In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures. The method is based on a ratiometric measurement principle, exploiting the pH sensitive colour switching of thymol blue in the basic pH regime and the emissive properties of two different (Zn)CdSe/ZnS core shell quantum dots. The transition point of thymol blue in a Hydrogel D4 matrix was determined to be at around pH 11.6, which fits ideally to the intended application. Next to the fundamental spectroscopic characterization of the ratiometric response, a new design for a sensor head, suitable for the incorporation into concrete matrices is presented. Toward this, a manufacturing process was developed which includes the preparation of a double layer of polymers containing either thymol blue or a quantum dot mixture inside a porous ceramic tube. Results of a proof-of-priciple performance test of the sensor head in solutions of different pH and in cement specimens are presented, with encouraging results paving the way for future field tests in concrete.
Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.----------------------------------------------------------------------------------------------------------------------------------------------------------------
Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen.
One of the main unsolved issues of CCS is the comprehensive surveillance of CO2 storage areas with reasonable effort and costs. This study presents an approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane based measurement technology for in situ monitoring of gases in soil and fibre optical sensing of temperature and strain (as a measure for structural change). A test field of application-relevant dimensions is built up to validate and optimize the technology.
Polymeric nanocomposites are discussed as one of the most promising advanced materials whose nanoscale effects can be exploited for industry. Layered silicate polypropylene-graft-maleic anhydride nanocomposites are investigated as a model to clarify the potential of such materials in terms of fire retardancy. The nanostructure is characterized using transmission electron microscopy (TEM) and shear viscosity. The fire behavior is characterized using different external heat fluxes in cone calorimeter, limiting oxygen index and UL 94 classification. A comprehensive fire behavior characterization is presented which enables an assessment of the materials’ potential with respect to different fire scenarios and fire tests. The influence of morphology and the active mechanisms are discussed, such as barrier formation and changed melt viscosity. To our knowledge, it is the first attempt to illuminate the concept’s strengths, such as the reduction of flame spread, and weaknesses, such as the lack of influence on ignitability, in a clear, comprehensive and detailed manner.
A method was developed to assess the heat insulation performance of intumescent coatings. The method consists of temperature measurements using the bench-scaled experimental set-up of a cone calorimeter and finite difference simulation to calculate the effective thermal conductivity dependent on time/temperature. This simulation procedure was also adapted to the small scale test furnace, in which the standard time-temperature curve is applied to a larger sample and thus which provides results relevant for approval. Investigations on temperature and calculated effective thermal conduction were performed on intumescent coatings in both experimental set-ups using various coating thicknesses. The results correspond to each other as well as showing the limits of transferability between both fire tests. It is shown that bench-scaled cone calorimeter tests are a valuable tool for assessing and predicting the performance of intumescent coatings in larger tests relevant for approval. The correlation fails for processes at surface temperatures above 750°C, which are not reached in the cone calorimeter, but are attained in the small scale furnace set-up.
Polymeric intumescent coatings are fire protective materials that increase their thermal resistance when exposed to high temperatures to prevent building structures from damage. The idea of the investigation was to develop a simple test method to determine the time dependent thermal conductivity of intumescent coatings. Therefore steel plates were coated with two different intumescent systems. During cone calorimeter tests the temperature at the back side of the coated plates was measured. These results were used to calculate the time dependent thermal resistance of the protective layer with the simulation program IOPT2D for different external heat fluxes and different layer thickness.
Zur Untersuchung der Sicherheit von Behältern für den Transport und die Lagerung von Gefahrstoffen und -gütern werden Fallprüfungen durchgeführt. Die Aufpralldynamik und die strukturmechanischen Einwirkungen auf den Behälter werden mittels Beschleunigungsaufnehmern und Dehnungsmessstreifen erfasst. Dabei kommen derzeit Vielkanalmesssysteme zum Einsatz, die eine Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums erfordern, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. Die Verwendung eines Messsystems mit Datenbus und dezentraler Datenspeicherung bietet diesbezüglich einen vielversprechenden Lösungsansatz.
The influence of different organobentonites on the decomposition and the combustion behaviour of an epoxy resin were examined. The epoxy resin is a cationically polymerised cycloaliphatic epoxy resin flexibilised with poly(tetrahydrofuran) (PTHF), with hydroxyl endgroups. The bentonite was modified with either an ammonium or a phosphonium salt. The thermal decomposition of the PTHF induced by the initiator, used for the cationic polymerisation, did neither take place for the nanocomposite based on the ammonium bentonite nor for that based on the phosphonium bentonite. This improved decomposition characteristic lead to a larger time to ignition for both kinds of nanocomposites compared to the not modified polymer, which is not the case for other polymer/clay nanocomposites described in the literature. The fire behaviour was investigated using limiting oxygen index (LOI), a horizontal burner test and a cone calorimeter. The forced flaming conditions in the cone calorimeter were varied using different external heat fluxes between 30 and 70 kW · m-2. The fire behaviour of the nanocomposites was improved in comparison to the polymer, and phosphonium bentonite was superior to ammonium bentonite. The main mechanism is a barrier formation resulting in a reduction of the fire growth rate, which was more pronounced in the case of high external heat fluxes.