Filtern
Erscheinungsjahr
- 2020 (5) (entfernen)
Dokumenttyp
Referierte Publikation
- nein (5) (entfernen)
Schlagworte
- Air quality (1)
- Air quality monitoring (1)
- Calibration of electrical quantities (1)
- Calibration of force (1)
- Calibration of temperature (1)
- ETD (1)
- Emmbedded sensor (1)
- Environment (1)
- IMS (1)
- Ionenmobilitätsspektrometrie (1)
- LoRaWAN (1)
- Long term monitoring (1)
- Measurement uncertainty (1)
- Multisensor system (1)
- New sensor principles (1)
- Passive RFID (1)
- SHT (1)
- Sensors (1)
- Smart sensors (1)
- Smart structures (1)
- Spectroscopy (1)
- Sprengstoffspurendetektion (1)
- VOC (1)
- Wischprobenahme (1)
- binäres Regressionsverfahren (1)
Organisationseinheit der BAM
- 8.1 Sensorik, mess- und prüftechnische Verfahren (5) (entfernen)
IMS trägt zur Luftfrachtsicherheit bei
Geltende Luftsicherheitsgesetze verpflichten Luftsicherheitsbehörden, Flughafenbetreiber und Fluggesellschaften umfassende Sicherheitsmaßnahmen auf den Flughäfen zu ergreifen, um die Gefahr möglicher terroristischer Bedrohungen zu erkennen und zu verhindern. Wenn ein verdächtiges Objekt durch Röntgenstrahlen identifiziert wurde, kann die IMS als schnelles Analyseverfahren vor Ort orthogonal zur Radiologie eingesetzt werden, um chemische Informationen über Gefahrstoffe wie Sprengstoffe oder Drogen vor dem Abflug zu erhalten.
Vor der Detektion von Sprengstoffen beginnt die Untersuchung eines verdächtigen Objekts mit der Probenahme mittels Wischprobensammlern. Eine Luftsicherheitskontrollkraft wischt dabei Oberflächen des Objekts mit einem Probensammler ab, um Partikel von Gefahrstoffen zu sammeln. Der beladene Probensammler wird anschließend in einen Probeneinlass eingeführt. Nach thermischer Desorption der gesammelten Stoffe erhält der Bediener (z. B. Luftsicherheitskontrollkraft) ein boolesches Ergebnis - "Alarm" oder "Kein Alarm".
Verfahren und Ergebnisse
In dieser Studie wurden drei Verfahren mit vier ECAC-zertifizierten ETD-Geräten zur Entwicklung eines Unsicherheitskonzeptes bezüglich der Probenahme (PN) angewandt:
I) direkte Probenaufnahme durch lösemittelbasierten Auftrag einer bekannten Sprengstoffmenge auf einem Probensammler,
II) Auftragung einer bekannten Menge eines gelösten Sprengstoffs auf einem 10 cm × 10 cm Substrat (Aluminium, Papier, Eisen und Polyvinylchlorid) und manuelle PN nach Lösemittelverdampfung,
III) lösemittelbasierter Sprengstoffauftrag auf eine PTFE- oder PTFE-beschichtete Glasfaseroberfläche, nach Lösemittelverdunstung trockene Übertragung auf das zu beprobende Substrat zur PN.
Nach dem binären Regressionsverfahren wurde die funktionale Abhängigkeit der Detektionswahrscheinlichkeit von einer bekannten Sprengstoffmasse mit einer Logit-Funktion beschrieben:
POD=1/(1+e^(-A·(m-B))).
Dabei ist POD die Wahrscheinlichkeit der Detektion für eine bekannte Sprengstoff-Masse, die Parameter A (logistische Wachstumsrate der Kurve) und B (m-Wert des Mittelpunktes des Sigmoids) sind geschätzte Parameter nach der Methode der kleinsten Quadrate, und m ist die Sprengstoffmasse.
Das entwickelte Messunsicherheitsmodell kombiniert quantitative Ergebnisse aus Wägen, Lösen und Pipettieren sowie qualitative Ergebnisse - "Alarm" oder "Kein Alarm" und die Unsicherheit der PN. Identifizierte Unsicherheitsursachen sind die Durchführung der Wischprobenahme, Staub, Lösemitteleffekte und die Unsicherheit bei der Herstellung von Testlösungen.
The present paper describes the development of a sensor material that changes its fluorescence in the presence of gaseous ammonia in a relevant concentration range. The implementation into a semi-automatic gas measurement device enables low-cost, precise, simple and fast monitoring of low con-centrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
Design and Implementation of Smart Multisensor Monitoring System for Safe Workplaces with LoRaWAN
(2020)
This project addresses the application of safe workplaces in offices and chemical laboratories where indoor air quality plays an important role. The LoRaWAN (Long Range Wide Area Network) is used as a communication interface to make important sensor data globally accessible. The goal of the development is to create a sensor node and an online and offline solution that collects the data from the sensor nodes and stores it on a local server or in a cloud. In cooperation with the companies WISTA GmbH and IONOS, a test sensor network is going to be established in the Berlin-Adlershof area.
Over decades, the German Federal Institute for Materials Research and Testing (BAM) has established a sophisticated calibration laboratory for force, temperature and electrical quantities. Since more than 15 years it is accredited, currently by the national accreditation body (DAkkS), and offers its service also to external entities on a global scale. As a public provider, we are furthermore committed to research and development activities that demand measurements with highest quality and low level of uncertainties. Two R&D examples are highlighted within this contribution.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.