Damages in infrastructure due to moisture amount to billions of Euros every year. For a more predictive structural health monitoring in civil engineering, the detection and monitoring of hazardous moisture in steel reinforced concrete constructions is of high interest. The sensors have to be wireless, elsewise they weaken the concrete cover of the rebars. The lifetime of such constructions is normally decades, thus the sensors have to be battery-free and fully passive. Considering these requirements, passive RFID-based sensors are developed. Communication and energy supply are realized wireless via the electromagnetic field of a RFID transmitter. The passive RFIDbased sensors are embedded into the concrete to enable the monitoring of moisture transport in porous materials. Results of the hydration process are shown.
Embedded wireless sensor systems for long-term SHM and corrosion detection in concrete components
(2017)
State-of-the-art communication standards like RFID and Bluetooth Low Energy enable the development of sensor systems which can be completely embedded into concrete components for long-term SHM and early damage detection. Objective of the project KonSens which is carried out at BAM is the development, implementation, and validation of sensors for measuring of Parameters relevant for corrosion, like moisture, pH value, and electrical conductivity, inside steel reinforced concrete components. The primarily addressed application is detection and evaluation of corrosion processes in concrete bridges.
In contrast to cable connected sensors, embedded wireless sensors avoid any pathways for intrusion of moisture and chemicals, e.g., chlorides which could trigger corrosion activity. To allow for long-term, ideally life-time operation, the once embedded sensor systems must work highly energy efficient. One option are passive RFID sensor systems, which work without battery. The energy is transmitted to the system through the electromagnetic field, even to operate sensors. A crucial parameter is the transmission depth in concrete. First experiments with RFID sensors working at frequencies of 13.56 MHz (HF) and 868 MHz (UHF) embedded in concrete specimen resulted positive for transmission depths of up to 13 cm, which is quite promising, considering that corrosion would appear first at the top level of rebars.
A second generation of passive RFID sensor systems has been implemented with improved antenna design. Current experiments using these systems focus on the Transmission characteristics in terms of transmission depths and the impact of concrete moisture. Low-energy humidity sensors are used and analysed regarding their capability for measuring the material moisture. Additionally, a relation between transmitted power to the embedded sensor and the moisture content of the concrete specimen caused by energy absorption can be presumed and is under systematic investigation.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
This paper is a further research on the topic of the complete embedding of radio frequency identification (RFID) sensors in concrete. The focus is on the antenna of the transponder. Earlier investigations of different RFID technologies, embedded in concrete, showed a difference in energy transmission. The transmission through concrete at ultra high frequency (UHF), in spite of the large signal range, does not match the targeted application specific task. Therefore, the antenna characteristics have been examined more closely. The antenna is an important component for the application of RFID. Through the antenna, energy and data transfer takes place, so it is important to design an optimal antenna to accomplish a maximum embedding depths in concrete. To identify the optimal antenna geometry, different UHF antenna types were selected and investigated. An experimental comparison was performed to gain more information about the damping behavior and antenna characteristics in concrete.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.