Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging . We combine an energy dispersive array detector with a coded aperture to obtain high resolution images . To obtain the information from the recorded image a reconstruction step is necessary . The reconstruction methods we have developed , were tested on simulated data and then applied to experimental data . The first tests were carried out at the BAM line @ BESSY II. This method enables the simultaneous detection of multiple elements , which is important e.g. in the field of catalysis.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
Die metallischen Verunreinigungen in Metallen lassen sich mittels hochauflösender Massenspektrometer relativ einfach ermitteln. Die Glimmentladungs-Massenspektrometrie (GD-MS) stellt hierfür eine schnelle Multielementmethode dar. Aufgrund ihrer höheren Anregungs- und Ionisationsenergien ist die Bestimmung von Nichtmetallen eine weit größere Herausforderung. Außerdem fehlt es an für die direkte Feststofftechnik notwendigen Kalibrierstandards z.B. in Form zertifizierter Referenzmaterialien. Für die quantitative Bestimmung von Verunreinigungen wurden mit Standards dotierte Pulverpresslinge und dotierte, gesinterte Materialien auf ihre Eignung als Kalibrierstandards für die GD-MS untersucht. Dabei kamen unterschiedliche Plasmabedingungen (gepulster/ kontinuierlicher Betrieb; verschiedene Plasmagase) zum Einsatz. Ein Überblick über analytische Kenngrößen und Grenzen der verwendeten Kalibrierstrategien wird gegeben. Zur Validierung des Verfahrens wurde die hochauflösende Continuum Source Absorptionsspektrometrie (HR-CS-MAAS) verwendet. Die analytische Nutzung der Molekül-absorptionsspektrometrie zur Bestimmung von Halogenen basiert auf der Bildung insitu-generierter zweiatomiger Moleküle (AlCl, GaF). Die entstehenden Molekülspektren werden im Echelle-Spektrometer aufgespalten und mittels CCD-Array detektiert, was eine sehr empfindliche Messung und präzise Quantifizierung ermöglicht.
In civil engineering, the investigation of existing infrastructure is of major importance for maintaining and ensuring stability of the structures. To ensure durability, uniform regulations and standards apply e.g. the European standard EN 206-1. In some countries, the EN-standard is supplemented by additional standards, as in Germany with DIN 1045-2. Here, specific application rules are described, e.g. for the cement type, to ensure the resistant to different exposures. Therefore, the knowledge of the materials originally used is important in assessing the condition of existing concrete structure. Unfortunately, these are often unknown and must be determined retrospectively. Therefore, we present the application of the laser-induced breakdown spectroscopy to distinguish between different types of cement. Spectral information’s are used to build a classification model. First, the accuracy of the classification is analyzed on ten pure laboratory cement samples. To investigate possible sources of error, the model was then applied to cement samples with different moisture content. The study shows that LIBS is a promising tool for distinguishing between cement types. For further industrial application, however, factors influencing the LIBS signal must be included to ensure a robust model.
We developed a setup for time- and lateral-resolved X-ray absorption fine structure (XAFS) spectroscopy. A dispersive element is placed behind the sample to investigate. The broadband incoming beam transmits the sample, is then dispersed and finally collected by a position sensitive detector. This allows the recording of a whole X-ray absorption near edge structure (XANES) or extended X-ray absorption fine structure (EXAFS) spectrum in a single shot. The dispersive element is a Si(111) crystal, bent by means of a so called wafer bender, developed in house. Our setup is very flexible, easy to adjust and allows a time resolution down to one second which can be used to follow chemical reactions with dynamics on this time scale.
Spatial heterodyne spectroscopy (SHS) is used for quantitative analysis and classification of liquid samples. SHS is a version of a Michelson interferometer with no moving parts and with diffraction gratings in place of mirrors. The instrument converts frequency-resolved information into spatially resolved one and records it in the form of interferograms. The back-extraction of spectral information is done by the Fast Fourier transform. A SHS instrument is constructed with the resolving power 5000 and spectral range 522 - 593 nm. Two original technical solutions are used as compared to previous SHS instruments: the use of a high frequency diode pumped solid state (DPSS) laser for excitation of Raman spectra and a microscope-based collection system. Raman spectra are excited at 532 nm at the repetition rate 80 kHz. Raman shifts between 330 cm-1 and 1600 cm-1 are measured. A new application of SHS is demonstrated: for the first time it is used for quantitative Raman analysis to determine concentrations of cyclohexane in isopropanol and glycerol in water. Two calibration strategies are employed: univariate based on the construction of a calibration plot and multivariate based on partial least square regression (PLSR). The detection limits for both cyclohexane in isopropanol and glycerol in water are at a 0.5 mass% level. In addition to the Raman-SHS chemical analysis, classification of industrial oils (biodiesel, poly(1-decene), gasoline, heavy oil IFO380, polybutenes, and lubricant) is performed using their Raman-fluorescence spectra and principal component analysis (PCA). The oils are easily discriminated as they show distinct non-overlapping patterns in the space of principal components.
While sensors for monitoring the energy source, the melt pool size or temperatures during the process of metal-based Additive Manufacturing (AM) systems are commercially available, the impact of their results on the part quality are often unclear. In the BAM project ProMoAM, results of different process monitoring techniques are combined to achieve quality assurance for the produced parts during the build. Here, first results of simultaneous measurements of optical emission spectroscopy and thermography during the laser metal deposition process using 316L are presented.
Carbon dots have attracted much attention due to their unique optical, chemical and electronic properties enabling a wide range of applications. The properties of carbon dots can be effectively adjusted through modifying their chemical composition. However, a major challenge remains in understanding the core and surface contributions to optical and electronic transitions. Here, three blue luminescent carbon dots with carboxyl, amino and hydroxyl groups were comprehensively characterized by UV-vis absorption and emission spectroscopy, synchrotron-based X-ray spectroscopy, and infrared spectroscopy. The influence of the surface functionality on their fluorescence was probed by pH-dependent photoluminescence measurements. Moreover, the hydrogen bonding interactions between water and the surface groups of carbon dots were characterized by infrared spectroscopy. Our results show that both core and surface electronic states of blue luminescent carbon dots contribute to electronic acceptor levels while the chemical nature of the surface groups determines the hydrogen bonding behavior of the carbon dots. This comprehensive spectroscopic study demonstrates that the surface chemistry has a profound influence on the electronic configuration and surface–water interaction of carbon dots, thus affecting their photoluminescence properties.
The presented work discusses the accuracy of Laser Induced Breakdown Spectroscopy (LIBS) in determining the total chloride content in cement pastes. LIBS as an emission spectroscopy method is used to detect simultaneously several elements present in cement-based materials. By scanning surfaces the variability in the spatial distribution of elements can be visualised. However, for a quantification of the results, studies are necessary to characterise possible influences due to the wide variation of the chemical compositions in which cement can occur. It is shown how the calibration can be done, how the calibration samples were produced, and which statistical parameters are necessary to describe the precision of the regression. The performance of LIBS is estimated by detecting chloride in validation samples. Therefore, 55 samples and 7 ets with changing mix ompositions were produced. The presented study deals with possible influences of different mix compositions, ncluding different cations of chloride, varying w/c-ratios and the artial replacement of Portland cement with last furnace slag (50% BFS) and limestone (30% LS). Comparing the LIBS results with otentiometric titration, n accuracy of±0.05 wt%/total has been determined.