Filtern
Erscheinungsjahr
- 2021 (41) (entfernen)
Dokumenttyp
- Posterpräsentation (41) (entfernen)
Referierte Publikation
- nein (41)
Schlagworte
- Computed tomography (4)
- X-ray imaging (3)
- X-ray refraction (3)
- Zerstörungsfreie Prüfung (3)
- Computertomographie Simulation (2)
- Dental materials (2)
- Human Factors (2)
- Iteration method (2)
- LIBS (2)
- Localization (2)
- Luftgekoppelte Ultraschallprüfung (2)
- Nano aerial robot (2)
- Non-destructive testing (2)
- Signal processing (2)
- Thermography (2)
- Trail detection (2)
- Trail following (2)
- Ultraschall (2)
- Ultrasound (2)
- X-ray fluorescence (2)
- Zuverlässigkeit (2)
- Abdichtbauwerk (1)
- Additive Fertigung (AM) (1)
- Additive manufacturing (1)
- AlSi10Mg (1)
- AlSi10Mg alloy (1)
- Alcali activated binders (1)
- Alkali-Activated Mortars (1)
- Ambient seismic noise measurements (1)
- BAMline (1)
- Bohrlochsonde (1)
- Bridge Monitoring (1)
- Building waste (1)
- CMAS - Calcium-Magnesium-Aluminiumsilikat (1)
- Cement (1)
- Cemented waste (1)
- Charakterisierung (1)
- Charakterisierung von Brennflecken (1)
- Chloride (1)
- Chlorine (1)
- Circular economy (1)
- Coda Wave Interferometry (1)
- Coda wave interferometry (1)
- Composites (1)
- Computational physics (1)
- Computertomographie (1)
- Defect detection (1)
- Distributed sensing (1)
- DoE (1)
- Endlager (1)
- Environmental monitoring (1)
- Faseroptischer Strahlungssensor (1)
- Feuchte (1)
- Feuchtegehalt (1)
- Fiber optic radiation sensor (1)
- Fiber reinforced dental post (1)
- Fiberglass composite (1)
- Finite element method (1)
- Finite volume method (1)
- Fluidic devices (1)
- Frequenzbereichsreflektometrie (1)
- Fußboden (1)
- Heat treatment (1)
- Image resolution (1)
- In-situ Monitoring (1)
- In-situ heat treatment (1)
- Inspection (1)
- Interlaboratory comparison (1)
- L-PBF (1)
- Laser Powder Bed Fusion (1)
- Laser induced breakdown spectroscopy (1)
- Laser powder bed fusion (1)
- Machine learning (1)
- Material sorting (1)
- Monitoring (1)
- NDT (1)
- NMR (1)
- Neutronensonde (1)
- Numerische Simulation (1)
- Oberflächenrelaxivität (1)
- Ortsaufgelöste Fasersensorik (1)
- Ortsauflösende Fasersensorik (1)
- Passive sensor interface (1)
- Photothermisch (1)
- Polyamid 12 (1)
- Porosity growth (1)
- Porosität (1)
- Pre-stress loss (1)
- Probability of detection (1)
- Qualitätssicherung (1)
- RFID (1)
- Radar (1)
- Radiation sensing fibers (1)
- Radiation-induced attenuation (1)
- Radioactive waste disposal (1)
- Radiographie (1)
- Rayleigh-Streuung (1)
- Residual stress (1)
- Richtlinie (1)
- Round robin (1)
- Röntgenrefraktion (1)
- Röntgenröhren (1)
- SXRR - Synchrotron X-ray Refraction Radiography (1)
- Sandsteine (1)
- Scientific software (1)
- Sensor placement (1)
- Sequential learning (1)
- Simulation (1)
- Standardisierung (1)
- Strahlungsinduzierte optische Dämpfung (1)
- Structural Health Monitoring (1)
- Structural health monitoring (1)
- Strukturiert (1)
- Super resolution (1)
- Super-resolution (1)
- Synchrotron refraction radiography (1)
- TBC (1)
- Thermal barrier coatings (1)
- Thermografie (1)
- Thermoplastische Kunststoffe (1)
- Tomographie (1)
- Tomography (1)
- Ultraschall-Echoverfahren (1)
- Ultraschallwandler (1)
- Variational calculation (1)
- Verschlussbauwerk (1)
- Verschlussbauwerke (1)
- Wireless sensor network (1)
- ZfP (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (41) (entfernen)
Radiografische Simulationswerkzeuge wie aRTist, ScorpiusXLab, SimCT oder CIVA CT verwenden analytische Methoden und physikalische Monte-Carlo-Teilchentransportsimulationen, um die Interaktionsprozesse zwischen Röntgenstrahlung und Materie zu simulieren. Die berechneten Projektionen bilden anschließend unter Berücksichtigung einer definierten Scan-Trajektorie die Basis der Simulation einer röntgencomputertomografischen Untersuchung.
Radiografische Simulationswerkzeuge befinden sich in einem stetigen Wandel, beispielsweise durch die Entwicklung neuer Rekonstruktionsmethoden, durch Erweiterung von analytischen Modellen, durch Integration komplexer Trajektorien oder durch Berücksichtigung von prozessbedingten geometrischen Abweichungen. Im laufenden EMPIR-Projekt „AdvanCT“ entsteht deshalb ein „Good Practice Guide“ für die Simulationsumgebung aRTist. Ziel dieses Guides ist es, die mit steigender Komplexität verbundenen Einstiegshürden für Anwender von aRTist zu reduzieren, um damit einen praxisnahen Zugang zur virtuellen Computertomografie zu ermöglichen. Dabei werden anhand von praktisch nachvollziehbaren Beispielen die grundlegenden Mechanismen der Simulationsumgebung erklärt und ein strukturierter Leitfaden zur Simulation röntgencomputertomografischer Untersuchungen mit aRTist vermittelt. In diesem Beitrag werden erste Auszüge des Guides sowie eine Übersicht der weiteren geplanten Themen für die anschließende Diskussion vorgestellt.
Sensors can fail. Redundancy should therefore be a design driver of wireless sensor networks. For a sensor network deployed in a steel factory, we analyze the correlations between sensors and build machine learning forecasting models, to investigate how well the network can compensate for the outage of sensors.
This poster presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize the chemical trail, a novel detection criterion was developed that uses only relative changes in the transient phase of the sensor response, making it more robust in its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot is able to correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future.
To conduct a reliable, repeatable and accurate LIBS analysis, the optimization of the experimental setup is an important task. Hardware parameters of lasers and spectrometers used in the setup as well as additionally required components such as optics or process gas pipes must be carefully aligned and adjusted because factors like (i) focal conditions of the optics, (ii) alignment of the sample, (iii) process purge gas (types, flow rate) or (iv) measurement settings (integration time, accumulation of pulses) have a big impact on the signal quality. Therefore, in most cases the effect of different factors is evaluated empirically due to changing one factor at a time while keeping the overall configuration the same. In the end, the optimal configuration is selected based on the best parameters for each influencing factor. During optimization, a configuration of the experimental setup is aimed at, which allows e.g. the highest signal intensity or the lowest variation. In most cases, cross-correlation, interference and interaction among the various factors are not considered. For this reason, the possibilities of using Design of Experiment (DoE) to optimize a LIBS experiment will be shown and advantages of (i) reduction of testing plans using a feature space, (ii) identifying and considering cross-correlations and interactions, (iii) evaluating individual impacts on the measurement (e.g. contour and surface plots) as well as (iv) multivariate models for prediction of impacts will be presented.
In civil engineering, clear regulations and standards, such as the European standard DIN EN 206 apply to ensure that the existing infrastructure is sufficiently resistant to a wide range of exposure conditions. Despite these regulations, in practice concrete structures often show severe damage during their service life. One of these damages is pitting corrosion of the reinforcement, which can be caused by chloride ingress into the structure. Therefore, determining the distribution and depth of chloride ingress is important in predicting the service life. LIBS provides an alternative method to conventional wet chemistry in civil engineering. Despite many advantages, the use of LIBS has been severely limited due to a lack of regulations. Together with project partners from research and industry, we are currently working on a leaflet that will regulate chloride analysis in civil engineering using LIBS. This year, an international round robin test was organized to evaluate the performance of LIBS for chloride analysis in cement pastes. No specifications were given for the experimental LIBS setup and data evaluation. The preliminary results are presented.
Al-Si alloys produced by Laser Powder Bed Fusion (L-PBF) techniques allow the fabrication of lightweight free-shape components. Due to the high cooling rates occurring during the building process, L-PBF AlSi10Mg alloys exhibit an ultra-fine microstructure that leads to superior mechanical properties in the as-built condition compared to conventional cast Al-Si materials. Nevertheless, L-PBF processing induces high thermal gradients, leading to deleterious residual stress. In order to relax detrimental residual stress and to increase the ductility, post-processing stress relief treatments are performed. The objective of the contribution is to investigate, under different heat treatment condition, the evolution of microstructure and residual stresses in view of optimizing the fatigue performance of the alloy. To this purpose various heat treatments in a range of temperatures between 265°C and 300°C for a duration between 15 minutes and 2 hours are performed.
In this work, we present our results achieved in several research activities for development of fiber optic dosimeters. The findings show that both the measurement of the radiation-induced attenuation (RIA) along the entire sensing fiber and the accom panying change in the refractive index of the fiber core can be used for distributed radiation monitoring in the kGy and MGy range, respectively. Depending on the fiber type and material the RIA shows varying response to dose rates, environmental temperatures and the wavelength of the laser source used.
Seit 1999 existiert das MIL-HDBK 1823, die us-amerikanische Leitfaden zur Erstellung einer Probability of Detection (POD; Fehlerdetektionswahrscheinlichkeit). Obwohl das Dokument als internationaler Stand der Technik angesehen wird, ist die allgemeine Anwendung in der ZfP-Praxis von einigen Nachteilen begleitet:
1. Die beschriebenen POD‘s bilden ausschließlich die Grundlagen-POD ab, jeweils mit nur einem Fehlerparameter und einem Signalparameter. Modernere Ansätze werden hier nicht adressiert.
2. Die aktuelle Version verzichtet fast vollständig auf konkrete mathematische Formulierungen.
3. Die Richtlinie richtet sich hauptsächlich an die militärische Luftfahrt.
4. Das Dokument ist nur in englischer Sprache verfügbar.
Mit Hilfe eines BMWi-Förderprojekts wird ein weiterführendes Regelwerk auf Basis der MIL-HDBK 1823 unter deutscher Federführung erarbeitet, welches die Anwendung der POD-Berechnung auf eine breitere Basis stellt und die oben genannten Nachteile der MIL-HDBK 1823 behebt.
Das vorgestellte Projekt „normPOD“ wird eine normative, branchenübergreifend einsetzbare Beschreibung des Vorgehens bei der Berechnung einer POD zur Zuverlässigkeitsbewertung zerstörungsfreier Prüfungen entwickeln. Hierbei wird Klarheit über unterschiedliche POD-Ansätze geschaffen und anhand praktischer Beispiele aus Maschinenbau und Bauwesen ein Leitfaden für den Praxiseinsatz erarbeitet.
Das Poster gibt einen Überblick über die geplanten Arbeiten innerhalb des Projekts und lädt die Beteiligten der DGZfP-Jahrestagung zur Diskussion ein, um eine breite Basis und Akzeptanz für die entwickelten Berechnungsverfahren zu schaffen, insbesondere in Hinblick auf ZfP 4.0 und Digitalisierung.