Filtern
Dokumenttyp
- Vortrag (14)
Referierte Publikation
- nein (14)
Schlagworte
- Acoustic emission (5)
- Monitoring (5)
- Schallemission (4)
- Rohrleitung (3)
- Acoustic Emission (2)
- Acoustic Emission (AE) (2)
- Beschleunigungssensoren (2)
- Faseroptische Sensorik (2)
- Wood materials (2)
- Accelerometer (1)
- Accelerometers (1)
- Al-Si alloys (1)
- AlSi12CuMgNi (1)
- Alkali aktiviertes Material (1)
- Bending tests on pipe segments (1)
- Continous monitoring (1)
- Crack growth (1)
- Crack initiation (1)
- Distributed acoustic sensing (DAS) (1)
- Fibre optic acoustic sensing (1)
- Fibre optic sensing (1)
- Four-point bending test (1)
- Frequenzanalyse (1)
- Geopolymer (1)
- Holz (1)
- Holzwerkstoffe (1)
- Individual cell tracking (1)
- Leak detection (1)
- Mikro CT (1)
- Monitoring Konzept (1)
- Mustererkennung (1)
- Non-threshold measurement (1)
- Pipelines (1)
- Rissbildung in Stahl (1)
- Salzbeton (1)
- Steel pipe (1)
- Structural integrity (1)
- Tension (1)
- Unsupervised pattern recognition (1)
- Verteilte akustische faseroptische Sensorik (1)
- Verteilte faseroptische Sensorik (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (10)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (10)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 9 Komponentensicherheit (4)
- 9.6 Additive Fertigung metallischer Komponenten (4)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.6 Faseroptische Sensorik (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
Eingeladener Vortrag
- nein (14) (entfernen)
Four-point bending tests were carried out to analyze the acoustic characteristics of damage development in pipe segments made of steel, grade S355J2H, being 2.5 m long with an outer diameter of 168 mm and 16 mm wall thickness. To induce stable crack growth, the pipe segments were pre-damaged by a 90°circumferential notch in the middle of the pipe length. While the pipe was quasi-statically loaded, microscopic damage and plastic deformation accumulated to form a macroscopic crack that grew through the pipe wall until leakage. For acoustic emission (AE) monitoring, four broadband sensors of type VS 900 M were mounted close to the notch. Continuous AE signal detection was performed by the non-threshold method. Advantages and disadvantages of the non-threshold AE monitoring compared to a commonly employed method analyzing only signals exceeding a predefined threshold are discussed. The results of AE analysis are compared to additional information on the crack growth detected by the direct current potential drop (DCPD) technique. These studies were carried out in the course of the interdisciplinary research project AGIFAMOR, Ageing infrastructures - distributed acoustic monitoring of pipes at BAM.
Feasibility study: Continuous monitoring of pipes using distributed acoustic and fibre optic sensors
(2018)
The feasibility study „AGIFAMOR. Ageing infrastructures – distributed acoustic monitoring of pipes” is an interdisciplinary research project at BAM internally financed from 2015 to 2018. Therefore, the quite young fibre optic sensing technology of distributed acoustic sensing (DAS) was investigated to possibly be extended towards a global condition monitoring system for pipelines operating in real time.
DAS is a highly dynamic fibre optic sensing technology based on the method of coherent optical time domain reflectometry (C-OTDR). DAS allows capturing strain changes in the range of kHz. For the experimental work, the most suitable application yielding an optimum sensitivity was proven by wrapping a standard single-mode silica fibre around the pipe.
The DAS sensitivity was investigated regarding the detection of 1) incidents that initiate propagation of acoustic waves in the pipe wall, 2) changes inside the pipeline causing altered flow and 3) damage development in the pipe wall. Therefore, several testing setups in laboratory as well as in real scale were realized. For comparison purposes, experiments were accompanied by acoustic emission analyses and by measurements with accelerometers.
DAS was found to be very sensitive to gas ignition and its propagation across the pipe. Furthermore, the ability of DAS to detect and localize acoustic signals associated with pipeline leakage was demonstrated. The detection of crack formation and propagation within the pipe wall by means of DAS was studied during bending tests on several pipe segments, but was not proven so far with certainty. As expected, these studies turned out as the most difficult challenge due to the random occurrence and transient nature of microscopic damage phenomena.
Acoustic Emission
(2018)
Das Phänomen Schallemission (eng. Acoustic Emission, AE) ist eine Begleiterscheinung bei aktiven Mechanismen und Prozessen wie sie in Werkstoffen auftreten, die einer Belastung durch Krafteinwirkung oder durch Änderung der Umgebungsbedingungen ausgesetzt sind. Plastische Verformung, Risswachstum, Korrosion oder der Übergang zu einer anderen Phase generieren u.a. transiente elastische Wellen, die sich im Werkstoff und an der Materialoberfläche ausbreiten. Auftretende Auslenkungen von wenigen hundert Pikometern sind mit piezo-elektrischen AE Sensoren detektierbar. Aufzeichnungsraten von bis zu 40 MHz ermöglichen dabei zeitliche Auflösungen von einigen Nano- bis Mikrosekunden. Die Dechiffrierung der detektierten Informationen ist für die Material- und Versagenscharakterisierung sowie für Anwendungen in der Struktur- oder Prozessüberwachung ein zentraler Forschungsschwerpunkt.
Nach einem kurzen Überblick zu den Grundlagen werden ausgewählte Ansätze der AE Methode vorgestellt und diskutiert:
1) AE Monitoring von Pipelines als Referenzmessung für die Entwicklung eines akustischen faseroptischen Monitorings (AGIFAMOR)
2) Schwellwertfreie AE Messung im 4-Punkt-Rohrbiegeprüfstand BAM_9.1 (AGIFAMOR)
3) Kombination von AE mit Röntgen-Mikrotomografie und die Anwendung der frequenzbasierten Mustererkennung ermöglichen eine Zuordnung von AE und Mechanismen (Ergebnisse aus dem SNSF Projekt Nr. 127'134, Baensch 2014, Diss. ETH No. 22372)
Um ein tieferes Verständnis über die Schallemission bei der Entstehung und Ausbreitung von Rissen in Stahlrohrleitungen zu erlangen, wurde ein Stahlrohr der Güte S355J2H im Vierpunkt-Biegeversuch quasistatisch bis hin zum Wanddurchbruch (Leckage) belastet und mittels Schallemissionsmessung und Gleichstrompotentialmessung überwacht. Das Rohrsegment wurde durch einen 90°- Außenumfangskerb in der Mitte der Rohrlänge definiert vorgeschädigt, um davon ausgehend ein stabiles Risswachstum zu induzieren und die Analyse von Schallemission aus Rissereignissen, die am Kerb eintraten, sicherzustellen. Für die Schallemissionsmessung wurden vier Breitbandsensoren max. 105 mm vom Kerb entfernt montiert. Die Signalaufzeichnung erfolgte kontinuierlich und schwellwertunabhängig. Für die Gleichstrompotentialmessung wurde ein Gleichstrom von 300 A eingeleitet und der Potentialabfall über dem Kerb mit fünf Sonden entlang des Kerbs gemessen. Beide Messverfahren identifizieren die Rissinitiierung sowie Veränderungen im Risswachstum. Die detektierten Schallemissionsereignisse werden, unter Berücksichtigung spektraler Eigenschaften, mit fortschreitender Belastung und Rissentwicklung analysiert. Diese Studien wurden im Rahmen des interdisziplinären Forschungsprojekts AGIFAMOR, Aging infrastructure - Faseroptisches Monitoring von Rohrleitungen, an der BAM durchgeführt.