Filtern
Erscheinungsjahr
- 2011 (194) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (194) (entfernen)
Sprache
- Englisch (194) (entfernen)
Schlagworte
- CCS (7)
- Corrosion (7)
- Steel (7)
- Concrete (6)
- Strain sensor (6)
- Computed tomography (5)
- Structural health monitoring (5)
- CO2-storage (4)
- Emission (4)
- Fibre optic sensors (4)
The inelastic torsional response of an asymmetric-plan hospital building is studied. The response of the structure in the time domain as recorded by highly sensitive sensor network, integrated by a data acquisition system. The identification was performed using techniques of modal extraction in the frequency domain (frequency Domain decomposition). A calibration process was applied in order to identify a reliable structural model to be used for the seismic vulnerability assessment of the hospital building. In particular, a nonlinear static procedure accounting for mass distribution, higher modes contribution and mode-shapes correlation was proposed for the estimation of the seismic response of irregular buildings. Finally, the influence of lateral force distribution, node control during pushover and accidental eccentricity is investigated.
The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry Towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments in the Campania region were monitored by means of full-scale environmental vibration testing. Measured responses were then used for modal identification. The procedure is based on a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out by minimizing a weighted error criterion relative to the building’s modal properties. A satisfactory improvement on modal parameters is thus obtained, resulting in a close Agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is carried out with nonlinear static analysis of the tower under multimodal distributions of lateral loads.
Nonlinear analysis indicates the potential collapse mechanisms and evidences dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
Whenever the preservation of original substance obtains priority in a restoration task, reprofiling techniques using repair mortars are a welcome solution. For ordinary concrete repair aesthetic aspects are of minor importance whereas for the restoration of natural stone elements they come to the fore. Especially for listed buildings and monuments, historico-cultural and aesthetical interests become the ruling Parameters for planning and execution of restoration tasks. Nevertheless the technical and constructive requirements have to be considered and deterioration processes have to be understood to ensure sustainability and durability of the repair task. Due o differences in the Chemical and mineralogical composition, natural stone provides a vast variety of texture and colour. Also the range of different mechanical and durability related properties is far wider than found with concrete for example. A research project dealing with the development of a modular repair mortar System for natural stone is currently set up at the BAM. To provide the conservator with the best possible options to match colour, texture and technical requirements, the System will be setup on a modular basis. Several different binder Systems on basis of cement, lime and sodium Silicate as well as polymer based Systems are planned, which can be combined with different aggregate compositions and different pigments. To evaluate the mortar performance, test procedures will be defined for tests on mortar samples and on composite specimens. In the paper the experimental Programme will be explained and first results will be presented and discussed.
The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in
developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction.
In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered.
The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob.
It has been shown in fire tests that polypropylene fibres reduce or avoid explosive spalling of high performance concrete. In the critical temperature ränge up to 300 °C the permeability of HPC increases by using polypropylene fibre. Due to this the water vapour, which is the main reason for explosive spalling, can escape. There exist different theories in the literature conceming the micro structural mechanisms, which cause an increase in the permeability. Within the framework of an internal research project at BAM an innovative methodology was developed for experimental verifying of existing theories and to get new insights into this problem The methodology used is unique and has been undertaken here for the first time. This consists of the combination of acoustic emission and ultrasonic measurement during temperature loading and the non-destructive micro structural analysis of cooled down samples with the aid of micro X-ray computed tomography. For the validation of the nondestructive test methods scanning electron microscopic images of prepared samples were undertaken. The results show that due to the thermal decomposition of the polypropylene fibres micro canals emerge. These are connected due to a simultaneous micro cack formation.
We studied Brillouin gain spectrum characteristics in dispersion-shifted fibers having compound GeO2-doping compositions in the fiber core to realize simultaneous measurement of distributed strain and temperature. Due to various dopant concentration alongside the radius of tested nonzero dispersion-shifted fibers several multiple Brillouin scattering resonances were observed in the stimulated Brillouin spectra arose through backscattering on higher acoustic modes which propagated along the fiber axis. As a result of the varying acoustic velocities, the Brillouin resonance peaks featured different temperature coefficients which can be used to accomplish the simultaneous measurement of fiber strain and temperature. We presented our first measurement results for NZDS Fujikura and LEAF Corning fiber and discussed the superior sensory suitability of the former fiber types.
Monitoring of fire damage processes in concrete by pore pressure and acoustic emission measurements
(2011)
This paper presents the combined use of acoustic emission (AE), gas pore pressure and temperature measurements (PT). The simultaneous application of both techniques represents a new methodology in the context of fire spalling and contributes to a better understanding of the mechanisms of fire spalling, particular with regard to the interaction of micro cracking and pore pressure evolution. The study presents fire tests on normal strength concrete specimens with and without reinforcement at ISO Standard fire and at hydrocarbon (HC) fire. Supported by AE-analysis, it can be shown that due to the higher heating rate of the HC-fire in comparison to the ISO Standard fire the damage processes inside the concrete during the exposure are increased combined with augmenting the concrete permeability. As a consequence lower pore pressures were measured. However, despite the lower pore pressures, explosive spalling was observed.
Mechanisms of degradation of concrete by external sufate ions under laboratory and field conditions
(2011)
The durability of concrete is a major challenge for the construction, which devotes one third to one half of its annual investment to building maintenance. The lack of fieid data regarding concrete durability, especially in the case of exposure to Sulfate ions (“sulfate attack”) makes it dijficult to determine the appropriate fest methods andperformance criteria. Additionally, the increased use of sustainable blends (cement with mineral admixtures, typically slag from the iron industiy) suffers from a lack of experience regarding their long-term performance. Most results for sulfate resistance are derived from accelerated laboratoiy tests xvhere performance criteria are based only on macroscopic properties, especially expansion. To fill this gap and better widerstand the mechanisms of sulfate attack under real conditions, a parallel study of laboratoiy micro-concrete and fieid concrete samples under sulfate exposure was undertaken, focussing on microstructural changes in addition to the conventional macroscopic characterisation.
Four exposure regimes were designed in the laboratoiy: full immersion (ponding), pH-control, semi-immersion and wet/diy cycles. Pure Portland blends and slag blends witli high level of slag replacement (70 wt.-%) were investigated.
The exposure regime has been found to play a major role in the damage process. In ponding conditions, the damage process takes place in three stages characterised by a first period of induction, followed by surface damage thatfinally extends to the bulle of the material. Paradoxically, the w/c-ratio does not seem to have much impact on the ionic transport phenomena but might be more decisive in the microstructure mechanical strength against local stresses. The slag blends, considered as sulfate resistant in ponding exposure, revealed badperformances under wet/diy cycles. This beliaviour was attributed to poor proper physical resistance of the slag hydrates against diying.
The fieid concretes selected for the comparison with the laboratoiy cases were partially buried in a sulfate-enriched soil in Argentina. A pure Portland blend and a slag blends with high level of slag replacement (80 wt.-%) were investigated. The submerged part of the samples could be compared to the laboratoiy ponding exposure, wliile the upper layer of the samples subjected to weathering could be compared to the laboratoiy wet/diy cycles exposure. The fieid obsen’ations tend to confirm the laboratoiy results and validate the fest settings.
It has been underlined that a direct relationship between damage (e.g.; cracking/expansion) andphase assemblage was not evident. However, the study highlights that sulfate combination with the hydrates of the cement (e.g.; C-S-H) and with those of the slag would play a rote in the initiation of the expansion, which would be attributed to a swelling of the hydrates or to the precipitation offine ettringite after the Saturation level in sulfate of the hydrates has been reached.