Filtern
Erscheinungsjahr
- 2019 (33) (entfernen)
Dokumenttyp
- Vortrag (18)
- Posterpräsentation (6)
- Beitrag zu einem Tagungsband (5)
- Zeitschriftenartikel (3)
- Forschungsdatensatz (1)
Referierte Publikation
- nein (33) (entfernen)
Schlagworte
Organisationseinheit der BAM
- 8.6 Faseroptische Sensorik (33) (entfernen)
Eingeladener Vortrag
- nein (18)
AI-reflectivity is a code based on artificial neural networks trained with simulated reflectivity data that quickly predicts film parameters from experimental X-ray reflectivity curves. This project has a common root with (ML-reflectivity)[https://github.com/schreiber-lab/ML-reflectivity] and evolved in parallel. Both are linked to the following publication:
Fast Fitting of Reflectivity Data of Growing Thin Films Using Neural Networks A. Greco, V. Starostin, C. Karapanagiotis, A. Hinderhofer, A. Gerlach, L. Pithan, S. Liehr, F. Schreiber, S. Kowarik (2019). J. Appl. Cryst.
For an online live demonstration using a pre-trained network have a look at github.
We present a technique for distributed temperature gradient sensing in real-time along an optical fiber utilizing simple amplitude-based direct-detection coherent optical time domain reflectometry (C-OTDR) and a special sensing fiber. Our technique enables us to determine phase changes or low-frequency variations of the C-OTDR signal stemming from temperature variations. The distinct feature of the used sensing fiber is its structuring with equidistant strongly scattering dots. Consecutive pairs of these scatterers form the dominant local interferometers, effectively overwriting the otherwise highly nonlinear transfer function of common optical fiber. This enables a quasi-phase-resolved evaluation of perturbation responses originating from temperature changes at sensor positions between the scatterers. Using our method, we show the measurement of a nonlinear temperature transient from a heating process with a maximum temperature gradient of 0.8 °C over 20 s and a total temperature increase of 28.4 °C. This method requires almost no post-processing and can be used for simultaneous distributed vibration sensing (DVS) and quantification of local temperature gradients in a single fiber, e.g., for the use in condition monitoring of infrastructure or industrial installations.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Distributed humidity/water sensing is sought after in wide range of applications including concrete condition monitoring in civil engineering, SHM of large structures such as dykes or dams, soil moisture measurement in agriculture or leak detection in pipeline or sewage industry. Using humidity-induced strain of specialty hygroscopic coating materials, such as polyimide (PI) seems as the most promising approach so far. In this work, relative humidity and temperature response of different commercial PI-coated and tight-buffer fibers is investigated for the development of distributed humidity sensor.
Das Teilprojekt zielt auf die Entwicklung integrierbarer verteilter faseroptischer Sensoren (u. a. verteilte Brillouin-Sensorik, verteilte akustische Sensorik) für die Langzeitüberwachung von Betriebsparametern in Hoch- und Mittelspannungskabelanlagen. Mit Hilfe der Sensoren sollen unzulässige Dehnungen, Übertemperaturen und das Eindringen von Feuchte, z. B. in Unterseekabeln, detektiert werden. Das Teilprojekt beinhaltet ebenfalls die Entwicklung integrierfähiger Sensoren für verteiltes (vibro-)akustisches Monitoring an Unterseekabeln, vor allem zur Lokalisierung und zur Abwendung von Störfällen und Schäden durch äußere mechanische Einflüsse (z. B. Ankerwurf).
We present our research on the development of a Brillouin optical frequency-domain analysis (BOFDA) using a perfluorinated graded-index polymer optical fiber (PFGI-POF) as a sensing fiber. The described works include investigations both on the selection of the setup components with respect to mode coupling effects and on the impact of the humidity cross-sensitivity. The suitability of the developed POF-based BOFDA is proved by a distributed measurement on an 86 m long PFGI-POF recorded with the spatial resolution of 6 m.
The use of artificial neural networks (ANNs) is demonstrated for efficient real-time data processing in optical fiber sensing applications. Using ANN-based algorithms, two orders of magnitude improved computation time and improved measurement resolution is achieved for distributed strain sensing using the wavelength-scanning coherent optical time domain reflectometry technique.
The distributed measurement of relative humidity is a sought-after capability for a wide range of applications in civil engineering and structural health monitoring. We show that polymethyl methacrylate (PMMA) optical fi-bers can be employed as a sensor medium to conduct distributed humidity measurement by analyzing Rayleigh backscattering traces obtained by OTDR. We make use of the effect that water penetrates the fiber core and directly influences the local fiber attenuation and Rayleigh backscatter coefficient. We conducted distributed backscattering analysis for two different pulse wavelengths: 500 nm and 650 nm. The 650 nm results are susceptible to both, attenuation changes and backscatter changes, whereas backscatter results at 500 nm are not affected by humidity-induced attenuation and only exhibit a change of Rayleigh backscattered power as a function of humidity. The combined measurement and analysis of both parameters at these two wavelengths has the advantage that cross-sensitivities on backscatter change and attenuation, such as strain and tempera-ture changes, could be separated from the humidity response of the fiber. We present laboratory results for a humidity range between 30% and 90% for both pulse wavelengths: including step responses, humidity cycles and hysteresis analysis. In addition to the attenuation and backscatter coefficient dependence, we also analyze optical runtime changes as a function of humidity. POFs have the advantage that they can be directly embed-ded into materials such as concrete or soil to measure water content or localize water ingress. Standard step-index PMMA POFs can be used as a distributed relative humidity sensor up to 200 m distance.
We present our research on the development of a Brillouin optical frequency-domain analysis (BOFDA) using a perfluorinated graded-index polymer optical fiber (PFGI-POF) as a sensing fiber. The described works include investigations both on the selection of the setup components with respect to mode coupling effects and on the impact of the humidity cross-sensitivity. The suitability of the developed POF-based BOFDA is proved by a distributed measurement on an 86 m long PFGI-POF recorded with the spatial resolution of 6 m.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Distributed humidity/water sensing is sought after in wide range of applications including concrete condition monitoring in civil engineering, SHM of large structures such as dykes or dams, soil moisture measurement in agriculture or leak detection in pipeline or sewage industry. Using humidity-induced strain of specialty hygroscopic coating materials, such as polyimide (PI) seems as the most promising approach so far. In this work, relative humidity and temperature response of different commercial PI-coated and tight-buffer fibers is investigated for the development of distributed humidity sensor.
In the present study, the impact of static traffic loading on the slight deflection effects in the concrete structure of an existing bridge has been investigated using distributed fiber optic sensors. In the face of increasing traffic density and severe traffic loading, the results of the load tests on the Amsterdam bridge 705 make an important contribution to the understanding of its structural behavior. The concept of the static loading was based on the use of two 36-ton trucks stopped on the bridge at multiple pre-determined locations. The load applied in this way led to location-dependent small deflection effects recorded as longitudinal strain of the sensing fiber embedded at the underside of the bridge. The measurements were performed with a commercially-available solution based on Tunable Wavelength Coherent Optical Time Domain Reflectometry with the measurement accuracy in the range of 0.5 µm/m.
In the present study, the impact of static traffic loading on the slight deflection effects in the concrete structure of an existing bridge has been investigated using distributed fiber optic sensors. In the face of increasing traffic density and severe traffic loading, the results of the load tests on the Amsterdam bridge 705 make an important contribution to the understanding of its structural behavior. The concept of the static loading was based on the use of two 36-ton trucks stopped on the bridge at multiple pre-determined locations. The load applied in this way led to location-dependent small deflection effects recorded as longitudinal strain of the sensing fiber embedded at the underside of the bridge. The measurements were performed with a commercially-available solution based on Tunable Wavelength Coherent Optical Time Domain Reflectometry with the measurement accuracy in the range of 0.5 µm/m.
Wavelength-scanning distributed acoustic sensing for structural monitoring and seismic applications
(2019)
We introduce wavelength-scanning coherent optical time domain reflectometry (WS-COTDR) for dynamic vibration sensing along optical fibers. The method is based on spectral shift computation from Rayleigh backscatter spectra. Artificial neural networks (ANNs) are used for fast and high-resolution strain computation from raw measurement data. The applicability of the method is demonstrated for vibration monitoring of a reinforced concrete bridge. We demonstrate another application example for quasi-static and dynamic measurement of ground deformation and surface wave propagation along a dark fiber in a telecommunication cable.
Wavelength-scanning distributed acoustic sensing for structural monitoring and seismic applications
(2019)
We introduce wavelength-scanning coherent optical time domain reflectometry (WS-COTDR) for dynamic vibration sensing along optical fibers. The method is based on spectral shift computation from Rayleigh backscatter spectra. Artificial neural networks (ANNs) are used for fast and high-resolution strain computation from raw measurement data. The applicability of the method is demonstrated for vibration monitoring of a reinforced concrete bridge. We demonstrate another application example for quasi-static and dynamic measurement of ground deformation and surface wave propagation along a dark fiber in a telecommunication cable.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.
Auf der Grundlage der in DIN EN 61757-2-2:2017 beschriebenen Standardisierungsmethoden wurden in dieser Arbeit wichtige Leistungsparameter von vier kommerziellen Messsystemen zur ortsaufgelösten faseroptischen Erfassung der temperatur- und dehnungsabhängigen Brillouin-Frequenzverschiebung untersucht. Gemäß der oben genannten Norm konzentrierte sich hier die Ermittlungsprüfung auf messtechnische Aspekte reiner Temperaturmessungen. Dabei diente die Ermittlung von einem festgelegten Satz dreier Betriebsverhaltenskenngrößen in Form von quantitativen Angaben des Messfehlers, der Wiederholgenauigkeit sowie der räumlichen Unsicherheit einem Vergleich der getesteten Messsysteme.
Alle faseroptischen Messungen wurden mit einer Faserschleife ausgeführt, d. h. als Sensorkonfiguration der Messfaser wurde eine Schleifenanordnung gewählt. Die Messverfahren der getesteten Messysteme basierten somit auf der Brillouin-optischen Zeit- bzw. Frequenzbereichsanalyse. Die Betriebsverhaltenskenngrößen wurden ferner bei unterschiedlichen Werten zweier messtechnischer Parameter, des Frequenzschrittes und der Mittelungsrate, für Standardeinstellungen der Laserleistungswerte der in die Sensorfaser einzukoppelnden Laserlichtsignale ermittelt. Auf diesem Weg lassen sich relevante Aussagen zur Optimierung der Messgenauigkeiten in Bezug auf Messdauer treffen.
For the purpose of increasing payload and reduce freight cost, lightweight composite tank containers used for Transportation have been progressively developed during the last years. Compared to conventionally produced cylindrical steel tanks, the fiber-reinforced solutions allow greater flexibility in the tank design. Despite a number of further material-related benefits of fiber-reinforced composites as non-conductive and non-magnetic behavior as well as corrosion resistance and high strength, the optimization of their thermal degradation properties during combustion is still a challenge. To improve the fire performance of lightweight composite containers, special intumescent fire protection coatings can be applied onto the outside tank surface. This paper presents fire tests on glass-fiber-reinforced plastic transport tanks with complex geometries sheltered with different surface-applied fire protection systems. To evaluate the fire resistance of the tank structures, a fiber optic monitoring system was developed. This system is based on distributed temperature measurements using high-Resolution optical backscatter reflectometry and pointwise reference measurements using fiber Bragg gratings. Thereby, all the fiber optic sensors were directly integrated in the composite layer structure of the tanks. The focus of the presented work is on the demonstration of capability of fiber optic monitoring system in such high-temperature application. Moreover, the fiber optic measurements provide new insights into the efficiency of intumescent coating applied for fire protection of fiber-reinforced plastic transport tanks.