Filtern
Dokumenttyp
- Beitrag zu einem Sammelband (14) (entfernen)
Referierte Publikation
- nein (14)
Schlagworte
- Korrosion (3)
- Spannstahl (3)
- Spannungsrisskorrosion (3)
- Alkali-activated materials (2)
- Geopolymers (2)
- Abwassersysteme (1)
- Acoustic emission (1)
- Alkalisch aktivierte Bindemittel (1)
- Baustoffe (1)
- Beton (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (14) (entfernen)
This contribution presents experimental methods to detect track damage. At BAM (Federal Institute of Material Research and Testing), a measuring car with a measuring system of 72 channels, geophones, mountings, cables, harmonic and impulsive exciters is used for dynamic measurements of the track, the soil and buildings. An instrumented hammer allows force measurements and to evaluate transfer functions of the track, and the soil. Wave measurements are used to identify the soil characteristics. Train passages are measured at the track and for the train induced ground vibrations. In addition to these in situ options, tests of tracks or track elements can be performed in a large laboratory.
Die Ausführung von Abdichtungssystemen insbesondere an Ingenieurbauwerken der Verkehrsinfrastruktur greift in die unmittelbare Verfügbarkeit/Nutzbarkeit des Bauwerks ein und erfolgt deshalb i.a.R. unter höchstem Zeitdruck. Neuere materialtechnische Entwicklungen im Bereich der Flüssigkunststoff-Systeme erlauben kürzere Ausführungszeiten in einem erweiterten Einsatzspektrum. Zur Sicherstellung anforderungsgerechter Gebrauchseigenschaften des gesamten Brückenabdichtungssystems gibt die vorliegende Veröffentlichung Hinweise für die einzuhaltenden Baugrundsätze, bautechnologische Besonderheiten und Erfordernisse im Umgang mit Polymethylmethacrylat (PMMA) sowie qualitätssichernde Maßnahmen.
The present study aims to investigate the use of geopolymer mortars as passive fire protection system for steel structures. Coal fly ashes were used as aluminosilicate source and perlite was employed as aggregate to obtain a lightweight system. In addition, a geopolymer mortar containing quartz aggregate was produced for comparison. The geopolymer mortars were applied on stainless steel plates and exposed to both, cellulosic and hydrocarbon standard fire curves, according to ISO 834-1 and EN 1363-2, respectively. Acoustic emission measurements were conducted to analyze cracking phenomena during the high temperature exposure. The resulting temperature-time curves showed that the investigated system is effective in retarding the temperature rise of the steel plates. When the cellulosic fire curve was applied, a 20 mm [0.79 in.] thick layer of lightweight geopolymer mortar protected the steel substrate from reaching the critical temperature of 500 °C [932 °F] for at least 30 minutes, avoiding the rapid decrease of its mechanical properties and thus representing an important safety measure against accidental fires. No spalling phenomena on heating were detected; however, significant cracking was observed on cooling.
Hydrothermale Herstellung von Filter- und Speichermaterialien aus SiO2- und CaO-reichen Reststoffen
(2019)
Aus SiO2- und CaO-reichen Sekundärrohstoffen können in einem hydrothermalen Stoffumwandlungsprozess poröse Körnungen (Hydrothermalgranulate HTG) hergestellt werden. Die Erhärtung der HTG erfolgt dabei in einem Autoklav bei ca. 200 °C und 1,6 MPa Sattdampf ähnlich dem Prozess der Kalksandsteinherstellung. Festigkeit und Gefüge der HTG entwickeln sich durch die Ausbildung von Calciumsilicathydraten (CSH-Phasen), die durch die Reaktion zwischen Quarzpartikeln (SiO2) und Kalk (CaO) entstehen. SiO2-Lieferant ist ziegelhaltiger Mauerwerkbruch, der als Hauptmineralphase Quarz enthält. Papierasche kann mit ihren Anteilen an Freikalk und anderen reaktive Calciumverbindungen als Kalkersatz dienen. Über die Mischungszusammensetzung und die Reaktionsbedingungen werden die Eigenschaften der Reaktionsprodukte gezielt gesteuert. Die HTG haben Rohdichten kleiner als 2000 kg/m³. Ihr Gefüge ist durch ein eher ungeordnetes System an Mesoporen und kleinen Makroporen mit Porenweiten kleiner 100 nm gekennzeichnet. Diese Porenstruktureigenschaften legen eine Anwendung der HTG als Filter- oder Speichermaterial nahe. Sie können natürliche Rohstoffe, wie Bims, Lavasand und fluviale Sande, aus Primärrohstoffen hergestellte Produkte, wie Blähton, Keramik und Aktivkohle, sowie erdölbasierte Kunststoffadditive ersetzen, wobei die typischen Filter- und Speichereigenschaften der herkömmlichen Produkte nahezu erreicht werden. Dadurch wird einerseits für Reststoffe, die gegenwärtig ein hohes Verwertungsdefizit aufweisen, eine hochwertige Wieder- bzw. Weiterverwertungsmöglichkeit geschaffen und die Abfallmenge vermindert. Andererseits erfolgt eine Schonung von knapper werdenden natürlichen mineralischen Rohstoffen und Erdöl. In einem Forschungsprojekt werden derzeit die technischen Möglichkeiten der hydrothermalen Herstellung von leichten porösen Körnungen aus Mauerwerkbruch, Kalk und Papierasche sowie die Anwendung der HTG als Filtermaterial in Bodenfiltern zur Abwasserreinigung und als Wasserreservoir in Substraten von Pflanzwänden und zur inneren Nachbehandlung hochfester Betone systematisch untersucht. Der Beitrag berichtet insbesondere über die experimentelle Entwicklung der hydrothermalen Synthesestrategie, die nachfolgende Charakterisierung der HTG und die Beziehungen zwischen Gefügekennwerten und technischen Eigenschaften der Körnungen.
Die Brücke am Altstädter Bahnhof in Brandenburg an der Havel stand bei ihrer Eröffnung im Jahr 1969 für die höchste Ingenieurskunst der damaligen Zeit und für einen in die Zukunft gerichteten Blick. Sie trug den Namen "Brücke des 20. Jahrestag", denn am 20. Jahrestag der DDR wurde die Brücke für den Verkehr freigegeben. Sie verbindet die westlichen Stadtbezirke mit dem Zentrum der Stadt Brandenburg an der Havel und wurde so von vielen Einwohner:innen genutzt. Zu Fuß, mit dem Rad, dem Auto oder mit der Straßenbahn.
50 Jahre später, im Dezember 2019, wurde bei einer Bauwerksprüfung eine starke Schadenszunahme festgestellt. Eine sofortige Sperrung für den Verkehr war unumgänglich. Das hatte es im Land Brandenburg bislang nicht gegeben und stellt einen einzigartigen Sonderfall bei der Bewertung von Bauwerken dar. Die Sperrung führte zu starken Einschränkungen für den Verkehr, für den Landesbetrieb Straßenwesen aber hatte die Sicherheit oberste Priorität.
Um die Belastung für die Stadt so gering wie möglich zu halten, hat der Landesbetrieb Straßenwesen sofort mit der Planung für Abriss und Neubau der Brücke begonnen. So gelang es innerhalb von kurzer Zeit den Rückbau umzusetzen und die Pläne für den Ersatzneubau vorzustellen.
Gleichzeitig bot sich die einmalige Gelegenheit, kurz vor dem Rückbau noch umfangreiche Untersuchungen zur Verifizierung des Schadensbilds durchzuführen und verschiedene Monitoringverfahren zum Einsatz zu bringen. Damit wurden wertvolle Erfahrungen gesammelt, die der Landesbetrieb Straßenwesen anderen Baulastträgern zur Verfügung stellen möchte. Sie ermöglichen es, bei baugleichen Bauwerken zielgerichteter handeln zu können. Die Fülle der untersuchten Aspekte ist in diesem Bericht dokumentiert.
Diese umfangreichen Untersuchungen wurden vom Bundesministerium für Verkehr und digitale Infrastruktur finanziert. Dafür möchten wir uns herzlich bedanken. Mit großem Engagement digitabeteiligt haben sich auch die Bundesanstalt für Materialforschung und -prüfung, die Technische Universität Dresden, die Hochschule für Wirtschaft und Technik Dresden sowie das Unternehmen Bilfinger Noell und die Ingenieursozietät Zech, Ruth, Blasius. Auch bei Ihnen bedankt sich der Landesbetrieb Straßenwesen.
Wasserstoffinduzierte Spannungsrisskorrosion an hochfesten und hochempfindlichen Spannstählen führt an bestehenden Brückenbauwerken nach Jahren der Rissinitiierung zu Trag- und Standsicherheitsverlusten. Anhand des Beispiels der Brücke am Altstädter Bahnhof gibt es eine bauartbedingte Schadensinitiierung die über den gesamten Spannkanalquerschnitt zu Spannungsrisskorrosion führen kann.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
There is a strong need for cost-effective mitigation measures for
turnouts. SBB has initiated a series of examinations using different methodologies to gain a deeper understanding of the excitation mechanisms at low frequencies, in addition to that obtained in the RIVAS project. To date it is not yet clear what constitutes a complete measurement data set that would enable understanding most of the vibration excitation mechanisms in turnouts. Increasing vibration at turnouts in comparison to normal track is observed for all measured frequencies.
The different methodologies are presented in the paper. Under-sleeper pads (USP) are a cost-effective method to reduce vibration at frequencies above 63 Hz (1/3 octave), but there is probably no improvement for frequencies below 63 Hz. A first test of new frog geometry did not show relevant improvements in Vibration emission in comparison to a reference frog geometry. Axle box acceleration measurements are an interesting method to identify defects in a turnout. A specialized measurement system of rail roughness could identify certain geometry Problem areas for some frogs. Noise increases also are observed at turnouts for frequencies ranging between 80 to 1000 Hz. The use of railway source models to calculate
contact forces for ballasted track and turnouts seems promising, in particular for understanding the influence of ground.
Ein zentrales Fundament moderner Gesellschaften ist eine intakte Abwasserinfrastruktur. Schäden infolge biogener Schwefelsäurekorrosion von konventionellen Betonen haben jedoch zu einem erheblichen Sanierungsbedarf geführt. Alkaliaktivierte Mörtel besitzen aufgrund eines hohen Säurewiderstands das Potential, einen Beitrag zur langfristigen Lösung dieses Problems zu leisten. Dazu müssen jedoch zunächst die Faktoren, die den Haftverbund zwischen diesen Mörteln und dem Betonsubstrat bestimmen, besser verstanden werden, um die Eigenschaften der Beschichtungssysteme gezielt anpassen und verbessern zu können. Die vorliegende Arbeit liefert hierzu einen Beitrag und zeigt dadurch Wege zu einer technisch machbaren und nachhaltigen Sanierung von Abwasserbauwerken auf.
The aim of this chapter is to give an overview of basic and advanced state-of-the-art microstructural and spectroscopic analytics to investigate inorganic material corrosion in the context of biochemically aggressive sewers. The chapter covers optical methods, electron beam, X-ray and neutron techniques (SEM, MLA, XRF, XRD, CT, Neutron radiography and tomography), and spectroscopic methods (MAS-NMR, FT-IR, and Raman). For each technique, a short section on the fundamental scientific background of the method precedes and examples of data output from the latter in respect to the corrosion of cementitious materials including reinforced concrete is presented.
This chapter aims to give a brief introduction into the field of alkali activated materials (AAM) and their physicochemical material behavior when exposed to sulfuric acid and in biochemically aggressive sewer environments. Additionally, the differences in material behavior within chemical (abiotic) and microbially induced acid environments are highlighted. Finally, existing data on overall performance of AAM, compared to conventional concrete-based building materials in sewer systems will be discussed.
Packaging containers for dangerous goods that include aggressive liquids require that any packaging material that is based on high-density polyethylene has a high degree of stability and durability. This work is focused on testing the environmental stress cracking of the high-density polyethylenes used for such containers in contact with crop protection formulations, in particular, two model liquids established in Germany as standardized test media representatives for crop protection formulations containing the various admixtures typical for such products. One of the liquids is water-based and contains mostly surface-active ingredients, while the other is solvent-based and includes some emulsifiers. Originally established for pin impression tests, these model liquids and their individual components were here used for the first time as environmental media in the Full Notch Creep Test, which addresses the resistance against environmental stress cracking. The Full Notch Creep Test was carried out on five high-density polyethylene types with both model liquids, and also on one selected material with its components. The evaluation was focused on the fracture surface structures, which were visualized by a scanning electron microscope and by optical in situ imaging of the notch opening. While the water-based model liquid and its surface-active individual components induced environmental stress cracking with the characteristic pattern for a craze-crack mechanism and so-called brittle fracture on the surface, the solvent-based model liquid and its soluble ingredients exhibited rather ductile failure behavior, caused by the plasticizing effect on the polymer that reduced the yield stress of the high-density polyethylene.
For both cases, fracture surface analysis, together with side views of the crack opening, showed a clear relation between surface pattern, notch deformation (e.g., by blunting), or crack opening due to crack growth with time to failure and the solubility of the liquids in high-density polyethylene.
Die zunehmende Anwendung hochfesten Betons in ermüdungsbelasteten Bauwerken, herausfordernde Belastungsszenarien im Bereich von On- und Offshore Windenergieanlagen bezüglich sehr hoher Lastwechselzahlen sowie das gleichzeitige Streben nach energie- und ressourcenschonendem Bauen stellen die Bemessung von Beton gegen Ermüdung vor neue Aufgaben. Eine Vielzahl von Studien beschreibt bereits die Auswirkung von Einflussfaktoren wie Mischungszusammensetzung, Feuchte, Probekörpergröße oder Belastungsart auf die Ermüdungsfestigkeit und den Ermüdungsprozess. Aufgrund der unterschiedlichen Geometrien und Mischungen der in den verschiedenen Studien verwendeten Proben sind die Auswirkungen der Einflussfaktoren jedoch kaum miteinander vergleichbar. In dem vom Bundesministerium für Wirtschaft und Klimaschutz (BMWK) geförderten Verbundprojekt WinConFat wurden deshalb verschiedene Einflussfaktoren gezielt an Proben mit einheitlichen Mischungen untersucht. Das durch die Bundesanstalt für Materialforschung und -prüfung (BAM) bearbeitete Teilprojekt fokussierte sich auf den „Einfluss der Probengeometrie und -größe auf die Ermüdung von Beton“. Neben der Erhebung von Daten zur Ermüdungsfestigkeit wurde der Ermüdungsprozess mit zerstörungsfreien Prüf- und Messmethoden untersucht. Diese Prüfmethoden wurden auch hinsichtlich ihrer Anwendbarkeit zur Erfassung der ermüdungsbedingten Schädigungsentwicklung an Betonbauwerken im Rahmen von Monitoringkonzepten bewertet. Untersucht wurden die Ermüdungsfestigkeiten und der Ermüdungsprozess an Zylindern mit drei unterschiedlichen Betonmischungen sowie unterschiedlicher Größe und Schlankheit. Die Ergebnisse dieser Untersuchungen werden im Folgenden vorgestellt und diskutiert.