoren (1)
- Fiber optical sensing (1)
- Field conditions (1)
- Fire retardancy (1)
- Flammschutz (1)
- Fluorescence sensor (1)
- Fluorescence sensors (1)
- Fluoreszenzlöschung (1)
- Fluoreszenzsensoren (1)
- Flying platforms (1)
- Frequency response (1)
- GC-MS (1)
- Gas detector (1)
- Gas dispersion simulation (1)
- Gas distribution modeling (1)
- Gas distribution modelling (1)
- Gas measurement (1)
- Gas storage sites (1)
- Gas tomography (1)
- Gasdetektion (1)
- Gasfreisetzung (1)
- Gasquellenlokalisierung (1)
- Gassensor (1)
- Gassensorik (1)
- Gasspeicher (1)
- Gefahrenszenarien (1)
- Gefahrstoffe (1)
- Gefährdungsbeurteilung (1)
- Glasspeicher (1)
- H2Safety@BAM (1)
- Hochdynamische Untersuchungen (1)
- Hopkinson Bar (1)
- Hopkinson pressure bar (1)
- Hopkinson-Stab (1)
- Hopkinsonstab (1)
- Humidity sensors (1)
- Hydraulic levelling system (1)
- Hydrogen (1)
- Hydrogen technology (1)
- Härtevergleichsplatten (1)
- Impact (1)
- Inertial measurement unit (1)
- Inertial navigation system (1)
- Instrumentierte Eindringprüfung (1)
- Intumescence (1)
- Ion mobility spectrometry (1)
- Klebstoffe (1)
- KonSens (1)
- Koordinatenmessung (1)
- Kraftabhängige Funktion (1)
- Ladungssicherung (1)
- Ladungsssicherung (1)
- Lamb-waves (1)
- Laser-based displacement measuring system (1)
- Leak detection (1)
- Leakage (1)
- Luftfrachtsicherheit (1)
- Magneto-optischer Sensor (1)
- Maschinennachgiebigkeit (1)
- Measurement (1)
- Measurement uncertainty (1)
- Membrane-based linear gas sensor (1)
- Mesh routing (1)
- Methane measuring (1)
- Micro UAV (1)
- Micro-drone (1)
- Mini-UAV (1)
- Mobile Sensorik (1)
- Mobile sensors (1)
- Moisture measurements (1)
- Multi-Hop WSN (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multi-sensor device (1)
- Multichannel measuring (1)
- Multigassensoren (1)
- Multihop (1)
- Multirotor aircraft (1)
- Nano UAV Swarm (1)
- Nanocomposites (1)
- New sensor principles (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Nitroaromaten (1)
- Non-destructive evaluation (1)
- Odor localization (1)
- Olfaction (1)
- PVD-Haftfestigkeit (1)
- Passive sensor interface (1)
- Pattern recognition methods (1)
- Permeation (1)
- Permeation method (1)
- Person tracking (1)
- Phototransistor (1)
- Piezoresistive accelerometers (1)
- Plume (1)
- Power-to-Gas (1)
- Prototyp (1)
- Prüfung (1)
- QI Digital (1)
- Quality Infrastructure (1)
- Quantification of gas concentrations (1)
- RAM packages (1)
- RFID Sensor systems (1)
- RFID based sensors (1)
- RFID sensors systems (1)
- RFID Sensors systems (1)
- Radioactive (1)
- Reactive plume tracking (1)
- Red Phosphorus (1)
- Remote gas sensing (1)
- Remote gas sensor model (1)
- Remote sensing (1)
- Richtlinie (1)
- Risikoanalyse (1)
- SHT (1)
- Schadenfrüherkennung (1)
- Selbstkalibrierung (1)
- Selective permeability (1)
- Sensor (1)
- Sensor calibration and validation (1)
- Sensor planning (1)
- Sensorik (1)
- Sensorvalidierung (1)
- Single cable system (1)
- Small-scale Cone Calorimeter Untersuchungen (1)
- Soil test field (1)
- Spatially distributed monitoring (1)
- Sphärische Indenter (1)
- Strain measurements (1)
- Structural Health Monitoring (1)
- Structural Health Monitoring (SHM) (1)
- Structure health monitoring (1)
- System adhesive/ strain gauge (1)
- Technische Infrastruktur (1)
- Technische Überwachung (1)
- Temperaturabhängige Prüfung (1)
- Temperature behavior (1)
- Temperature and Frequency Compensation (1)
- Temperature behavior (1)
- Temperature behavior of a piezoresistive accelerometer (1)
- Temperature calibration (1)
- Temperature dependent and high dynamic load tests (1)
- Temperaturkompensation (1)
- Test (1)
- Test gas generation (1)
- Thrust (1)
- Trail detection (1)
- Trail following (1)
- Tribologie (1)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS); UAV-REGAS (1)
- Tunable diode laser absorption Spectroscopy (TDLAS) (1)
- UAS (1)
- UHF antenna (1)
- Ultrasound (1)
- Urban air monitoring (1)
- Vereinfachtes Verfahren (1)
- Verschiebungsfeld (1)
- Verteilte Sensorik (1)
- WLAN (1)
- WSN (1)
- Wasserstofferzeugung (1)
- WiFi (1)
- Wind (1)
- Wind speed and direction (1)
- Wind vector (1)
- Windvektorbestimmung (1)
- Wireless sensor network (WSN) (1)
- Wischprobenahme (1)
- binäres Regressionsverfahren (1)
- pH-Sensor (1)
- polymeren Baustoffen (1)
- poultry odorous air monitoring (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (50)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (50)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (6)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 1.9 Chemische und optische Sensorik (3)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 6 Materialchemie (2)
- 6.7 Materialsynthese und Design (2)
Eingeladener Vortrag
- nein (33)
This presentation gives an introduction to the gas-sensitive aerial robots developed at BAM, including various application examples in the field of mobile robot olfaction: gas source localization and gas distribution mapping.
Nitroaromaten und insbesondere Trinitrotoluol (TNT) sind weit verbreitete Spreng- und Umweltschadstoffe. Die größte Herausforderung bei der Detektion von TNT in der Gasphase ist der geringe Dampfdruck. Derzeit werden vielerorts günstige, schnelle, handliche und einfach zu bedienende Alternativen zur klassischen TNT-Analytik entwickelt. Aktuell existieren keine einheitlichen Richtlinien für Sprengstoffsensoren. Hier wird die Entwicklung eines Messplatzes zur Validierung von Sprengstoffsensoren sowie die Erprobung eines kompakten Mustersensors vorgestellt.
Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol 1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
IMS trägt zur Luftfrachtsicherheit bei
Geltende Luftsicherheitsgesetze verpflichten Luftsicherheitsbehörden, Flughafenbetreiber und Fluggesellschaften umfassende Sicherheitsmaßnahmen auf den Flughäfen zu ergreifen, um die Gefahr möglicher terroristischer Bedrohungen zu erkennen und zu verhindern. Wenn ein verdächtiges Objekt durch Röntgenstrahlen identifiziert wurde, kann die IMS als schnelles Analyseverfahren vor Ort orthogonal zur Radiologie eingesetzt werden, um chemische Informationen über Gefahrstoffe wie Sprengstoffe oder Drogen vor dem Abflug zu erhalten.
Vor der Detektion von Sprengstoffen beginnt die Untersuchung eines verdächtigen Objekts mit der Probenahme mittels Wischprobensammlern. Eine Luftsicherheitskontrollkraft wischt dabei Oberflächen des Objekts mit einem Probensammler ab, um Partikel von Gefahrstoffen zu sammeln. Der beladene Probensammler wird anschließend in einen Probeneinlass eingeführt. Nach thermischer Desorption der gesammelten Stoffe erhält der Bediener (z. B. Luftsicherheitskontrollkraft) ein boolesches Ergebnis - "Alarm" oder "Kein Alarm".
Verfahren und Ergebnisse
In dieser Studie wurden drei Verfahren mit vier ECAC-zertifizierten ETD-Geräten zur Entwicklung eines Unsicherheitskonzeptes bezüglich der Probenahme (PN) angewandt:
I) direkte Probenaufnahme durch lösemittelbasierten Auftrag einer bekannten Sprengstoffmenge auf einem Probensammler,
II) Auftragung einer bekannten Menge eines gelösten Sprengstoffs auf einem 10 cm × 10 cm Substrat (Aluminium, Papier, Eisen und Polyvinylchlorid) und manuelle PN nach Lösemittelverdampfung,
III) lösemittelbasierter Sprengstoffauftrag auf eine PTFE- oder PTFE-beschichtete Glasfaseroberfläche, nach Lösemittelverdunstung trockene Übertragung auf das zu beprobende Substrat zur PN.
Nach dem binären Regressionsverfahren wurde die funktionale Abhängigkeit der Detektionswahrscheinlichkeit von einer bekannten Sprengstoffmasse mit einer Logit-Funktion beschrieben:
POD=1/(1+e^(-A·(m-B))).
Dabei ist POD die Wahrscheinlichkeit der Detektion für eine bekannte Sprengstoff-Masse, die Parameter A (logistische Wachstumsrate der Kurve) und B (m-Wert des Mittelpunktes des Sigmoids) sind geschätzte Parameter nach der Methode der kleinsten Quadrate, und m ist die Sprengstoffmasse.
Das entwickelte Messunsicherheitsmodell kombiniert quantitative Ergebnisse aus Wägen, Lösen und Pipettieren sowie qualitative Ergebnisse - "Alarm" oder "Kein Alarm" und die Unsicherheit der PN. Identifizierte Unsicherheitsursachen sind die Durchführung der Wischprobenahme, Staub, Lösemitteleffekte und die Unsicherheit bei der Herstellung von Testlösungen.
IMS trägt zur Luftfrachtsicherheit bei Luftsicherheitsgesetze verpflichten Luftsicherheitsbehörden, Flughafenbetreiber und Fluggesellschaften umfassende Sicherheitsmaßnahmen auf den Flughäfen zu ergreifen, um Gefahren z. B. durch potenziell gefährliche Frachtgüter zu erkennen. Von der Europäische Zivilluftfahrt-Konferenz (ECAC) zertifizierte IMS-Geräte werden vor Ort an den Kontrollpunkten orthogonal zur Radiologie eingesetzt, um chemische Informationen von verdächtiger Fracht über Gefahrstoffe wie Sprengstoffe oder Drogen vor dem Verladen zu erhalten.
Vor der Detektion von Sprengstoffen beginnt die Untersuchung eines verdächtigen Objekts mit der Probenahme mittels Wischprobensammlern. Eine Luftsicherheitskontrollkraft wischt dabei Oberflächen des Objekts mit einem Probensammler ab, um Partikel von Gefahrstoffen zu sammeln. Der beladene Probensammler wird anschließend in einen Probeneinlass eingeführt. Nach thermischer Desorption der gesammelten Stoffe erhält der Bediener (z. B. Luftsicherheitskontrollkraft) ein boolesches Ergebnis - "Alarm" oder "Kein Alarm".
Verfahren und Ergebnisse
In dieser Studie wurden drei Verfahren mit vier ECAC-zertifizierten ETD-Geräten zur Identifizierung und Beurteilung der Probenahme (PN) entwickelt:
I) direkte PN durch lösemittelbasierten Auftrag einer bekannten Sprengstoffmenge auf einem Probensammler,
II) Auftrag einer bekannten Menge eines gelösten Sprengstoffs auf einem 10 cm × 10 cm Substrat (Aluminium, Papier, Eisen und Polyvinylchlorid) und manuelle PN nach Lösemittelverdampfung,
III) lösemittelbasierter Sprengstoffauftrag auf eine PTFE- oder PTFE-beschichtete Glasfaseroberfläche, nach Lösemittelverdunstung trockene Übertragung auf das zu beprobende Substrat zur PN.
Der Zusammenhang zwischen vorgelegter Sprengstoffmenge und der Detektionswahrscheinlichkeit (POD) erfolgt durch Anwendung des binären Regressionsverfahrens mit einer Logit-Funktion:
POD=1/(1+exp(-A(m-B)) )·100%
Dabei entspricht m der vorgelegten Sprengstoffmasse bis 1000 ng, Parameter A / ng-1 der logistischen Wachstumsrate der Kurve und Parameter B / ng dem m-Wert des Mittelpunktes des Sigmoids. Die Bestimmung der Parameter wurde nach der Methode der kleinsten Quadrate berechnet.
Das entwickelte Messunsicherheitsmodell kombiniert quantitative Ergebnisse aus Stammlösung und deren Verdünnungen sowie Stoffauftrag und qualitative Ergebnisse nach Anzeige "Alarm" oder "Kein Alarm". Dieses Auswerteverfahren wurde auf die Probenahme angewandt. Identifizierte Unsicherheitsursachen sind die Durchführung der Wischprobenahme, Staub, Lösemitteleffekte und die Unsicherheit bei der Herstellung von Testlösungen.
Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol-1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
In the near future, it will be important to adopt innovative approaches and technologies in order to further guarantee the reliability and availability of the highway network. New tools are therefore needed in order 'to obtain in-depth information about the condition of bridges and its development early enough before significant, precarious damage cases occur. In 2011, the research program "Intelligente Brücken (Smart Bridges)" was launched by the BASt together with the BMVI to evolve systems for information and holistic evaluation for bridge structures as a supplement to the current inspection-based maintenance management. Several projects dealt with the topic in the last few years and provided guidelines and a solid basis to move towards a first implementation considering the input of all research projects carried out so far.
To quantify the moisture in concrete, RFID based humidity sensors are embedded. Passive high frequency, ultra-high frequency RFID tags as well as active Bluetooth sensors are tested. After concreting, all sensors measure the corresponding relative humidity to monitor the concrete moisture. Two case studies are performed, embedding in an existing construction, i.e. the duraBASt test bridge, and embedding in cement based mortar in the laboratory. As basis for robust and long-life sensors in alkaline concrete, different casing materials are tested. Furthermore, signal strength measurements and their sensitivity to different moisture levels are performed.
Sensors integrated into devices and structures provide essential data to control, optimize or manage machines and structural components. In the last years, processes, applications and machine parts became more and more intelligent. Consequently, the need for sensor validation increased significantly in order to rely on sensor data and measurement results.
Structure-integrated fibre optic strain sensors, such as fiber Bragg gratings (FBG), are of special interest in the composite manufacturing industry. This type of sensor makes it possible to gain information and to collect measurement data about entire production processes and whole life-time cycles of composite-made machine parts and structures. However, validation concepts and approaches for this type of sensors are barely reported in literature. Furthermore, all the reported activities have the drawback that the sensor diagnosis strategy is implemented as limited mathematical models and/or complex time-consuming spectral analysis tools which are applied in data post-processing loops. However, to automate sensor validation and to apply real-time and in-field sensor fault detection, it is necessary to acquire measurement data and information about the measurement reliability at the same time.
Der Mangel an Anwendungsrichtlinien und Validierungsverfahren für struktur-eingebettete faseroptische Dehnungssensoren, insbesondere auf Faser-Bragg-Gitter (FBG)-Basis, führte bislang dazu, dass diese Sensoren trotz ihrer hervorragenden Eigenschaften im Bereich der kommerziellen Material- und Strukturüberwachung nur in geringem Umfange eingesetzt wurden. Fragen zur Degradation der Sensoren unter Beanspruchung, Alterung durch klimatische Einflüsse und Enthaftung infolge Belastung der Struktur konnten bisher nur theoretisch simuliert oder anhand exemplarischer Proben für einzelne einflussnehmende Parameter im Labor untersucht werden. Die Erfassung des Sensorverhaltens im Bauteil unter komplexen Umwelteinflüssen während des Bauteilbetriebes, um damit eine Aussage zur Zuverlässigkeit der Sensormessdaten zu gewinnen, war bisher nicht möglich.
Im Forschungsprojekt FAMOS² wurde deshalb von 2014 bis 2018 die Realisierung eines Autodiagnoseverfahrens für faseroptische Dehnungssensoren erarbeitet, um die Funktionszuverlässigkeit und Langzeitstabilität der Sensoren während des Bauteilbetriebes innerhalb einer Bauteilstruktur bewerten zu können. Im Rahmen des Forschungsprojektes wurde gezeigt, dass ein FBG-Sensor mit einer speziell angepassten magnetostriktiven Schicht magnetisch so angeregt werden kann, dass mit einer zugeschnittenen Messmethodik zu jedem Zeitpunkt eine Bewertung der Sensorzuverlässigkeit unter Betriebsbedingungen möglich ist. Die auf den Sensor aufgebrachte magnetostriktive Schicht erzeugt bei Anregung mit einem passenden Magnetfeld eine gepulste, synthetische Dehnung. Diese Dehnung steht in einem definierten Verhältnis zum anregenden Magnetfeld und wird optisch über die Verschiebung der Bragg-Wellenlänge ausgelesen. Die Konstanz dieses Verhältnisses stellt dann ein Maß für die korrekte Funktionsfähigkeit des Sensors dar. Das Beschichtungs-verfahren, das magnetische Anregungs- und optische Ausleseverfahren, wie auch die Validierung des Sensors unter Berücksichtigung faseroptischer Effekte wurden während des Projekts konzeptionell entwickelt, aufgebaut und charakterisiert. Qualitativ kann mit diesem Verfahren zunächst eine Gut-/Schlecht-Beurteilung des Sensors vorgenommen werden. Perspektivisch bietet das Verfahren jedoch auch die Möglichkeit, verschiedene Versagensmechanismen bestimmen und klassifizieren zu können. Es zeichnete sich schon während des Projektverlaufs ab, dass sich aus den erzielten Ergebnissen über das Autodiagnoseverfahren hinaus weitere Anwendungsmöglichkeiten für den Einsatz des kombinierten magnetostriktiv-faseroptischen Sensorprinzips, beispielsweise als reiner Magnetfeldsensor, ergeben.
Nach Abschluss dieses Forschungsprojekts besteht nun die Möglichkeit, den Funktionszustand faseroptischer Dehnungssensoren jederzeit unabhängig von Alter, Belastung oder Kenntnis eines Referenzzustands zu einem bestimmten Zeitpunkt bestimmen zu können. Aufbauend auf diesen Ergebnissen können weiterführende Forschungen die Messmethodik vertiefend charakterisieren und weitere Anwendungsfälle erschließen.
The exploration of condensed phase mechanisms such as charring and intumescence has been pushed forward in the last decades, since it is believed that focusing on these concepts will bring materials closer to an efficient and ecologically friendly fire retardancy. They promise to concentrate efficient fire retardancy at the key position between pyrolysis zone and gas phase. Examples of residue/char forming and intumescent materials are used to illustrate the influence of mass and heat barrier effects on the fire behavior of materials and general results are presented. A comprehensive understanding of the mechanisms and structure-property relationships in fire retardancy is presented.
Eine Reihe von Prüfproblemen in der chemischen Industrie, in Kraftwerksanlagen und in Transportsystemen ist aufgrund schwieriger Zugangsmöglichkeiten nur begrenzt technisch bzw. wirtschaftlich effizient durchführbar. Das hier vorgestellte Projekt beinhaltet die Entwicklung eines Verfahrens der zerstörungsfreien Prüfung über weite Entfernungen (bis zu 100 m), das zum Einsatz in automatisierten Messsystemen bzw. zur Integration in Langzeitüberwachungssysteme geeignet ist. Grundlage des Verfahrens ist die gezielte Anregung und Auswertung von Lamb-Wellenmoden, wodurch eine effektive Unterscheidung von Fehler- und Formanzeigen sowie eine Klassifizierung unterschiedlicher Fehlertypen möglich werden.
Der Vorteil der Nutzung geführter Wellen für die zerstörungsfreie Prüfung liegt in ihrer vergleichsweise guten Ausbreitungsfähigkeit über weite Entfernungen. Die sich daraus ergebenden Möglichkeiten der Untersuchung großer bzw. schwer zugänglicher Bereiche einer Struktur bieten innovative Ansätze für die Entwicklung robuster Structural-Health-Monitoring-Systeme (SHM). Erst durch die Verfügbarkeit leistungsfähiger Rechentechnik wird ein breiter Einsatz derartiger Verfahren möglich. Die Technik kann zur Materialcharakterisierung an ebenen bzw. zylindrischen, dünnwandigen Flächen aus Metall oder auch CFK genutzt werden. Adressierte Anwendungsfelder sind z.B. die Untersuchung von Flugzeugtragflächen oder Pipelines. Des Weiteren wird der Einsatz solcher Verfahren zur Überwachung sicherheitsrelevanter Bauteile z.B. aus Laminaten angestrebt, wie sie verstärkt in der Luft- und Raumfahrt Anwendung finden. Im Rahmen des Projekts wurde auf Grundlage vorhandener Technik (Wellenanregung mittels Ultraschall-Gruppenstrahlprüfköpfen) ein umfassendes Verständnis für die Technologie und anwendungsrelevante Parameter (Probenmaterial und -dimensionen, Welleneigenschaften, Anregungs-, Transmissions-, Reflektionscharakteristika) gewonnen und Algorithmen zur Erkennung von Schädigungsbildern (z.B. Riss, Loch, Verdünnung) entwickelt.
Neben der Algorithmusentwicklung zur Detektion und Analyse von Schadstellen, lag ein Projektschwerpunkt in der Entwicklung einer geeigneten Gerätetechnik. Als sensorisches Elemente wurde Ultraschall-Gruppenstrahlertechnik eingesetzt. Besondere Anforderungen werden an die Technik zur Anregung der Wellenmoden unter Verwendung geeigneter Piezoaktoren gestellt. In diesem Bereich existiert bislang keine kommerziell erhältliche Gerätelösung, weshalb eine Neuentwicklug der Anregetechnik realisiert wurde. Speziell für die hohe Anzahl an Aktorkanälen, die benötigt wird, um unterschiedliche Moden und Wellenformen anzuregen, wurde eine äußerst leistungsfähige Anregeeinheit entwickelt.
BAM Federal Institute for Materials Research and Testing, in cooperation with the company MeGaSen UG carries out a research project to enhance and validate an innovative approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane-based gas measurement technology for in-situ monitoring of gases in soil and fiber optical sensing of temperature and strain (as a measure for structural change). Key aspect of the research project is the first-time validation of the system in an application relevant dimension. For this purpose a 20 x 20 m2 test field is build. A comprehensive validation of the system is carried out by systematic variation of different parameters like position-dependent gasinjection, temperature and mechanical impact.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
This work presents first results from repetitive CO2 injection experiments performed on a recently built-up 400 m² soil test field with gas injection system. The test field contains 48 membrane-based linear gas sensors that were installed in several depths of the test field. Sensors for measuring meteorological parameters (e.g., wind / rain) and the parameters soil temperature, soil moisture, and groundwater level were installed additionally.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
In industrial environments, airborne by-products such as dust and (toxic) gases, constitute a major risk for the worker’s health. Major changes in automated processes in the industry lead to an increasing demand for solutions in air quality management. Thus, occupational health experts are highly interested in precise dust and gas distribution models for working environments. For practical and economic reasons, high-quality, costly measurements are often available for short time-intervals only. Therefore, current monitoring procedures are carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only. Real-time knowledge of contaminant distributions inside the working environment would also provide means for better and more economic control of air impurities. For example, the possibility to regulate the workspace’s ventilation exhaust locations can reduce the concentration of airborne contaminants by 50%.
To improve the occupational health and safety of (industrial) workplaces, this work aims for developing a swarm of gas-sensitive aerial nano robots for monitoring indoor air quality and for localizing potential emission sources.