Filtern
Erscheinungsjahr
- 2019 (471) (entfernen)
Dokumenttyp
- Vortrag (221)
- Zeitschriftenartikel (86)
- Beitrag zu einem Tagungsband (79)
- Posterpräsentation (70)
- Dissertation (5)
- Beitrag zu einem Sammelband (3)
- Sonstiges (3)
- Buchkapitel (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (323)
- Deutsch (143)
- Mehrsprachig (4)
- Russisch (1)
Schlagworte
- Additive Manufacturing (34)
- Additive manufacturing (26)
- NDT (22)
- Ultraschall (22)
- Additive Fertigung (21)
- Concrete (20)
- Ultrasound (19)
- Zerstörungsfreie Prüfung (19)
- Computed tomography (15)
- Thermografie (15)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (471) (entfernen)
Eingeladener Vortrag
- nein (221)
Feuchte, sei es Material- oder Gasfeuchte, ist eine wichtige Messgröße bei der Qualitätsbeurteilung von Kunststoffen, landwirtschaftlichen Erzeugnissen, Energieträgern, Arzneimitteln, industriell und medizinisch verwendeten Gasen. Deswegen gibt es ein Interesse Feuchtemesserfahren hinsichtlich Präzision, Wiederholbarkeit, Rückführbarkeit und Stabilität kontinuierlich zu verbessern. Ein bewährtes Messprinzip für diese Aufgabe wurde bereits 1959 von Keidel entwickelt und basiert auf der Absorption und Elektrolyse von Wasserdampf. Der einfache Aufbau dieses Prinzips besteht aus einem Sensorelement, einer Gleichspannungsquelle, einem Digitalmultimeter und einen geregelten Gasstrom über den Sensor. Nach dem Faraday’schen Gesetz der Elektrolyse korreliert bei dem Messprinzip die Ladungsmenge mit der elektrolysierten Wassermasse. Jedoch bedarf es in der heutigen Zeit einer Validierung der Sensoren, weil durch gezielte Miniaturisierung weniger aktive Fläche vorhanden ist und somit das Faraday’sche Gesetz nicht vollständig anwendbar ist. In dieser Arbeit wurden coulometrische Sensoren mit einer planaren Elektrodenstruktur hinsichtlich der Einflüsse von unterschiedlichen Gasen, der Gastemperatur und dem -druck untersucht. Zusätzlich wurde eine neuartige Sensorbeschichtung basierend auf einer ionischen Flüssigkeit getestet. Des Weiteren wurde ein Messgerät für die abgestufte Bestimmung der Materialfeuchte und Wasseraktivität entwickelt und dessen messtechnischer Einsatz untersucht.
Additive Manufacturing (AM) in terms of laser powder-bed fusion (L-PBF) offers new prospects regarding the design of parts and enables therefore the production of lattice structures. These lattice structures shall be implemented in various industrial applications (e.g. gas turbines) for reasons of material savings or cooling
channels. However, internal defects, residual stress, and structural deviations from the nominal geometry are unavoidable.
In this work, the structural integrity of lattice structures manufactured by means of L-PBF was non-destructively investigated on a multiscale approach.
A workflow for quantitative 3D powder analysis in terms of particle size, particle shape, particle porosity, inter-particle distance and packing density was established.
Synchrotron computed tomography (CT) was used to correlate the packing
density with the particle size and particle shape. It was also observed that at least about 50% of the powder porosity was released during production of the struts.
Struts are the component of lattice structures and were investigated by means of laboratory CT. The focus was on the influence of the build angle on part porosity and surface quality. The surface topography analysis was advanced by the quantitative characterisation of re-entrant surface features. This characterisation was compared with conventional surface parameters showing their complementary
information, but also the need for AM specific surface parameters.
The mechanical behaviour of the lattice structure was investigated with in-situ CT under compression and successive digital volume correlation (DVC). The Deformation was found to be knot-dominated, and therefore the lattice folds unit cell layer wise.
The residual stress was determined experimentally for the first time in such lattice structures. Neutron diffraction was used for the non-destructive 3D stress investigation. The principal stress directions and values were determined in dependence of the number of measured directions. While a significant uni-axial stress state was found in the strut, a more hydrostatic stress state was found in the knot. In both cases, strut and knot, seven directions were at least needed to
find reliable principal stress directions.
Gegenüber dem Neubauentwurf können bei der Bewertung von bestehender Bausubstanz Sicherheitsreserven genutzt werden, da Unsicherheiten, die beim Bau auftreten können, besser bekannt oder nicht mehr vorhanden sind. Können solche Unsicherheiten genauer bewertet werden, z. B. durch die Feststellung der genauen Lage der Spannglieder bei einer Spannbetonbrücke, so können Sicherheitsbeiwerte reduziert werden, ohne dass es dabei zu Auswirkungen auf das normativ festgelegte Zuverlässigkeitsniveau kommt. Mittlerweile sind Prüfmethoden an Bauwerken wirtschaftlich einsetzbar und auch so leistungsfähig, dass die für die Tragfähigkeit und Gebrauchstauglichkeit wesentlichen Parameter identifiziert werden können. Ein wesentlicher Punkt ist hierbei die Integration derartiger Messergebnisse in Rechenmodelle, die für die Nachrechnung des Bauwerks verwendet werden. Dies können sowohl semiprobabilistische Rechenmodelle als auch vollprobabilistische Modelle sein. Bei semiprobabilistischen Methoden können aus den Messergebnissen Teilsicherheitsbeiwerte berechnet und abgeleitet werden, die dann in den bekannten Nachweisformaten gemäß den Eurocodes und der Nachrechnungsrichtlinie berücksichtigt werden. Bei vollprobabilistischen Nachweisen können die Messdaten in Form von Verteilungsdichtefunktionen mit gemessenen Variationskoeffizienten direkt in das Rechenmodell eingehen. In einer dreiteiligen Aufsatzreihe werden die Messverfahren und die Nutzung der Ergebnisse bei der Nachrechnung vorgestellt. Der vorliegende Teil 1 zeigt die Möglichkeiten des Einsatzes von zerstörungsfreien Prüfverfahren und bewertet deren Leistungsfähigkeit. Messen heißt wissen. Dieses Wissen spiegelt die Realität wider und soll den Tragwerksplaner bei der Entscheidungsfindung über die Sicherheit und Zuverlässigkeit von Bestandsbauwerken unterstützen.
Composite-Druckgefäße für den Gefahrguttransport sowie für Wasserstoff- und Erdgasfahrzeuge bestehen aus einem lasttragenden Composite und einer gasdichten, metallischen oder polymeren Barriereschicht (Liner). Zur Untersuchung des Alterungsverhaltens solcher Composite-Druckgefäße wurde in der BAM das interdisziplinäre Themenfeldprojekt COD-AGE durchgeführt. Ziel des Projektes war die Entwicklung von Methoden und Modellen zur Beschreibung und Bestimmung des Alterungsverhaltens von Carbonfaser-Compositen am Beispiel von Druckgefäßen, um eine bessere Vorhersage der Alterung und der sicheren Gebrauchsdauer zu ermöglichen. Ein Schwerpunkt in diesem Projekt war die Bereitstellung geeigneter ZfP-Methoden. Dabei ging es sowohl um versuchsbegleitende Prüfungen, als auch um die mögliche Entwicklung von Prüfeinrichtungen für den späteren praktischen Gebrauch.
In dem Vortrag werden Prüfergebnisse der alterungsbegleitenden Wirbelstromprüfung an Composite-Druckgefäßen vorgestellt.
In Alterungsversuchen wurden Druckgefäße aus einem ca. 4 mm dicken Aluminiumliner und ca. 8 mm dicker CFK-Ummantelung untersucht. Typisches Einsatzgebiet solcher Druckgefäße sind Atemschutzgeräte der Feuerwehr. Die Druckgefäße wurden sowohl mit konventioneller Wirbelstromtechnik von außen und von innen als auch mit hochfrequenter Wirbelstromtechnik von außen geprüft. Es konnten sowohl Beschädigungen des metallischen Liners, als auch Strukturen des CFK-Geflechts nachgewiesen werden. Eine besondere mechanische Herausforderung bestand in der Prüfung der Innenseite der Liner, da hier eine zylindrische Fläche mit einem Innendurchmesser von 150 mm durch einen Zugang von nur 15 mm Durchmesser geprüft werden muss.
Composite-Druckgefäße für den Gefahrguttransport sowie für Wasserstoff- und Erdgasfahrzeuge bestehen aus einem lasttragenden Composite und einer gasdichten, metallischen oder polymeren Barriereschicht (Liner). Zur Untersuchung des Alterungsverhaltens solcher Composite-Druckgefäße wurde in der BAM das interdisziplinäre Themenfeldprojekt COD-AGE durchgeführt. Ziel des Projektes war die Entwicklung von Methoden und Modellen zur Beschreibung und Bestimmung des Alterungsverhaltens von Carbonfaser-Compositen am Beispiel von Druckgefäßen, um eine bessere Vorhersage der Alterung und der sicheren Gebrauchsdauer zu ermöglichen. Ein Schwerpunkt in diesem Projekt war die Bereitstellung geeigneter ZfP-Methoden. Dabei ging es sowohl um versuchsbegleitende Prüfungen, als auch um die mögliche Entwicklung von Prüfeinrichtungen für den späteren praktischen Gebrauch.
In dem Vortrag werden Prüfergebnisse der alterungsbegleitenden Wirbelstromprüfung an Composite-Druckgefäßen vorgestellt.
In Alterungsversuchen wurden Druckgefäße aus einem ca. 4 mm dicken Aluminiumliner und ca. 8 mm dicker CFK-Ummantelung untersucht. Typisches Einsatzgebiet solcher Druckgefäße sind Atemschutzgeräte der Feuerwehr. Die Druckgefäße wurden sowohl mit konventioneller Wirbelstromtechnik von außen und von innen als auch mit hochfrequenter Wirbelstromtechnik von außen geprüft. Es konnten sowohl Beschädigungen des metallischen Liners, als auch Strukturen des CFK-Geflechts nachgewiesen werden. Eine besondere mechanische Herausforderung bestand in der Prüfung der Innenseite der Liner, da hier eine zylindrische Fläche mit einem Innendurchmesser von 150 mm durch einen Zugang von nur 15 mm Durchmesser geprüft werden muss.
Trotz moderner Sensortechnologien und Rekonstruktionsmethoden, findet die manuelle und automatisierte Ultraschallprüfung durch konventionelle Senkrecht- und Winkelprüfköpfe vielfach industriellen Einsatz.
Um einen flexiblen Prüfeinsatz und die Prüfbarkeit von einfachen sowie komplexen Geometrien zu gewährleisten, werden dort oftmals Vorlaufkeile für die Winkelprüfung mit Longitudinalwellen angewendet um eine Anzeigenschräglage und deren Reflektivität auszugleichen bzw. zu verbessern. Durch den unterschiedlichen Aufbau, im Vergleich zu integrierten Scherwellen-Winkelprüfköpfen, können jedoch während der Prüfung Fehlanzeigen generiert werden. Diese fehlerhaften Anzeigen beruhen auf Mehrfachreflexionen und Wellenumwandlungen innerhalb des Vorlaufkeils, aufgrund der Geometrie und können im Feld nur bedingt von realen Anzeigen unterschieden werden. Dieser Beitrag zeigt die geometrische Betrachtung bei der Verwendung von Vorlaufkeilen und wurde experimentell durch die Bestimmung der Richtcharakteristik und dem Einsatz von elektrodynamischen Sonden validiert. Des Weiteren ermöglichen die so gewonnenen Abhängigkeiten einen vom Keilwinkel abhängigen Verstärkungsausgleich und somit eine korrekte Größenbestimmung durch einen geeigneten Vergleichsfehler.
Smart geosynthetics with embedded optical fibers as distributed sensors provide solutions both for applications in geotechnical engineering and for cost-effective monitoring of critical infrastructures. The incorporation of glass or polymer optical fibers (GOFs or POFs) in geotextiles and geogrids allows early detection of mechanical deformations, temperature and humidity. This paper presents selected examples of smart geosynthetics based on Brillouin and Rayleigh scattering effects in incorporated fiber optic sensors for monitoring of large geotechnical structures like dikes, dams, railways, embankments or slopes. The focus of the presented work is on real field tests of measurement capability with respect to the chosen measurement principle and used fiber type.
µCT is used to validate the capability of online monitoring for in-situ detection of defects during the L-PBF build process, which is a focus of the TF project ProMoAM.
Our first experiments show that online monitoring using thermography and optical tomography cameras are able to detect defects in the built part. But further research is needed to understand root cause of the correlation.
The Measurement- and Model-based Structural Analysis (MeMoS) integrates a finite element model into least squares adjustment and thus allows to evaluate a mechanical model and measurements in a combined analysis. To examine the capability to detect and localise damage using this integrated analysis MeMoS, a small-scale truss bridge made of aluminium profiles is built as a test specimen for this purpose.
In this paper, we introduce a nano aerial robot swarm for indoor air quality monitoring applications such as occupational health and safety of (industrial) workplaces. The concept combines a robotic swarm composing of nano Unmanned Aerial Vehicles (nano UAVs), based on the Crazyflie 2.0 quadrocopter, and small lightweight metal oxide gas sensors for measuring the Total Volatile Organic Compound (TVOC) in ppb and estimating the eCO2 (equivalent calculated carbon-dioxide) concentration in ppm. TVOC is a measure for the indoor air quality. An indoor localization and positioning system will be used to estimate the absolute 3D position of the swarm like GPS. Based on this novel indoor air quality monitoring concept, the development and validation of new algorithms in the field of Mobile Robot Olfaction (MRO) are planned, namely gas source localization and gas distribution mapping. A test scenario will be built up to validate and optimize the gas-sensitive nano aerial robot swarm for the intended applications.
The Influence of the Temperature Gradient on the Distribution of Residual Stresses in AM AISI 316L
(2019)
Steep temperature gradients and solidification shrinkage are the main contributors to the formation of residual stresses in additively manufactured metallic parts produced by laser beam melting. The aim of this work was to determine the influence of the temperature gradient.
Diffraction results show a similar pattern for both specimens, indicating the shrinkage to be more dominant for the distribution of residual stresses than the temperature gradient. Thermography results imply that a higher energy input result in higher compressive residual stresses in the bulk.
Die Varroose gilt weltweit als eine der bedeutendsten Erkrankungen der westlichen Honigbiene, Apis mellifera. Verursacht wird sie durch den Ektoparasiten Varroa destructor, der durch Saugen der Hämolymphe und Virenübertragung sowohl die Bienenbrut als auch die adulten Individuen schädigt.
Ohne imkerliche Unterstützung gehen betroffene Bienenvölker in der Regel innerhalb von drei Jahren ein. Als bewährte, häufige Behandlung wird flächendeckend 60%ige Ameisensäure (AS) -im Bienenstock appliziert über verschiedene Verdampfungssysteme- eingesetzt. Sie wirkt als einziger zugelassener Wirkstoff gegen die Varroamilbe auch in die verdeckelte Brut hinein und birgt kein Risiko der Resistenzentwicklung.
Allerdings ist das therapeutische Fenster, der Bereich zwischen Milbenabtötung und Bienenschädigung, relativ schmal und die tatsächliche AS-Konzentration im Bienenstock stark abhängig von äußeren Einflussfaktoren, wie Temperatur oder Applikationsart.
Eine Bestimmung der exakten AS-Konzentration im Bienenstock ist also notwendig, um einerseits das Wirkungsoptimum zu bestimmen und andererseits bei Übersteigen der Maximalkonzentrationen mit Folge-Schädigung der Bienen, ein rechtzeitiges Eingreifen der Imker zu ermöglichen.
Die Entwicklung eines Detektors zur Bestimmung der tatsächlichen AS-Konzentration in der Bienenstockluft würde einen großen Fortschritt in den Bereichen der Bienenforschung, der Varroa-Behandlung in der Imkerei, sowie einer gesundheitlich bedenklichen AS-Exposition für den Imker bedeuten.
Langfristiges Ziel dieses Projekts ist es, ein mobiles, einfach handhabbares Gerät zur Detektion der AS-Konzentration in der Bienenstock-Luft während einer AS-Behandlung zu entwickeln.
Grundlage hierfür bietet ein kommerziell verfügbares Multigassensorsystem (PEN3, AIRSENSE Analytics GmbH, Schwerin).
Ziel der beschriebenen Vorversuche ist die generelle Eignungsprüfung des Multigassensorsystems PEN3 zur Detektion der hohen AS-Konzentration in Gasgemischen unter Bedingungen wie sie im Bienenstock während einer AS-Behandlung herrschen.
Als Messplatz zur Detektion von AS in Luft wurden zwei Systeme vorbereitet:
A) Eine Plexiglasbox mit einem Volumen von ca.1,9 l diente als Prüfkammer, wurde von einem Gasstrom befeuchteter synthetischer Luft durchströmt (50 mL min-1, 100 mL min-1 oder 300 mL min-1) und zur Temperierung auf 25 °C auf einer Heizmatte bzw. auf 35 °C in einem Ofen platziert. AS-Wasser-Gemische verschiedener Volumenverhältnisse (0-100%) wurden in einer Glasschale (Oberfläche Flüssigphase 9,6 cm2) in der Prüfkammer vorgelegt.
B) In einer durch eine Heizmatte auf 25 °C temperierten, zwei-zargigen Segeberger Beute wurden vier Messpunkte angebracht (davon drei in der oberen und einer in der unteren Etage) und 60%ige AS über einen Nassenheider-Verdampfer vertikal vorgelegt.
Zur Detektion des AS-Luft-Gemischs wurde das PEN3 Multigassensorsystem genutzt. Das zu untersuchende Gasgemisch wurde über die internen zehn Metalloxid-Halbleiterdetektoren (1-10) der PEN3 geleitet. Das so generierte Messsignal beschreibt ein Widerstandsverhältnis zwischen dem Widerstandwert zum Zeitpunkt der Messung (R) und dem elektrischen Widerstand bei der Nullluft-Messung (R0), wobei hier befeuchtete synthetische Luft mit einer reltativen Feuchte von 49 % ± 4 % oder Raumluft genutzt wurde. Gase unterschiedlicher Zusammensetzung können anhand der dargestellten Signalmuster verschiedener Sensoren voneinander unterschieden werden.
In beiden Messsystemen wiesen die Sensorelemente 1, 6, 7, 8 und 9 gesteigerte Sensitivitäten beim Vorliegen von Ameisensäure im Gasgemisch auf. Die größten Widerstandsverhältnisse zeigten dabei die Sensorelemente 6, 8 und 9, sodass hier von der höchsten Empfindlichkeit für AS auszugehen ist.
Basierend auf den erhobenen Messdatensätzen wurden Hauptkomponenten- (PCA) und lineare Diskriminanzanalysen (LDA) zur Dimensionsreduktion durchgeführt, um charakteristische Muster aus den Messsignalen zu extrahieren. Die PCA- und LDA-Plots für die jeweils bedeutsamsten Komponenten PC 1 und PC 2 bzw. LD 1 und LD 2 eines Versuchslaufs in der Plexiglasbox (A) bei einer Temperatur von 35°C, einem Volumenstrom von 300 mL min-1 und variablen Ameisensäure-Wasser-Volumenverhältnissen von 0 % bis 100 %. Deutlich erkennbar sind die Abhängigkeiten der Komponenten PC 1 und LD 1 (Abszissen) vom vorgelegten AS-Wasser-Volumenverhältnis. Unsere Ergebnisse zeigen, dass das Multigassensorsystem zur Bestimmung von AS in Luft unter ähnlichen Bedingungen wie bei einer AS-Behandlung im Bienenstock angewandt werden kann.
Die Versuche zeigen, dass die im PEN3 eingesetzten Metalloxid-Sensoren bzw. Metalloxidsensor-Arrays zur Detektion von AS in Luft auch bei höheren Konzentrationen als beispielsweise der MAK-Wert von 5 µmol/mol zur Überwachung des AS-Gehaltes in Bienenstöcken angewandt werden können. Aufgrund der Möglichkeit der quasi Echtzeit-Messdatengenerierung, der geringen Kosten kommerziell verfügbarer Sensorelemente, der Portabilität und der Möglichkeit zur Miniaturisierung zeichnen sich solche Messsysteme zukünftig durch eine besondere Praxisnähe aus. Diese Erkenntnisse sind Grundlage für eine Verbesserung des Detektionsverfahrens und zur Vorhersage über die Effizienz und Effektivität der Varroha-Milbenbehandlung.
Feuchte, insbesondere in Form von Flüssigwasser, stellt in Baustoffen ein hohes Schadenspotential dar. Um mit zerstörungsfreier Prüfung mögliche Risikostellen zu lokalisieren und Präventionsmaßnahmen zu ergreifen, sind Kenntnisse über das Porengefüge und Feuchtetransportmechanismen im Baustoff erforderlich. Eine wesentliche Problematik besteht derzeit in der Erfassung und Quantifizierung von Feuchteverteilungen bei Teilsättigung.
Wir verfolgen derzeit einen Ansatz, mittels Nuklear Magnetischer Resonanz (NMR) in Korrelation mit relativen Luftfeuchtmessungen den Flüssigwasseranteil bei Teilsättigung zu ermitteln. Mit Protonen-NMR lassen sich Relaxationszeiten von Wasserstoffprotonen in Abhängigkeit von ihrer Bindungsart und ihrer Umgebung - z. B. Porenstruktur und -größe - erfassen. Allerdings lässt sich bei Materialien mit sehr breiten Porengrößenverteilungen nicht klar differenzieren, ob kurze Relaxationszeiten durch größere teilgesättigte oder kleinere vollgesättigte Poren verursacht werden. Für die Korrelation mit der relativen Luftfeuchte im Baustoff erfolgt zunächst eine künstliche Regulierung im Klimaschrank. Durch einen neuentwickelten Ansatz von Hillerborg lassen sich dann bei jeder Luftfeuchte die adsorbierten Wasserschichtdicken und der Porensättigungsgrad für die vorhandenen Porengrößen berechnen. Mithilfe des berechneten Porensättigungsgrades lässt sich eine genauere Analyse der zeitlichen Entwicklung von Relaxationszeitenverteilungen (insbesondere bei Trocknungs- und Aufsättigungsprozessen) vornehmen. Somit sollen erstmals Aussagen zu kürzeren Relaxationszeiten bei teilgesättigten Porensystemen, die beispielsweise auch eine multimodale Porengrößenverteilung aufweisen, getroffen werden können.
In dieser Arbeit wird die Kombination aus NMR und der relativen Luftfeuchte an sehr porösen Dämmplatten aus Kalziumsilikat, die zur Wärmedämmung sowie der Entgegenwirkung von Schimmelbildung eingesetzt werden, angewendet. Untersucht werden 28 Proben à 6 Gruppen, die von unterschiedlichen Herstellern stammen bzw. unterschiedlich hergestellt wurden.
We demonstrate the use of a 3D printed radial collimator in X-ray powder diffraction and surface sensitive grazing incidence X-ray diffraction. We find a significant improvement in the overall Signal to background ratio of up to 100 and a suppression of more than a factor 3⋅10⁵ for undesirable Bragg reflections generated by the X-ray “transparent” windows of the sample environment.
The background reduction and the removal of the high intensity signals from the windows, which limit the detector’s dynamic range, enable significantly higher sensitivity in experiments within sample environments such as vacuum chambers and gas- or liquid-cells. Details of the additively manufactured steel collimator geometry, alignment strategies using X-ray fluorescence, and data analysis are also briefly discussed. The flexibility and affordability of 3D prints enable designs optimized for specific detectors and sample environments, without compromising the degrees of freedom of the diffractometer.