Filtern
Dokumenttyp
- Beitrag zu einem Sammelband (13)
- Beitrag zu einem Tagungsband (7)
- Vortrag (7)
- Zeitschriftenartikel (6)
- Posterpräsentation (2)
- Dissertation (1)
Schlagworte
- Concrete (7)
- Zerstörungsfreie Prüfung im Bauwesen (7)
- Beton (6)
- Puls-Phasen-Thermografie (5)
- Radar (5)
- Voids (5)
- Active thermography (4)
- Aktive Thermografie (4)
- Pulse phase thermography (4)
- Impulse-thermography (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
Abstract
In the recent years the application of infrared thermography and especially its active approaches lock-in thermography, impulse themography and pulse phase thermography (PPT) has gained more importance for non-destructive testing (NDT). In this paper it is demonstrated that PPT is very well suited for NDT in civil engineering. The method is based on pulse heating of the investigated specimen and on the observation of the cooling down process on its surface with an infrared camera. The transient behaviour is afterwards analysed with Fast Fourier Transformation, enabling the creation of phase and amplitude images with enhanced visualisation of the defects. Results of European and National (i.e. DFG) funded projects are presented, for example the detection of voids and inhomogeneities close to the surface and the localisation of delaminations on plastered concrete and masonry specimen.
ZUSAMMENFASSUNG
Im Rahmen eines von der Deutschen Forschungsgemeinschaft geförderten Vorhabens zur zerstörungsfreien Prüfung im Bauwesen wird in der Bundesanstalt für Materialforschung und -prüfung (BAM) in Zusammenarbeit mit der Technischen Universität Berlin (TUB) die Puls-Phasen-Thermografie (PPT) weiterentwickelt, bewertet und eingesetzt. Die durch die Impuls-Thermografie (IT) aufgenommenen Daten werden mittels Fast Fourier Transformation (FFT) bearbeitet. Die durch die FFT gewonnenen Phasenbilder reduzieren die Störeinflüsse von Oberflächeninhomogenitäten und ungleichmäßiger Erwärmung.
Die dargestellten Ergebnisse zeigen deutlich, dass sich die PPT sehr gut zur zerstörungsfreien Prüfung im Bauwesen eignet. Insbesondere Inhomogenitäten im oberflächennahen Bereich, wie Ablösungen und Hohlstellen hinter Beschichtungen (Putz, CFK-Laminate etc.), aber auch Defekte in größeren Tiefen können zuverlässig geortet und bildgebend dargestellt werden.
Struktur- und Feuchteuntersuchungen von Bauteil- und Bauwerksoberflächen mit der Impuls-Thermografie
(2005)
An advanced quantitative approach of pulse-phase-thermography for nondestructive
testing in civil engineering is described in this contribution. The
characteristic frequency of the maximum phase-contrast between defects and sound
areas is used as a means for the characterization of its depth.
The new approach is tested in the laboratory on concrete structures with defects of
polystyrene. The surfaces of the structures were heated with IR-radiators for varying
time periods.
The presented investigations were funded by the Deutsche Forschungsgemeinschaft
(DFG) and were carried out in co-operation with the Technical University of Berlin
(TUB).
The active approach for non-destructive-testing in Civil Engineering (NDT-CE) with infraredthermography (IR), developed at the Federal Institute for Materials Research and Testing (BAM), is described in part one of this contribution. The active IR-approach is based on the principles of impulse- (IT) and pulse-phase-thermography (PPT). The concept is a direct result of a research project at the BAM in cooperation with the Technical University of Berlin (TUB) and was funded by the Deutsche Forschungsgemeinschaft (DFG). In the second part results of the new thermography-scanning system (thermo-scanner) of BAM on debonding of multi-layered structures, especially carbon fibre reinforced plates (CFRP) on concrete are presented. Both, the thermo-scanner developed at BAM, and the investigations carried out, are part of the
EU-Project Sustainable Bridges. In the third part of the paper the characteristic frequency of the optimum phase-contrast as a means for the characterization of defects depth in CE by means of PPT is introduced. A new quantitative approach is tested and discussed on concrete structures with defects of polystyrene and gas concrete.