The paper presents a comparison between two different numerical modelling approaches aimed to simulate the in-plain behaviour of rammed earth walls, namely under axial, diagonal and cyclic shearcompression loading. In the first part of the study the mechanical characterisation of wallets tested under uniaxial compression and diagonal compression and walls tested under in-plane cyclic shear-compression loading is presented. The results were used to implement and validate the finite element simulations.
The numerical modelling of the rammed earth samples tested is then discussed in the second part. A non-linear constitutive law based on the total strain rotating crack model (TSRCM) was employed as implemented in the DIANA® software. The aim of the numerical analyses presented here is to simulate the behaviour of rammed earth under different inplane loading conditions. For the wallets, tests under static loading both macro- and micro-modelling
approaches were considered for the simulation of the experimental tests. For the walls subjected to cyclic loading only the micro-modelling approach was applied for the simulation of the experimental tests.
The respective FEM model was calibrated with the experimental results. The rammed earth layers were represented by continuum elements, the contact surfaces between layers by interface elements. This approach allowed assessing the influence of the apparent weakness of the interfaces between layers on the shear behaviour of rammed earth.
The goal of the numerical simulation of the cyclic tests was to establish the adequacy of common analytical methods (e. g. used for masonry) applied to the analysis of rammed earth. Rammed earth exhibits brittle characteristics similar to masonry materials and is used in geometrical typologies, such as walls, common in masonry construction.
The recent experience of Italian seismic events provided wide observational information about typical behaviour, damage patterns and intrinsic vulnerability of monumental buildings. Evidence indicates that historical constructions are by far the most vulnerable from the seismic point of view. As a consequence, they demand for the definition of urgent strategies for the protection of cultural heritage from seismic hazard. The main goal of an in-depth knowledge of the structure should help to avoid inadequate, unsuitable or dangerous rehabilitation operations, as well as to select non-invasive and reversible techniques for the best exploitation of material and technology features. The definition of reliable models and methods for seismic risk assessment of historical constructions is today a very important topic. Typical problems of masonry structures concern aspects like inherent structural lacks, material degradation, geotechnical problems, buckling behaviour of slender elements and dynamic loading vulnerability. Modelling the mechanical behaviour of masonry may play an important role, due to both inherent material complexity and great scatter in mechanical properties. Effective procedures for the identification of the structural parameters from static and dynamic testing are thus required. In particular, dynamic measurements may be very useful for the identification of mechanical properties and soil restraints and, consequently, for the calibration of advanced numerical finite element models. The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments, placed in the Campania region, were monitored by means of full-scale environmental vibration testing. Measured responses are then used for modal identification with a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out on the basis of a criterion which minimises a weighted error on modal properties. A satisfactory improvement in the determination of modal parameters is thus obtained, resulting in a close agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is finally performed based on nonlinear static analysis of the tower under multimodal distributions of lateral loads. Results from nonlinear analysis indicate the potential collapse mechanisms and evidence dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
UHPC-AAC/CLC composite panels with self-cleaning properties. Materials and production technology
(2016)
The aim of this study is to show the development of a façade composite panel combining either an autoclaved aerated concrete or a cellular lightweight concrete insulation layer with a box-type external ultra-high performance concrete (UHPC) supporting layer. The paper presents the materials characteristics of the different components and the production technology of the panel. The efficiency of surface modifications of the materials forming the external shell of the panel is reported. The activation of self-cleaning properties is described. The test results showed that the most efficient way to use the water-repellent agent is its application on the substrate before the concrete cast. Concerning the production technology, the preliminary studies showed more advantages of a twostep manufacturing procedure of the UHPC boxes than a one-step procedure.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.
This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches.
ln this paper a modelling approach is presented to reproduce the mechanical behaviour of sandwich panels via finite element analysis. Two types of panels were investigated in this scope of work. The first sandwich element was a textile reinforced concrete (TRC) panel with cellular lightweight concrete insulation and the second configuration was an ultra-high performances concrete (UHPC) panel with aerated autoclaved concrete insulation. The goal was to obtain a reliable numerical strategy that represents a reasonable compromise in terms of sufficient accuracy of the element characteristics and the computational costs. The results show the possibility of describing the composite action in a full sandwich panel. The achieved modelling approach will later be used for the optimization of TRC and UHPC panels in terms of minimizing the thickness, identifying the number and location of connectors, as well as evaluating varying anchorage Systems.
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
From the last decades the earth construction has a growing interest due to the high sustainability (low C02 emissions), thermal and acoustic performance, fire resistance and cost of the raw material (soil). In fact, earth construction can constitute a feasible solution for a more sustainable construction industry in developed countries. Nowadays the research areas on earthen construction focus from one side on the improvement of the materials for new buildings, on the other side on the Conservation of existing architectural heritage.
Historical earthen buildings are often damaged by static or dynamic loads in form of extensive cracking. All too often these cracks are insufficiently or inappropriately repaired, if at all, because of lack of knowledge and/or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. Cracks in earthen construction can be repaired by grouting to re-establish structural continuity, and can also be used to consolidate voids and gaps, or as a complement to other strengthening techniques such as the introduction of tie-rods.
In the framework of earthen materials for new constructions, the major drawback is that traditional earthen materials are typically considered as non-standard. The great variability and heterogeneity of the properties of the available soils, the lack of quality control in the manufacturing of the earthen materials and in the construction process can be pointed out as the main reasons behind this Situation. Furthermore, only few countries issued Standards and recommendations supporting earth construction, discouraging the design of earth construction by the technical community in countries where these documents are absent.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The intensive use of earth as a building material since ancient times resulted in an important and significant earthen built heritage currently existing worldwide spread. The rammed earth technique has a significant presence in this heritage, where it served to build from simple dwell-ings to fortresses. However, the high vulnerability of rammed earth constructions to decay agents and to seismic events puts in risk their further existence and the lives of millions of peo-ple. With respect to the seismic behaviour of rammed earth walls, the understanding and mod-elling of their shear behaviour are topics underdeveloped in the bibliography. Nevertheless, these topics are of extreme importance in the preservation and strengthening of rammed earth constructions. Therefore, this paper presents a numerical work aiming at modelling the non-linear behaviour of unstabilised rammed earth under shear loading, resorting to the finite ele-ments method (FEM). The models were used to simulate the behaviour of a set of rammed earth wallets tested under diagonal compression. Both macro- and micro-modelling approach-es were considered, where the objective of this last approach was to evaluate the influence of apparent weakness of the interfaces between layers on the shear behaviour. The total strain ro-tating crack model (TSCRM) was used to simulate the behaviour of the rammed earth material, while the Mohr-Coulomb failure criterion was used to simulate the behaviour of interfaces be-tween layers. Furthermore, uncertainties related to the definition of the input parameters re-quired performing a sensitivity analysis. The numerical models achieved good agreement with the experimental results and the compressive strength, the Poisson’s ratio, the tensile strength and the tensile fracture energy revealed to be the most important parameters in the analyses.