Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (8697)
- Vortrag (6679)
- Beitrag zu einem Tagungsband (3791)
- Posterpräsentation (2572)
- Beitrag zu einem Sammelband (1209)
- Buchkapitel (252)
- Sonstiges (220)
- Forschungsbericht (189)
- Forschungsdatensatz (140)
- Dissertation (112)
Sprache
- Englisch (24017) (entfernen)
Schlagworte
- Corrosion (377)
- Concrete (375)
- Fluorescence (340)
- Nanoparticles (321)
- Additive manufacturing (279)
- XPS (216)
- Non-destructive testing (209)
- Hydrogen (205)
- Simulation (196)
- LIBS (183)
Organisationseinheit der BAM
- 6 Materialchemie (2040)
- 8 Zerstörungsfreie Prüfung (1701)
- 1 Analytische Chemie; Referenzmaterialien (1580)
- 7 Bauwerkssicherheit (1172)
- 9 Komponentensicherheit (1018)
- 5 Werkstofftechnik (910)
- 4 Material und Umwelt (796)
- 6.3 Strukturanalytik (599)
- 3 Gefahrgutumschließungen; Energiespeicher (562)
- 6.1 Oberflächen- und Dünnschichtanalyse (559)
- 8.5 Röntgenbildgebung (491)
- 6.6 Physik und chemische Analytik der Polymere (423)
- 8.0 Abteilungsleitung und andere (385)
- 9.4 Integrität von Schweißverbindungen (349)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (343)
- 9.3 Schweißtechnische Fertigungsverfahren (338)
- 1.2 Biophotonik (323)
- 1.1 Anorganische Spurenanalytik (298)
- 5.1 Mikrostruktur Design und Degradation (297)
- 2 Prozess- und Anlagensicherheit (256)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (256)
- 7.2 Ingenieurbau (248)
- 1.4 Prozessanalytik (247)
- 7.6 Korrosion und Korrosionsschutz (241)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (238)
- 4.1 Biologische Materialschädigung und Referenzorganismen (236)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (220)
- 1.9 Chemische und optische Sensorik (219)
- 6.2 Material- und Oberflächentechnologien (213)
- 7.4 Baustofftechnologie (207)
- 5.2 Metallische Hochtemperaturwerkstoffe (206)
- 1.8 Umweltanalytik (203)
- 8.4 Akustische und elektromagnetische Verfahren (199)
- 6.0 Abteilungsleitung und andere (196)
- 2.1 Sicherheit von Energieträgern (179)
- 5.4 Multimateriale Fertigungsprozesse (177)
- 8.6 Faseroptische Sensorik (170)
- S Qualitätsinfrastruktur (150)
- 1.7 Organische Spuren- und Lebensmittelanalytik (148)
- 9.5 Tribologie und Verschleißschutz (147)
- 9.0 Abteilungsleitung und andere (143)
- 3.3 Sicherheit von Transportbehältern (137)
- 7.1 Baustoffe (132)
- 3.2 Gefahrguttanks und Unfallmechanik (128)
- 4.5 Kunst- und Kulturgutanalyse (128)
- 3.4 Sicherheit von Lagerbehältern (123)
- 4.3 Schadstofftransfer und Umwelttechnologien (123)
- 4.0 Abteilungsleitung und andere (119)
- 4.2 Material-Mikrobiom Wechselwirkungen (119)
- 9.2 Versuchsanlagen und Prüftechnik (118)
- 9.6 Additive Fertigung metallischer Komponenten (114)
- 5.6 Glas (110)
- 1.5 Proteinanalytik (107)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (106)
- 5.5 Materialmodellierung (100)
- 1.6 Anorganische Referenzmaterialien (99)
- 5.3 Polymere Verbundwerkstoffe (97)
- S.2 Digitalisierung der Qualitätsinfrastruktur (94)
- 7.7 Modellierung und Simulation (89)
- 6.7 Materialsynthese und Design (79)
- 1.3 Instrumentelle Analytik (76)
- VP Vizepräsident (72)
- VP.1 eScience (70)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (69)
- 5.0 Abteilungsleitung und andere (62)
- 3.0 Abteilungsleitung und andere (60)
- 7.0 Abteilungsleitung und andere (60)
- P Präsident (55)
- 3.5 Sicherheit von Gasspeichern (50)
- P.0 Präsident und andere (42)
- 1.0 Abteilungsleitung und andere (40)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (38)
- 7.3 Brandingenieurwesen (34)
- 2.2 Prozesssimulation (32)
- 6.4 Materialinformatik (31)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (21)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (17)
- S.1 Qualität im Prüfwesen (16)
- PST Präsidiale Stabsstelle (15)
- 2.3 Einstufung von Gefahrstoffen und -gütern (14)
- 3.6 Elektrochemische Energiematerialien (14)
- 2.0 Abteilungsleitung und andere (12)
- 4.6 Molekulare und angewandte Entomologie (8)
- 8.3 Thermografische Verfahren (7)
- VP.2 Informationstechnik (4)
- S.0 Abteilungsleitung und andere (3)
- 9.1 Komponenten für Energieträger (2)
- KM Kommunikation, Marketing (1)
- MP Mitglied des Präsidiums (1)
- MP.0 Mitglied des Präsidiums und andere (1)
Paper des Monats
- ja (94)
Anear-infrared (NIR) light-triggered release method for nitric oxide (NO) was developed utilizing core/shell NaYF4: Tm/Yb/Ca@NaGdF4:Nd/Yb up-conversion nanoparticles (UCNPs) bearing a mesoporous silica (mSiO2) shell loaded with theNOdonor S-nitroso-N-acetyl-DL-penicillamine (SNAP). To avoid overheating in biological samples, Nd3+ was chosen as a sensitizer, Yb3+ ions as the bridging sensitizer, andTm3+ ions as UV-emissive activator while co-doping with Ca2+ was done to enhance the luminescence of the activatorTm3+.NOrelease from SNAP was triggered by an NIR-UV up-conversion process, initiated by 808nmlight absorbed by the Nd3+ ions.NOrelease was confirmed by the Griess method. Under 808nmirradiation, the viability of the liver cancer cell line HepG2 significantly decreased with increasing UCNPs@mSiO2-SNAP concentration. For a UCNPs@mSiO2-SNAP concentration of 200 μgml−1, the cell survival probability was 47%. These results demonstrate that UCNPs@mSiO2-SNAP can induce the release of apoptosis-inducingNOby NIR irradiation.
A new “green” and mild synthesis of highly stable microcrystalline Cs2AgxNa1-xBiyIn1-yCl6 (CANBIC) perovskites under ambient conditions was developed that is scalable to the multi-gram production. Under UV illumination, the CANBIC perovskites emit intense broadband photoluminescence (PL) with a quantum yield (QY) of 92% observed for x = 0.35 and y = 0.01-0.02. The combination of strong UV absorbance and broadband visible emission, high PL QY, and long PL lifetimes of up to 1.4 μs, along with an outstanding stability makes these CANBICs a promising material class for many optical applications.
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.
In the past few years, it has been discussed with increasing frequency, whether cube slip does occur in gamma' hardened nickel-base superalloys. Occurrence of cube slip has consequences for the modeling of orientation dependence of the CRSS. Until now, there are only few experimental investigations.
In principle, cube slip should be possible in primitive cubic lattices (e.g. L12 ordered gamma' phase) but not in face centered cubic ones (e.g. Ni solid solution). The most favourable specimen orientations are near [111], where the Schmid factors for this type of glide exceed those for octahedral systems.
There are two basic methods to detect cube slip: macroscopic slip trace analysis and Transmission electron microscopy (TEM) investigation of the dislocation structure. Few observations of cube slip by macroscopic slip traces are reported in the literature. But it is still uncertain under which test conditions cube slip occurs and what the dislocation mechanisms are. Cube slip was observed during tensile or compression tests of several first generation superalloys, but it seems not to occur during shear creep deformation (e.g. CMSX-4 at 980°C), and it is also lacking under conventional tensile or compression loading, if the gmma' particles are small. No observations were ever reported of dislocations gliding on {001} planes in matrix channels.
Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques.
Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments.
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales ondemand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual cam-paigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The re-sulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via compara-bly straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the ob-tained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual cam-paigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The re-sulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via compara-bly straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the ob-tained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market [1]. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algo-rithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibrationfree approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
The aim of the present study is to characterize emeralds from different mines of Brazil by using Synchrotron Radiation X-ray Fluorescence Microanalysis (µ-SRXRF). The advantage of this technique is that we can analyze a homogeneous, inclusion free area of the stone with the microbeam to distinguish the elemental fingerprint according to the provenance of the emerald. A total of 47 samples belonging to 5 different Brazilian mines were studied in this work and 28 elements were identified. By means of Principal Component Analysis (PCA) it is possible to build different groups according to the provenance of the stones, which allows to assign samples of unknown origin to the according mine.
In this work, the structural integrity of LBM fabricated IN625 small cylinders (d = 1 mm, h = 6 mm) was investigated regarding the porosity and the surface roughness by means of computed tomography. The measurements were carried out on a GE v|tome|x L 300/180 with a reconstructed voxel size of 2 µm. The pores were analyzed for size, shape and spatial distribution. The correlation between compactness C and spatial distribution showed that elongated pores (C < 0.2) appear exclusively within a distance of 80 µm to the sample surface. The reconstructed surface was digitally meshed and unwrapped to evaluate the mean roughness Ra. Since the gravity correlates linearly with the sine of the build angle, the influence of gravity on porosity and surface roughness was determined.
µCT is used to validate the capability of online monitoring for in-situ detection of defects during the L-PBF build process, which is a focus of the TF project ProMoAM.
Our first experiments show that online monitoring using thermography and optical tomography cameras are able to detect defects in the built part. But further research is needed to understand root cause of the correlation.