Filtern
Dokumenttyp
- Posterpräsentation (5)
- Vortrag (4)
- Beitrag zu einem Tagungsband (1)
Referierte Publikation
- nein (10)
Schlagworte
- Self-healing (6)
- PDMS (3)
- Capsules (2)
- Fluorescent polymer optical fibres (2)
- High voltage cable accessories (2)
- Partial discharge detection (2)
- Silicone rubber (2)
- HV cable accessories (1)
- Micropatterned dry adhesive (1)
- Selbstheilend (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (4)
Mechanically Reinforced Silicone Rubber by Surface Functionalized Polyorganosiloxane Nanoparticles
(2015)
Self-healing polymers
(2016)
This talk gives an overview about self-healing polymers. A classification of the three self-healing approaches “capsule based”, “vascular” and “intrinsic” self-healing is explained. Research in these fields is demonstrated by showing current work from different research groups. Followed by an outlook of non-polymeric self-healing in the field of concrete and asphalt. The talk ends with a short overview of prospective applications.
To avoid a catastrophic failure of insulation in high-voltage (HV) applications, a monitoring of partial discharges (PDs) is necessary. Fluorescently labelled polymer optical fibers (F-POF) offer an electrically passive method for PD detection in HV facilities. F-POFs could be embedded in HV cable accessories, which are usually made of silicone rubber. Herein they detect the light emitted by the PD and convert it into an electrical signal that can be monitored. Due to the difficult accessibility of HV cable accessories, a self-healing silicone rubber with prolonged service life after PD detection represents an attractive material design for HV accessories. With this contribution, we would like to present and discuss the possibilities of combining self-healing materials with POF-based sensors for PD detection in HV applications.
To avoid a catastrophic failure of insulation in high-voltage (HV) applications, a monitoring of partial discharges (PD) is necessary. Fluorescently labelled polymer optical fibres (F-POF) offer an electrically passive method for PD detection in HV facilities. F-POF could be embedded into HV cable insulation material, which are usually made of silicone rubber. Due to the difficult accessibility of HV cable accessories, a self-healing silicone rubber, based on incorporated capsules, with prolonged service life after PD detection represents an attractive material design for HV electrical insulation.
One of the biggest problems in high-voltage silicone rubber insulation cable accessories is the damage on electrical treeing, initiated by partial discharges. The electrical treeing starts at unavoidable imperfections inside the material or at interfaces. The damage is usually irreversible and leads around the starting points to a partial destruction of the material. To prolong the lifetime and thereby to increase the assurance of the structural component commonly, for mechanical improvement constituted filler is modified to obtain a self-healing silicone rubber. Damage mechanism is analysed to address the filler to the damage mode.
Im Arbeitskreis von Herrn Prof. Dr. Menzel (TU Braunschweig) wurde in Sievershausen ein Vortrag zum Thema „Self-healing and mechanically reinforced silicone rubber by the use of multifuctional capsules“ gehalten. Der Vortrag beginnt mit einer kurzen Motivation und einem Überblick über selbstheilende Materialien. Daraufhin werden die Ergebnisse zur Entwicklung eines selbstheilenden Silikonelastomers auf Basis von Kapseln, bestehend aus einem PDMS Kern und einer POS Hülle, dargestellt. Es folgt die Analytik, die auf DLS, TGA, UV/Vis und Fluoreszenzspektroskopie sowie SEM beruht. Der Vortrag endet mit einem Ausblick über zukünftige Arbeiten auf dem Gebiet.