Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (35)
- Zeitschriftenartikel (32)
- Posterpräsentation (3)
- Beitrag zu einem Tagungsband (2)
- Dissertation (1)
- Sonstiges (1)
- Forschungsbericht (1)
Schlagworte
- TED-GC/MS (24)
- Microplastics (21)
- Mikroplastik (20)
- Microplastic (15)
- Reference materials (6)
- Mikroplastik-Analytik (5)
- Polymer 3R (5)
- CUSP (4)
- Referenzmaterial (4)
- TED-GC-MS (4)
Organisationseinheit der BAM
- 6 Materialchemie (66)
- 6.6 Physik und chemische Analytik der Polymere (66)
- 6.1 Oberflächen- und Dünnschichtanalyse (7)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
- 5 Werkstofftechnik (2)
- 6.3 Strukturanalytik (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.3 Polymere Verbundwerkstoffe (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (35)
Funktionalisierte Oberflächen sind in vielen Bereichen, z. B. als Haftvermittler in Polymerkompositen, für katalytische Anwendungen oder als Sensoren von Interesse. Für viele solcher Anwendungen ist es ausreichend, den verwendeten Werkstoff mit einem ultradünnen Polymerfilm zu überziehen. Dazu gibt es bislang einige Verfahren, wie z. B. Chemical Vapour Deposition, Layer-by-Layer-Technik, Langmuir-Blodgett-Technik oder Spin-Coating, die alle bestimmte Nachteile haben.
In der vorliegenden Arbeit wurden wenige Nanometer dicke Polymerschichten auf metallischen und nicht-metallischen Substraten mittels Elektrospray Ionisation abgeschieden.
So wurden typischerweise etwa 10 nm dicke Schichten von Polyacrylsäure (PAA) hergestellt. Die analytische Charakterisierung der produzierten Schichten erfolgte mit der Röntgen-Photoelektronenspektroskopie. Die Atomkraft- bzw. Rasterelektronenmikroskopie gaben Auskunft über den Bedeckungsgrad und die Schichtmorphologie. Die Infrarot-Reflexions-Absorptions-Spektroskopie wurde zur Bestimmung des Restlösemittelgehaltes verwendet.
Zur Optimierung der Schichtabscheidung und -struktur wurden verschiedene Parameter variiert, wie z. B. der Kapillaren-Proben-Abstand, die Beschichtungszeit oder die Beschichtungstemperatur, wobei sich herausstellte, dass die Schichtbildungsparameter für jedes Polymer individuell angepasst werden müssen.
Es konnte gezeigt werden, dass Beschichtungen, bei denen sich das Substrat senkrecht zur Kapillare befindet, bei Raumtemperatur mit einem Kapillaren-Proben-Abstand von mindestens 100 mm zu lösemittelfreien PAA-Schichten führen. Dabei war die Ausbildung der Filmtopographie unabhängig sowohl von der Konzentration der Lösung als auch von der Oberflächenenergie des Substrates.
Water treatment with activated carbon (AC) is an established method for the removal of organic micropollutants and natu ral organic matter. However, it is not yet possible to predict the removal of individual pollutants. An appropriate material characterization, matching adsorption processes in water, might be the missing piece in the puzzle. To this end, this study examined 25 diferent commercially available ACs to evaluate their material properties. Frequently reported analyses, including N2 adsorption/desorption, CHNS(O), point of zero charge (PZC) analysis, and X-ray photoelectron spectroscopy, were conducted on a selected subset of powdered ACs. Inorganic elements examined using X-ray fuorescence and X-ray difraction spectroscopy revealed that relative elemental contents were distinctive to the individual AC’s raw material and activation procedure. This study also is the frst to use thermogravimetric analysis (TGA) coupled to Fourier-transform infrared spectroscopy (FTIR) to conduct quantitative analyses of functional surface oxygen groups (SOGs: carboxylic acid, anhydride, lactone, phenol, carbonyl, and pyrone groups) on such a large number of ACs. The comparably economical TGA method was found to provide good surrogates for the PZC by pyrolytic mass loss up to 600 ◦C (ML600), for the oxygen content by ML1000 and for the carbon content by oxidation. Mass loss profles depict the AC’s chemistry like fngerprints. Furthermore, we found that SOG contents determined by TGA-FTIR covered a wide individual range and depended on the raw material and production process of the AC. TGA and TGA-FTIR might therefore be used to identify the suitability of a particular AC for a variety of target substances in diferent target waters. This can help practitioners to control AC use in waterworks or wastewater treatment plants.
Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted.
AbstractMicroplastics (MP) can be detected in all environmental systems. Marine and terrestrial aquatic systems, especially the transported suspended solids, have often been the focus of scientific investigations in the past. Sediments of aquatic river systems, on the other hand, were often ignored due to the time‐consuming sample preparation and analysis procedures. Spectroscopic measurement methods counting particle numbers are hardly suitable as detection methods, because there are plenty of natural particles next to a small number of MP particles. Integral methods, such as thermoanalytical methods are determining the particle mass independently of the inorganic components.In this study, a workflow for sample preparation via density separation and subsequent analysis by thermal extraction desorption‐gas chromatography/mass spectrometry is presented, which leads to representative and homogeneous samples and allows fast and robust MP mass content measurements suitable for routine analysis. Polymers were identified and quantified in all samples. Polyethylene and styrene‐butadiene rubber are the dominant polymers, besides polypropylene and polystyrene. Overall, total polymer masses between 1.18 and 337.0 µg/g could be determined. Highest MP concentrations in riverbed sediment are found in sites characterized by low flow velocities in harbors and reservoirs, while MP concentrations in sandy/gravelly bed sediments with higher flow velocities are small.
An investigation of microplastic (MP) occurrence in a municipal wastewater treatment plant (WWTP) effluent with tertiary treatment was carried out. Representative sample volumes of 1 m3 were taken by applying a fractionated filtration method (500, 100, and 50 µm mesh sizes). The detection of MP mass fractions by thermal extraction desorption–gas chromatography/mass spectrometry (TED-GC/MS) was achieved without the previously required additional sample pretreatment for the first time. Different types of quantification methods for the evaluation of TED-GC/MS data were tested, and their accuracy and feasibility have been proven for real samples. Polyethylene, polystyrene, and polypropylene were identified in effluent samples. The polymer mass content varied significantly between 5 and 50 mg m−3. A correlation between the MP load and the quantity of suspended matter in the WWTP effluents, particle size distribution, particle type, and operation day (i.e., weekday, season, and capacity) was not found. It can be concluded that a meaningful assessment of WWTPs requires a comprehensive sampling campaign with varying operation conditions.
Long-time behavior of surface properties of microstructures fabricated by multiphoton lithography
(2021)
The multiphoton lithography (MPL) technique represents the future of 3D microprinting, enabling the production of complex microscale objects with high precision. Although the MPL fabrication parameters are widely evaluated and discussed, not much attention has been given to the microscopic properties of 3D objects with respect to their surface properties and time-dependent stability. These properties are of crucial importance when it comes to the safe and durable use of these structures in biomedical applications. In this work, we investigate the surface properties of the MPL-produced SZ2080 polymeric microstructures with regard to the physical aging processes during the post-production stage. The influence of aging on the polymeric microstructures was investigated by means of Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). As a result, a time-dependent change in Young’s Modulus, plastic deformation, and adhesion and their correlation to the development in chemical composition of the surface of MPL-microstructures are evaluated. The results presented here are valuable for the application of MPL-fabricated 3D objects in general, but especially in medical technology as they give detailed information of the physical and chemical time-dependent dynamic behavior of MPL-printed surfaces and thus their suitability and performance in biological systems.
Tracking waterborne microplastic (MP) in urban areas is a challenging task because of the various sources and transport pathways involved. Since MP occurs in low concentrations in most wastewater and stormwater streams, large sample volumes need to be captured, prepared, and carefully analyzed. The recent research in urban areas focused mainly on MP emissions at wastewater treatment plants (WWTPs), as obvious entry points into receiving waters. However, important transport pathways under wet-weather conditions are yet not been investigated thoroughly. In addition, the lack of comprehensive and comparable sampling strategies complicated the attempts for a deeper understanding of occurrence and sources. The goal of this paper is to (i) introduce and describe sampling strategies for MP at different locations in a municipal catchment area under dry and wet-weather conditions, (ii) quantify MP emissions from the entire catchment and two other smaller ones within the bigger catchment, and (iii) compare the emissions under dry and wet-weather conditions. WWTP has a high removal rate of MP (>96%), with an estimated emission rate of 189 kg/a or 0.94 g/[population equivalents (PEQ · a)], and polyethylene (PE) as the most abundant MP. The specific dry-weather emissions at a subcatchment were ≈30 g/(PEQ · a) higher than in the influent of WWTP with 23 g/(PEQ · a). Specific wet-weather emissions from large sub-catchment with higher traffic and population densities were 1952 g/(ha · a) higher than the emissions from smaller catchment (796 g/[ha · a]) with less population and traffic. The results suggest that wet-weather transport pathways are likely responsible for 2–4 times more MP emissions into receiving waters compared to dry-weather ones due to tire abrasion entered from streets through gullies. However, more investigations of wet-weather MP need to be carried out considering additional catchment attributes and storm event characteristics.
Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed.
TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance.
The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation.
Microplastic (MP) contamination in natural water circulation is a concern for environmental issues and human health. Various types of polymer materials have been identified and were detected in MP analytic test procedures. Beyond MP polymer type, particle size and form play a major role in water analysis due to possible negative toxicologic effects on flora and fauna. However, the correct quantitative measurement of MP size distribution over several orders of magnitude is strongly influenced by sample preparation, filtration materials and processes, and microanalytical techniques, as well as data acquisition and analysis. In this paper, a reference methodology is presented aiming at an improved quantitative analysis of MP particles. An MP analysis workflow is demonstrated including all steps from reference materials to sample preparation, filtration handling, and MP particle size distribution analysis. Background-corrected particle size distributions (1–1000 µm) have been determined for defined polyethylene (PE) and polyethylene terephthalate (PET) reference samples. Microscopically measured particle numbers and errors have been cross-checked with the total initial mass. In particular, defined reference MP samples (PE, PET) are initially characterized and applied to filtration experiments. Optical microscopy imaging on full-area Si filters with subsequent image analysis algorithms is used for statistical particle size distribution analysis. To quantify the effects of handling and filtration, several blind tests with distilled water are carried out to determine the particle background for data evaluation. Particle size distributions of PE and PET reference samples are qualitatively and quantitatively reproduced with respect to symmetry, and maximum and cut-off diameter of the distribution. It is shown that especially MP particles with a radius of >50 µm can be detected and retrieved with high reliability. For particle sizes <50 µm, a significant interference with background contamination is observed. Data from blank samples allows a correction of background contaminations. Furthermore, for enhanced sampling statistics, the recovery of the initial amount of MP will be qualitatively shown. The results are intended as an initial benchmark for MP analytics quality. This quality is based on statistical MP particle distributions and covers the complete analytic workflow starting from sample preparation to filtration and detection. Microscopic particle analysis provides an important supplement for the evaluation of established spectroscopic methods such as Fourier-transform infrared spectroscopy or Raman spectroscopy.
Stainless steel AISI 304 surfaces were studied after a mild anodic polarization for oxide growth in the presence and absence of two derivatives of vitamin B2 (riboflavin and flavin mononucleotide) that can be secreted by metal‐reducing bacteria and act as a chelating agent for iron species. The alterations in oxide chemistry were studied by means of surface‐sensitive techniques such as X‐ray photoelectron spectroscopy and time‐of‐flight secondary ion mass spectrometry analysis. The complementary electrochemical characterization revealed a preferential growth of an oxide/hydroxide iron‐rich film that is responsible for an altered pit initiation and nucleation behavior. These findings suggest that as the corrosion behavior is determined by the interplay of the chemical and electronic properties, only a mild anodic polarization in the presence of redox‐active molecules is able to alter the chemical and electronic structure of the passive film formed on stainless steel AISI 304. This helps to achieve a profound understanding of the mechanisms of microbially influenced corrosion (MIC) and especially the possible effects of the redox‐active biomolecules, as they may play an important role in the corrosion susceptibility of stainless steel surfaces.
There is growing interest in quantifying microplastics in environmental samples. This application note presents a thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) method that is well suited to automation and increased sample throughput. The method is also able to detect all particle sizes in the sample as long as the limit of detection (LOD) is reached and allows analysis of larger samples of 15 to 25 mg or more. Samples were decomposed by thermogravimetric analysis (TGA), and the gaseous decomposition products were trapped on a solid-phase sorbent, followed by thermal desorption‑gas chromatography/mass spectrometry (TD-GC/MS) using an Agilent 5977B GC/MSD coupled to an Agilent 7890B GC. Target microplastic particle (MP) polymers were identified in environmental samples including surface water, finished compost, house dust, and drinking water. Quantification of MP polymers in environmental samples provided LODs of 0.06 to 2.2 μg, allowing the detection of MPs in trace amounts with sample weights of up to 1 g. Method repeatability was adequate for reliable quantification with RSDs of approximately 6 to 12%.
A new concept for the ecotoxicological assessment of plastics under consideration of aging processes
(2023)
Microplastics are widely distributed in aquatic and terrestrial environments, but up to now less is known about (eco)toxicological impacts under realistic conditions. Research so far has focused mainly on impacts on organisms by fresh, single‐origin plastic fragments or beads. However, plastics found in the environment are complex in composition, this means different polymer types and sources, with and without additives and in all stages of age, and therefore, in a more or less advanced stage of degradation. For oxidized degradation products that might be released from plastic materials during aging, there is a lack of information on potentially adverse effects on aquatic biota. The latter is of particular interest as oxidized degradation products might become more water soluble due to higher polarity and are more bioavailable, therefore. The present study focused on plastic leachates of polystyrene (PS) and polylactic acid (PLA), which were derived from alternating stress by hydrolysis and ultraviolet (UV) radiation—representing a realistic scenario in the environment. Test specimens of PS, PLA, or a PLA/PS layer (each 50%) were alternately exposed to UV radiation for 5 days followed by hydrolysis for 2 days, for several weeks alternating. Ecotoxicological effects of the storage water (artificial freshwater) of the test specimens and additionally, in a second experimental setup, the effects of five potential polymer degradation products were detected by 72 h algae growth inhibition tests with Desmodesmus subspicatus. Results clearly indicate inhibitory effects on algae growth by contaminants in the storage water of stressed plastics with increasing growth inhibition of proceeding hydrolysis and UV stress times. Different polymers caused variable inhibitions of algae growth with stronger inhibitions by PS and less effects by PLA and the mixed layer of both. Moreover, not microplastic particles but the resulting dissolved degradation products after aging caused the ecotoxicological effects—with strong effects by the oxidized degradation products. The existing data highlight the relevance of plastic aging as a framework for microplastic ecotoxicity evaluation and allow a proof of concept.
Zielsetzung des vom Bundesministerium für Bildung und Forschung geförderten Projektes RUSEKU war es, repräsentative Untersuchungsstrategien für die Detektion von Mikroplastik mittels TED GC/MS in wässerigen Medien zu ermitteln. Dabei wurden verschiedene Probenahmekonzepte und – verfahren für unterschiedliche Fallgestaltungen und Fragestellungen untersucht, sowie neue Filtersysteme entwickelt. Bei der Detektion der Partikel lag der Fokus auf der Anwendung und Weiterentwicklung der ThermoExtraktion/Desorption-Gaschromatographie-Massenspektrometrie (TED-GC/MS) zur Bestimmung von Mikroplastikgehalten. Anwendung fanden die Methoden bei der Beprobung von Flaschenwasser, Waschmaschinenabläufen, dem urbanen Abwassersystem der Stadt Kaiserslautern, sowie in Oberflächengewässer.
Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein.
Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert.
• Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen.
• Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust.
• Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt
• Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm.
• Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden.
• Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren.
Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden.
Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser.
• In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden.
• Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht.
• Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung.
• In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert.
• Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden.
Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt.
Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt.
There is only sparse empirical data on the settling velocity of small, non-buoyant microplastics thus far, although it is an important parameter governing their vertical transport within aquatic environments. This study reports the settling velocities of 4031 exemplary microplastic particles. Focusing on the environmentally most prevalent particle shapes, irregular microplastic fragments of four different polymer types (9–289 µm) as well as five discrete length fractions (50–600 µm) of common nylon and polyester fibers were investigated, respectively. All settling experiments were carried out in quiescent water using a specialized optical imaging setup. The method has been previously validated in order to minimize disruptive factors, e.g. thermal convection or particle interactions, and thus enable the precise measurements of the velocities of individual microplastic particles (0.003–9.094 mm/s). Based on the obtained data, ten existing models for predicting a particle’s terminal settling velocity were assessed. It is concluded that models, which were specifically deduced from empirical data on larger microplastics, fail to provide accurate predictions for small microplastics. Instead, a different approach is highlighted as a viable option for computing settling velocities across the microplastics continuum in terms of size, density and shape.
Despite the increasing concern about the harmful effects of micro- and
nanoplastics (MNPs), there are no harmonized guidelines or protocols yet available for MNP ecotoxicity testing. Current ecotoxicity studies often use commercial spherical particles as models for MNPs, but in nature, MNPs occur in variable shapes, sizes and chemical compositions. Moreover, protocols developed for chemicals that dissolve or form stable dispersions are currently used for assessing the ecotoxicity of MNPs. Plastic particles, however, do not dissolve and also show dynamic behavior in the exposure medium, depending on, for example, MNP physicochemical properties and the medium’s conditions such as pH and ionic strength. Here we describe an exposure protocol that considers the particle-specific properties of MNPs and their dynamic behavior in exposure systems. Procedure 1 describes the top-down production of more realistic MNPs as representative of MNPs in nature and particle characterization (e.g., using thermal extraction desorption-gas chromatography/mass spectrometry). Then, we describe exposure system development for short- and long-term toxicity tests for soil (Procedure 2) and aquatic (Procedure 3) organisms. Procedures 2 and 3 explain how to modify existing ecotoxicity guidelines for chemicals to target testing MNPs in selected exposure systems. We show some examples that were used to develop the protocol to test, for example, MNP toxicity in marine rotifers, freshwater mussels, daphnids and earthworms. The present protocol takes between 24 h and 2 months, depending on the test of interest and can be applied by students, academics, environmental risk assessors and industries.
The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods.
Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS).
Zur Ermittlung von Mikroplastik-Gehalten in verschiedenen Umweltmatrices ist ein schnelles Detektionsverfahren für die Routineanalytik notwendig. Ein solches Verfahren wird hier in Form der ThermoExtraktion/Desorption-GasChromatographie/ MassenSpektroskopie (TED-GC/MS) vorgestellt. Neben grundlegenden verfahrensspezifischen Erläuterungen zur Identifizierung und Quantifizierung von Mikroplastik werden auch exemplarische Beispiele aus unterschiedlichen Umweltkompartimenten und Produkten dargestellt. Neu vorgestellt wird ein neues Verfahren zur Analytik von Flaschenwasser. Dazu wurde ein Messfiltertiegel entwickelt, der besonders für Proben mit geringen Gehalten an abfiltrierbaren Stoffen geeignet ist