Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der zerstörungsfreien Prüfung wurde in den letzten 10 Jahren kontrovers diskutiert. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wurde erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollziehen sollte. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Speicherfolientechnik eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte erreicht werden kann. Es wird ein Überblick gegeben, welche Parameter zum praktischen Einsatz wichtig sind und wie sie ermittelt werden. Erste Erfahrungen im praktischen Einsatz werden diskutiert.
An approach is presented to construct operators for transforming the characteristics of incident radiation to transmitted radiation, as well as operators for transforming the transmitted radiation to measured values. Simu-lating the radiation transport is based on Monte Carlo modeling of the interaction of X-ray photons and electrons with matter. The proposed method permits to construct, for instance, the operator connecting the initial radiation spectrum with the absorbed photon energy penetrating a given object. The elaborated approach provides the possibility of effective mathematical modeling of radiation techniques such as radiography, treating complex multi-component objects. Moreover, the method can be used to construct the operator equation for solving in-verse problems, e.g. the reconstruction of the initial radiation spectrum using simple experimental measure-ments. Comparison with some experimental measurements is presented.
Computer modelling of non-destructive testing methods has come a long
way from the beginnings in the mid 90s to today. Radiographic modelling for
components with higher wall thicknesses, as they are typical for nuclear
applications, must include precise predictions of scattered radiation and its impact
in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods
with the ability to calculate higher order scattering events are the state of the art for
these applications. Aerospace applications, on the other hand, have stronger
requirements on the modelling code's capabilities to import complex CAD
geometries, and can benefit from faster analytical scatter models, limited to first or
second order scattering events. Similar distinctions can be made for the various
approaches proposed to accurately model geometrical and film unsharpness, film
granularity, film responses, film/foil cartridges and photon noise. This article
presents a state-of-the-art review of radiographic modelling from the perspective of
two important application domains with very different requirements, nuclear and
aerospace.
Biocompatible materials such as porous bioactive calcium phosphate ceramics or titanium are regularly applied in dental surgery: ceramics are used to support the local bone regeneration in a given defect, afterwards titanium implants replace lost teeth. The current gold standard for bone reconstruction in implant dentistry is the use of autogenous bone grafts. But the concept of guided bone regeneration (GBR) has become a predictable and well documented surgical approach using biomaterials (bioactive calcium phosphate ceramics) which qualify as bone substitutes for this kind of application as well. We applied high resolution synchrotron microtomography and subsequent 3d image analysis in order to investigate bone formation and degradation of the bone substitute material in a three-dimensional manner, extending the knowledge beyond the limits of classical histology. Following the bone regeneration, titanium-based implants to replace lost teeth call for high mechanical precision, especially when two-piece concepts are used in order to guaranty leak tightness. Here, synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in these kind of highly attenuating objects. Therefore, we could study micro-gap formation at interfaces in two-piece dental implants with the specimen under different mechanical load. We could prove the existence of micro-gaps for implants with conical connections as well as to study the micromechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential issue of failure, i. e. bacterial leakage which can induce an inflammatory process.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of
diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector
geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen
materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components.
Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in
single projections (radiographs) as function of the detector area coverage and the magnitude of the attenuation.
The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding
beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the
same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is
assumed.
Radiography benchmark 2014
(2015)
The purpose of the 2014 WFNDEC RT benchmark study was to compare predictions of various models of radiographic techniques, in particular those that predict the contribution of scattered radiation. All calculations were carried out for homogenous materials and a mono-energetic X-ray point source in the energy range between 100 keV and 10 MeV. The calculations were to include the best physics approach available considering electron binding effects. Secondary effects like X-ray fluorescence and bremsstrahlung production were to be taken into account if possible. The problem to be considered had two parts. Part I examined the spectrum and the spatial distribution of radiation behind a single iron plate. Part II considered two equally sized plates, made of iron and aluminum respectively, only evaluating the spatial distribution. Here we present the results of above benchmark study, comparing them to MCNP as the assumed reference model. The possible origins of the observed deviations are discussed.
Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions.
This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results.
The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.
This work presents attenuation and sensitivity measurements of radiographic imaging plates (IPs) with quasimonoenergetic X-rays in the 8–60 kiloelectronvolt range. The measurements are used to validate theoretical predictions. A short overview of the theoretical model is given. The model can be used to describe the sensitivity of different detector types to a wide range of X-ray energies.
Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC.