Alkali-silica reaction (ASR) is a serious Problem concerning the deterioration of concrete. This leads to significant maintenance and reconstruction costs for concrete infrastructures all over the world. The geographical regions, which play a major role in concrete deterioration, are for example coastal Areas or in general, areas with a high air humidity/salinity due to closeness of rivers or lakes.
These exemplary results show, the application of Raman spectroscopy establishes a valuable approach for characterizing the chemical and structural composition of ASR-products. The results prove the potential to trace the kind of reaction products, developing in dependence on the aggregate and to follow up its local alteration from origin of the gel.
The evaluation of cladding integrity is a major issue to be demonstrated in Germany for extended interim storage periods up to 100 years and subsequent transportation considering operational and accidental conditions with respect to reactor operation, cask drying and dry interim storage. The chemical reaction between the zirconium fuel cladding and the cooling water in water-cooled reactors produces hydrogen and zirconium oxide. Hydrogen diffuses into the cladding and precipitates as zirconium hydrides when the solubility limit is reached, preferably oriented in hoop direction. At high temperatures during vacuum drying procedures, the hydrides can dissolve. Over a succeeding period of slow cooling with existing hoop stress the hydrides precipitate again, but partly reoriented along the radial direction of the cladding. This change of microstructure in combination with a decreasing temperature (0.5...2 K/year) during (extended) interim storage and additional mechanical load by handling procedures or under accident conditions could lead to a potential cladding embrittlement and consequently increased failure probability. The current research project BRUZL (Fracture mechanical analysis of spent fuel claddings under long-term dry interim storage conditions) has been launched by BAM to investigate potential sudden brittle failure of spent fuel claddings at small deformation under long-term dry interim storage conditions and is presented.
In this joint project, standardized measurement methods for hybrid
mixtures are developed, which serve to determine safety
characteristics for explosion protection.
A hybrid mixture is a multi-phase System consisting of fuel gas or
vapor, as well as air and flammable dust. This combination can occur
for instance in drying processes or during heterogenous reaction
processes.
The successful off-line coupling of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for Separation of nanoparticles (NPs) with different surface coatings was shown.
Two mixtures of polystyrene nanoparticles (PS-NPs) with comparable core sizes (20 nm and 50 nm) but different coatings (no coating/carboxyl-coated) were studied. Separation in either method resulted in non-baseline resolved or non-separated peaks. In contrast, two-dimensional off-line coupling of AF4 and CE resulted in clearly separated regions in their 2 D plots and can obviouly improve separation resolution.
Polymeric membranes represent a low-cost, energy efficient solution for gas separation. Recently polymers of intrinsic microporosity (PIMs) have emerged as prestigious membrane materials featuring a large concentration of pores smaller than 1 nm, a BET surface area larger than 700 m2/g and high gas permeability and selectivity. Unusual chain structure combining rigid segments with sites of contortion gives rise to the intrinsic microporosity. However, this novel class of glassy polymers are prone to pronounced physical aging. The initial microporous structures approach a denser state via local small scale fluctuataions, leading to a dramatic reduction in the gas permeabilities. For the first time, dielectric relaxation spectroscopy with state-of-the-art high-resolution analyzers was employed to investigate three representative PIMs with a systematic change in chain rigidity: PIM-EA-TB 〉 PIM-1 〉 PIM-MDPH-TB. The molecular mobility, the charge transport and their response upon heating (aging) in the polymers were measured in a broad temperature range through isothermal frequency scans during different heating / cooling cycles. Multiple dielectric processes following Arrhenius behavior were observed for the investigated polymers. Local fluctuations, Maxwell-Wagner-Sillars (MWS) polarization and structural relaxation phenomena were discussed and attempted to be correlated with the structural features of PIMs. Moreover, all PIMs showed conductivity in the glassy state. The significant increase in the conductivity with increasing temperature far below the glass transition temperature of PIMs is explained in terms of the loosely packed microporous structure and the formation of local intermolecular agglomerates due to interaction of π-electrons in aromatic moieties of the polymer backbone.
The elemental analysis of seawater is often critical to the understanding of marine chemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdown spectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a great potential for in-situ elemental analysis of seawater. In practice, it is crucial to create a compact, low cost and power saving instrument for the long-term deep-sea observation. A recently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidate as it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHz can provide a considerable throughput for LIBS analysis. However, the DPSS lasers operate at moderate pulse energies, usually less than one mJ, which cannot sustain stable breakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such a μJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. The phase interface and mass flow generated by the near-field ultrasound can greatly reduce the breakdown threshold and enhance element-specific emissions. Meanwhile, the high repetition-rate pulses can also improve the breakdown probability and generate unique emission lines originated from the water molecule. We further demonstrate that the high repetition-rate DPSS laser combined with the Echelle spectrometer can provide effective quantitative analysis for metal elements in bulk water.
The elemental analysis of seawater is often critical to the understanding of marinechemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdownspectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a greatpotential for in-situ elemental analysis of seawater. In practice, it is crucial to create acompact, low cost and power saving instrument for the long-term deep-sea observation. Arecently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidateas it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHzcan provide a considerable throughput for LIBS analysis. However, the DPSS lasers operateat moderate pulse energies, usually less than one mJ, which cannot sustain stablebreakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such aμJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. Thephase interface and mass flow generated by the near-field ultrasound can greatly reduce thebreakdown threshold and enhance element-specific emissions. Meanwhile, the highrepetition-rate pulses can also improve the breakdown probability and generate uniqueemission lines originated from the water molecule. We further demonstrate that the highrepetition-rate DPSS laser combined with the Echelle spectrometer can provide effectivequantitative analysis for metal elements in bulk water.
Non-linear optical emitters are promising materials for energy applications and biotechnologies. Solid-state multi-band emitters like lanthanide doped up-conversion nanoparticles (UCNPs) show excellent photostability, are excitable in the near infrared (NIR), and show emission bands from the UV to SWIR spectral regions. The optical properties of these materials strongly depend on the excitation power density, i.e., the number of photons absorbed per time interval. The upconversion (ΦUC) and downshifting quantum efficiencies (ΦDS) of these materials, the excitation power dependent population, and the deactivation dynamics are influenced by nanoparticle architecture, doping concentration, and the microenvironment. We studied the fundamental changes of the luminescence properties of ß-NaYF4 UCNPs doped with Yb3+ and Er3+ depending on size, different surroundings such as aqueous and organic media, and different surface chemistries. We obtained further insights into shelling procedures, FRET optimization, influence of doping concentration, and advantages of different sensitizer ions.
By means of a small-scale truss bridge, the ability of the Measurement- and Model-based Structural Analysis to detect and localize damage was examined. Although there was no noteworthy difficulty in detecting damage, it turned out that damage localization responds sensitively to systematic influences, i.e. non-modelled properties of the mechanical model. Therefore, another experiment is being conducted to re-examine the Measurement- and Model-based Structural Analysis. For this purpose, the bending test is carried out as it has been already theoretically respectively numerically discussed. In this attempt, the systematic influences such as residual stress are kept as low as possible.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.
The Motivation of RASEM (Robot-assisted Environmental Monitoring):
Monitoring of the air quality in industrial environments is inevitable to meet safety Standards.
Because of economic and practical reasons, measurements are carried out sparsely in terms of time and space.
Newest developments on the field of low cost sensor technology enable cost efficient long term monitoring of gases and dust
Quality Aspects of Additively Manufactured Medical Implants - Defect Detection in Lattice Parts
(2019)
Additive Manufacturing technologies are developing fast to enable a rapid and flexible production of parts. Tailoring products to individual needs is a big advantage of this technology, which makes it of special interest for the medical device industry and the direct manufacturing of final products. Due to the fast development, standards to assure reliability of the AM process and quality of the printed products are often lacking. The EU project Metrology for Additively Manufactured Medical Implants (MetAMMI) is aiming to fill this gap by investigating alternative and cost efficient non-destructive measurement methods.
The assessment of high cycle fatigue in additive manufactured (AM) components is a challenge due to complex microstructure, anisotropic material behavior, residual stresses and porosity / lack-of-fusion defects. Due to the statistical distribution of defects, a high scatter band of S-N-curves is expected. The fracture mechanics-based fatigue assessment of additive manufactured components must consider the propagation of short cracks emanating from defects.
In this work, the fatigue crack propagation resistance in the short and large crack regimes of additive and conventionally manufactured AISI 316L stainless steel is examined experimentally based on the cyclic R-curve. However, remaining residual stresses in the AM specimen lead to unexpected and dramatic crack-growth during the pre-cracking procedure.
3D coherence scanning interferometry (CSI) is anoptical, non-contact and rapide measurement technique using a defined bandwidth of white light at normal incidence. White light interference microscopy (WLIM) providest here-dimensional surface topometry data up to a resolution of 0.4 µm lateral and 0.1 nm vertical. Three operating modi, surface, films and advanced films, enable measurements of step heights, roughness, wear volume, cone angle, surface pattern and layer thickness. Traceability to SI system is ensured by certified standards (PTB/NIST) within a DAkkS DIN EN ISO/IEC 17025:2018 accredited lab.
Elemental impurities (EI) in medicinal products for human use are limited according to ICH guideline Q3D, which is in force since December 2017 in Europe and US.
As a consequenceconsequence, the relevant texts of the European Pharmacopoeia (Ph. Eur.) and the United States Pharmacopeia (USP) have been modified to reflect and complement ICH Q3D, providing details on the analytical methods to be used. In those chapters (Ph. Eur. 2.4.20., USP <233>), it is stated that for the quantification of elemental impurities, certified reference materials (CRM) from a national metrology institute (NMI) or reference materials that are traceable to the CRM of an NMI should be used.
The Ph. Eur. has so far implemented elemental impurity standards of this type for the four most important elemental impurities i.e. those corresponding to ICH Q3D Class 1: lead, cadmium, mercury and arsenic.
The poster provides details on the development of those four reference standards, which was undertaken in partnership with a major institute accredited CRM producer (JRC, European Commission), and a national metrology institute (BAM and PTB, Germany), and a Designated Institute and accredited CRM producer (BAM, Germany). The reference standards were established and characterised according to rigorous metrological principles and are supplied with extended supporting information as required for the intended use.
After successful completion of the project, the four reference standards have been added to the Ph.Eur. catalogue and are in distribution. It is expected that another three elemental impurity standards will be implemented and made available to users within the next three years.
Glass strength and fatigue is limited by surface cracks. As subcritical crack growth (SCCG) is governed by ambient humidity, stress corrosion at the crack tip is widely accepted to be the underlying mechanism. However, as water is known to have decisive effect on glass properties and can rapidly enter the crack tip near glass region, SCCG could be affected by such water related phenomena. We tried to mimic these effects studying water dissolution and speciation, mechanical properties, and SCCG in water-bearing glasses. For this purpose, glasses up to 8 wt% water have been prepared by means of high-pressure melting of glass powder - water mixtures.
As part of this effort, SCCG in dry and hydrous commercial micros¬cope slide glass (CW = 6 wt%) was studied in double cantilever beam (DCB) geometry and sub-Tg relaxation was measured by Dynamic Mechanical Analysis (DMA).
For SCCG in ambient air (24% r.h.), SCCG was promoted by the presence of 6wt% bulk water with respect to the dry glass. On the other hand, stress intensity values, KI, required to cause slow crack growth (v < 10-6 ms-1) resemble literature findings for float glass of similar composition in liquid water, which might represent the maximum possible promoting effect of ambient water on SCCG.
For SCCG in vacuum (10-3 mbar), dissolved bulk water causes even more pronounced effects. Most strikingly, it strongly decreases the slope of the log v(KI)-curve, which is a measure of dissipated energy during fracture. A strong increase of sub-Tg relaxation with increasing water content was confirmed by DMA. As a consequence, slow crack growth occurs at KI values as measured in the dry glass whereas fast crack growth occurs at much larger KI than that of the dry glass. Kinks and shoulders shown by the inert log v(KI)-curve indicate that bulk water does not simply affect bulk mechanical properties.
Water as side effect of reinforcing boehmite filler Local changes in anhydride cured epoxy resin
(2019)
Nanocomposites offer wide opportunities for lightweight constructions and enable reduction of weight and volume. Beside macroscopic toughening nanoparticle reinforced polymers show a soft interface around boehmite (AlOOH) filler nanoparticles. A related strong interaction between boehmite and the anhydride cured resin system is widely suspected in literature but not determined by structural Analysis. Determination of the molecular structure is important to allow simulations approaching the real system and predict future reinforcing effects.
DRIFT (diffuse refletance infrared fourier transformed) spectra of the boehmite reinforced anhydride cured epoxy show significant changes in the molecular structure compared to the neat polymer. Further investigations of the interactions between the single components of the resin system and the boehmite filler pointed out reactions between released water released from the boehmite filler and the anhydride hardener or amine accelerator. This leads to the discussion of competing polymerisation mechanisms that highly influence the polymer properties. Ongoing experiments and literature research approve that this impact of water is able to locally change the stoichiometrie, alter the curing mechanism or support an inhomogeneous crosslink density.
New Focus On Boehmite-Reinforced Nanocomposites Molecular Approach With Advanced FTIR-Techniques
(2019)
By FTIR-study it was possible to proof a chemical reaction between boehmite and the hardener of anhydride cured epoxy resins. Future studies can assume that the chemical environment of the resin system is changed in the surrounding of boehmite nanoparticles. This highly affects especially localized properties.
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pHsensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
In summary, by combining the NIR-emissive [Cr(ddpd)2][BPh4]3 complex CrBPh4 with its extremely large energy gap between the longest wavelength absorption and emission maxima with a pH-responsive fluorescein derivative (FITC) and an inert reference dye like Nile Red (NR) and 5,10,15,20tetrakis(pentafluorophenyl) porphyrin (TFPP), we developed nanosensors for simultaneously sensing temperature, O2 partial pressure, and pH. These novel TOP nanosensors (temperature, oxygen, pH) cover the biologically and physiologically relevant concentration ranges of these parameters/analytes with single wavelength excitation in PBS buffer and in a cell culture medium containing bovine serum albumin (BSA). The response of both nanosensors to all parameters is fully reversible and only minimally affected by the presence of BSA, the most common serum albumin. Moreover, comparative studies with nanosensors containing only a single type of stimuli-responsive molecule and with the respective molecular systems revealed that the different sensor components do not interfere with each other. Future research will include the testing of these nanosensors in cellular uptake studies and, after surface modification with targeted bioligands, eventually in in vivo experiments as previously done by some of us with other polystyrene nanoparticle reporters and nanosensors.46,47 Moreover, this concept of multianalyte sensing will be expanded to nanosensors derived from differently sized premanufactured biocompatible polymer particles and different stimuli-responsive dyes like fluorescent indicators for biologically and bioanalytically relevant metal ions.
Working towards a comprehensive understanding of introduction pathways, number, and fate of micro¬plastics in the environment, suitable analytical methods are a precondition. Micro-spectroscopic methods are probably the most widely used techniques. Besides their ability to measure single spectra of a particle or fiber, most modern FTIR- and Raman microscopes are also capable of two-dimensional imaging. This is very appealing to microplastics research because it allows to simultaneously characterize the analytes chemically as well as their size (distribution) and shape.
Two-dimensional imaging on extensive sample areas with FTIR-micros¬copes is facilitated by focal plane array (FPA) detectors resulting in large data sets comprised of up to several million spectra. With numbers too large for manual inspection of each individual spectrum, automated data evaluation is inevitable. Identifying different polymers based on the comparison with known reference spectra (library search) has proven to be a suitable approach. For that purpose, FTIR-spectra of common plastics can be collected to create an individual reference library.
To Supplement this ‘targeted analysis’, looking for known substances via library search, an exploratory approach was tested. Principal component analysis (PCA) proved to be a helpful tool to drastically reduce the size of the data set while maintaining the significant information. Subsequently, cluster analysis was used to find groups of similar spectra. Spectra found in different clusters could be assigned to different polymer types. The variation observed within clusters gives a hint on chemical variability of microplastics of the same polymer found in the sample. Spectra labeled according to the respective cluster/polymer type were used to build a classification model which allowed to quickly predict the polymer type based on the FTIR spectrum. Classification was tested on a second, independent data set and results were compared to the spectral library search procedure.
In this study, we developed a new immunoprecipitation method based on protein-coated nanodiamonds. Performing SDS-PAGE and using the SDS-PAGE buffer as an eluent showed that CER could be successfully enriched from human serum. Based on the copper determination with ICP-MS, the amount of bound CER on the nanodiamonds can be calculated. We could show the fulfilled mass balance of bound CER and CER in the supernatant after incubation with a known amount of CER. For isotope ratio analysis this method can be applied to compare ratios of the total copper content in human serum to copper ratios from CER enrichment.
In civil engineering, the investigation of existing infrastructure is of major importance for maintaining and ensuring stability of the structures. To ensure durability, uniform regulations and standards apply e.g. the European standard EN 206-1. In some countries, the EN-standard is supplemented by additional standards, as in Germany with DIN 1045-2. Here, specific application rules are described, e.g. for the cement type, to ensure the resistant to different exposures. Therefore, the knowledge of the materials originally used is important in assessing the condition of existing concrete structure. Unfortunately, these are often unknown and must be determined retrospectively. Therefore, we present the application of the laser-induced breakdown spectroscopy to distinguish between different types of cement. Spectral information’s are used to build a classification model. First, the accuracy of the classification is analyzed on ten pure laboratory cement samples. To investigate possible sources of error, the model was then applied to cement samples with different moisture content. The study shows that LIBS is a promising tool for distinguishing between cement types. For further industrial application, however, factors influencing the LIBS signal must be included to ensure a robust model.
The advantages of treating prefabricated components made of Ultra-High-Performance Concrete (UCPC) at 90 °C are largely recognized, while hydrothermal treatment at 185 °C and the corresponding saturation pressure of 1.1 MPa, in contrast, is not applied in building practice so far and was studied only by a few researchers.
In the research presented, the parameters pre-storage-time before treatment and dwell time in the autoclave were systematically varied. The results illustrate in which way compressive strength increases with the duration of treatment. Already samples which were only heated up and immediately cooled down show an increase in strength compared to the 28-day reference of about 10 %. After 20 h the maximum increase of about 25 % is reached. Interestingly the compressive strength of samples treated very long hardly decreases. It can be therefore concluded that for the composition investigated the achievable mechanical strength is not severely sensitive regarding the duration of the treatment.
Also, pre-storage times before autoclaving longer than 0.5 days showed no significant impact on strength development. The phase composition measured by XRD exhibits significant changes compared to the reference. The amount of ettringite and portlandite have vanished, the cement clinker phases are substantially decreased and hydroxylellestadite and hydrogarnet are formed as new phases. The increase in strength can be assigned to an improved pozzolanic and hydraulic reaction. Contradictory to literature, there was found no obermorite, a mineral which is known to be susceptible for disintegration at Long autoclaving duration. This explains why no significant strength loss appeared.
Herein, we present the development of a gas chromatographic method for Determination of warfarin, its TPs, and selected metabolites.
TPs were formed by applying UV-irradiation, ozonation, and an electrochemical cell coupled to mass spectrometry to mimic the oxidative phase I metabolism. The further aim is to use this method for detection and quantification under environmentally relevant conditions, as well as, toxicological assessment.
Das Therapeutikum Warfarin ist bis heute der bekannteste Vertreter der antikoagulanten Rodentizide. In dieser Arbeit wurden Phase I Metabolite mittels einer elektrochemischen Durchflusszelle simuliert und analysiert. Weitere Transformations- und Abbauprozesse wurde durch UV-Bestrahlung und Ozonung generiert, gaschromatographisch getrennt und miteinander verglichen.
Despite abundant evidence of the occurrence of microplastics (MP) – these are particles smaller 5 mm – in aquatic environments, little is known about the accumulation of plastic in terrestrial environments, especially in soils.
Possible major input pathways could be the use of plastic mulching, the use of compost, sewage sludge or residues from biogas facilities as fertilizers, as well as littering in urban areas. To estimate the MP pollution, the development of reliable, fast methods for sampling, sample preparation, and detection is needed. The obtained data must be representative of the sampled environmental compartment and measurements from different environmental compartments must be comparable. A first breakthrough is an application of ThermoExtractionDesorption-Gas Chromatography-MassSpectrometry (TED-GC-MS) for the detection of MP, including tire abrasives. This method allows the determination of mass content within a few hours and only a minimum of sample preparation for samples from aquatic environments is needed.
However, in contrast to filtrate samples from aquatic environments, sediment or soil samples need an enrichment of MP. Whereas MP concentration from marine sediments can be obtained by floatation and density Separation techniques using NaCl solutions, the extraction or separation from soils proves to be more difficult, as plastic particles are often part of organo-mineral aggregates within the soil matrix.
The aim of this study is the development of a practicable processing guideline for representatively taken soil samples in order to concentrate microplastics, without complex and time-consuming treatment steps. Dispersants or detergents can be applied to decompose the soil matrix, but each preparation step carries the risk of crosscontamination of the sample and prolongs the preparation procedure.
For this reason, we choose ZnCl2-solution with a density of 1.7 g/cm3, which include the densities of relevant MP types (0.9-1.7 g/cm3). It was tested to achieve both, disaggregation and separation as it decomposes organic material and dissolves carbonates. Also, ZnCl2 is inert to the precipitation of undesirable salts and Carbonates during the process of density separation, as polytungstate solution does. ZnCl2 can be reused after stepwise filtering (7 µm, 1.5 µm, 0.7 µm). Thus, disposal costs can be reduced. Efficiency and reproducibility of the sample preparation as well as the degradation behavior of MP under the present conditions were demonstrated with model samples.
Real sampling campaigns were conducted at several agricultural sites and floodplains in south-west Germany. The sampling was performed according to practice for soil sampling, using adequate sampling strategies (pattern of sampling, number of field samples, homogenization, etc). The lab sample was fractioned into three size classes (5-100 µm, 100-1000 µm, and 1-5 mm). The identification and determination of mass fraction were done using TED-GC-MS.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144 and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. We could achieve for the first time measurement uncertainties for isotope amount ratios close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level (2SD). In addition, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multi-collector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ to 0.7 ‰.
With these isotope reference materials, it is possible to establish SI-traceability for magnesium delta measurements. To realize this, we organized a second study within which five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for δ26/24Mg determinations (2SD). Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.
In isotope ratio applications metrological principles such as measurement uncertainty and SI traceability often are not considered or realized. This is also well-documented by the traceability exception related to delta scale isotope ratio measurements CCQM requested from the CIPM. Generally, delta scale isotope ratio measurements can be performed on a precision level that is significantly lower than the uncertainty level of isotope amount ratio measurements. In the case of magnesium, we demonstrated for the first time that isotope amount ratios can be measured with uncertainties close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of NIST SRM 980 became apparent and NIST SRM 980 was replaced by an intermediate artefact, DSM3. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144, and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. Thus, these materials qualified to establish SI-traceability for magnesium delta measurements. In a second study five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1 ‰ for δ26/24Mg determinations. Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.
Specific co-fertilization of nutrients can enhance their plant-availability and thus the yield of plants. To investigate this effect, we performed a pot experiment with three different P-fertilizers and ammonium nitrate sulfate as a co-fertilizer, without and with a nitrification inhibitor (NI), and analyzed the form of nitrogen (N) in the soil via novel X-ray spectroscopic method. The application of NI with the N fertilizer led to a higher dry matter yield of maize. Novel N K-edge micro-X-ray absorption near-edge structure (micro-XANES) spectroscopy identified that the application of a NI promotes the temporary formation of a non-exchangeable N in detectable hot-spots in the soil. The subsequent slow release and prolonged availability of N during plant growth leads to higher yield. It can be concluded that NIs lead to a temporary fixation of ammonium-N in a pool that can be accessed by plant roots. Those types of available nutrient pools meet the idea of so-called “next generation fertilizers” as plants have access to nutrients according to their current demand.
Phosphorus (P) fertilizers from secondary resources became increasingly important in the last years. However, these novel P-fertilizer can also contain toxic pollutants e.g. chromium (Cr) in the hexavalent state (Cr(VI)), which is regulated with low limit values in agricultural products (German fertilizer ordinance limit: 2 mg/kg Cr(VI)). The determination of Cr(VI) in these novel fertilizer matrices can be hampered by redox processes that lead to false results with the standard wet chemical extraction method (German norm DIN EN 15192). Therefore, we analyzed Cr(VI) in various P-fertilizers with the DGT technique. DGT devices equipped with a APA (polyacrylamide) diffusion layer and Cr(VI) selective N-methyl-D-glucamine (NMDG) binding layer were used for the study. After a 24 h conditioning period of the fertilizer at 60% of the water holding capacity (WHC), the fertilizers were brought to 100% WHC, transferred onto the DGT devices and deployed for 24 h at 25°C. The extraction of Cr from the DGT binding layer was carried out with 1 M HNO3 for 24 h. The Cr-concentrations of the extract were determined by means of ICP-MS. We found a good correlation between the standard wet chemical extraction and the DGT method for the whole range of P-fertilizers. However, partly soluble Cr(VI) compounds cannot be detected in full extent by the DGT method that is best suited for mobile Cr(VI). Furthermore, Cr K-edge XANES spectroscopy showed that the Cr(VI)-selective DGT binding layer also adsorbs mobile Cr(III) compounds from acid treatment of phosphates which can therefore cause an overestimation of Cr(VI). The DGT method was very sensitive and in most cases selective for the analysis of Cr(VI) in P-fertilizers made from recycled materials. However, the results of certain types of P-fertilizers containing mobile Cr(III) or partly immobile Cr(VI) show that still some optimization of the method is required to avoid over- or underestimation of Cr(VI).
Phosphorus (P) resource availability is declining and the efficiency of applied nutrients in agricultural soils is becoming increasingly important. This is especially true for P-fertilizers from recycled materials which often have a lower plant-availability compared to commercial P-fertilizers but are expected to play an increasingly important role into the future (Kratz et al. 2019). One promising way to increase the plant-availability of the fertilizer P is a co-fertilization with specific nitrogen (N) forms which can enhance the P uptake and make P-fertilizers from recycled material more competitive to commercial phosphate rock-based P-fertilizers (Rahmatullah et al. 2006; Vogel et al. 2018). To investigate this effect, we performed a pot experiment with three different P-fertilizers (sewage sludge-based, phosphate rock and triple superphosphate) and ammonium nitrate sulfate as a co-fertilizer, without and with a nitrification inhibitor (NI), and analyzed the form of N and P in soil via a suite of chemical and novel X-ray spectroscopic methods. The application of NI with the P and N fertilizers led to a higher dry matter yield and a higher P uptake of maize. Novel N K-edge micro-X-ray absorption near-edge structure (micro-XANES) spectroscopy identified that the application of a NI promotes the temporary formation of a non-exchangeable N in detectable hot-spots in the soil. The subsequent slow release and prolonged availability of N during plant growth leads to higher yield and nutrient uptake. It can be concluded that NIs lead to a temporary fixation of ammonium-N in a pool that can be accessed by plant roots. Those types of available nutrient pools meet the idea of so-called “next generation fertilizers” as plants have access to nutrients according to their current demand.
Acoustic levitators generate acoustic standing waves between a transducer and a concave reflector. These acoustic waves are separated by multiple integer numbers of half wavelengths. Thus, acoustic levitation is the effect that a small volume (5 nL-10 μL) of sample can be levitated in a contact-free manner. Until now, levitation in analytical chemistry has primarily been associated with optical techniques such as Raman, X-Ray or UV/Vis spectroscopy. Less common applications are combinations of acoustic levitation with mass spectrometry. One reason for this being that the acoustic field surrounding the droplet effectively shields the sample, thus making it inaccessible to most ambient ionization techniques. Any effective investigation of acoustically-levitated droplets therefore requires the physical removal of some of the sample from the confine region of the acoustic trap before analysis.
The development of new strategies for the sensing of phosphorylated and carboxylate-containing biomolecules such as phosphorylated tyrosine and histidine or sialic acid is currently of strong interest because those molecules are often involved in cancerous processes. Molecularly Imprinted Polymers (MIPs) are formed through the polymerization of a set of functional monomers and cross-linkers in the presence of a target molecule or an analogue of it. The target molecule is incorporated into the polymer network due to non-covalent interactions established with one or more functional monomers. Because those interactions are weak, the target molecule can be desorbed a posteriori from the polymer matrix, leaving imprinted cavities of complementary size, shape and electronic nature. Resembling the antigen-binding site of an antibody, MIPs can then be highly selective towards the target molecule. Besides these features, our approach involves also the use of functional fluorescent monomers which undergo fluorescence changes upon binding of the target molecule. This allows us to investigate the sensing process using fluorescence as a highly sensitive read-out. To that aim we present here the use of silica particles which contain a MIP shell formed by thiourea or guanidinium functionalized dyes for the recognition of phosphorylated and carboxylate-containing molecules of biological relevance in polar, protic solvents.
One of the most important goals in civil engineering is to guaranty the safety of constructions. National standards prescribe a required failure probability in the order of 10-6 (e.g. DIN EN 199:2010-12). The estimation of these failure probabilities is the key point of structural reliability analysis. Generally, it is not possible to compute the failure probability analytically. Therefore, simulation-based methods as well as methods based on surrogate modelling or response surface methods have been developed. Nevertheless, these methods still require a few thousand evaluations of the structure, usually with finite element (FE) simulations, making reliability analysis computationally expensive for relevant applications.
The aim of this contribution is to increase the efficiency of structural reliability analysis by using the advantages of model reduction techniques. Model reduction is a popular concept to decrease the computational effort of complex numerical simulations while maintaining a reasonable accuracy. Coupling a reduced model with an efficient variance reducing sampling algorithm significantly reduces the computational cost of the reliability analysis without a relevant loss of accuracy.
The Influence of the Temperature Gradient on the Distribution of Residual Stresses in AM AISI 316L
(2019)
Steep temperature gradients and solidification shrinkage are the main contributors to the formation of residual stresses in additively manufactured metallic parts produced by laser beam melting. The aim of this work was to determine the influence of the temperature gradient.
Diffraction results show a similar pattern for both specimens, indicating the shrinkage to be more dominant for the distribution of residual stresses than the temperature gradient. Thermography results imply that a higher energy input result in higher compressive residual stresses in the bulk.
µCT is used to validate the capability of online monitoring for in-situ detection of defects during the L-PBF build process, which is a focus of the TF project ProMoAM.
Our first experiments show that online monitoring using thermography and optical tomography cameras are able to detect defects in the built part. But further research is needed to understand root cause of the correlation.
Fiber reinforced polymers (FRPs) are a well established material in lightweight applications, e.g. in automotive, aerospace or wind energy. The FRP components are subjected to multiaxial mechanical as well as hygrothermal loads. Common operation temperatures are in the range of 213 K and 373 K (-60 °C and 100 °C) at a relative humidity of 10% to 90%. In spacecraft applications, the environmental conditions are even more extreme. However, the correlation between multiaxial mechanical loading and harsh environment conditions have to-date not been investigated in detail. The project aims to investigate the fatigue behavior of FRPs dependent on multiaxial mechanical loading, temperature, and humidity. Extensive experimental testing is performed on flat plate and cylindrical tube specimens, accompanied by numerical and analytical calculations.
19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used.
The church of Koszewko (Poland) is a brick building edified in the 15th century built on cobblestone foundations. There are five windows in the sanctuary. Three of them enclose heraldic panels from the Küssow’s family from the 15th century which are surrounded with Goethe glass from the 18th century to complete the windows. The colored heraldic panels are strongly damaged and corroded with massive paint layer losses, glass- and leadbreakages. Those medieval glass fragments have been shortly discovered and are of particular interest for Poland since only few medieval glazing have been conserved.
The damages as well as the glass compositions have been investigated with ESEM/EDX. Two categories of medieval glass compositions have been identified. The blue glass is particularly sensible to corrosion because of his high content in K2O. The colorless and the red glass samples belong to a stable glass type. Due to the thickness of the gel layer, it is easy to see that the degradation is strongly proceeded. The protection of those medieval stained-glass panels is absolute necessary.
The medieval panels have been restored and surrounded from a copper frame. Then they have been fixed on the wood frame in the church. The exterior glazing has been closed with a panel of Goethe glass. The gap between the Goethe- and the medieval glass is about 3 cm. The Goethe glass panel has been stabilized with a film based on polyester to protect the medieval glasses against any damages. In this way, a low cost protective glazing has been installed for a long-term conservation of each medieval stained-glass panels. The climate measurements over the period of one year on the restored windows are in process. The temperature and the relative humidity are recorded in the church interior, in the gap between the original and the Goethe glass and outdoors.
Coating materials are nowadays often required to deliver not only sufficient barrier performance and suited optical appearance but a broad range of other functional properties. The incorporation of inorganic nanoparticles (NPs) is known to improve many key characteristics and provide new functionalities in polymer materials. Presented work aims to prepare and characterize an organic-inorganic coating material designed to bring together advantageous properties of hybrid materials and reinforcement effect delivered from the inorganic NPs embedment.
Siloxane-based hybrid resins hold great advantages as coating materials as their properties can be tuned between those of polymers and those of glasses, thus, the compositions with superior thermal and mechanical properties can be achieved. We used Cycloaliphatic Epoxy Oligosiloxane (CEOS) resin as a polymeric matrix where the network formation was achieved by UV induced cationic polymerisation. Boehmite Alumina (BA) nanoparticles were added to CEOS resin as a reinforcing agent and resultant material was processed into films either by bar-coating or by spin-coating depending on further characterization procedure. Two different types of BA NPs, hydrophilic and organophilic, were used in order to assess the impact of particles surface on the resin characteristics. CEOS synthesis by condensation reaction was confirmed using 13C and 29Si NMR. Changes in CEOS photocuring process, resulting from particles incorporation, were monitored by real-time IR spectroscopy. At the same time, the thermal behaviour was evaluated by DSC and TGA methods. Morphology of the coatings was investigated by means of SEM operated in transmission mode.
It was observed that BA presence increased the epoxy conversion degree and glass transition temperature. Material formulations providing best film characteristics were determined with regard to the particle type and loading. Compared to the hydrophilic nanoparticles, organophilic BA NPs yield superior overall performance of the foils.
The simultaneous detection of different analytes has gained increasing importance in recent years, especially in the fields of environmental and health monitoring. Particularly suitable formats for multiplexing are bead-based assays. The beads employed need to fulfil size and density requirements important for instance for flow cytometry and shall exhibit an as high as possible surface area for anchoring capture probes to allow for low limits of detection. Core/shell particles are ideally suited in this sense because of their modularity in design and adaptability for various (bio)analytical assays. Here, polystyrene particles coated with different kinds of mesoporous silica shells are presented, possessing distinctly higher surface areas in comparison to non-porous core/shell particles. Different factors such as pH and amount and type of mediator salt used during shell preparation were evaluated with shell inspection by scanning/transmission scanning electron microscopy (SEM/tSEM) being key to architecture control of the monodisperse particles.
For a cytometric model assay, the optimized core/shell particles were functionalized with capture oligonucleotides for DNA detection. After covalent attachment of single-stranded DNA to the silane-modified silica surface, a hybridisation assay using labelled t-DNA complementary strands was carried out to demonstrate particle performance, showing how tailoring of the shell’s surface area controls sensitivity and dynamic range of the assay. Finally, a multiplex assay for the determination of DNA from different human papilloma virus (HPV) lines was developed. Using our optimized particles, we were able to detect down to 10 amolμl‒1, which is an improvement of one order of magnitude compared to assays using non-porous particles reported in the literature. In addition, multiplexed detection could successfully be demonstrated.
In this work, the structural integrity of LBM fabricated IN625 small cylinders (d = 1 mm, h = 6 mm) was investigated regarding the porosity and the surface roughness by means of computed tomography. The measurements were carried out on a GE v|tome|x L 300/180 with a reconstructed voxel size of 2 µm. The pores were analyzed for size, shape and spatial distribution. The correlation between compactness C and spatial distribution showed that elongated pores (C < 0.2) appear exclusively within a distance of 80 µm to the sample surface. The reconstructed surface was digitally meshed and unwrapped to evaluate the mean roughness Ra. Since the gravity correlates linearly with the sine of the build angle, the influence of gravity on porosity and surface roughness was determined.
TIG welding process was monitored using LIBS for the in situ measurement of chemical compositions in austenitic stainless steels. This research aims to prototype a real-time chemical composition analysis system for welding applications and prove the feasibility of such a quality control loop.
The chemical compositions of the weld pool, considering the welding metallurgy, is the most critical parameter for any occurring weld defects, e.g. hot cracking. Hence, controlling the weld pool chemical composition allows governing of the weld pool solidification behavior by monitoring and adjusting the respective welding parameters, e.g. welding current.
LIBS measurements were conducted during a TIG-welding process. The effect of the welding plasma on the LIBS signal was thoroughly investigated by varying various LIBS settings, e.g. delay and exposure time. Quantification of the main alloying elements Cr and Ni in the weld pool during welding was achieved by univariate calibration procedure.
Fire resistance testing of components made of carbon fibre reinforced polymers (CFRP) composites usually demands intermediate-scale or full-scale testing. In this study a bench-scale test is presented as practicable and efficient method to assess the improvement in structural integrity of CFRP with different protective coatings during fire.