Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (122)
- Zeitschriftenartikel (110)
- Beitrag zu einem Tagungsband (74)
- Posterpräsentation (36)
- Sonstiges (14)
- Beitrag zu einem Sammelband (12)
- Buchkapitel (3)
- Dissertation (2)
- Handbuch (2)
- Forschungsbericht (1)
Sprache
- Englisch (376) (entfernen)
Schlagworte
- Corrosion (376) (entfernen)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (145)
- 7.6 Korrosion und Korrosionsschutz (142)
- 5 Werkstofftechnik (55)
- 5.1 Mikrostruktur Design und Degradation (51)
- 6 Materialchemie (34)
- 6.2 Material- und Oberflächentechnologien (26)
- 4 Material und Umwelt (25)
- 4.1 Biologische Materialschädigung und Referenzorganismen (20)
- 8 Zerstörungsfreie Prüfung (12)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (7)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (122)
Unusual Corrosion Behavior of 1.4542 Exposed a Laboratory Saline Aquifer Water CCS-Environment
(2017)
Differently heat treated coupons of 1.4542 were kept at T=60 °C and ambient pressure as well as p=100 bar for 700 h - 8000 h in an a) water saturated supercritical CO2 and b) CO2-saturated synthetic aquifer environment similar to on-shore CCS-sites in the Northern German Basin. Surface corrosion layers are homogeneous but unusually discontinuously ellipsoidal. After 8000 h at 100 bar maximum corrosion rate in the liquid phase is approximately 0.014 mm/year, with normalizing providing best corrosion resistance and approximately 0.003 mm/year in the supercritical phase where hardening+tempering at 670 °C leads to lowest corrosion rates.
This talk demonstrates the results of the IGSTC-project entitled "NDT-Data Fusion".
Project approach:
Nondestructive testing (NDT) of concrete buildings allows to coordinate efficient repair measures. Multi-sensor platforms collect large data sets. Nevertheless, data analysis is typically performed manually. Data Fusion uses the full potential of a multi-sensory data set in order to:
improve information quality (reliability, robustness, accuracy, clarity, completeness) and enables automated algorithm based data analysis.
We present the project achievements, namely:
- Development of building scanner system for multisensory NDT
- Laboratory multi sensor investigations
- Development of data fusion concept for honeycombing and pitting corrosion
- Field testing
Visualization of automated multi‐sensor NDT assessment of concrete structures (NDT Data Fusion)
(2017)
Nondestructive testing(NDT) of concrete buildings allows efficient repair measures. Multi-sensor platforms collect large data sets but the data analysis is typically performed manually. Data Fusion uses the full potential of a multi-sensory data set in order to:
- improve information quality (reliability, robustness, accuracy, clarity, completeness)
- enable automated algorithm based data analysis.
This poster summarizes results of the IGSTC-project entitled "NDT-Data Fusion" (short title) and demonstrates a significant improvement in the testing performance for the example of corrosion detection.
Agar gel pads have been used for electrochemical measurements for some time. For zinc in particular, a standard method for measuring the stability of the corrosion product layer is being established. The main interpretation factor is the corrosion product layer resistance RL, as it is easy to determine and interpret. A high corrosion product layer resistance indicates a high level of protection. However, it is not yet known how low the corrosion product layer resistance is for freshly produced zinc samples. As zinc is highly active, it reacts immediately with the environment to form a corrosion product layer, which affects the corrosion product layer resistance. The addition of zinc acetate to the agar gel pads prevents the formation of a surface layer and destroys existing ones.
This makes it possible to measure an almost corrosion product-free zinc surface. This is important in defining the range of corrosion product layer resistance for a protective surface.
The Stolt Rotterdam tanker ship, filled with nitric acid, was unloading at the Krefeld-Uerdingen terminal on the Rhine River in November 2001. Nitric acid ran out of the stainless steel tanks into the ship's hull and damaged the structural steel. The ship then caught fire and sank at the terminal. Large quantities of nitrogen oxides were emitted, which drifted towards a residential area. Additionally, a mixture of acid and water was introduced into the Rhine River. The area became hazardous to people and the natural environment; however, the imminent danger for the residents and the environment was reduced because of the protective measures against pollution and the good teamwork between local authorities, fire brigades and the Bayer AG company. The acid was drained off of the ship using a controlled discharge of the acid into the river. Through the use of this measure, the ship was salvaged, limiting the pollution to the area and removing the health hazards to the people and the environment. After the ship was salvaged, the river police, along with assistance from the BAM Federal Institute for Materials Research and Testing, impounded the ship and selected corroded parts for further examination. Some of these components have been examined in detail by the BAM. These material investigations contributed to the elucidation of the origin of the leak in the floor panel. The cause of damage was deemed to be a result of a construction flaw at the enamelled valve on the load and discharge pipes.
The results from the comparative corrosion testing using the original structural steel and 60% acid revealed that the valves began to leak at least 8 h prior to the incident at the terminal.
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.