Filtern
Erscheinungsjahr
- 2019 (1913) (entfernen)
Dokumenttyp
- Vortrag (1102)
- Posterpräsentation (325)
- Beitrag zu einem Tagungsband (279)
- Zeitschriftenartikel (95)
- Buchkapitel (31)
- Sonstiges (26)
- Dissertation (15)
- Forschungsbericht (15)
- Monografie (4)
- Beitrag zu einem Sammelband (4)
Sprache
- Englisch (1287)
- Deutsch (610)
- Mehrsprachig (13)
- Russisch (2)
- Spanisch (1)
Referierte Publikation
- nein (1913) (entfernen)
Schlagworte
- Additive Manufacturing (49)
- Corrosion (49)
- Korrosion (45)
- LIBS (30)
- Additive manufacturing (27)
- Concrete (26)
- Fluorescence (26)
- Nanoparticles (24)
- Additive Fertigung (22)
- Ultraschall (22)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (390)
- 7 Bauwerkssicherheit (308)
- 6 Materialchemie (274)
- 1 Analytische Chemie; Referenzmaterialien (236)
- 3 Gefahrgutumschließungen; Energiespeicher (188)
- 9 Komponentensicherheit (188)
- 4 Material und Umwelt (186)
- 5 Werkstofftechnik (139)
- 2 Prozess- und Anlagensicherheit (133)
- 7.6 Korrosion und Korrosionsschutz (114)
Eingeladener Vortrag
- nein (1102)
In diesem Verbundvorhaben werden standardisierte Messverfahren für hybride Gemische erarbeitet, die der Bestimmung sicherheitstechnischer Kenngrößen des Explosionsschutzes dienen. Unter einem hybriden Gemisch wird dabei ein mehrphasiges System aus Brenngas oder brennbarem Dampf, sowie Luft und brennbarem Staub verstanden. Die Veröffentlichung der Ergebnisse erfolgt in einem Abschlussbericht und als DIN-Spezifikation (DIN SPEC). Diese DIN SPEC versetzt Prüfinstitute und Industrie in die Lage, Explosionsgefahren beim Betrieb technischer Anlagen mit hybriden Gemischen einzuschätzen und damit Prozesse sowohl sicherer als auch effizienter zu steuern. Dieses Projekt wird im Rahmen des WIPANOProgramms (Wissens- und Technologietransfer durch Patente und Normen) vom BMWi gefördert.
Demonstrationsexperimente
(2019)
Korrosionsprüfung
(2019)
Titanium dioxide is one of the most studied metal oxides due to its chemical, surface, electronic and (photo)catalytic properties, providing this material of multisectorial applications ranging from healthcare, photocatalysis, smart materials with self cleaning and self sterilizing properties and solar energy harvesting. However it is difficult to correlate the functional properties of TiO2 nanomaterials to the properties at single nanoparticle level due to the high polydispersity in shape, size and surface features of the currently available TiO2 nanoparticles (NPs). Although intensive experimental and theoretical studies have been conducted on the reactivity of different surfaces of metal oxides such as TiO2 much less attention is paid on the dependence of functional properties, like photocatalytic activity, dye adsorption, open circuit potential and fill factor in dye sensitized solar cells, on crystal facets in different orientations. One of the goal of SETNanoMetro project was the development of design rules to tune crystal facets of TiO2 NPs in order to optimize and control functional properties. In the present work we have developed a series of design rules in order to obtain sets of anatase TiO2 NPs with low polydispersity and to tune their shape and size by hydrothermal processing of Ti(IV)-
Triethanolamine complex in presence of different shape controllers. Through a careful experimental design, a predictive soft model was developed. The model is able to predict the synthesis outcome allowing to tune the shape factor from 5 (prisms) to 1.5 (bipyramids) to 0.2 (platelets). This allows to control the main crystal facets exposed ranging from (100) to (001). Due to the dependence of functional properties of nanomaterials on shape distribution and not only size, the availability of NPs sets with uniform and well defined and tunable shapes can be of paramount relevance in order to produce reference nanomaterials for shape measurement.
The European Commission's recommendation on the definition of nanomaterial [2011/696/EU] is broadly applicable across different regulatory sectors and requires the quantitative size Determination of constituent particles in samples down to 1 nm. A material is a nanomaterial if 50 % or more of the particles are in the size range 1-100 nm. The implementation of the definition in a regulatory context challenges measurement methods to reliably identify nanomaterials and ideally also nonnanomaterials as substance or product ingredient as well as in various matrices.
The EU FP7 NanoDefine project [www.nanodefine.eu] addressed these challenges by developing a robust, readily implementable and cost-effective measurement strategy to decide for the widest possible range of materials whether it is a nanomaterial or not. It is based on existing and emerging particle measurement techniques evaluated against harmonized, material-dependent performance criteria and by intra- and inter-lab comparisons. Procedures were established to reliably measure the size of particles within 1-100 nm, and beyond, taking into account different shapes, coatings and chemical compositions in industrial materials and consumer products. Case studies prove their applicability for various sectors, including food, pigments and cosmetics.
A main outcome is the establishment of an integrated tiered approach including rapid screening (Tier 1) and confirmatory methods (tier 2), a decision support flow scheme and a user manual to guide end-users, such as manufacturers, in selecting appropriate methods. Another main product is the “NanoDefiner” e-Tool which implements the flow scheme in a user-friendly software and guides the user in a semi-automated way through the entire decision procedure. It allows a cost-effective selection of appropriate methods for material classification according to the EC's nanomaterial definition and provides a comprehensive report with extensive explanation of all decision steps to arrive at a transparent identification of nanomaterials as well as non-nanomaterials for regulatory
purposes.
Extraction of true, 3D shape (and size) of non-spherical nanoparticles (NPs) is associated with Errors by conventional 2D electron microscopy using projection images. Significant efforts within the ISO technical committee TC 229 ‘Nanotechnologies’ are aimed at establishing accurate TEM and SEM measurement of NP size and shape as robust, standard procedures. Study groups have been organizing inter-laboratory comparisons on well-selected NP systems according to the market needs, such as aggregated titania nano-powder for which size and shape distribution of primary crystallites of irregular shape must be measured accurately. To be noticed is e. g. the fact that the measurement procedure allows only manual selection of the particles clearly distinguishable for analysis as well as manual definition of the contour of the imaged NPs.
An inter-laboratory exercise on titania NPs (pure anatase, grown by hydrothermal synthesis) of well-defined non-spherical shape, i.e. bipyramidal, has been recently started within ISO/TC 229 under similar conditions as for the irregular shaped titania. In the TEM micrograph the particles tracked manually according to the measurement protocol. Overlapped particles were allowed to be considered, as long as they are clearly distinguishable. One decisive NP selection criterion was to analyze only those NPs with a roundness value below 0.7, i.e. the NPs laying on the support foil and, hence, with projection areas clearly deviating from perfect circles (R=1). The overall evaluation (for 15 labs) of the size descriptors (area, Feret, minFeret, perimeter) and shape descriptors (aspect ratio, roundness, compactness, extent) by analysis of variance is just to be finished and included in ISO/WD 21363 Nanotechnologies -- Protocol for particle size distribution by transmission electron microscopy.
Bei der Explosion in einer Herstellungsstätte für ein Pulver zur Reinigung industrieller Feuerungsanlagen in Deutschland ist eine Person tödlich verunglückt. Die BAM wurde gebeten, beschlagnahmte Muster des Reinigungspulver zu bewerten. Dafür wurden verschiedene Untersuchungen durchgeführt. Diese sollten klären, ob die stoffliche Einstufung des Reinigungspulvers in die Stoffklasse 5.1 für die sichergestellten Pulverproben zutreffend ist. Es konnte nachgewiesen werden, dass die untersuchten Pulverproben explosionsgefährliche Eigenschaften aufweisen. Die von explosionsgefährlichen Stoffen ausgehenden Gefährdungen müssen ermittelt und bei der Herstellung und Verwendung berücksichtigt werden. Die Gefährdungen sind entsprechend neu eingeführter sicherheitstechnischer Kennzahlen ermittelt und anschließend klassifiziert worden. Die Klassifizierung erfolgte durch die Zuordnung zu einer s.g. Gefahrgruppe.
GPS-data based calculation scheme for assessing, in real-time, the level of safety exerted during driving, has been described and used. The several variables involved considered the main factors that lead to road mishaps, including the speed, the acceleration and the effects that these variables have on the vehicle when it is negotiating a turn. The performance measure combines three individual performance outputs: speed, acceleration and a hybrid performance measure considering the speed, the acceleration and the change in latitude/longitude. The measures are designed in such a way that weighting factors can be calibrated in order to establish certain critical parameters. On the other hand, the terms in the equations preclude any division by zero of the involved ratios. On the other hand, the simplicity of the equations makes it possible to carry out the assessment in real time. The use of the resultant performance measure to a relatively long path, together with its current average value, indicates that the safe performance of the driving changes with time, and that, for the selected values of the calibration constants, the traveling speed dominates the overall safety performance of the driving. Furthermore, the different calibration constants provide the possibility of considering different types of hazmat carrying vehicles. While many other formulation components could be integrated into the performance measure, this three-component performance measure could be used to assess the driving of a hazmat-carrying vehicle, in order to detect and to prevent dangerous conditions, such as driver fatigue.
Finally, the implementation of the different performance measure formulations in a system such as the one described in the introduction of this paper, could be straightforward.