Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Small-area/spot photoelectron spectroscopy (SAXPS) is a powerful tool for the investigation of small surface features like microstructures of electronic devices, sensors or other functional surfaces. For evaluating the quality of such microstructures, it is crucial to know whether a small signal in a spectrum is an unwanted contamination of the field of view (FoV), defined by the instrument settings, or it originated from outside. The aperture has a major influence on the signal-contribution from the outside. For the evaluation of the FoV, we determined the Au4f intensities measured with the center of the FoV aligned with the center of the spot and normalized to the Au4f intensity determined on the Au-film. With this test specimen, it was possible to characterize the FoV: The signal-contribution from the outside is reduceable down to lower than 50 %, when the aperture is 30 % of the structure dimension for our Kratos AXIS Ultra DLD system.
Around 2.5 million tons of municipal sewage sludge (dry matter) are produced in Ger-many every year. The disposal or recycling of this mass often confronts plant operators with considerable problems. In addition to organic substances, sewage sludges also contain important inorganic nutrients that can be recycled. Due to the finite nature of phosphorus as a resource and in favor of natural material cycles, it makes sense to utilize the phosphorus bound in sewage sludge. Therefore, Phosphorus recycling from sewage sludge will be obligatory in Germany from 2029. However, the pollutants pre-sent in sewage sludge, such as heavy metals and organic trace pollutants, are prob-lematic. In many cases, the sewage sludge is incinerated, removing organic compo-nents, and leaving a mineral residue. Various processes exist for the reprocessing of sewage sludge ashes. Reliable analytics and process monitoring are required for all of them.
In this context, the first and most important task of BAM regarding new materials or processes is safety in technology and chemistry through validated and correct analyt-ics. Since there are no reference materials for sewage sludge ashes so far, it is not possible to make any statements about the extent to which the measured values of the comparative measuring methods are correct at all. Therefore, suitable, and representa-tive reference materials are indispensable for the validation of the measurement results and the quality assurance during the entire recycling process. Great care is required to select and prepare these reference materials. The reference materials must corre-spond in matrix to the samples that are to be investigated in the industrial process. An iron-rich and an aluminum-rich sewage sludge ash from mono-incineration plants were selected for this purpose. 10 kg of each sewage sludge ash were homogenized, char-acterized, and prepared. The main, minor and trace element compositions of the sew-age sludge ashes are determined by different measuring methods. The candidate ref-erence materials will be available as BAM-U200 und BAM-U201.