Eingeladener Vortrag
- nein (42)
Due to the corrosion resistance of carbon steel, bridge constructions are currently protected against corrosion by applied coating systems. These coating systems need to be renewed after approximately 25 50 years. Galvanized constructions without any welding areas at the construction site could be prepared as grouted joints and can be used without any renewing for about 100 years.
Exposure sites and outdoor exposure have always been a part of atmospheric corrosion research providing the “final answer”, although at the cost of long exposure times. Individual exposure programs such as ISOCORRAG, MICAT and ICP Materials have resulted in collaborative networks of exposure sites. So far, however, there has been no collective effort to put together currently active sites in a comprehensive manner and across programs and nations. The information collected in the catalogue is possible thanks to the work of all individual site managers listed as contact persons, efforts of members of Working Party 25 (WP25) Atmospheric Corrosion of the European Federation of Corrosion (EFC) and financial support of the EFC. With this Catalogue you can both get a general overview of what is available and be guided if you are looking for a particular environment with certain characteristics.
Das Grundproblem der heute verfügbaren und normativ geregelten Prüfverfahren für Zinküberzüge besteht neben den realitätsfernen Prüfbedingungen vor allem in der subjektiv geprägten Auswertung der Prüfergebnisse. Die systematische Betrachtung der Entwicklungen der letzten Jahre zeigt, dass die üblichen Verfahren den aktuellen Anforderungen damit schon vom Ansatz her nicht gerecht werden können und auch die bisher betriebene, fortlaufende Variation und Anpassung von Prüfbedingungen keinen grundlegend neuen Lösungsansatz bieten können. Ein solcher ergibt sich nur, wenn die Zinküberzüge hinsichtlich der kinetischen Eigenschaften der Deckschichtbildung und -auflösung umfassend beschrieben werden können, was nur durch den Einsatz elektrochemischer Untersuchungsmethoden mittels Gelelektrolyten möglich ist.
Aus diesem Grund wurde im Verbundforschungsvorhaben GELELEK auf der Basis elektrochemischer Methoden unter Verwendung eines Gelelektrolyten ein Normenvorschlag für eine Prüfnorm erarbeitet und zur Normungsreife geführt, welcher den Anforderungen an ein Messsystem für Feldanwendungen entspricht.
Im Verbundforschungsvorhaben GELELEK wurde eine gezielte Kombination von Laboruntersuchungen mit Untersuchungen im Feld und Bauteilen unter realen Einsatzbedingungen angestrebt. Randbedingungen für eine gesicherte Messung von atmosphärisch bewitterten Zinküberzügen unter Einsatz von Gelelektrolyten wurden erarbeitet und im Normenvorschlag festgeschrieben. Darüber hinaus wurde ein mobiles Messgerät für Messungen mit Gelelektrolyten an realen Bauteilen entwickelt. Nach Abschluss des Forschungsvorhabens steht Industrievertretern und Prüfinstituten ein wissenschaftlich gesichertes Messverfahren basierend auf Kennwerten zur Verfügung, um Zinküberzüge und deren momentane Schutzwirkung unter praxisrelevanten Bedingungen einschätzen und normativ geregelt prüfen zu können.
Der vorliegende Forschungsbericht gibt einen Überblick über die Motivation zur Durchführung des Forschungsvorhabens, wichtige Arbeitsschritte, Details zur entwickelten Prüfmethode sowie Einsatzmöglichkeiten für Prüfinstitute und Unternehmen.
The presentation shows systematic investigations to describe the corrosion and corrosion product formation processes of pure zinc under the climatic conditions currently prevailing in the Federal Republic of Germany. The investigations in their entirety aim at questioning current and establishing new ways of looking at the formation of corrosion products of pure zinc under atmospheric corrosion conditions. Thus, they make a significant contribution in understanding corrosion protection by zinc and zinc coatings. In particular, the focus is placed on the initial stage of the corrosion product formation. A systematic investigation of this time range, which is characterized by very reactive corrosion products, is only made possible by using gel-type electrolytes. The short periods of time at the beginning of weathering is now measurable and their influence on the formation of corrosion products and the kinetics of layer formation describable. By combining the new electrochemical approach with gravimetric, microscopic and analytical methods, new insights could be gained both on a methodic and scientific level.
The corrosivity of atmospheres in Europe has changed significantly in recent decades. For the Federal Republic of Germany, no current values for the corrosion rate based on 1‐year atmospheric exposure of standard specimens can be found in the scientific literature after 2000. This paper presents results from a field exposure study in the Berlin metropolitan area and Helgoland in 2016. Based on standard specimens, values for the corrosion rate and the corresponding atmospheric corrosivity category are determined for open exposure and indirect weathering in a ventilated enclosure as sheltering after 1 year of exposure. The results prove that determined corrosivity categories are material‐specific. Sheltered exposure is a typical atmospheric situation for many building components. It allows statements on the effect of the concentration of airborne substances on the corrosivity beyond the normative requirements.
Bei Betrachtungen zur Lebensdauer von Metallbauteilen im Bauwesen müssen Korrosions- und Runoff-Vorgänge an der Atmosphäre als verschiedene Reaktionen unterschieden werden. Korrosion ist der Prozess, der von elektrochemischen Reaktionen an der Grenzfläche Metall/Patina kontrolliert wird. Runoff dagegen wird durch chemische Reaktionen an der Grenzfläche Patina/Atmosphäre begünstigt. Mit zunehmender Bewitterungszeit nimmt die Korrosionsgeschwindigkeit stetig ab, während postuliert wird, dass die Geschwindigkeit des Runoffs über die gesamte Zeit konstant bleibt. Dieses Verhalten des Runoffs muss aber zunehmend bezweifelt werden. Die Gesamtmenge an abgezehrtem Metall beinhaltet zwei Bestandteile. Ein Teil wird in die Schicht aus Korrosionsprodukten eingebaut, der andere wird aufgrund von Niederschlägen aus der Patina gelöst. Aus diesem Grund ist die Menge an Zink-Runoff stark abhängig von den Eigenschaften der Korrosionsprodukt- bzw. Patinaschicht und nicht anhand der Zusammensetzung des Metalls abschätzbar. Vorhandene Modelle können die Menge an Runoff, und damit verbunden die Abzehrung einer Schicht aus Zink und Kupfer, sowie den resultierenden Eintrag von Schwermetallionen in die Umwelt nicht mehr darstellen und erklären. Um den Korrosionsschutz an Bauwerken zum einen dauerhaft unter Beachtung von Kostenaspekten und Ressourcenschonung und zum anderen unter ökologischen Gesichtspunkten auslegen zu können, müssen deshalb neue wissenschaftliche Grundlagen erarbeitet und die Mechanismen beschrieben werden.
Das BAM-Forschungsvorhaben RUNOFF widmet sich den Fragestellungen. Der Vortrag gibt einen kurzen Überblick zum Forschungsvorhaben.
Durch Fortführung der Untersuchungen aus einem Forschungsvorhaben wurden neun verschiedene Stahllegierungen unter maritimen Umgebungsbedingungen über zehn Jahre ausgelagert und deren Korrosionsverhalten untereinander verglichen und bewertet. Anhand der Ergebnisse der Auslagerungsprüfungen konnten Rückschlüsse auf die Einflüsse der Legierungszusammensetzung, der Oberfächenausführung und der Auslagerungszeit unter maritimen Auslagerungsbedingungen gewonnen werden. Die Proben der drei untersuchten Duplexwerkstoffe zeigten über den Auslagerungszeitraum von zehn Jahren sowohl mit als auch ohne Spaltgeometrie die beste Korrosionsbeständigkeit. Ebenso konnte der molybdänlegierte Ferrit 1.4521 eine vergleichbar gute Korrosonsbeständigkeit erzielen, wie die klassischen austenitischen Werkstoffe 1.4301 und 1.4404.
Novel agar-based test electrolytes are used to perform electrochemical corrosion investigations on ZnFe and ZnNi binary as well as ZnFeMo ternary zinc coatings. The objectives of the electrochemical investigations include the characterization of the corrosion behavior, the description of the protective effect of the coatings as well as the investigation of the layer formation and degradation under artificial aging. ZnFe and ZnFeMo coatings are applied with varying iron content as well as an additional passivation layer, respectively, to study the effect on corrosion resistance. The results show that the protective effect of the coatings is not negatively influenced by different iron contents or the addition of molybdenum. Additional passivation of the ZnFe-containing coatings by means of a passivating agent leads to a significant improvement in the protective effect. Artificial aging leads to slight degradation of the additional passivation layer whereas coatings without post-treatment enhance their protective effect by the formation of corrosion product layers.