Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (14) (entfernen)
Referierte Publikation
- nein (14)
Schlagworte
- Monitoring (5)
- Acoustic emission (4)
- SealWasteSafe (3)
- Fibre optic sensing (2)
- Schallemission (2)
- AAM (1)
- Accelerometer (1)
- Accelerometers (1)
- Acoustic Emission Monitoring (1)
- Acoustic emissions (AE) (1)
- Alkali-Activated Mortars (1)
- Bending tests on pipe segments (1)
- Beschleunigungssensoren (1)
- Bondline (1)
- Borehole probe (1)
- Continous monitoring (1)
- Crack growth (1)
- Crack initiation (1)
- Distributed acoustic sensing (1)
- Embedded sensors (1)
- Engineered barrier (1)
- Engineered barriers (1)
- Faseroptische Sensorik (1)
- Fiber optic sensing (1)
- Fibre optic acoustic sensing (1)
- Four-point bending test (1)
- Frequenzanalyse (1)
- Holz (1)
- Individual cell tracking (1)
- Insitu test (1)
- Laser-Pulver-Auftragschweißen (LPA) (1)
- Leak detection (1)
- Materials technology (1)
- Mikro CT (1)
- Optische Emissionsspektroskopie (OES) (1)
- Passive sensor interface (1)
- Pipeline monitoring (1)
- Pipelines (1)
- RFID (1)
- RFID technology (1)
- Rissbildung in Stahl (1)
- Rohrleitung (1)
- Schallemissionsanalyse (SEA) (1)
- Signal Analysis (1)
- Steel pipe (1)
- Structural Health Monitoring (1)
- Structural Integrity (1)
- Sychrotron tomography (1)
- Thermographie (1)
- Ultrasonic imaging (1)
- Ultrasound (1)
- Wood Materials (1)
- Wood materials (1)
- alkali-activated material (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (12)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (11)
- 9 Komponentensicherheit (5)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 8.6 Faseroptische Sensorik (4)
- 9.6 Additive Fertigung metallischer Komponenten (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 3.2 Gefahrguttanks und Unfallmechanik (2)
Rohrleitungssysteme sind aufgrund ihrer Funktion und Ausdehnung für den Betrieb, die Verfügbarkeit und die Sicherheit von Industrieanlagen von besonderer Bedeutung. Die bisher in definierten Intervallen durchgeführten, wiederkehrenden Prüfungen zur Sicherstellung leckagefreier Rohrleitungen sind kostenintensiv und mit einem erhöhten Aufwand verbunden.
Mit dem interdisziplinären Forschungsprojekt AGIFAMOR (Ageing Infrastructures – Akustisches Monitoring von Rohrleitungen) arbeitet die BAM an der Entwicklung und Erprobung einer örtlich und zeitlich kontinuierlichen Zustandsüberwachung von Rohrleitungen basierend auf einem faseroptischen akustischen Messsystem, welches einen vergleichsweise geringen Installationsaufwand der Sensoren erfordert. Mit diesem Verfahren sollen vor allem betriebsbedingte Schädigungen infolge von Korrosion sowie daraus entstehende Pittings oder Risse erkannt und damit Leckagen verhindert werden.
Im Rahmen einer Machbarkeitsstudie zum Teilaspekt „Detektion von Risswachstum“ wurde ein 2,5 m langes, definiert vorgekerbtes Stahlrohr mit der faseroptischen Sensorik (FOS) ausgestattet und quasistatisch unter 4-Punkt-Biegung belastet. Mit fortschreitender Belastung wächst, ausgehend vom vorhandenen Außenumfangskerb, ein Riss im Stahlrohr bis zum Erreichen der Leckage – in der Praxis ein gefährliches Schadensszenario.
Parallel zur FOS erfolgten Messungen mit Schallemissionssensoren, Beschleunigungssensoren und Potentialsonden, deren Ergebnisse die Interpretation der FOS-Messergebnisse unterstützen sollen.
Pipelines and industrial piping systems are particularly relevant regarding technical safety, availability and maintenance. Large flow rates of hazardous substances imply that even smallest leakages can lead to high environmental impacts. Therefore, and to ensure the availability of infrastructure, an early detection and localization of potentially hazardous degradations to the walls (e.g. cracks, pittings, sedimentation, etc.) of the containments is necessary. However, in many cases it is not feasible to equip pipelines with a large number of point sensors at reasonable expense.
The principle of distributed fibre optic sensing relies on one single optical fibre, which simultaneously acts as a spatially continuous sensor as well as the signal transducer. Therefore, extensive structures can be provided with this type of sensor with comparatively low efforts.
As a consequence, monitoring oil and gas pipelines using distributed fibre optic sensors is on the upswing. Besides the established methods to measure temperature and strain, distributed acoustic sensing (DAS) has lately received considerable attention as a means to detect and localize third party threats to pipelines (approach of vehicles, digging, mechanical manipulation).
The so far not utilized potential of DAS as a means for continuous condition monitoring of pipes by detecting and localizing acoustic signals that point to certain damage scenarios, is currently under investigation in an interdisciplinary research project at BAM (AGIFAMOR, Ageing Infrastructures – Fibre Optic Monitoring of Pipes).
In order to qualify distributed acoustic fibre optic sensors for this application area, we especially focus on detecting and identifying the relevant acoustic emissions of interesting degradations as well as on the optimal way of application of the optical fibres to the specimen to achieve an optimal signal transmission of acoustic signals.
The monitoring of oil and gas pipelines by means of distributed fibre optic sensors is becoming common. The most recent development in the field of fibre optic sensing is the distributed acoustic sensing (DAS), which allows to detect and to localize third party threats to pipelines. For this purpose, fibre optic telecommunication cables located close to the pipelines are usually used. However, DAS carries a far greater potential for continuous condition monitoring of pipelines.
The interdisciplinary research project AGIFAMOR (Ageing Infrastructures – Fibre Optic Monitoring of Pipes) at BAM investigates a new technical approach to extend the application field of DAS towards the detection and localization of acoustic signals that indicate critical alterations and certain damage scenarios originated from within the pipeline or the pipe wall. Therefore, the optical fibre sensors are applied onto the pipe itself and the application procedure towards an optimal acoustic signal transduction is optimized.
A number of laboratory scale experiments were performed focusing on the signal transmission of acoustic signals as well as the detection of damages in the pipe wall by means of DAS. Furthermore, real-scale tests on a pipeline DN100 of 38m length have been carried out at the BAM test site for technical safety (BAM-TTS) to study the detection and localization of leaks and of changing flow profiles due to corrosion or sedimentation processes.
Four-point bending tests were carried out to analyze the acoustic characteristics of damage development in pipe segments made of steel, grade S355J2H, being 2.5 m long with an outer diameter of 168 mm and 16 mm wall thickness. To induce stable crack growth, the pipe segments were pre-damaged by a 90°circumferential notch in the middle of the pipe length. While the pipe was quasi-statically loaded, microscopic damage and plastic deformation accumulated to form a macroscopic crack that grew through the pipe wall until leakage. For acoustic emission (AE) monitoring, four broadband sensors of type VS 900 M were mounted close to the notch. Continuous AE signal detection was performed by the non-threshold method. Advantages and disadvantages of the non-threshold AE monitoring compared to a commonly employed method analyzing only signals exceeding a predefined threshold are discussed. The results of AE analysis are compared to additional information on the crack growth detected by the direct current potential drop (DCPD) technique. These studies were carried out in the course of the interdisciplinary research project AGIFAMOR, Ageing infrastructures - distributed acoustic monitoring of pipes at BAM.
The feasibility study „AGIFAMOR. Ageing infrastructures – distributed acoustic monitoring of pipes” is an interdisciplinary research project at BAM internally financed from 2015 to 2018. Therefore, the quite young fibre optic sensing technology of distributed acoustic sensing (DAS) was investigated to possibly be extended towards a global condition monitoring system for pipelines operating in real time.
DAS is a highly dynamic fibre optic sensing technology based on the method of coherent optical time domain reflectometry (C-OTDR). DAS allows capturing strain changes in the range of kHz. For the experimental work, the most suitable application yielding an optimum sensitivity was proven by wrapping a standard single-mode silica fibre around the pipe.
The DAS sensitivity was investigated regarding the detection of 1) incidents that initiate propagation of acoustic waves in the pipe wall, 2) changes inside the pipeline causing altered flow and 3) damage development in the pipe wall. Therefore, several testing setups in laboratory as well as in real scale were realized. For comparison purposes, experiments were accompanied by acoustic emission analyses and by measurements with accelerometers.
DAS was found to be very sensitive to gas ignition and its propagation across the pipe. Furthermore, the ability of DAS to detect and localize acoustic signals associated with pipeline leakage was demonstrated. The detection of crack formation and propagation within the pipe wall by means of DAS was studied during bending tests on several pipe segments, but was not proven so far with certainty. As expected, these studies turned out as the most difficult challenge due to the random occurrence and transient nature of microscopic damage phenomena.
Against the background of sustainable resource management and efficiency, wood-based materials are currently experiencing a revival and, among others, plywood, Laminated Veneer Lumber and glued laminated timber are becoming increasingly more important in the building sector. Even though these materials are so-called engineered products, the element wood is naturally grown with intrinsic variability in mechanical properties and requires professional handling on-site. Otherwise, load-bearing structures made of wood materials may entail certain risks. Critical situations can, in principle, be avoided by implementing a structural health monitoring system into components or structures made from wood material. The aim is to indicate accumulation of mechanical damage and to eliminate or at least significantly reduce the risk of unexpected failure. Toward this purpose, the failure behavior of several layered wood materials under quasi-static tension was investigated in laboratory-scale experiments by means of acoustic emission (AE) measurement. Based on spectral analysis and pattern recognition, two classes of AE signals are identified for each investigated lay-up that are characterized by either low or high frequency contents in the respective power spectra. AE activity and intensity of both signal classes are analyzed, striving for predictors appropriate for AE monitoring concepts.
For a better understanding of the damage of glued wood tensile tests on miniature specimens made of glued spruce wood with acoustic emission and in-situ synchrotron-based X-ray computer microtomography has been monitored. As adhesive, urea-formaldehyde resin was used. For comparison purposes, tensile tests were carried out on solid wood and bonded miniature tensile shear samples with acoustic emission. The acoustic emission signals of all experiments were with classified pattern recognition. This resulted in two classes of signals for each two frequency peaks. In one class was the low-frequency, in the other the higher frequency peak of higher intensity, but this essentially independent from the structure (solid wood or plywood) and the size scale of the test specimens. The influence of the adhesive layers was determined on plywood test specimens in laboratory scale and on miniature test specimens with an adhesive layer and selected fiber orientations examined. This gave evidence that the sound emission signals from the failure of the adhesive layer presumably of the class with low frequency signals peak in the range of services can be assigned.
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.
The internal project "SealWasteSafe" of the Federal Institute for Materials Research and Testing is dedicated to the further improvement in the construction of sealing systems for underground repositories of radioactive waste. Particularly, a multi-sensory concept is developed to ensure quality assurance and continuous long-term monitoring on the engineered barriers. Therefore, beside other measures, the temperature and equilibrium moisture of the construction shall be monitored and respective multi-sensoric monitoring concepts are tested first on the laboratory scale. One focus in this project is on embedded application in alkali-activated mortars (AAM), which results in special requirements for the resistance of the sensors to strongly alkaline environments with up to pH 14. In addition, the ingress of water along cables or at sensor positions is critical for sensors embedded in concrete, as the cable access of the sensor housing is a major weak point. It is therefore advisable to equip wireless high frequent radio frequency identification-based sensors, so called HF RFID sensors (short: RFID), that do not require cable access and thus have a stable and leak-proof sensor housing for long-term monitoring. In this contribution, the results from temperature, moisture and transmitted power monitoring of a AAM and a M2 specimens by means of HF RFID sensor systems are presented.
Von den Zellulosefibrillen über die Zellwand und die Anordnung der Früh- und Spätholzzellen in einem Jahrring bis hin zum Balken von Natur aus ist Holz ein optimierter Hochleistungswerkstoff, der Handwerker, Architekten, Ingenieure und Wissenschaftler fasziniert und begeistert. Im digitalen Zeitalter werden neben Standard-Laborexperimenten zunehmend Modelle und Simulationen eingesetzt, um das Verhalten des Materials unter verschiedenen Belastungen besser zu verstehen und vorherzusagen. Dazu werden Zahlenwerte von Verformungen im subzellulären Maßstab benötigt, die nun in Experimenten an der TOMCAT-Beamline (TOmographic Microscopy and Coherent rAdiology ExperimenTs) der SLS (Swiss Light Source) gewonnen werden konnten: Holzproben aus Fichte ( Picea abies Karst.) mit einem Prüfquerschnitt von mindestens 1 mm² auf Zug oder Druck beansprucht. Die strukturellen Veränderungen auf Zellebene wurden mittels Computertomographie erfasst. Für die nachträgliche Analyse der 3D-Mikrostruktur von Holz wurde ein Ansatz entwickelt, der es ermöglicht, einzelne Zellen, die in mehreren Tomogrammen unterschiedlicher Belastungszustände erfasst wurden, zu verfolgen. Dabei wurden die Zellgeometrien und das subzelluläre Deformationsverhalten quantifiziert. Unter Zugbelastung beispielsweise verengt sich die Zellwanddicke um ca. 0,8%, das sind bei der gemessenen mittleren Zellwanddicke von 3,5 µm ca. 28 nm. Diese und andere Erkenntnisse liefern nun einen direkten numerischen Zusammenhang zwischen Verformungen der Holzmikrostruktur und dem daraus resultierenden makroskopischen Verhalten.