Filtern
Erscheinungsjahr
- 2019 (1913) (entfernen)
Dokumenttyp
- Vortrag (1102)
- Posterpräsentation (325)
- Beitrag zu einem Tagungsband (279)
- Zeitschriftenartikel (95)
- Buchkapitel (31)
- Sonstiges (26)
- Dissertation (15)
- Forschungsbericht (15)
- Monografie (4)
- Beitrag zu einem Sammelband (4)
Sprache
- Englisch (1287)
- Deutsch (610)
- Mehrsprachig (13)
- Russisch (2)
- Spanisch (1)
Referierte Publikation
- nein (1913) (entfernen)
Schlagworte
- Additive Manufacturing (49)
- Corrosion (49)
- Korrosion (45)
- LIBS (30)
- Additive manufacturing (27)
- Concrete (26)
- Fluorescence (26)
- Nanoparticles (24)
- Additive Fertigung (22)
- Ultraschall (22)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (390)
- 7 Bauwerkssicherheit (308)
- 6 Materialchemie (274)
- 1 Analytische Chemie; Referenzmaterialien (236)
- 3 Gefahrgutumschließungen; Energiespeicher (188)
- 9 Komponentensicherheit (188)
- 4 Material und Umwelt (186)
- 5 Werkstofftechnik (139)
- 2 Prozess- und Anlagensicherheit (133)
- 7.6 Korrosion und Korrosionsschutz (114)
Eingeladener Vortrag
- nein (1102)
In additive manufacturing (AM) Laser Metal Deposition (LMD), parts are built by welding layers of powder feedstock onto a substrate. Applications for steel powders include forging tools and structural components for various industries. For large parts, the choice of tool-paths influences the build-rate, the part performance and the distortions in a highly geometry-dependent manner. With weld-path lengths in the range of hundreds of meters, a reliable, automated tool path generation is essential for the usability of LMD processes.
In this contribution, automated tool-path generation approaches are shown and their results are discussed for arbitrary geometries. The investigated path strategies are the classical approaches: “Zig-zag-” and “contour-parallel-strategies”. After generation, the tool-paths are automatically formatted into g-code for experimental build-up and ASCII for a numerical simulation model. Finally, the tool paths are discussed in regards to volume-fill, microstructure and porosity for the experimental samples.
This work presents a part of the IGF project 18737N “Welding distortion simulation” (FOSTA P1140)
Täglich werden mehrere tausend Tonnen in Säcken verpackter Gefahrgüter über die Straßen transportiert. Laut den internationalen Gefahrgutvorschriften für den innerstaatlichen und grenzüberschreitenden Verkehr ADR müssen Gefahrgutsäcke aus Papier „staubdicht“ sein. Die Autobahnpolizei Münster wies bei einem Vortrag in der BAM darauf hin, dass im Rahmen polizeilicher LKW-Kontrollen Ladeflächen voller Staub vorgefunden wurden, ohne dass ein Defekt an einem Gefahrgutsack festgestellt werden konnte.
Ziel der Arbeit war es, eine Prüfkammer zu entwickeln, welche in der Lage ist, nach Fallversuchen mit Gefahrgutsäcken aus Papier den freigesetzten luftgetragenen Staub zu bestimmen. Eine anschließende Bewertung soll die gesundheitlichen Gefahren des entstandenen Aerosols aufzeigen. Durch die Auswertung erster Fallversuche wurde exemplarisch die „Dichtheit“ vorhandener Gefahrgutsäcke bestimmt und die Fraktionen der entstandenen Aerosole wurden mit den Arbeitsplatzgrenzwerten verglichen.
The current competitive situation on electricity markets forces power plants into cyclic operation regimes with frequent load shifts and starts/shutdowns. In the present work, the cyclic mechanical behavior of ferritic-martensitic 9-12 % Cr steels under isothermal and thermomechanical loading was investigated for the example of grade P92 material. A continuous softening was observed under all loading conditions. The introduction of hold periods to the applied cycles reduced material lifetime, with most prominent effects at technologically relevant small strain levels. The microstructural characterization reveals a coarsening of the original “martensitic” lath-type microstructure to a structure with polygonal subgrains and reduced dislocation density. The microstructural data forms the input for a physically-based modelling approach, both of which are presented in “Part 2: Microstructural Evolution during Cyclic Loading and its Representation in a Physically-based Micromechanical Model“.
The current competitive situation on electricity markets forces conventional power plants into cyclic operation regimes with frequent load shifts and starts/shutdowns. In the present work, the cyclic mechanical behavior of ferritic-martensitic 9-12 % Cr steels under isothermal and thermomechanical loading was investigated for the example of grade P92 material. A continuous softening was observed under all loading conditions. The introduction of hold periods to the applied cycles reduced material lifetime, with most prominent effects at technologically relevant small strain levels. The microstructural characterization reveals a coarsening of the original “martensitic” lath-type microstructure to a structure with polygonal subgrains and reduced dislocation density. The microstructural data forms the input for a physically-based modelling approach.
Diese DIN SPEC legt ein Verfahren für die Prüfung von unverstärkten und partikel- und kurzfaserverstärkten Kunststoffen mittels Zug-Druck-Schubprüfung fest. Dieses Verfahren findet Anwendung zur Bestimmung der Schwingfestigkeit im Bereich von 103 bis 107 Schwingspielen und der Nachgiebigkeiten unter statischer Belastung sowie der Zugfestigkeit. Alle Beanspruchungen und berechneten Größen sind nennspannungs-basiert.
Grundsätzlich besteht bei Rohrprobekörpern auch die Möglichkeit eine Beanspruchung in Längs- und in Umfangsrichtung durch Innendruck zu erzeugen. Dies wird in dieser Spezifikation nicht berücksichtigt, um die Anwendung überschaubar zu halten. Bei Rohrproben mit ausgeprägter Querschnittsverkleinerung (z. B. der Prüfkörper Typ B), entsteht eine Umfangsspannung auch aufgrund einer Zugkraft (siehe Anhang C). Die Umfangsspannung muss dann mittels FEA lokal berechnet werden.
Das Verfahren gilt für rohrförmige Prüfkörper deren spezifische Form den Anforderungen der Werkstoff-prüfung und bei Kurzfaserverstärkung einer hohen Vorzugsausrichtung in Probenlängsrichtung genügen.
Diese DIN SPEC gilt nicht für endlosfaserverstärkte Kunststoffe. Wegen der vollkommen unterschiedlichen Fertigungstechnologien und der zu erwartenden hohen Prüflasten, sind hier die Anforderungen an die Prüfkörpergeometrie gesondert zu betrachten. Es wird nicht zielführend sein, beide Werkstoffklassen in einer Norm zu behandeln.
Commercially available air-coupled transducers applied in non-destructive testing consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air. Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.
Spherical mesoporous bioactive glasses in the silicon dioxide (SiO2)-phosphorus pentoxide (P2O5)–calcium oxide (CaO) system with a high specific surface area of up to 300m2/g and a medium pore radius of 4 nm were synthesized by using a simple one-pot surfactant-assisted sol–gel synthesis method followed by calcination at 500–700°C. The authors were able to control the particle properties by varying synthesis parameters to achieve microscale powders with spherical morphology and a particle size of around 5–10 mm by employing one structure-directing agent. Due to a high Calcium oxide content of 33·6mol% and a phosphorus pentoxide content of 4·0mol%, the powder showed very good bioactivity up to 7 d of immersion in simulated Body fluid. The resulting microspheres are promising materials for a variety of life science applications, as further processing – for example, granulation – is unnecessary. Microspheres can be applied as materials for powder-based additive manufacturing or in stable suspensions for drug release, in bone cements or fillers.
Based on the burst test results conducted at BAM, loading rates will affect the strength of composite pressure vessels (CPV). The multiscale fibre-break model developed at Mines ParisTech is able to described this behaviour explained by the stress relaxation in the viscoelastic matrix. The experiment showed an increase of burst pressure when an extreme slow loading rate is used compare to the slow loading rate. Is is then discovered that the model could predict well for the slow loading rate but not for the extreme slow loading rate. It may have something to do with the fibre re-orientation of the hoop layer during the extreme slow loading rate test. Further investigation is required to discover this hypothesis.
Vortrag zur Bestimmung von Nichtmetallen in Carbiden halten.
Hierbei geht es um die Bestimmung von C, O und N in Vanadiumcarbid, Wolframcarbid und Niobcarbidmaterialien, einen hierzu durchgeführten Ringversuch mit Beteiligung der Kollegen des AK Sonderwerkstoffe und den Vergleich von Verfahrenskenngrößen.
Metal phosphonates are promising materials for applications in fuel cells, due to their high proton conductivity and higher chemical and thermal stability compared to the industry standard (e.g. Nafion®). Additionally, metal phosphonates are precursors to porous carbon materials with evenly distributed centers for ORR catalysis. As a fast and sustainable synthesis, mechanochemistry is the synthesis method of choice. Thorough characterization is carried out by XRD, MAS-NMR, XAS, BET, and DVS.
We present a technique for distributed temperature gradient sensing in real-time along an optical fiber utilizing simple amplitude-based direct-detection coherent optical time domain reflectometry (C-OTDR) and a special sensing fiber. Our technique enables us to determine phase changes or low-frequency variations of the C-OTDR signal stemming from temperature variations. The distinct feature of the used sensing fiber is its structuring with equidistant strongly scattering dots. Consecutive pairs of these scatterers form the dominant local interferometers, effectively overwriting the otherwise highly nonlinear transfer function of common optical fiber. This enables a quasi-phase-resolved evaluation of perturbation responses originating from temperature changes at sensor positions between the scatterers. Using our method, we show the measurement of a nonlinear temperature transient from a heating process with a maximum temperature gradient of 0.8 °C over 20 s and a total temperature increase of 28.4 °C. This method requires almost no post-processing and can be used for simultaneous distributed vibration sensing (DVS) and quantification of local temperature gradients in a single fiber, e.g., for the use in condition monitoring of infrastructure or industrial installations.
In den letzten Jahren wurden enorme Fortschritte bei der additiven Fertigung erzielt. So sind heutzutage industrielle Kleinserienfertigungen mit den 3D-Druckverfahren wirtschaftlich und konkurrenzfähig. Allerdings ist der Einsatz in Bezug auf sicherheitsrelevante Komponenten noch nicht vollumfänglich möglich. Grund hierfür sind die Materialeigenschaften 3D-gedruckter Komponenten, welche sich von den Eigenschaften konventionell gefertigter Materialien unterscheiden (Variationen im Gefüge, der Härte usw.). Ein Ansatz zur Lösung dieses Problems ist der Einsatz geeigneter online-Prüfverfahren zur Qualitätssicherung. Diese befinden sich –abgesehen von kamerabasierten Verfahren– aber noch im Entwicklungsstadium. Bei metallischen Werkstoffen stellt die Wirbelstromprüfung ein geeignetes Verfahren zur lagenweisen Online-Überprüfung des Fertigungsprozesses dar.
Der Beitrag gibt einen Überblick über die derzeitige Patentlage sowie den Stand der Forschung zum Einsatz der Wirbelstromprüfung beim 3D-Druck metallischer Komponenten. Am Beispiel des pulverbasierten SLM-Verfahrens (selective laser melting; selektives Laserschmelzen) werden zudem Arbeiten der BAM und erste Ergebnisse einer angepassten Wirbelstromtechnik unter Verwendung von GMR-Sensoren (giant magneto resistance) vorgestellt. Hier wird das Ziel verfolgt, hochauflösend kleinste Fehler und Poren (im Bereich ≈100 µm) in der Oberfläche zu detektieren und durch lagenweises Abrastern einen 3D-Datensatz für die Qualitätskontrolle zu erstellen. Schließlich soll das System in der Lage sein, aktiv in den Fertigungsprozess einzugreifen, wodurch entweder die Produktion fehlerhafter Bauteile gestoppt wird oder durch geeignete Maßnahmen Fehler ausgeheilt werden.
The Weimar research project has set the goal of placing style-critical research on Old Master drawings on a new, methodologically proven foundation. The starting point is the stock of Dutch drawings possessed by the Klassik Stiftung Weimar, whose extent (ca. 1,400 items) and character make it one of the most significant outside the Netherlands. The focus here is on drawings that were executed with red chalk. This drawing material has different functions - one of which is the use as a transmission material. The methodological approach is double: first, the scientific indexing of this stock. The foundations for this, along with classic analysis of style, are innovative material-scientific methods of investigation.
Prüfapparaturen zur Bestimmung sicherheitstechnischer Kennzahlen müssen präzise messen, um verlässliche Ergebnisse zu produzieren. Oftmals gibt es in der Methodenbeschreibung allerdings keine Informationen zu Messunsicherheiten o.ä.. In dem Vortrag werden Ringversuchsprogramme das CEQAT-DGHS beschrieben und aktuelle Arbeiten zu Verifizierungsverfahren von Messmethoden beschrieben.
Der Fokus des Beitrages bestand darin, die BAM, insbesondere die Abteilung 2 (Chemische Sicherheitstechnik) als möglichen Projektpartner im Rahmen von Horizont 2020 "Sichere Gesellschaften" zu präsentieren. Dabei wurden die Kernkompetenzen der Abteilung 2, die Kooperationen zu anderen Abteilungen in der BAM bzw. einige Beispiele zu bisherigen Projekterfahrungen, hinsichtlich dem Aktivitätsfeld "Security" vorgestellt.
Fluorescent molecularly imprinted polymers (MIPs) for sensing of phosphorylated protein epitopes
(2019)
Early detection of cancer is instrumental for successful therapeutic outcomes, but it is presently a considerable challenge. Biopsy of potentially cancerous tissues is the gold standard in medicine for the diagnosis and prognosis of this disease; however, it may not be possible in many cases due to tumour position or other complications. Liquid biopsy-based detection of specific cancer markers in biological fluids can be easily performed via immunoanalytical techniques. However, antibody-based methods suffer from high cost of tumour specific antibodies due to difficult and lengthy production. Furthermore, antibodies may have limited specificity to the target molecule, and limited lifetimes. The so-called “plastic antibodies” as MIPs can be a more affordable, reliable and stable alternative to antibodies, especially for cancer diagnostics.
Our goal is to create MIP particles to selectively bind cancer biomarkers and rapidly display a fluorescence change upon interaction with molecules of interest. Epitopes containing the phosphorylated tyrosine (pY) motif such as tripeptide YpYG and tetrapeptide pYEEI were selected as target analytes. Cancers may disrupt tyrosine phosphorylation processes regulated by human tyrosine kinases such as ZAP-70 and subsequently lead to a pronounced increase in pY residues on proteins. To ensure fast diffusion of analyte and rapid response core/shell silica micro- and nanoparticles with a thin polymer shell was chosen as the format for MIP synthesis. Fluorescent probe monomers consisting of fluorophore and recognition units are directly integrated in the polymer shell to obtain fluorescence response upon analyte binding.
We have synthesized the fluorescent MIP particles based on the previously published report for the novel phosphorylated targets with a high imprinting factor and high degree of discrimination between target analyte and non-phosphorylated and smaller competitors. The synthesized particles may be used in microfluidic devices for the rapid diagnostics of cancer.
Der Vortrag vermittelt einen Überblick über die physikalischen Gefahren nach der CLP-Verordnung (Verordnung (EG) Nr. 1272/2008), die Schnittstelle zum global harmonisierten System zur Einstufung und Kennzeichnung auf Grundlage des UN Manual of Tests and Criteria, die Bedeutung der Qualitätssicherung bei Prüfungen auf physikalische Gefahren, sowie die Prüf- und Bewertungsstrategien und welche Tests dabei unverzichtbar sind.