Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (51) (entfernen)
Schlagworte
- Gas storage areas (6)
- Membrane-based gas sensing (6)
- Subsurface monitoring (6)
- Monitoring (5)
- Smart structures (4)
- Structural health monitoring (4)
- Autonomous micro UAV (3)
- Distributed linear sensor (3)
- Distributed sensor (3)
- Drop test (3)
- Electronic nose (3)
- Gas source localization (3)
- Nanocomposites (3)
- Passive RFID (3)
- RFID sensors (3)
- Sensor requirements (3)
- Sensors in concrete (3)
- Aerial robot (2)
- Artificial potential field (2)
- BAM Datenbank Gefahrgut (2)
- Behälter (2)
- Chemical and wind sensing (2)
- Computed tomography (2)
- Cone Calorimeter (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Embedded sensors (2)
- Fallprüfung (2)
- Fire retardancy (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gasmessung (2)
- Gefahrgut (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- Linear sensor (2)
- Localization (2)
- Long-term requirements (2)
- Mikrodrohne (2)
- Mobile robot olfaction (2)
- Multichannel measuring system (2)
- Nano aerial robot (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Particle filter (2)
- Quadrocopter (2)
- RFID (2)
- Sensor planning (2)
- Swarm (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Aerial robot olfaction (1)
- Air-based (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Bauteilintegrierte Sensoren (1)
- Betonkorrosion (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Chemometric techniques (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- Dangerous goods (1)
- Data bus (1)
- Data fusion (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Diagnosis of concrete components (1)
- Discrimination of multiple gas sources (1)
- ECD-Aktorschicht (1)
- Elastoplastic material parameters (1)
- Emission control (1)
- Emissionskontrolle (1)
- Epoxide (1)
- Faseroptik-Sensoren (1)
- Fiber Bragg grating (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fibre optical sensing (1)
- Fibre optical sensing (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluoreszenz (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasquellenlokalisierung (1)
- Hazardous scenarios (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (IMU) (1)
- Intumescence (1)
- Intumescent coating materials (1)
- LOI (1)
- Ladungssicherung (1)
- Ladungsssicherung (1)
- Leakage (1)
- Long term monitoring (1)
- Magnetic field (1)
- Magnetostriction (1)
- Magnetostrictive metal coating (1)
- Mesh routing (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mobile Robot Olfaction (1)
- Mobile Sensorik (1)
- Mobile sensing system (1)
- Monitoring of CO 2 (1)
- Monitoring of CO2 (1)
- Monitoring of dangerous goods (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- PVD-Haftfestigkeit (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID sensors systems (1)
- RFID-Sensorsysteme (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Real-time (1)
- Reinforced concrete (1)
- SHT (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensoren (1)
- Sensors (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smartphone (1)
- Soil test field (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Strain (1)
- Subsurface (1)
- TD-GC-MS (1)
- TDLAS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Tomographic reconstruction of gas plumes (1)
- Trail detection (1)
- Trail following (1)
- Tunable diode laser absorption Spectroscopy (TDLAS) (1)
- UAV (1)
- UAV-REGAS (1)
- UL94 (1)
- Uncertainty (1)
- Validation (1)
- WSN (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- poly(propylene) (PP) (1)
- Öl (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Wyciek metanu (CH4) z infrastruktury takiej jak rurociągi czy zbiorniki magazynowe ma kluczowe znaczenie dla środowiska oraz stwarza zagrożenie dla bezpieczeństwa ludzi i mienia. Obecnie, po okresie bezawaryjnej eksploatacji, można zaobserwować wzrost liczby incydentów spowodowanych nieszczelnościami rurociągów przesyłowych.
W Polsce szczególnie problematyczne okazują się gazociągi, które powstały dekady temu. W tamtym czasie normy techniczne i przepisy budowlane były łagodniejsze niż obecnie obowiązujące. Integralność tych gazociągów jest trudna do skontrolowania, gdyż na etapie budowy nie zostały one przystosowane do badania tłokami pomiarowymi. Aby sprostać temu wyzwaniu, UDT poszukuje metod umożliwiających szybkie i niezawodne wykrywanie oraz lokalizowanie nieszczelności gazociągów na duże odległości.
The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.
A 400 m2 soil test field with gas injection system was built up, which enables an experimental validation of linear membrane-based gas sensors – a sensor technology which was developed based on the selective permeation of gases through membranes. Several soil watering and injection experiments with carbon dioxide at different days with varying boundary conditions were performed showing that the sensor behaves mostly insensitive to the environmental conditions investigated, i.e., barometric pressure fluctuations, soil temperature, air temperature and humidity, sun duration, and wind speed. Furthermore, depending on water infiltration, a gas phase displacement could be observed in-situ based on the changed measurement signal. The results of the validation experiments highlight the potential of the method for rapid leak detection and localization qualifying the sensor particularly for safety applications, e.g., in underground gas storage areas.
The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity.
The combination of RFID tags and energy efficient sensors offers promising potential for identification, diagnosis, and monitoring applications - particularly when it comes to objacts, which require continuous observation and which are difficult to access with conventional tools. This paper presents two examples as an outlook for RFID sensor systems in embedded structures and in mobile applications.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
Thermogravimetry (TG), thermogravimetry coupled with mass spectroscopy (TG-MS) and thermogravimetry coupled with Fourier transform infrared spectroscopy (TG-FTIR) were used to characterise the thermo-oxidative behaviour of two intumescent coating materials. The temperature dependence, the corresponding volatile products and the amount of residue of the different processes were determined. Using both TG-MS and TG-FTIR results in an unambiguous interpretation of the volatile products. Characteristics such as the influence of endothermic reactions, the release of non-flammable gases, the dehydrogenation enhancing the char formation and the stability of the cellular char were discussed in detail. It was demonstrated, that TG, TG-MS and TG-FTIR are powerful methods to investigate mechanisms in intumescent coatings and that they are suitable methods in respect to quality assurance and unambiguous identification of such materials.
Ständig überwacht
(2012)
The cone calorimeter has become one of the most important and widely used instruments for the research and development of fire retarded polymeric materials. The paper addresses three important ways in which the principal setup influences the results factors which sometimes do not receive due consideration when drawing conclusions. The paper discusses in detail the impact on cone calorimeter results of the choice of external heat flux, the influence on the peak of heat release rate of sample thickness and thermal feedback from the back of the sample, and the influence on irradiance of the horizontal and vertical distances from the cone heater.
Barrier formation and increasing the melt viscosity are addressed as the two main general fire retardancy mechanisms of polymer nanocomposites. They result in specific impacts on fire properties that consequentially cause varying flame retardancy efficiency in different fire tests. The barrier formation retards mainly flame spread (peak of heat release rate) in developing fires, but does not reduce fire load (total heat evolved), ignitability or flammability (limiting oxygen index, UL 94). Furthermore, this flame retardancy effect increases with increasing irradiation and vanishes with decreasing irradiation. The increased melt viscosity prevents dripping, which is beneficial or disadvantageous depending on the fire test used. In some test, it become the dominant influence, transforming self-extinguishing samples into flammable materials or causing wicking. Advantages and the limits are sketched comprehensively for exploiting the main general fire retardancy mechanisms of polymer nanocomposites. It is concluded that barrier formation and changing the melt viscosity in nanocomposites are not sufficient for most applications, but must be accompanied by additional mechanisms in special systems or in combination with other flame retardants.