Filtern
Dokumenttyp
Schlagworte
- Monitoring (25) (entfernen)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (25) (entfernen)
Eingeladener Vortrag
- nein (8)
Additive manufacturing of concrete structures is a novel and emerging technology. Freecontouring in civil engineering, which allows for entirely new designs, is a significant advantage. Inthe future, lower construction costs are expected with increased construction speeds and decreasingrequired materials and workers. However, architects and civil engineers rely on a certain quality ofexecution to fulfil construction standards. Although several techniques and approaches demonstratethe advantages, quality control during printing is highly challenging and rarely applied. Due to thecontinuous mixing process commonly used in 3D concrete printing, it is impossible to exclude varia-tions in the dry mixture or water content, and a test sample cannot be taken as a representative samplefor the whole structure. Although mortar properties vary only locally, a defect in one layer duringprinting could affect the entire integrity of the whole structure . Therefore, real-time process monitor-ing is required to record and document the printing process.At the Bundesanstalt für Materialforschung und -prüfung (BAM) a new test rig for the additive man-ufacturing of concrete is built. The primary purpose is measuring and monitoring the properties of amortar during the printing process.The following study investigates an approach for calculating yield stress and plastic viscosity based onexperimentally recorded pressure data. The calculations assume that fresh mortar behaves as a Bing-ham fluid and that the Buckingham-Reiner-equation is applicable. A test setup consisting of rigid pipeswith integrated pressure sensors at different positions is utilized.Monitoring the printing process with different sensors is crucial for the quality control of an ongoingprocess.
Additive manufacturing of concrete structures is a novel and emerging technology. Free contouring in civil engineering, which allows for entirely new designs, is a significant advantage. In the future, lower construction costs are expected with increased construction speeds and decreasing required materials and workers. However, architects and civil engineers rely on a certain quality of execution to fulfil construction standards. Although several techniques and approaches demonstrate the advantages, quality control during printing is highly challenging and rarely applied. Due to the continuous mixing process commonly used in 3D concrete printing, it is impossible to exclude variations in the dry mixture or water content, and a test sample cannot be taken as a representative sample for the whole structure. Although mortar properties vary only locally, a defect in one layer during printing could affect the entire integrity of the whole structure . Therefore, real-time process monitoring is required to record and document the printing process. At the Bundesanstalt für Materialforschung und -prüfung (BAM) a new test rig for the additive manufacturing of concrete is built. The primary purpose is measuring and monitoring the properties of a mortar during the printing process. The following study investigates an approach for calculating yield stress and plastic viscosity based on experimentally recorded pressure data. The calculations assume that fresh mortar behaves as a Bingham fluid and that the Buckingham-Reiner-equation is applicable. A test setup consisting of rigid pipes with integrated pressure sensors at different positions is utilized. Monitoring the printing process with different sensors is crucial for the quality control of an ongoing process.
Corrosion monitoring of reinforced concrete structures:The DGZfP specification B12 Collaboration
(2023)
Corrosion monitoring of reinforced or prestressed concrete structures has becomeincreasingly important in recent years. Areas of application include componentsthat are no longer accessible after completion or where potential fieldmeasurements cannot be carried out due to existing coatings. Corrosion monitoringcan also be used to monitor the progress of corrosion in corroding systems, e.g. toprove the success of repair measures according to repair principle 8 in accordancewith EN 1504‐9 or repair method 8.3 in accordance with the DIBt repair guideline.It also could be used to prove the functionality of cathodic corrosion protectionsystems in accordance with ISO 12696. Despite the increasing importance ofcorrosion monitoring, no guidelines orrecommendations existed until 2018. Thisgap was closed by the English version of specification B12,“Corrosion Monitoringof Reinforced and Prestressed Concrete Structures,”of the German Society for Non‐Destructive Testing, which was published in 2021. This article introducesspecification B12 by explaining the basicmeasurement principles and illustratingthe potential of corrosion monitoring in new and existing buildings.
Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted.
Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
Monitoring 4.0/5.0
(2021)
Mehr als 10 % des deutschen Bruttoinlandsprodukts werden für Investitionen imBausektor eingesetzt. Die unmittelbar folgende Erkenntnis, dass eine zukunftsorientierte, nachhaltige Umgestaltung unserer Gesellschaft nicht ohne einen substanziellen Beitrag des Bausektors gelingen kann, hat sich mittlerweile weitgehend durchgesetzt. Die Komplexität der zugehörigen technischen Herausforderungen ist jedoch nicht zu unterschätzen.
This specification describes how corrosion monitoring is used to check the condition of reinforced and prestressed concrete members. In this specification, the term "corrosion monitoring" covers all methods in which it is possible to continuously track corrosion-relevant variables in the area of stationary, built-in sensors. This specification does not cover other possible methods, such as potential field measurements, involving the use of mobile, portable sensors that are placed temporarily on the membersurface to take measurements.
The reliability of deteriorating structures at time t is quantified by the probability that failure occurs within the period leading up to time t. This probability is often referred to as cumulative failure probability and is equal to the cumulative distribution function of the time to failure. In structural reliability, an estimate of the cumulative failure probability is obtained based on probabilistic engineering models of the deterioration processes and structural performance. Information on the condition and the loading contained in inspection and monitoring data can be included in the probability estimate through Bayesian updating. Conditioning the probability of failure on the inspection or monitoring outcomes available at time t (e.g. detections or no detection of damages) can lead to a reduction in that probability.
Such a drop in the cumulative failure probability might seem counterintuitive since the cumulative failure probability is a non-decreasing function of time. In this paper, we illustrate—with the help of a numerical example—that such a drop is possible because the cumulative probability before and after the updating is not based on the same information, hence not on the same probabilistic model.
The reliability of deteriorating structures at time t is quantified by the probability that failure occurs within the period leading up to time t. This probability is often referred to as cumulative failure probability and is equal to the cumulative distribution function of the time to failure. In structural reliability, an estimate of the cumulative failure probability is obtained based on probabilistic Engineering models of the deterioration processes and structural performance. Information on the condition and the loading contained in inspection and monitoring data can be included in the probability estimate through Bayesian updating. Conditioning the
probability of failure on the inspection or monitoring outcomes available at time t (e.g. detections or no detection of damages) can lead to a reduction in that probability.
Such a drop in the cumulative failure probability might seem counterintuitive since the cumulative failure probability is a non-decreasing function of time. In this paper, we illustrate—with the help of a numerical example—that such a drop is possible because the cumulative probability before and after the updating is not based on the same information, hence not on the same probabilistic model.
The current practice of operating and maintaining deteriorating structural systems ensures acceptable levels of structural reliability, but it is not clear how efficient it is. Changing the current prescriptive approach to a risk-based approach has great potential to enable a more efficient management of such systems. Risk-based optimization of operation and maintenance strategies identifies the strategy that optimally balances the cost for controlling deterioration in a structural system with the achieved risk reduction. Inspections and monitoring are essential parts of operation and maintenance strategies. They are typically performed to reduce the uncertainty in the structural condition and inform decisions on future operation and maintenance actions. In risk-based optimization of operation and maintenance strategies, Bayesian updating is used to include information contained in inspection and monitoring data in the prediction of the structural reliability. All computations need to be repeated many times for different potential inspection and monitoring outcomes. This motivates the development of robust and efficient approaches to this computationally challenging task.
The reliability of deteriorating structural systems is time-variant because the loads on them and their capacities change with time. In most practical applications, the reliability analysis of deteriorating structural systems can be approached by dividing their lifetime into discrete time intervals. The time-variant reliability problem can then be represented by a series of time-invariant reliability problems. Using this methodology as a starting point, this thesis proposes a novel approach to compute the time-variant reliability of deteriorating structural systems for which inspection and monitoring data are available. The problem is formulated in a nested way in which the prediction of the structural condition is separated from the computation of the structural reliability conditional on the structural condition. Information on the structural condition provided by inspections and monitoring is included in the reliability assessment through Bayesian updating of the system deterioration model employed to predict the structural condition. The updated system reliability is obtained by coupling the updated deterioration model with a probabilistic structural model utilized to calculate the failure probability conditional on the structural condition. This approach is the first main outcome of this thesis and termed nested reliability analysis (NRA) approach. It is demonstrated in two numerical examples considering inspected and monitored steel structures subject to high-cycle fatigue.
An alternative – recently developed – approach, which also follows the strategy of discretizing time, describes deteriorating structural systems with hierarchical dynamic Bayesian networks (DBN). DBN combined with approximate or exact inference algorithms also enable the computation of the time-variant reliability of deteriorating structural systems conditional on information provided by inspection and monitoring data. In this thesis – as a proof of concept – a software prototype is developed based on the DBN approach, which can be used to assess the reliability of a corroding concrete box girder for which half-cell potential measurements are available. This is the second main outcome of this thesis.
Both approaches presented in this thesis enable an integral reliability analysis of inspected and monitored structures that accounts for system effects arising from (a) the correlation among deterioration states of different structural elements, (b) the interaction between element deterioration and system failure, and (c) the indirect information gained on the condition of all unobserved structural elements from inspecting or monitoring the condition of some structural elements. Thus, both approaches enable a systemwide risk-based optimization of operation and maintenance strategies for deteriorating structural systems.
The NRA approach can be implemented relatively easily with subset simulation, which is a sequential Monte Carlo method suitable for estimating rare event probabilities. Subset simulation is robust and considerably more efficient than crude Monte Carlo simulation. It is, however, still sampling-based and its efficiency is thus a function of the number of inspection and monitoring outcomes, as well as the value of the simulated event probabilities. The current implementation of the NRA approach performs separate subset simulation runs to estimate the reliability at different points in time. The efficiency of the NRA approach with subset simulation can be significantly improved by exploiting the fact that failure events in different years are nested. The lifetime reliability of deteriorating structural systems can thus be computed in reverse chronological order in a single subset simulation run.
The implementation of the DBN approach is much more demanding than the implementation of the NRA approach but it has two main advantages. Firstly, the graphical format of the DBN facilitates the presentation of the model and the underlying assumptions to stakeholders who are not experts in reliability analysis. Secondly, it can be combined with exact inference algorithms. In this case, its efficiency neither depends on the number of inspection and monitoring outcomes, nor on the value of the event probabilities to be calculated. However, in contrast to the NRA approach with subset simulation, the DBN approach with exact inference imposes restrictions on the number of random variables and the dependence structure that can be implemented in the model.
In der aktuellen RL-SIB wie auch im Gelbdruck der Instandhaltungsrichtlinie ist bei Anwendung des Instandsetzungsprinzips W-Cl bzw. Verfahren 8.3 der Erfolg der Maßnahme durch Einbau und Messung von Korrosionsstrom-Mess-Einrichtungen nachzuweisen. Auch wird bei der Instandsetzung von chloridbelasteten Rissen bei Stahlbetonbauteilen durch Verpressen der Risse bzw. Aufbringen einer Rissbandage ein Korrosionsmonitoring empfohlen. Anerkannte Regelwerke oder Normen über Art und Aufbau des Monitoring-Systems sowie Kriterien zur Bewertung der Messergebnisse im Hinblick auf den Erfolg der Instandsetzungsmaßnahme gibt es derzeit nicht. Auch sind keine Untersuchungen zur Qualität der Messergebnisse veröffentlicht.
Ziel des Vorhabens ist die Ausarbeitung eines Regelwerks-Entwurfes für die Art und den Aufbau von Korrosionsmonitoring-Systemen sowie für Kriterien zur zuverlässigen Bewertung der Messergebnisse, mit denen der Erfolg bei verschiedenen Instandsetzungskonzepten überprüft werden kann.
Reliability analysis of deteriorating structural systems requires the solution of time-variant reliability problems.
In the general case, both the capacity of and the loads on the structure vary with time. This analysis can be approached by approximation through a series of time-invariant reliability problems, which is a potentially effective strategy for cases where direct solutions of the time-variant reliability problem are challenging, e.g. for structural systems with many elements or arbitrary load processes. In this contribution, we thoroughly Review the formulation of the equivalent time-invariant reliability problems and extend this approximation to structures for which inspection and monitoring data is available. Thereafter, we present methods for efficiently evaluating the reliability over time. In particular, we propose the combination of sampling-based methods with a FORM (first-order reliability method) approximation of the series system reliability problem that arises in the computation of the lifetime reliability. The framework and algorithms are demonstrated on a set of numerical examples, which include the computation of the reliability conditional on inspection data.
The corrosion of steel in reinforced concrete structures is one of the main threats to their durability. Based on the scientific achievements of the past decades the knowledge about the deterioration mechanisms and possible repair strategies for corrosion induced damages have found their way into practice.
It is common sense, that a detailed assessment of the structure is the foundation for a successful repair measure. In addition to the “traditional” singular on-site-procedures such as measurement of concrete cover, carbonation depth, half-cell potentials and chloride contents the monitoring of corrosion related parameters has gained in importance over the past few years.
The advantages of a corrosion monitoring are obvious. In new buildings, structural elements which cannot be assessed after completion (e.g. tunnel segments), or members with electrically isolating coatings can be monitored by means of integrated sensors providing an insight into the development of crucial parameters such as electrochemical potentials, corrosion currents and the electrical resistivity of the concrete. A less known but very beneficial field of application is the use of corrosion monitoring as an integral part of a repair measure based on principles such as the cathodic protection of steel in concrete (CP) or increasing the electrical resistivity of the concrete (IR). By implementing a corrosion monitoring system, it is possible to survey the time dependent effect of the repair measure on the corrosion process which may lead to a confirmation of successful repair measure or to a modification of the repair strategy.
As the principle of cathodic protection for steel in concrete is a recognized repair measure today, the number of applications increases steadily and thus increasing the relevance for corrosion monitoring. Nevertheless, no standards or guidelines concerning the corrosion monitoring are available in Germany today, making it difficult to implement corrosion monitoring in common practice.
With this in mind an international task group formed to develop the specification B12 “Corrosion Monitoring of Reinforced and Prestressed Concrete Structures” published by the German Society for Non-Destructive Testing, DGZfP, spring 2018.
This paper will present the new specification B12 by highlighting the basic measurement principles and illustrating the potentials of corrosion monitoring for new and existing concrete structures by means of case studies.
The corrosion of steel in reinforced concrete structures is one of the main threats to their durability. Based on the scientific achievements of the past decades the knowledge about the deterioration mechanisms and possible repair strategies for corrosion induced damages have found their way into practice.
It is common sense, that a detailed assessment of the structure is the foundation for a successful repair measure. In addition to the “traditional” singular on-site-procedures such as measurement of concrete cover, carbonation depth, half-cell potentials and chloride contents the monitoring of corrosion related parameters has gained in importance over the past few years.
The advantages of a corrosion monitoring are obvious. In new buildings, structural elements which cannot be assessed after completion (e.g. tunnel segments), or members with electrically isolating coatings can be monitored by means of integrated sensors providing an insight into the development of crucial parameters such as electrochemical potentials, corrosion currents and the electrical resistivity of the concrete. A less known but very beneficial field of application is the use of corrosion monitoring as an integral part of a repair measure based on principles such as the cathodic protection of steel in concrete (CP) or increasing the electrical resistivity of the concrete (IR). By implementing a corrosion monitoring system, it is possible to survey the time dependent effect of the repair measure on the corrosion process which may lead to a confirmation of successful repair measure or to a modification of the repair strategy.
As the principle of cathodic protection for steel in concrete is a recognized repair measure today, the number of applications increases steadily and thus increasing the relevance for corrosion monitoring. Nevertheless, no standards or guidelines concerning the corrosion monitoring are available in Germany today, making it difficult to implement corrosion monitoring in common practice.
With this in mind an international task group formed to develop the specification B12 “Corrosion Monitoring of Reinforced and Prestressed Concrete Structures” published by the German Society for Non-Destructive Testing, DGZfP, spring 2018.
This paper will present the new specification B12 by highlighting the basic measurement principles and illustrating the potentials of corrosion monitoring for new and existing concrete structures by means of case studies.
The proposed BAM project SealWasteSafe will advance the state of the art for the construction and monitoring of safe sealing systems for underground repositories of radioactive or toxic waste. During this project, a novel salt concrete exhibiting neither significant cracking nor shrinkage will be optimized for use in the sealing systems. The composition of this material will be based on alkali-activated materials, which are characterized by particularly small thermal deformations during the hardening reaction. Quality assurance and continuous monitoring systems developed during this project will be demonstrated not only for high reliability, but also for resistance to highly alkaline environments and to water intrusion along cables or at sensor locations. A variety of sensors will be used in combination with wireless Radio Frequency Identification (RFID) technology to record moisture, temperature, and, if necessary, corrosion activity within the sealing system. Distributed Fibre Optic Sensor (FOS) technology will also be used for strain, temperature, and moisture content measurement. Ultrasound-based measuring methods will be utilized for the detection of cracks and delaminations. Additionally, digital image correlation and acoustic emission analysis will be used for deformation measurements and crack detection. A novel borehole probe and advanced ultrasound imaging techniques will be further developed to track cracks and delaminations within the host rock in 3D. The surface-based Large Aperture Ultrasound System (LAUS) will also be utilized to detect cracks and delaminations deep below the exterior surface of the sealing system. Although the focus of this project will be on the host rock salt, the resulting technologies will be intentionally developed in a way that facilitates their adaptation to other host rocks.
Mit der Errichtung und der Inbetriebnahme des Windpark alpha ventus wurden umfangreiche Messungen an den Tragstrukturen und den Umgebungsparametern durchgeführt. Im Projekt Gigawind life wurde im TP1 ein Datenmanagementsystem zur kontinuierlichen und periodisch fortgeführten Datenauswertung für große Datenbestände (Big Data) entworfen und realisiert. Anhand von Performanceuntersuchungen konnte eine Verkürzung der Rechenzeit um den Faktor 10 in einem Rechencluster erreicht werden. Unter Anwendung einer Datenpipeline nach dem Publish/Subscribe Prinzip wird eine skalierbare Datenschnittstelle für Monitoringdaten vorgeschlagen.
Messen im Bauwesen 2018
(2018)
Der Tagungsband zur 10. Fachtagung „Messen im Bauwesen“ enthält die Beiträge der Autoren zum diesjährigen Thema „Messtechnische Anwendungen und deren Einbindung in digitale Bauwerksmodelle“ enthält.
Building Information Modeling (BIM) ermöglicht einen integralen Entwurfs-, Ausführungs- und Instandsetzungsprozess und verspricht Bauwerke von höherer Qualität bei niedrigeren Kosten und kürzeren Projektlaufzeiten. Was BIM aber im konkreten Anwendungsfall bedeutet, ist generell noch Teil eines umfassenden Diskussionsprozesses, insbesondere für die Integration der Ergebnisse von Bauwerksmessungen aus der Ausführungs- und Betriebsphase.
Die diesjährige Ausgabe der Tagung „Messen im Bauwesen“ befasst sich schwerpunktmäßig mit verschiedenen Aspekten des BIM in der bestehenden Baupraxis, beschreibt Technologien hinter BIM und zeigt die vielfältigen Möglichkeiten eines Einsatzes von Messverfahren sowohl in der Bauausführung als auch beim Lebenszyklusmanagement von Bauwerken auf. Auf Basis dieser Schwerpunktsetzung möchten wir wieder aus der Sicht des Bauingenieurs und des Geodäten von Praxisbeispielen aus Hoch- und Tiefbau berichten.
Die Vorträge sind zusammengestellt mit Blick insbesondere auf Bau- und Vermessungsingenieure in Ingenieurbüros sowie der Verwaltung in den Bereichen Planung, Ausführung und Betrieb von Infrastrukturbauwerken.
Korrosionsmonitoring von Stahl- oder Spannbetonbauwerken hat in den vergangenen Jahren als Ergänzung zur herkömmlichen Bauwerksuntersuchung deutlich an Relevanz gewonnen. Einsatzgebiete sind z. B. Bauteile, die nach Fertigstellung nicht mehr zugänglich sind oder an denen aufgrund vorhandener Beschichtungen keine Potentialfeldmessungen durchgeführt werden können. Weiterhin kann Korrosionsmonitoring auch für die Überwachung des Korrosionsfortschritts an korrodierenden Systemen z. B. zum Nachweis des Instandsetzungserfolgs bei Anwendung des Prinzips W-Cl gemäß Instandsetzungsrichtlinie des DAfStb oder zum Funktionsnachweis bei KKS-Installationen nach DIN EN ISO 12696 eingesetzt werden. Trotz zunehmender Bedeutung Existieren für das Korrosionsmonitoring bis dato keine Richtlinien oder Handlungsempfehlungen. Diese Lücke soll das Merkblatt B12 „Korrosionsmonitoring von Stahl- und Spannbetonbauwerken“ der Deutschen Gesellschaft für
zerstörungsfreie Prüfung DGZfP füllen, das im Frühjahr 2018
veröffentlicht wurde. In diesem Beitrag werden das Merkblatt B12 vorgestellt, die grundlegenden Messprinzipien erläutert und anhand von Anwendungsbeispielen das Potenzial von Korrosionsmonitoring bei Neubau- und Bestandsobjekten illustriert.
This article introduces an approach and framework for the quantification of the value of structural health monitoring (SHM) in the context of the structural risk and integrity management for systems. The quantification of the value of SHM builds upon the Bayesian decision and utility theory, which facilitates the assessment of the value of information associated with SHM. The principal approach for the quantification of the value of SHM is formulated by modeling the fundamental decision of performing SHM or not in conjunction with their expected utilities. The expected utilities are calculated accounting for the probabilistic performance of a system in conjunction with the associated structural integrity and risk management actions throughout the life cycle, the associated benefits, structural risks, and costs and when performing SHM, the SHM information, their probabilistic outcomes, and costs. The calculation of the expected utilities necessitates a comprehensive and rigorous modeling, which is introduced close to the original formulations and for which analysis characteristics and simplifications are described and derived. The framework provides the basis for the optimization of the structural risk and integrity management based on utility gains including or excluding SHM and inspection information. Studies of fatigue deteriorating structural Systems and their characteristics (1) provide decision Support for the performance of SHM, (2) explicate the influence of the structural component and system characteristics on the value of SHM, and (3) demonstrate how an integral optimization of SHM and inspection strategies for an efficient structural risk and integrity management can be performed.