Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (51) (entfernen)
Schlagworte
- Gas storage areas (6)
- Membrane-based gas sensing (6)
- Subsurface monitoring (6)
- Monitoring (5)
- Smart structures (4)
- Structural health monitoring (4)
- Autonomous micro UAV (3)
- Distributed linear sensor (3)
- Distributed sensor (3)
- Drop test (3)
- Electronic nose (3)
- Gas source localization (3)
- Nanocomposites (3)
- Passive RFID (3)
- RFID sensors (3)
- Sensor requirements (3)
- Sensors in concrete (3)
- Aerial robot (2)
- Artificial potential field (2)
- BAM Datenbank Gefahrgut (2)
- Behälter (2)
- Chemical and wind sensing (2)
- Computed tomography (2)
- Cone Calorimeter (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Embedded sensors (2)
- Fallprüfung (2)
- Fire retardancy (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gasmessung (2)
- Gefahrgut (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- Linear sensor (2)
- Localization (2)
- Long-term requirements (2)
- Mikrodrohne (2)
- Mobile robot olfaction (2)
- Multichannel measuring system (2)
- Nano aerial robot (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Particle filter (2)
- Quadrocopter (2)
- RFID (2)
- Sensor planning (2)
- Swarm (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Aerial robot olfaction (1)
- Air-based (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Bauteilintegrierte Sensoren (1)
- Betonkorrosion (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Chemometric techniques (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- Dangerous goods (1)
- Data bus (1)
- Data fusion (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Diagnosis of concrete components (1)
- Discrimination of multiple gas sources (1)
- ECD-Aktorschicht (1)
- Elastoplastic material parameters (1)
- Emission control (1)
- Emissionskontrolle (1)
- Epoxide (1)
- Faseroptik-Sensoren (1)
- Fiber Bragg grating (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fibre optical sensing (1)
- Fibre optical sensing (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluoreszenz (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasquellenlokalisierung (1)
- Hazardous scenarios (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (IMU) (1)
- Intumescence (1)
- Intumescent coating materials (1)
- LOI (1)
- Ladungssicherung (1)
- Ladungsssicherung (1)
- Leakage (1)
- Long term monitoring (1)
- Magnetic field (1)
- Magnetostriction (1)
- Magnetostrictive metal coating (1)
- Mesh routing (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mobile Robot Olfaction (1)
- Mobile Sensorik (1)
- Mobile sensing system (1)
- Monitoring of CO 2 (1)
- Monitoring of CO2 (1)
- Monitoring of dangerous goods (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- PVD-Haftfestigkeit (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID sensors systems (1)
- RFID-Sensorsysteme (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Real-time (1)
- Reinforced concrete (1)
- SHT (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensoren (1)
- Sensors (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smartphone (1)
- Soil test field (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Strain (1)
- Subsurface (1)
- TD-GC-MS (1)
- TDLAS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Tomographic reconstruction of gas plumes (1)
- Trail detection (1)
- Trail following (1)
- Tunable diode laser absorption Spectroscopy (TDLAS) (1)
- UAV (1)
- UAV-REGAS (1)
- UL94 (1)
- Uncertainty (1)
- Validation (1)
- WSN (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- poly(propylene) (PP) (1)
- Öl (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
In this paper, we introduce a nano aerial robot swarm for indoor air quality monitoring applications such as occupational health and safety of (industrial) workplaces. The concept combines a robotic swarm composing of nano Unmanned Aerial Vehicles (nano UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight metal oxide gas sensors for measuring the Total Volatile Organic Compound (TVOC) in ppb and estimating the eCO2 (equivalent calculated carbon-dioxide) concentration in ppm. TVOC is a measure for the indoor air quality. An indoor localization and positioning system will be used to estimate the absolute 3D position of the swarm like GPS. Based on this novel indoor air quality monitoring concept, the development and validation of new algorithms in the field of Mobile Robot Olfaction (MRO) are planned, namely gas source localization and gas distribution mapping. A test scenario will be built up to validate and optimize the gas-sensitive nano aerial robot swarm for the intended applications.
The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.
Concept for investigating mechanical and thermal impacts on distributed subsurface gas monitoring
(2016)
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO 2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas Distribution behavior. In this paper, we briefly describe the setup of a CO 2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m² test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
Geogenic gases from natural sources, carbon dioxide (CO2) from a geological repository (carbon capture and storage - CCS) or a leaking gas pipeline can present serious risks in industrial and urban areas. To extend the lead time for risk treatment in such critical regions, reliable detection of gases within the shallow subsurface is required to observe critical gas accumulations before degassing into the atmosphere.
A near real-time monitoring approach is introduced to determine the volumetric expansion of a leakinggas in the subsurface. Considering the pressure relaxation with the ambient air pressure, the approach enables the forecasting of the final size of a pressurized gas body in terms of characteristic lengths. According to theoretical basics, such a characteristic length, which enables us to perform a gas (safety) measurement based on a purely geometrical measure, behaves independently of subsurface properties,i.e., it enables a reliable quantification of the escaping gas irrespective of its heterogeneous or changingflow path distribution. A field test for a 10 l/min pinhole leakage injected into a 10 m long, 0.4 m wide, 0.95 m deep soil-filled trench that was equipped with linear sensors shows the lateral-vertical volumetric gas expansion along these sensors, and demonstrates the applicability of the characteristic length approach.
Real-time wind estimation on a micro unmanned aerial vehicle using its inertial measurement unit
(2015)
This paper presents an approach for a quadrocoper-based micro unmanned aerial vehicle (UAV) that estimates the wind vector (speed and direction) in real-time based on measurement data of its on-board sensors only. This method does not need any additional airspeed sensor or dedicated anemometer, and thus the micro UAV's valuable payload remains free for other sensors. Wind tunnel and field tests were used to evaluate the performance of the approach. In order to quantify its accuracy, experiments are presented where data was collected with an anemometer placed in an open field with the micro UAV in flight following a predefined trajectory around the anemometer and hovering at a defined position close to it.
One challenge associated with navigating a nano aerial robot swarm indoors in unstructured environments is, i.a., the limited air space. To avoid an over-regulation of the available indoor air space (e.g., prohibit copters to fly above each other), a safety region around each copter must be defined. In this paper, we investigate the impact of the downwash of a nano-drone on the stability of another nearby nano-drone. In the experiments, we found out that this downwash has a negative influence of a second nano-drone in a distance of around 1 m vertically and 0.2 m horizontally. Based on the obtained data, we developed a model describing the above-mentioned safety region to enable a safe operation of the swarm in these environments with fewer constraints.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.