Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (51) (entfernen)
Schlagworte
- Gas storage areas (6)
- Membrane-based gas sensing (6)
- Subsurface monitoring (6)
- Monitoring (5)
- Smart structures (4)
- Structural health monitoring (4)
- Autonomous micro UAV (3)
- Distributed linear sensor (3)
- Distributed sensor (3)
- Drop test (3)
- Electronic nose (3)
- Gas source localization (3)
- Nanocomposites (3)
- Passive RFID (3)
- RFID sensors (3)
- Sensor requirements (3)
- Sensors in concrete (3)
- Aerial robot (2)
- Artificial potential field (2)
- BAM Datenbank Gefahrgut (2)
- Behälter (2)
- Chemical and wind sensing (2)
- Computed tomography (2)
- Cone Calorimeter (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Embedded sensors (2)
- Fallprüfung (2)
- Fire retardancy (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gasmessung (2)
- Gefahrgut (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- Linear sensor (2)
- Localization (2)
- Long-term requirements (2)
- Mikrodrohne (2)
- Mobile robot olfaction (2)
- Multichannel measuring system (2)
- Nano aerial robot (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Particle filter (2)
- Quadrocopter (2)
- RFID (2)
- Sensor planning (2)
- Swarm (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Aerial robot olfaction (1)
- Air-based (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Bauteilintegrierte Sensoren (1)
- Betonkorrosion (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Chemometric techniques (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- Dangerous goods (1)
- Data bus (1)
- Data fusion (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Diagnosis of concrete components (1)
- Discrimination of multiple gas sources (1)
- ECD-Aktorschicht (1)
- Elastoplastic material parameters (1)
- Emission control (1)
- Emissionskontrolle (1)
- Epoxide (1)
- Faseroptik-Sensoren (1)
- Fiber Bragg grating (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fibre optical sensing (1)
- Fibre optical sensing (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluoreszenz (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasquellenlokalisierung (1)
- Hazardous scenarios (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (IMU) (1)
- Intumescence (1)
- Intumescent coating materials (1)
- LOI (1)
- Ladungssicherung (1)
- Ladungsssicherung (1)
- Leakage (1)
- Long term monitoring (1)
- Magnetic field (1)
- Magnetostriction (1)
- Magnetostrictive metal coating (1)
- Mesh routing (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mobile Robot Olfaction (1)
- Mobile Sensorik (1)
- Mobile sensing system (1)
- Monitoring of CO 2 (1)
- Monitoring of CO2 (1)
- Monitoring of dangerous goods (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- PVD-Haftfestigkeit (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID sensors systems (1)
- RFID-Sensorsysteme (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Real-time (1)
- Reinforced concrete (1)
- SHT (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensoren (1)
- Sensors (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smartphone (1)
- Soil test field (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Strain (1)
- Subsurface (1)
- TD-GC-MS (1)
- TDLAS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Tomographic reconstruction of gas plumes (1)
- Trail detection (1)
- Trail following (1)
- Tunable diode laser absorption Spectroscopy (TDLAS) (1)
- UAV (1)
- UAV-REGAS (1)
- UL94 (1)
- Uncertainty (1)
- Validation (1)
- WSN (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- poly(propylene) (PP) (1)
- Öl (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH13 solution for 14 days - 3D-Printer-Polymer was completely resolved - PVC has no noticeable decrease in weight - (VitaPro) glass filter for the sensor protector, has weight loss 2.7% - The epoxy resin has increased by 1.8% due to moisture expansion Different concrete samples were prepared for the validation of the systems. RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
An auto-validation tool for the reliability quantification of materials integrated fiber Bragg grating (FBG) strain sensors have been developed and tested. The FBG strain sensor was jacketed with a magnetostrictive layer based on iron-nickel which, when excited by a specific magnetic field, adds an artificial strain to the sensor. The fixed relationship between magnetic induction and wavelength shift of the FBG strain sensor characterizes the bond strength and adhesion between the sensor and the surrounding structure. Due to an easily applicable magnetic field, it is possible to validate the sensor performance in a non-contact, fast way without disturbing the data-acquisition process.
A 400 m2 soil test field with gas injection system was built up, which enables an experimental validation of linear membrane-based gas sensors – a sensor technology which was developed based on the selective permeation of gases through membranes. Several soil watering and injection experiments with carbon dioxide at different days with varying boundary conditions were performed showing that the sensor behaves mostly insensitive to the environmental conditions investigated, i.e., barometric pressure fluctuations, soil temperature, air temperature and humidity, sun duration, and wind speed. Furthermore, depending on water infiltration, a gas phase displacement could be observed in-situ based on the changed measurement signal. The results of the validation experiments highlight the potential of the method for rapid leak detection and localization qualifying the sensor particularly for safety applications, e.g., in underground gas storage areas.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Wyciek metanu (CH4) z infrastruktury takiej jak rurociągi czy zbiorniki magazynowe ma kluczowe znaczenie dla środowiska oraz stwarza zagrożenie dla bezpieczeństwa ludzi i mienia. Obecnie, po okresie bezawaryjnej eksploatacji, można zaobserwować wzrost liczby incydentów spowodowanych nieszczelnościami rurociągów przesyłowych.
W Polsce szczególnie problematyczne okazują się gazociągi, które powstały dekady temu. W tamtym czasie normy techniczne i przepisy budowlane były łagodniejsze niż obecnie obowiązujące. Integralność tych gazociągów jest trudna do skontrolowania, gdyż na etapie budowy nie zostały one przystosowane do badania tłokami pomiarowymi. Aby sprostać temu wyzwaniu, UDT poszukuje metod umożliwiających szybkie i niezawodne wykrywanie oraz lokalizowanie nieszczelności gazociągów na duże odległości.
In this paper, we introduce a nano aerial robot swarm for indoor air quality monitoring applications such as occupational health and safety of (industrial) workplaces. The concept combines a robotic swarm composing of nano Unmanned Aerial Vehicles (nano UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight metal oxide gas sensors for measuring the Total Volatile Organic Compound (TVOC) in ppb and estimating the eCO2 (equivalent calculated carbon-dioxide) concentration in ppm. TVOC is a measure for the indoor air quality. An indoor localization and positioning system will be used to estimate the absolute 3D position of the swarm like GPS. Based on this novel indoor air quality monitoring concept, the development and validation of new algorithms in the field of Mobile Robot Olfaction (MRO) are planned, namely gas source localization and gas distribution mapping. A test scenario will be built up to validate and optimize the gas-sensitive nano aerial robot swarm for the intended applications.
In this paper, we present and validate the concept of an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) gas sensor with a 3-axis aerial stabilization gimbal for aiming at a versatile octocopter. While the TDLAS sensor provides integral gas concentration measurements, it does not measure the distance traveled by the laser diode’s beam nor the distribution of gas along the optical path. Thus, we complement the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from a set of integral concentration measurements. To allow for a fundamental ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present results showing its performance characteristics and 2D plume reconstruction capabilities under realistic conditions. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO).