19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used.
Laser-induced plasmas are widely used in many areas of science and technology; examples include spectrochemical analysis, thin film deposition, material processing, and even jet propulsion. Several topics will be addressed. First, general phenomenology of laser-induced plasmas will be discussed. Then, a chemical model will be presented based on a coupled solution of Navier-Stokes, state, radiative transfer, material transport, and chemical (Guldberg-Waage) equations. Results of computer simulations for several chemical systems will be shown and compared to experimental observations obtained by optical imaging, spectroscopy, and tomography. The latter diagnostic tools will also be briefly discussed.
The spatial heterodyne detection principle has a great potential in spectroscopy. It has an optical setup similar to that of a Michelson interferometer, with the mirrors replaced by diffraction gratings positioned at fixed, equal distances from the beamsplitter and are slightly tilted. The resulting interference pattern is recorded by a digital camera and the spectrum is recovered by using Fourier transformation. Although SHS was initially developed for astronomical and satellite-based atmospheric measurements, but in recent years it has been started to be applied in other branches of spectroscopy too. Recently the area of laser-induced breakdown spectroscopy (LIBS) has also discovered the potential of SHS. The main appeal of SHS detection in LIBS includes the compactness and robustness of the setup (in view of field applications) and the flexibility to optimize the setup for either high sensitivity or for high resolution, which can be benficially exploited in applications like stand-off measurements, quantitative analysis with isotope resolution, etc.
In the present work, we have improved and further optimized our initial LIBS-SHS setup described in a previous conference. By using optical simulations, we have modelled the light transmission efficiency, instrumental function and imaging properties of the system. We significantly improved and automated the spectral and image data processing sequence. The optimizations carried out resulted in an improved spectral resolution and repeatability, a lower spectral background and the elimination of the central line artifact originating from the Fourier transformation procedure. A detailed characterization of the LIBS spectroscopy performance (e.g. resolution, spectral coverage, tuning range, linearity, etc.), including a comparison with that of a LIBS setup based on a conventional dispersion CCD spectrometer was also performed.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.
A goal of this work is to extend the model, which was initially developed for laser induced plasmas, to plasmas used in chemical reactors, in particular, the inductively-coupled-RF discharge plasma. The model predicts equilibrium chemical compositions of reaction mixtures as functions of plasma temperature and stoichiometry of reactants. The mixtures investigated are BCl3/H2/Ar and BF3/H2/Ar where Ar serves as the plasma-forming gas and H2 as a binding agent which binds the active species Cl and F and Cl- and F-containing intermediates to produce gaseous B and its condensate. An additional goal is to obtain information about intermediate reaction products for different ratios of BCl3/H2 and BF3/H2 and at different temperatures and different Ar flow rates.
It is found that the desired components B and B2 appear at appreciable concentrations of >0.1% and ~0.01% respectively only at temperatures above 3000 K. It is also established that the effect of charged species on the reaction products is miniscule for temperatures below 5000 K. The expected yield of boron as a function of the original mole fraction H2/BCl3 and H2/BF3 is calculated. The mole fractions are varied in the range 0.1-1000 and the temperature in the range 1000-10000 K. It is shown that the yield of boron increases with increasing the molar ratio H2/BCl3 and H2/BF3 up to ~100 in the temperature range 2000-5000 K. At higher temperatures, T>5000 K, the boron concentration reaches its maximum and does not depend on the concentration of hydrogen; all molecules dissociate and chemical reactions proceed only between charged particles (mostly elemental ions) and electrons. The calculated plasma parameters and composition are compared with experimental data obtained by optical emission spectroscopy. The calculated plasma temperature and electron density are shown to be in good agreement with the measured ones.
High purity halides of III-VI group elements, especially chloride and fluorides, are used in gas phase technologies for obtaining high purity materials and coatings. The reduction of halides in hydrogen-halide mixtures can be achieved in various discharge plasmas, e.g. inductively coupled, ark, and even laser-induced plasmas. Existing models of such plasmas are not sufficiently accurate to predict a yield of the targeted compounds and to describe the plasma processes involved in formation of these compounds. Besides, a construction of costly plasma-chemical reactors can be alleviated by the prior modeling of plasma processes that may occur in such reactors.
A goal of this work is to extend the model, which was initially developed for laser induced Plasmas, to plasmas used in chemical reactors, in particular, the inductively-coupled-RF discharge Plasma. The model predicts equilibrium chemical compositions of reaction mixtures as functions of plasma temperature and stoichiometry of reactants. The mixtures investigated are BCl3/H2/Ar and BF3/H2/Ar where Ar serves as the plasma-forming gas and H2 as a binding agent which binds the active species Cl and F and Cl- and F-containing intermediates to produce gaseous B and its condensate. An additional goal is to obtain information about intermediate reaction products for different ratios of BCl3/H2 and BF3/H2 and at different temperatures and different Ar flow rates.
It is found that the desired components B and B2 appear at appreciable concentrations of >0.1% and ~0.01% respectively only at temperatures above 3000 K. It is also established that the effect of charged species on the reaction products is miniscule for temperatures below 5000 K. The expected yield of boron as a function of the original mole fraction H2/BCl3 and H2/BF3 is calculated. The mole fractions are varied in the range 0.1-1000 and the temperature in the range 1000-10000 K. It is shown that the yield of boron increases with increasing the molar ratio H2/BCl3 and H2/BF3 up to ~100 in the temperature range 2000-5000 K. At higher temperatures, T>5000 K, the boron concentration reaches its maximum and does not depend on the concentration of hydrogen; all molecules dissociate and chemical reactions proceed only between charged particles (mostly elemental ions) and electrons. The calculated plasma parameters and composition are compared with experimental data obtained by optical emission spectroscopy. The calculated plasma temperature and electron density are shown to be in good agreement with the measured ones.
The presented work discusses the accuracy of Laser Induced Breakdown Spectroscopy (LIBS) in determining the total chloride content in cement pastes. LIBS as an emission spectroscopy method is used to detect simultaneously several elements present in cement-based materials. By scanning surfaces the variability in the spatial distribution of elements can be visualised. However, for a quantification of the results, studies are necessary to characterise possible influences due to the wide variation of the chemical compositions in which cement can occur. It is shown how the calibration can be done, how the calibration samples were produced, and which statistical parameters are necessary to describe the precision of the regression. The performance of LIBS is estimated by detecting chloride in validation samples. Therefore, 55 samples and 7 ets with changing mix ompositions were produced. The presented study deals with possible influences of different mix compositions, ncluding different cations of chloride, varying w/c-ratios and the artial replacement of Portland cement with last furnace slag (50% BFS) and limestone (30% LS). Comparing the LIBS results with otentiometric titration, n accuracy of±0.05 wt%/total has been determined.