Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (122)
- Zeitschriftenartikel (111)
- Beitrag zu einem Tagungsband (74)
- Posterpräsentation (36)
- Sonstiges (14)
- Beitrag zu einem Sammelband (12)
- Buchkapitel (3)
- Dissertation (2)
- Handbuch (2)
- Forschungsbericht (1)
Sprache
- Englisch (377) (entfernen)
Schlagworte
- Corrosion (377) (entfernen)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (145)
- 7.6 Korrosion und Korrosionsschutz (142)
- 5 Werkstofftechnik (56)
- 5.1 Mikrostruktur Design und Degradation (52)
- 6 Materialchemie (34)
- 6.2 Material- und Oberflächentechnologien (26)
- 4 Material und Umwelt (25)
- 4.1 Biologische Materialschädigung und Referenzorganismen (20)
- 8 Zerstörungsfreie Prüfung (12)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (7)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (122)
While a lage amount of research on high entropy alloys is oriented towards mechanical properties and the microstructural improvement it is also necessary to keep an eye on the environment that potential application materials will be submitted to. The Co-Cr-Fe-Ni based high entropy family has shown great potential over the years of high entropy research and some candidate alloys are chosen for an insight into their corrosion behaviour. Several atmospheres are studied, i.e. O2, H2O, SO2 and a mix thereof in argon as well as synthetic air. Just as for classic alloys, the chromium is the most important element in terms of protection agains further corrosion. The addition of manganese, as in case of the “Cantor alloy” CrMnFeCoNi, overpasses Cr when it comes to oxygen affinity and thus counteracts the layer formation of Cr2O3. Even without Mn, a temperature chosen too high will also affect the formation of the chromium oxide layer and spall it off, annulling its protective potential. We can also observe how trace elements influence the layer formation. These effects and their mechanisms will be discussed for the alloys CrFeNi, CoCrNi, CrMnFeCoNi and variations of Al10Co25Cr8Fe15Ni36Ti6 using a combination of electron microscopy, thermodynamic calculations and x-ray diffraction.
The safe storage of radioactive material in nuclear waste repositories is a major task of our societies. The sealing function of such repositories is depending on the ability of the applied construction materials to form and maintain a geotechnical barrier with the surrounding rock. Corrosion of the construction material can lead to leakage of radioactive compounds and must therefore be avoided or minimized. Since concretes based on conventional Portland cement have not been found suitable in this context, alternative binders must be evaluated.
One such class of binders are hybrid cements, which are blends of low fractions of Portland cement or Portland clinker and high fractions of supplementary cementitious materials, such as blast furnace slag and fly ash, activated by an alkali salt. Besides a low heat of hydration and a sufficient early compressive strength [1], chemical similarities with ancient Roman concrete suggest an excellent durability in saline environments [2], which makes these cements potentially suitable for applications in nuclear waste repositories in evaporite rock, such as the Morsleben repository in Germany.
In the present study, two previously designed and characterized [3] hybrid cements, an alkali-activated slag/fly ash blend, and an OPC paste were studied regarding their resistance against corrosion in an aggressive saline solution. The saline solution was designed by the Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) [Association for Facility and Reactor Safety] as a reference representing a solution forming as the result of contact of surface water with evaporite rock. The cement pastes were exposed to the saline solution up to 70 days and characterized by X-ray diffraction, thermogravimetric analysis and spatially resolved X-ray fluorescence spectroscopy. In addition, thermodynamic modelling was performed to simulate the alterations of the phase assemblage with increasing exposure to the saline solution and, thus, provide indications on the long-term durability of the cement pastes.
The experimental results revealed a correlation between the Portland clinker content of the cements and the resistance of the cement pastes against attack by the saline solution. This outcome was related to the formation of portlandite when sufficient clinker was available, which maintained the pore solution pH at ~12.5, and thus prevented the dissolution of cementitious phases. Once portlandite was consumed, C-N-A-S-H and ettringite dissolved and released calcium, aluminium, and hydroxide ions in the solution, maintaining the pH at ~10. In this pH range, the formation Cl-AFm phases was observed. At lower pH values, i.e., extended exposure durations, gypsum was the major corrosion product. The pH-dependent dissolution and formation of phases lead to pronounced zonation in the exposed cement pastes. Thermodynamic modelling indicated that the dissolved silicon from C-N-A-S-H reacts with magnesium ions in the saline solution to form M-S-H, and that long-term exposure eventually leads to a material rich in amorphous silica and brucite.
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.
Due to the high corrosivity that are present in road tunnel structures, cleaning and maintenance work on stainless steel components in the tunnels is carried out at regular intervals in the tunnels, which means that parts of the lanes or the whole tunnel have to be temporarily closed. To reduce these traffic disruptions and maintenance costs, it is important to reduce the work that is needed for cleaning and maintenance of stainless steel components in road tunnels. One possibility is the identification and utilization of better suited alternatives to the commonly used austenitic stainless steels AISI 316L and AISI 316Ti. Thus, a field exposure study was carried out in different road tunnels throughout Germany to qualify different duplex and lean duplex stainless steels for tunnel constructions.
The proposed scientific poster gives an overview of results after the first three years of exposure in three different road tunnels. Samples of different stainless steels were placed in different areas of the tunnel – at lane height and at the ceiling. Some samples were exposed under sheltered conditions. Pit depths were evaluated on the free surface and in crevice areas after each year of exposure. The investigations show that duplex stainless steels have a comparable or even better corrosion resistance than austenitic steels in tunnel atmospheres
The offshore environment is inherently corrosive. Consequently, pits may nucleate on exposed steel surfaces. Corrosion pits can be a source of crack initiation when the structure is subject to fatigue loading. The criticality of a corrosion pit with respect to the structural integrity depends on its shape and size and can be quantified using a stress concentration factor (𝐾𝑡). In this work, a parametric 3D finite element model is developed to perform stress analysis of a pitted plate subjected to uniaxial tensile stress. The model is used for an extensive parameter study in which 𝐾𝑡 is determined for various pit configurations. It is demonstrated that each one of the geometrical parameters holds a substantial influence on the location of the Most Critical Region (MCR). It is shown that 𝐾𝑡 increases as the pit gets narrower. Pits with an elliptical mouth yield higher 𝐾𝑡 values when the angle between the load direction and the pit mouth major axis increases. Moreover, 𝐾𝑡 increases with the increase in the localized thickness loss which is more pronounced for relatively wider pits. Finally, a regression model is presented for estimating 𝐾𝑡 based on the geometric parameters of a pit.
Corrosion of reinforcement is one of the major reasons in questioning the sturdiness of building structures. The application of cathodic protection techniques plays a big role in controlling the corrosion process to ensure a longer service life of building structures. This systematic study compares the efficiency and durability of various discrete galvanic zinc anode systems available in the current market using different criteria for measuring efficiencies such as potential measurements, electrolyte resistance measurements and several polarization methods to determine the polarizability of the anodes. Results to validate the performance of long-time exposure of discrete zinc anodes in the concrete medium are already shown in 2021. Now the results of analyzing the phase boundary between mortar and anodes by using 3D computer tomography are shown, as also the field application at large-scale specimens where the potential distribution and the current were investigated.
Corrosion monitoring of reinforced concrete structures:The DGZfP specification B12 Collaboration
(2023)
Corrosion monitoring of reinforced or prestressed concrete structures has becomeincreasingly important in recent years. Areas of application include componentsthat are no longer accessible after completion or where potential fieldmeasurements cannot be carried out due to existing coatings. Corrosion monitoringcan also be used to monitor the progress of corrosion in corroding systems, e.g. to prove the success of repair measures according to repair principle 8 in accordancewith EN 1504‐9 or repair method 8.3 in accordance with the DIBt repair guideline.It also could be used to prove the functionality of cathodic corrosion protectionsystems in accordance with ISO 12696. Despite the increasing importance ofcorrosion monitoring, no guidelines orrecommendations existed until 2018. Thisgap was closed by the English version of specification B12,“Corrosion Monitoringof Reinforced and Prestressed Concrete Structures,”of the German Society for Non‐Destructive Testing, which was published in 2021. This article introducesspecification B12 by explaining the basicmeasurement principles and illustratingthe potential of corrosion monitoring in new and existing buildings.
With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research.