Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (6708)
- Beitrag zu einem Tagungsband (3160)
- Posterpräsentation (2579)
- Zeitschriftenartikel (1399)
- Beitrag zu einem Sammelband (1185)
- Buchkapitel (222)
- Sonstiges (219)
- Forschungsbericht (187)
- Forschungsdatensatz (141)
- Dissertation (112)
- Video (35)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (30)
- Tagungsband (Herausgeberschaft für den kompletten Band) (28)
- Corrigendum (20)
- Sammelband (Herausgeberschaft für den kompletten Band) (15)
- Monografie (11)
- Handbuch (11)
- Newsletter (2)
- Jahresbericht (1)
- Amtliche Bekanntmachung (1)
Sprache
- Englisch (16066) (entfernen)
Referierte Publikation
- nein (16066) (entfernen)
Schlagworte
- Concrete (277)
- Corrosion (275)
- Nanoparticles (201)
- Additive manufacturing (190)
- Hydrogen (154)
- Fluorescence (152)
- Additive Manufacturing (147)
- NDT (140)
- LIBS (136)
- Simulation (136)
Organisationseinheit der BAM
- 6 Materialchemie (1280)
- 8 Zerstörungsfreie Prüfung (1180)
- 1 Analytische Chemie; Referenzmaterialien (917)
- 7 Bauwerkssicherheit (830)
- 9 Komponentensicherheit (701)
- 5 Werkstofftechnik (576)
- 4 Material und Umwelt (534)
- 3 Gefahrgutumschließungen; Energiespeicher (471)
- 6.1 Oberflächen- und Dünnschichtanalyse (390)
- 6.6 Physik und chemische Analytik der Polymere (296)
Paper des Monats
- ja (3)
In the late 1980s, a new type of corrosion appeared in drinking water installations where galvanized steel pipes failed forming a deep groove with no corrosion at the other surfaces. The reason was discussed quite fiercely between failure analysts and material suppliers. In the end the discussion lead to the solution: inductive welded pipes of a certain sulphur content were prone to selective corrosion. The history of the arguments is discussed using old communications between Wilhelm Schwenk and Wolfgang Stichel, who later published the results in a paper unfortunately only I german.
Thus the knowledge got lost and new cases based on the same material problems are observed in application of so-called C-Steel piping systems. Failure cases are shown.
Analytical Sciences has developed from Ostwald’s “unentbehrlichen Dienstmagd” to a chemical discipline at the core of many of today’s fundamental and applied scientific problems and innovations. An atomic or molecular understanding of basic processes in chemistry, soft matter physics, materials and life science is enabled only through new analytical methods and instrumentation. Similar observations can be found for pressing sociopolitical conflicts of the future: A rational discussion of global climate change or new energy sources is only possible with reliable analytical results. Progress in Analytical Sciences is only possible if the underlying interdisciplinary character is acknowledged and valued. The talk will illustrate the scope of modern Analytical Science through examples from process analysis relevant to modern process intensification and industry 4.0 to bioanalysis and the use of synchrotron radiation to elucidate fundamental reactions materials.
Carrier gas hot extraction (CGHE) is a commonly applied technique for determination of hydrogen in welded joints using a thermal conductivity device (TCD) for quantitative measurement. The CGHE is based on the accelerated hydrogen effusion due to thermal activation at elevated temperatures. The ISO 3690 standard suggests different specimen geometries as well as necessary minimum extraction time vs. temperature. They have the biggest influence on precise hydrogen determination. The present study summarizes the results and experience of numerous test runs with different specimen temperatures, geometries and factors that additionally influence hydrogen determination. They are namely: specimen surface (polished/as-welded), limited TCD sensitivity vs. specimen volume, temperature measurement vs. effects of PID-furnace controller as well as errors due to insufficient data assessment. Summarized, the temperature is the driving force of the CGHE. Two different methods are suggested to increase the heating rate up the reach the desired extraction temperature without changing the experimental equipment. Suggestions are made to improve the reliability of hydrogen determination depended on the hydrogen signal stability during extraction accompanied by evaluation of the recorded data. Generally, independent temperature measurement with calibration specimens is useful for further data analysis, especially if this data is used for calculation of trapping kinetics by thermal desorption analysis (TDA).
This talk highlights a proof-of-concept that demonstrates the ability to calculate high-resolution Fourier transforms. These can be combined with multi-scale modeling to simulate scattering over a wide range, from small-angle scattering to XRD and PDF.
The preprint documenting this is available on the ArXiv here:
https://doi.org/10.48550/arXiv.2303.13435
The Jupyter notebook, VASP calculation details and MOUSE measured scattering patterns are available from this Zenodo repository: https://dx.doi.org/10.5281/zenodo.7764045
We demonstrate a strategy for simulating wide-range X-ray scattering patterns, which spans the small- and wide scattering angles as well as the scattering angles typically used for Pair Distribution Function (PDF) analysis. Such simulated patterns can be used to test holistic analysis models, and, since the diffraction intensity is on the same scale as the scattering intensity, may offer a novel pathway for determining the degree of crystallinity.
The "Ultima Ratio" strategy is demonstrated on a 64-nm Metal Organic Framework (MOF) particle, calculated from Q < 0.01 1/nm up to Q < 150 1/nm, with a resolution of 0.16 Angstrom. The computations exploit a modified 3D Fast Fourier Transform (3D-FFT), whose modifications enable the transformations of matrices at least up to 8000^3 voxels in size. Multiple of these modified 3D-FFTs are combined to improve the low-Q behaviour. The resulting curve is compared to a wide-range scattering pattern measured on a polydisperse MOF powder. While computationally intensive, the approach is expected to be useful for simulating scattering from a wide range of realistic, complex structures, from (poly-)crystalline particles to hierarchical, multicomponent structures such as viruses and catalysts.
We report on the development of ultra-small core-shell silver nanoparticles synthesized by an up-scaled modification of the polyol process. It is foreseen to use these thoroughly characterized particles as reference material to compare the catalytic and biological properties of functionalized silver nanoparticles. Small-angle X-ray scattering (SAXS) analysis reveal a narrow size distribution of the silver cores with a mean radius of RC = 3.0 nm and a distribution width of 0.6 nm. Dynamic light scattering (DLS) provides a hydrodynamic radius of RH = 10.0 nm and a PDI of 0.09. The particles’ surface is covered with poly(acrylic acid) (PAA) forming a shell with a thickness of 7.0 nm, which provides colloidal stability lasting for more than six months at ambient conditions. The PAA can be easily exchanged by biomolecules to modify the surface functionality. Replacements of PAA with glutathione (GSH) and bovine serum albumin (BSA) have been performed as examples. We demonstrate that the particles effectively catalyze the reduction of 4-nitrophenol to 4-aminophenol with sodium borohydride. The tunable catalytic activity of (436 ± 24) L g-1 s-1 is the highest reported in literature for silver nanoparticles.
The chapter gives a brief introduction to (nano)compositecomposite materials having the focus on polymer-based nanocomposites. The different dimensionalities of nanoparticles are introduced, along with their distribution in the matrix.
Different application fields of polymer-based nanocomposites, like flame retardancy, filled rubbers, nanofilled thermosets and thermoplastics, separation membranes and nanodielectrics, are considered in greater detail.
(Pre)Standardisation and Metrology in Microbeam Analysis – Ongoing Activities and Opportunities
(2023)
The presentation addresses the current ongoing projects as well as the gaps and opportunities in microbeam analysis within ISO/TC 202 Microbeam Analysis standardisation body and in-liaison Technical Working Areas (TWAs) at the pre-standardization platform of VAMAS (Versailles Project on Advanced Materials and Standards).
Due to their extreme high hydrogen contents, high molecular weight (HMW-) and ultra-high molecular weight (UHMW-) polyethylene (PE) are a comprehensible choice as neutron radiation shielding material in casks for storage and transport of radioactive materials. But as a direct consequence of inserting radioactive material in such casks, gamma radiation occurs. Hence, the impact of gamma radiation on the molecular structure of polyethylene has to be taken into consideration. Consequently, PE has to withstand any type of gamma radiation induced degradation affecting safety relevant aspects in order to be applicable for long term neutron radiation shielding purposes during the whole storage period (in Germany, for instance, up to 40 years). The scope of our investigation comprises an estimation of the impact of gamma radiation and temperature on the molecular and supra molecular structure of the two types of PE used as neutron radiation shielding cask components. A further point which is worth exploring is to what extent these changes are detectable by conventional analysis methods. Therefore, thermoanalytical measurements were performed such as differential scanning calorimetry (DSC), thermo mechanical analysis (TMA), dynamic mechanical analysis (DMA), and thermo gravimetric analysis (TGA). Additionally optical and weighing methods were applied. With those methods it is possible to detect structural changes in polyethylene induced by exposure to gamma radiation. The observed amounts of changes of the irradiated material are not safety relevant for the application of polyethylene as neutron radiation shielding material; moreover, some properties actually improve via irradiation.
The implementation of new 2-D materials based technologies in production processes requires the development of quality management tools. These have to be underpinned by appropriate measurements. Consequently there is a need for the development of the metrology for measurement methods, the development of certified reference materials (CRM) and finally standardization. This chain represents the ideal way to practically useful standards. The presentation will give an overview on the main players in the field and summarize the recent status of activities. At the highest level the metrology of chemical characterization of 2D materials is in the scope of the International Meter Convention, specifically the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM). Pre-standardization is an activity field of the Versailles Project on Advanced Materials and Standards (VAMAS). Standardization is mainly addressed by addressed ISO Technical Committees. A summary on available CRMs relevant to the characterization of nano materials has been prepared by BAM. Examples from the work of BAM’s Division 6.1 “Surface Analysis and Interfacial Chemistry” showcasing the characterization of chemically modified graphene surfaces are given and specific needs for the development of metrology are addressed.
In the discussion the audience is invited to define specific needs which will be streamlined to the respective bodies!
Tribological profile of hydraulic oils by using SRV. The determination of a set of critical, tribological by using different SRV-based test methods. The SRV-based concept of tribological profile generates the wear volumes on two triboelements (specimen), the extreme pressure properties and friction under different contact pressures.
Thus, the benchmark and validation of hydraulic oils bear on a wider range of tribological properties.
The RR2016 extends with six hydraulic oils to other base oil types including biodegradable fluids, which were all tested according to ASTM D7043 in order to consolidate the correlation between SRV and V104C.
2015 Tianjin explosions
(2016)
In 2015 a series of explosions occurred at a container storage station at the Port of Tianjin, China, on Wednesday, 12 August 2015, that killed over one hundred people and injured hundreds of firemen and others. The first two explosions happened within 30 seconds of each other at the facility. The second explosion was larger and involved the detonation of about 800 tons of ammonium nitrate. The cause of the explosions was not known at first, but an investigation of the Chinese authorities concluded in February 2016 that an overheated container of dry nitrocellulose was the cause of the initial explosion. Colleagues of the Nanjing University of Science and Technology and BAM worked together to analyze the reasons and the process of that incident based on knowledge about the properties of the involved substances, particularly ammonium nitrate and nitrocellulose, and potential mechanism of initiation and propagation.
2015 Tianjin Explosions
(2016)
In 2015 a series of explosions occurred at a container storage station at the Port of Tianjin, China, on Wednesday, 12 August 2015, that killed over one hundred people and injured hundreds of firemen and others. The first two explosions happened within 30 seconds of each other at the facility. The second explosion was larger and involved the detonation of about 800 tons of ammonium nitrate. The cause of the explosions was not known at first, but an investigation of the Chinese authorities concluded in February 2016 that an overheated container of dry nitrocellulose was the cause of the initial explosion. Colleagues of the Nanjing University of Science and Technology and BAM worked together to analyze the reasons and the process of that incident based on knowledge about the properties of the involved substances, particularly ammonium nitrate and nitrocellulose, and potential mechanism of initiation and propagation.
Actions from the meeting in April 2016: 1. Four SAC test methods are in place and were revised: SH/T 0721 (Grease, coefficient of friction and wear), SH/T 0784 (Grease, pass load/O.K. load), SH/T 0847 (Oil, coefficient of friction and wear) and SH/T 0882 released by 11-2014 (Oil, pass load/O.K. load). 2. New test method to evaluate anti-fretting properties of greases based was approved by SAC TC280 and will be released. 3. SAC TC280 accepted the project “Simulation of synchronizer by using SRV”. Draft text to be submitted by 03-2017. Discussions on a parallel ASTM test method. 4. A procedure for “Wear Volume” is under development for SAC TC280.
Gold nanocubes with a monodispersed size distribution (edge = 55 nm) deposited on a silicon wafer. These tiny uniform cubes were produced as reference nanoparticles within the EMPIR project nPSize - Improved traceability chain of nanoparticle size measurements. SEM image acquired at 10 kV with an in-lens secondary electron detector. Image colored in ImageJ using LUT “Orange hot.” Published in Microscopy and Microanalysis 25(S2) (2019) 2328.
The production and processing of ordinary Portland cement are responsible for nearly 5% of the world C02 emissions. Due to the world’s increasing requirement for building materials, this air pollution is growing up in the next decades. Alternative cement such as geopolymers can reduce these emissions effectively, Conventional geopolymer binders, produced ffom fly ash or metakaolin as aluminosilicate source and water-glass or alkali hydroxide Solutions as activator, are often used and studied. It is known that under appropriate conditions the starting materials form a three-dimensional aluminosilicate structure and create a gel-like matrix, In our case, a silica source from wastewater treatment of chlorosilane production and solid sodium aluminate as starting materials are initiated to harden by water. This procedure is known as “just add water” or “one-part” geopolymer formulation. These composites have significant advantages for use on construction site, but their Chemical structure is not extensively analyzed. In this work, a well known one-part geopolymer is investigated by 'H and 27A1 magic-angle spinning nuclear magnetic resonance (MAS NMR) spectroscopy. Furthermore, it is shown that overlapping NMR lines can resolved with echo experiments and
One-part-geopolymers, produced by addition of water to a mixture of solid silica and sodium alumi-nate, are a less exhaustively studied approach to form geopolymeric binders. Depending on the silica source, the reaction products show significant amounts of zeolite Na-A besides amorphous compounds. Previously, 29Si MAS NMR has been used to analyze the chemical structure of such one-part geopolymers, having crystalline structures and amorphous phases (Q2, Q3, Q4).
In this work, pure zeolites and three different one-part-geopolymers cured for 1 day were investigated by 29Si-27Al TRAPDOR NMR. It was used to identify aluminum phases in overlapping silicon sites. Zeolites Na-X (Si/Al=1.4) and Na-Y (Si/Al=2.7) served as model systems to measure the TRAPDOR effect of the structural units Q4(mAl). Both materials show several Q4(mAl) signals, which are all separated by their chemical shifts. The more aluminum surrounds the silicon tetrahedron the higher are the normalized TRAPDOR difference signals (S0/∆S). The intensity ratios between Q4(mAl) to Q4({m-1}Al) of these signals is fixed but vary slightly between both zeolites. These results are transferred to the complex geopolymer structure.
The combination of microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on porous material properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of porosity in ceramics.
Moreover, I will show how not-so-novel 2D characterization techniques, based X-ray refraction, can allow a great deal of insights in the damage evolution in microcracked (and porous) ceramics. I will show how X-ray refraction can detect objects (e.g. microcracks) below its own spatial resolution.
Finally, I will discuss the link between the microstructural findings and the mechanical properties of porous microcracked ceramics.
The combination of microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on porous material properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of porosity in ceramics.
Moreover, I will show how not-so-novel 2D characterization techniques, based X-ray refraction, can allow a great deal of insights in the damage evolution in microcracked (and porous) ceramics. I will show how X-ray refraction can detect objects (e.g. microcracks) below its own spatial resolution.
Finally, I will discuss the link between the microstructural findings and the mechanical properties of porous microcracked ceramics.
In civil engineering the information about the quantitative ingress of harmful species like Cl⁻, Na⁺ and SO²⁻₄ is of great interest to evaluate the remaining life time of structures. These species are triggering different damage processes like the alkali-silica reaction (ASR) or the chloride-induced corrosion of the reinforcement. For the evaluation of the heterogeneous concrete it is necessary to discriminate between the different phases mainly cement matrix and aggregates. The transport processes are only proceeding in the cement matrix therefore the measured concentrations should be regarded to the cement content. For the 2D evaluation of element distributions different multivariate cluster-algorithms like k-means and Expectation-Maximization-algorithm (EM-algorithm) have been tested. The methods are compared and different figures of merit will be presented. After phase separation non-relevant information of the aggregates can be excluded. The ingress of harmful species is then quantified using chemometrics. Due to concrete cores from a parking deck the methods have been validated and verified with standard methods of wet-chemistry.
Graphene derivatives have shown great promise in the field of pathogen binding and sensing. Due to their diverse applications, they show a variety of activities that range from bacterial adhesion to bacterial resistance. Therefore, domination of the graphene-pathogen interactions is highly relevant for producing 2D platforms with the desired applications. In order to gain control over the interactions between graphene and biosystems, mechanisms should be fully understood. The surface functionality of graphene is one of the most important factors that dominates its interactions with biosystems and pathogens. Covalent functionalization is a robust method through which functionality, chemical structure, and subsequently physicochemical properties of graphene are abundantly manipulated. A critical issue for preparing graphene-based 2D materials with a defined surface structure, however, is controlling the functionalization in terms of number, position, and type of functional groups.
Graphene and its derivatives have recently attracted much attention for sensing and deactivating pathogens. However, mechanism of multivalent interactions at the graphene-pathogen interface are not fully understood. Since different physicochemical parameters of graphene play a role at this interface, control over graphene’s structure is necessary to study the mechanism of these interactions. In this work, zwitterionic graphene nanomaterials (ZGNMs) were synthesized with defined isoelectric points and exposure, in terms of polymer coverage and functionality. Then, the switchable interactions of ZGNMs with E. coli were investigated to study the validity of the generally proposed “trapping” mechanism for inactivating pathogens by functionalized graphene derivatives. The ZGNMs were able to controllably trap and release E. coli by crossing their isoelectric points.
Thermographic super resolution techniques allow the spatial resolution of defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. In this work, we report on the extension of this approach towards a full frame 2D super resolution technique. The approach is based on a repeated spatially structured heating using high power lasers. In a second post-processing step, several measurements are coherently combined using mathematical optimization and taking advantage of the (joint) sparsity of the defects in the sample
Thermographic super resolution techniques allow the spatial resolution of defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. In this work, we re-port on the extension of this approach towards a full frame 2D super resolution technique. The approach is based on a repeated spatially structured heating using high power lasers. In a second post-processing step, several measurements are coherently combined using mathematical optimization and taking advantage of the (joint) sparsity of the defects in the sample.
The slip-rolling 2Disk tribometer from Optimol Instruments represented the technological evolution in tribotesting of the well-known AMSLER-type tribometer marketed in 1922. Both use two discs with the same outer diameter rolling against each other on their circumference. In the AMSLER, the lower disc dips into an oil reservoir, whereas in the 2Disk the oil is injected into the contact. The oil supply of the 2Disk is controlled by pump and temperature by a heat exchanger.
2PM FlySCAN: Innovative approach for wide field high resolution imaging of skin tissue volumes
(2016)
Two Photon Microscopy (2PM) is an innovative Technology for high resolution imaging of human skin in vivo and ex vivo. Up to now the method is limited by its interdependence between the field of view and the attainable resolution. The new FlySCAN Technology overcomes these boundaries and enable images sizes of many millimeters by resolutions in the submicrometer range revealing very specific information on clinically and biologically relevant tissue and cell structures. The advantages of the new approach are demonstrated by excellent in vivo and ex vivo tissue images.
2PP-TestArtifact
(2023)
This repository contains a test artifact (TA), also called test structure, designed for two-photon polymerization (also known as Direct Laser Writing (DLW) or Two/Multi-photon lithography (2PA/MPA)). Test artifacts can be used to compare structures, to check options used by the slicer, check the state of the 2PP machine itself or to get a construction guidelines for a certain combination of power, velocity and settings.
The associated paper can be found here: https://dx.doi.org/10.1088/1361-6501/acc47a
General ideas behind the test artifact:
1. optimized for 2PP-DLW
2. should be fast and easy to analyse with optical microscopy or 3. scanning electron microscopy without tilt.
3. short time to fabricate
4. include a reasonable amount of different features
5. bulk and small structures on the substrate
The modeling of waveguides by means of the Scaled Boundary Finite Element Method (SBFEM) has recently been addressed and is considered an effective procedure for the simulation of ultrasonic guided waves in plates and uniform structures, as well as their interaction with defects. This work presents the extension of the known applications like uniform concrete foundation cylinders to structures with more complex shapes and defects. The main focus is the required modeling of 3-D structures in SBFEM to solve these efficiently. Furthermore the coupling of different models is discussed. This involves models like a mainly uniform foundation cylinder with varying material behavior or geometry in certain areas which has to be modeled in 3-D SBFEM. With the presentation of numerical examples the accuracy and performance of the modeling is discussed and the advantages in improving numerical stability are shown.
A series of twelve 3-piperazinyl propenylidene indolone merocyanines was synthesized in a one-pot fashion using a consecutive three-component insertion-coupling-Michael addition sequence. Physicalorganic treatment of the absorption data of a consanguineous series of this library allows semiquantitative Linear Free Energy Relationships (LFERs) to be established and confirmation of the positive Absorption solvatochromicity. All Boc-substituted piperazinyl merocyanines display aggregation induced Emission (AIE), which was corroborated for two solvent systems. In particular, crystallization-induced Emission enhancement (CIEE) induced by ultrasonication could be shown for a model chromophore by confocal laser scanning microscopy (CLSM).
Structure elucidation of complex synthetic copolymers still represents a challenge. A one-dimensional separation technique cannot give the answer to the question: What are the molar mass distribution (MMD), the functionality distribution (FTD), the chemical composition distribution (CCD), the monomer sequence distribution (MSD), the topology differences within a single broad distributed polymer sample?
Is the coupling of liquid chromatographic separation techniques to mass spectrometry able to fill the gaps to a certain degree?
Different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry are able to give information which otherwise are completely inaccessible. In some cases, CID tandem mass spectrometry is applied. Fragmentation of suitable precursor ions resulted in typical fragment ion patterns. This technique enables an additional information on e.g. sequences, structural defects and topology of complex polymer mixtures.
Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces radical the dispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame.
The lecture will provide a series of examples where LC-MS has been applied to evaluate complex macromolecules and mixtures of these.
On- and offline coupling principles will be compared and the pros and cons of both mass spectrometric techniques will be discussed.
Additive Manufacturing (AM) in terms of laser powder-bed fusion (L-PBF) offers new prospects regarding the design of parts and enables therefore the production of complex structures. The quality of the feedstock material receives increasing attention, as it depicts the first part of the L-PBF process chain. The powder quality control in terms of flowability and powder bed packing density is therefore mandatory.
In this work, a workflow for quantitative 3D powder analysis in terms of particle size, particle shape, particle porosity, inter-particle distance and packing density was established. Synchrotron computed tomography (CT) was used to correlate the packing density with the particle size and particle shape for three different powder batches. The polydisperse particle size distribution (PSD) was transformed into a statistically equivalent bidisperse PSD. The ratio of the small and large particles helped to understand the powder particle packing density. While the particle shape had a neglectable influence, the particle size distribution was identified as major contributor for the packing density.
The mixture of ammonium nitrate (AN) prills and fuel oil (FO), usually called ANFO, is extensively used in the mining industry as a bulk industrial explosive. One of the major performance predictors of ANFO mixtures is the fuel oil retention, which is itself governed by the porosity of the AN prills. Standardised tests routinely used to assess oil retention face several important limitations; the first being the difficulty to cover the wide range of porosity contents and morphologies from different types of ammonium nitrate prills; the second being the inability to evaluate the closed porosity, which is an important factor regarding the sensitivity of the explosive to detonation. In this study, we present how X-ray computed tomography (XCT), and the associated advanced data processing workflow, can be used to fully characterise the structure and morphology of AN prills. We show that structural parameters such as volume fraction of the different phases and morphological parameters such as specific surface area and shape factor can be reliably extracted from the XCT data, and that there is a good agreement with the measured oil retention values. XCT can therefore be employed to non-destructively and accurately evaluate and characterise porosity in ammonium nitrate prills.
In civil engineering, the corrosion of steel reinforcements in structural elements of concrete bares a risk of stability-reduction, mainly caused by the exposure to chlorides. 3D computed tomography (CT) reveals the inner structure of concrete and allows one to investigate the corrosion with non-destructive testing methods. To carry out such investigations, specimens with a large artificial crack and an embedded steel rebar have been manufactured. 3D CT images of those specimens were acquired in the original state. Subsequently three cycles of electrochemical pre-damaging together with CT imaging were applied. These time series have been evaluated by means of image processing algorithms to segment and quantify the corrosion products. Visualization of the results supports the understanding of how corrosion propagates into cracks and pores. Furthermore, pitting of structural elements can be seen without dismantling. In this work, several image processing and visualization techniques are presented that have turned out to be particularly effective for the visualization and segmentation of corrosion products. Their combination to a workflow for corrosion analysis is the main contribution of this work.
3D Crack analysis in hydrogen charged lean duplex stainless steel with synchrotron refraction CT
(2016)
Hydrogen in metals can cause a degradation of the mechanical properties, the so-called hydrogen embrittlement. In combination with internal stresses, hydrogen assisted cracking (HAC) can occur. This phenomenon is not completely understood yet. To better characterise the cracking behaviour, it is important to gain information about the evolution of the 3D crack network. For this purpose samples of lean duplex stainless steel were loaded with hydrogen by means of electrochemical charging and investigated by means of synchrotron refraction CT and SEM fractography after uniaxial tensile loading. Synchrotron refraction CT is an analyser-based imaging (ABI) technique. It uses a Si (111) single crystal as analyser, which is placed into the beam path between sample and detector. According to Bragg’s law only incident x-rays within a narrow range around the Bragg-angle are diffracted from the analyser into the detector. Hence, the analyser acts as an angular filter for the transmitted beam. This filtering allows to turn the refraction and scattering of x-rays into image contrast. Refraction occurs at all interfaces, where the density of the material changes and is more sensitive to density changes than the attenuation. Therefore, it is possible to detect smaller cracks than with classical x-ray imaging techniques, like CT, with comparable spacial resolution. It also visualises the 3D structure of the cracks and gains quantitative information about their morphology and distribution. Since cracks introduced by HAC are usually very small and have a small opening displacement, synchrotron refraction CT is expected to be well suited for imaging this cracking mechanism and can be a valuable tool to characterise the formation and the evolution of a 3D crack network.
Hydrogen in metals can cause a degradation of the mechanical properties, the so-called hydrogen embrittlement. In combination with internal stresses, hydrogen assisted cracking (HAC) can occur. This phenomenon is not completely understood yet. To better characterise the cracking behaviour, it is important to gain information about the evolution of the 3D crack network. For this purpose samples of lean duplex stainless steel were loaded with hydrogen by means of electrochemical charging and investigated by means of synchrotron refraction CT and SEM fractography after uniaxial tensile loading. Synchrotron refraction CT is an analyser-based imaging (ABI) technique. It uses a Si (111) single crystal as analyser, which is placed into the beam path between sample and detector. According to Bragg’s law only incident x-rays within a narrow range around the Bragg-angle are diffracted from the analyser into the detector. Hence, the analyser acts as an angular filter for the transmitted beam. This filtering allows to turn the refraction and scattering of x-rays into image contrast. Refraction occurs at all interfaces, where the density of the material changes and is more sensitive to density changes than the attenuation. Therefore, it is possible to detect smaller cracks than with classical x-ray imaging techniques, like CT, with comparable spacial resolution. It also visualises the 3D structure of the cracks and gains quantitative information about their morphology and distribution. Since cracks introduced by HAC are usually very small and have a small opening displacement, synchrotron refraction CT is expected to be well suited for imaging this cracking mechanism and can be a valuable tool to characterise the formation and the evolution of a 3D crack network.
Most crucial for components of complex shape or heterogeneous micro structure, precise control of sintering has decisive influence on dimensional accuracy, mechanical integrity and reliability of sintered components. In these cases, only in situ 3D high-temperature shape screening during shrinkage would allow revealing temporary sinter warpage and hereby caused potential defects. Against this background, nokra Optische Prüftechnik und Automation GmbH, HTM Reetz GmbH and BAM developed a testing device for in situ 3D shape screening for ceramic and glass-ceramic tapes up to 1000°C by means of high-temperature laser profilometry. The local repeatability of the sample-sensor distance (sample height profile) is 10 µm at 1000°C. Current work is focused on dropping these restrictions in sample shape and temperature. In a second testing device, currently being in development, samples up to 5 cm x 5 cm x 5 cm can be measured at temperatures up to 1500°C.The presentation illustrates the current state of this work and possible applications of the method.
The overview of the activity of Federal Institute for Material Research and Testing (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The research of our group is focused on the 3D imaging of AM materials by means of X-ray Computed Tomography at the lab and at synchrotron, and the residual stress characterization by diffraction (nondestructive technique).
Metal Additive Manufacturing (AM) technologies such as Laser Powder Bed Fusion (LPBF) are characterized by layer wise construction, which enable advancements of component design, leading to potential efficiency and performance improvements. However, the rapid cooling rates associated with the process consequently leads to the generation of high magnitude residual stresses (RS). Therefore, a deep understanding of the formation of RS, the influence of process parameters on their magnitude and the impact on mechanical performance is crucial for widespread application. The experimental characterization of these RS is essential for safety related engineering application and supporting the development of reliable numerical models. Diffraction-based methods for RS analysis using high energy synchrotron X-rays and neutrons enable non-destructive spatially resolved characterization of both surface and bulk residual stresses in complex components. This presentation will provide an overview of recent research conducted by the BAM at large scale facilities for the characterization of residual stresses in LPBF metallic alloys. Special focus will be given to the challenges posed by textured LPBF materials for the reliable choice of the diffraction elastic constants (DECs), which is crucial to the accurate calculation of the level of RS.
The focus of the presentation focus will be on 3D imaging by means of X-ray Computed Tomography (XCT) at the lab and at synchrotron, and the non-destructive residual stress (RS) characterization by diffraction of additively manufactured (AM) materials in BAM (Berlin, Germany). The manufacturing defects and high RS are inherent of AM techniques and affect structural integrity of the components. Using XCT the defects size and shape distribution as well as geometrical deviations can be characterized, allowing the further optimization of the manufacturing process. Diffraction-based RS analysis methods using neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk RS in complex components and track their changes following applied thermal or mechanical loads.
The overview of the activity of group 8.5 Micro-NDT (BAM, Belin, Germany) in the field of additively manufacturing material characterization will be presented. The research of our group is focused on the 3D imaging of AM materials by means of X-ray Computed Tomography at the lab and at synchrotron, and the residual stress characterization by diffraction (nondestructive technique).
Hydrogen in metals can cause a degradation of the mechanical properties with possible subsequent hydrogen assisted cracking (HAC). Though, the mechanism of HAC is not completely understood yet and thus suitable methods for in situ investigations to characterise the crack formation are needed. X-ray computed tomography (CT) is a well-known tool for analysing these properties. However, the effective resolution of the detector system limits the detection of small defects by CT. Analyser based imaging (ABI) takes advantage of x-ray refraction at interfaces between volumes of different density, i.e. of cracks, pores, inclusions, etc., within the sample to detect defects smaller than the resolution of the detector system. In this study, measurements on an aluminium alloy weld showed that ABI allows us to resolve the 3D structure of cracks undetected by absorption based CT. Prospective investigations will analyse HAC in steels.
Hydrogen in metals can cause a degradation of the mechanical properties with possible subsequent hydrogen assisted cracking (HAC). Though, the mechanism of HAC is not completely understood yet and thus suitable methods for in situ investigations to characterise the crack formation are needed. X-ray computed tomography (CT) is a well-known tool for analysing these properties. However, the effective resolution of the detector system limits the detection of small defects by CT. Analyser based imaging (ABI) takes advantage of x-ray refraction at interfaces between volumes of different density, i.e. of cracks, pores, inclusions, etc., within the sample to detect defects smaller than the resolution of the detector system. In this study, measurements on an aluminium alloy weld showed that ABI allows us to resolve the 3D structure of cracks undetected by absorption based CT. Prospective investigations will analyse HAC in steels.
To better understand the mechanism of hydrogen assisted cracking (HAC), it is important to investigate the 3D structure of the cracks non-destructively. Since, cracks introduced by HAC are usually very small, conventional x-ray imaging methods often lack the required spatial resolution.
However, the detection of those cracks can be enhanced by taking advantage of refraction at interfaces within the sample.
To image this refractive deflection we employ analyser based imaging (ABI). In this work we aim at proving the enhanced crack detection of ABI by investigating an alluminum alloy weld.
The initial focus of this research was on the development of a general workflow for the documentation and monitoring of historical stained glass windows using structured light scanning.
Therefore windows from different churches, time periods and with different corrosion and damage phenomena were scanned before and after conservation measures.
Laser metal deposition is described with its applications for additive manufacturing. The necessary process chain is discussed, with regard to weld bead dimensions and 3D build-up strategy. Metallurgical cross sections, x-ray and tensile tests are conducted. As demonstrative components, a gas turbine burner and a turbine blade are shown
Laser metal deposition is described with its applications for additive manufacturing. The necessary process chain is discussed, with regard to weld bead dimensions and 3D build-up strategy. Metallurgical cross sections, x-ray and tensile tests are conducted. As demonstrative components, a gas turbine burner and a turbine blade are shown.
3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation
(2004)
Absorption edge tomography, also known as differential tomography at absorption edges, is a method which exploits the sudden change of the attenuation coefficient, when the photon energy crosses the absorption edge of an element. Synchrotron radiation is the best source for absorption edge tomography, because of its small bandwidth, high intensity and easily adjustable photon energy. The synchrotron beamline BAMline at the synchrotron radiation facility BESSY II in Berlin, which is operated by the Bundesanstalt für Materialforschung und -prüfung (BAM), provides a monochromatized beam in a photon energy range from 5 keV up to 80 keV with a bandwidth of 2%, when the double multilayer monochromator is used. Together with the microtomography setup, this enables differential tomography with submicron resolution at the K edge of the elements from chromium up to the lanthanides, and up to uranium, when the L edges are used as well.
In this work, metal organic frameworks (MOFs) embedded in polymer are characterized using differential tomography. MOFs are microporous structures of metal ions, coordinated by organic linker molecules, that can be used in a broad field of applications, especially in gas storage and catalysis. In this work, polymer embedded MOFs were extruded into filaments, which could be used for 3d-printing to profit from the specific properties of the MOFs in polymeric materials combined with the arbitrary shapes provided by 3d-printing. For the extrusion, different polymer classes like ABS, polyester- and polyetherurethanes, as well as different MOFs (ZIF-8, ZIF-67, HKUST-1) were used to create MOF containing filaments with a nominal diameter of 3.0 mm. Differential tomography at the edges of the Zn, Co, and Cu was then used to find the distribution of the corresponding MOF in the filament and to analyze the shape of the inclusions.
Artificial bone replacement by individual customized three-dimensional resorbable bioactive glass has not yet been widely established in the clinical use. This is mainly due to the antagonism of sintering ability and suitable bioactivity. Competitive crystallization often prevents the generation of dense sintered bodies, especially for additive manufactured 3D structures. Previous studies of the fluoride-containing glass F3 have shown its potential to combine both sintering ability and suitable bioactivity. Furthermore, the occurring sintering blockade by surface crystallization of Na2CaSi2O6 was tunable by glass particle size.
In this study the glasses F3, F3-Cu with 1 mol% CuO added at the expense of CaO and the well-known 13-93 were chosen to determine the influence of surface crystallization on 3D printed sinter bodies. For this purpose, grain size fractions in range of smaller 32 µm to 315 µm in fraction size of 6-20 µm were sieved from jaw crushed glass frit as well as glass cubes were cut from casted blocks for all glasses. Sintering behavior of both pressed and printed powder compacts was observed via heating microscopy. Crystallization was determined by DTA and crystallization progress was monitored on fractured sinter bodies and polished cubes via electron and laser scanning microscopy as well as with diffractometry.
Depending on grain size the formation of crystalline support framework along former grain boundaries shows the capability to stabilize fully densified sinter bodies before softening. Beside of this, the generation of complex hierarchic porosity was possible as well.
The aim of the study is to infer the soil stratification from the provided CPT and borehole data. We infer the soil type at any location within the domain of interest from the SBT index Ic (Robertson, 2009). This index can be directly related to the CPT data through an empirical correlation model. In addition, the soil classes contained in the borehole logs can be expressed as bounds on Ic. A log-transformation was applied to Ic, Y = ln(Ic), and Y was modelled by a 3D Random Field, with a fully Bayesian hierarchical Gaussian Process model to explicitly capture uncertainties.
In this contribution a 3D ray tracing model for ultrasonic
field evaluation in inhomogeneous anisotropic materials
such as austenitic welds is presented. The inhomogenity of
austenitic weld material is represented as several
homogeneous layers. The general problem of energy
reflection and transmission at the boundaries of the layers
are solved resulting 3D amplitude and energy reflection and
transmission coefficients. The directivity factor for the ray in
general arbitrary oriented austenitic weld material (including
lay back orientation) is determined based on Lambs
reciprocity theorem. The transducer excited ultrasonic fields
are accurately evaluated by employing ray directivity factor,
transmission coefficients, divergence of the ray bundle and
density of rays. Finally, the comparison between theoretical
and experimental results will be described.
Dislocations are the carriers of plastic deformation. As such, their characterization offers important information on the properties they affect. In this contribution, a new tool is presented, which is incorporated in Amira ZIB Edition and allows for three-dimensional (3D) imaging and quantification of dislocations substructures from thick regions an electron-transparent specimen. In the tool, the dislocation segments are traced on diffraction contrast images that are obtained in the transmission electron microscope (TEM). The uncertainties related to the experimental setup and to the proposed method are discussed on the base of a tilt series.
The present talk serves the routine characterization of the porous structure of unordered anatase NP-fillings by screen printing. Therefore the Focused Ion Beam technique was used to cut a defined volume of material slice per slice of the given material. From each slice electron micrographs are recorded. The won stack of images is than further processed using binarization and segmentation to reconstruct either the mesh of particles or pores. From the calibrated length-scales in the scanning electron microscope it is possible to determine the particular volumes for pore and material.
A wide range of properties in crystalline materials is affected by the presence of dislocations, the carriers of plastic deformation. Dislocations can be thought of as filiform structures, characterized by geometrical factors such as their Burgers vector, slip plane, length per unit volume (dislocation density) and line direction. In technical materials such as functional and structural alloys, as well as in minerals, the understanding of bulk deformation driven by dislocation activity is of paramount importance, and thus also the techniques that allow its characterization. Since decades, diffraction contrast in the transmission electron microscope (TEM) is widely implemented to image and describe two-dimensional (2D) projections of dislocation substructures in thin foils [1]. Recently, the use of electron tomography was applied for the first time to fully reconstruct a 3D dislocation network in a GaN epilayer [2]. Although this latter technique has gained popularity, it usually requires an elaborate experimental setup, as well as sophisticated image post-processing methods for a successful reconstruction. Stereoscopic methods in the TEM also have traditionally allowed the three-dimensional (3D) observation of dislocations [e. g. 3]. For this purpose, the same region of a TEM foil is imaged using the same diffraction vector with two beam directions slightly tilted from each other. Subsequently, the pair of images is observed with help of stereo-viewers or 3D glasses. Based on this principle, a system based on a special hardware and software combination was developed for segmentation and analysis of stereomicroscopy data in biological research, and it was also used to analyze simple dislocation structures [4]. In the present contribution a simple software tool is introduced, which has been developed to reconstruct, visualize and quantify dislocation substructures in the thicker regions of electron-transparent foils. A special focus is set on the use of scanning (S)TEM for its implementation.
As depicted in Figure 1, the tool is based on the separate tracing of dislocation line segments on both images of a stereo-pair. The points 1, 2 and 3 are marked on the images viewed by the left and right eyes (Figures 1a and b, respectively), showing an relative displacement Δx on the superimposed images in the anaglyph of Figure 1c. This Δx is given by the point’s depth Δh and by the stereo-angle ϑ, as shown in Figure 1d. By knowing the beam direction for the left and right images (BL and BR, respectively), ϑ can be determined, and hence also Δh. Once the depth information from all traced nodes is gained, a reconstruction is made (Figure 1e) where the line length can directly be read from the tool’s interface. The setup is merely geometrical and only needs the relative tilt between both images, the direction of the tilt axis and the image calibration, thus allowing asymmetrical tilts with respect to the foil normal. The foil thickness is measured directly from the endings of the dislocations on the bottom and top surfaces of the TEM foil, and is determined as t ~ 370 nm for the region in Figure 1. With t, the volume is in Figure 1e is also known, and the total dislocation density of the region is calculated as ρt = 44.4 x 1012 m∙m-3. It is clear from Figure 1 that in the Ni-base superalloy presented here, the dislocation substructures are highly localized towards the interface between the two phases of which the microstructure is composed, γ and γ’ (labeled in Figure 1a). The reconstructed model allows a separation of the dislocation densities within the γ and the γ’ phases and at their interface, which would be rather difficult by using common methods such as the one proposed by Ham [5]. Thus the partial dislocation densities are measured as ργ = 1.7 x 1012 m∙m-3, ργ’ = 2.7 x 1012 m∙m-3 and ργ/γ’ = 40.0 x 1012 m∙m-3. The tool also incorporates the knowledge of the crystallographic positions at the two tilts to enable plotting the line segment orientations. One can chose to display the resulting line directions as an interactive table; as an additional spherical spatial graph, where all lines extend from the center of a sphere; as a 2D plot of the spherical coordinates θ and φ; or as points plotted on a stereographic projection.
Thus, a simple software tool has been developed that allows the reconstruction, visualization and quantification of foil thickness, localized dislocation densities (or other filiform substructures) and orientations based on only one stereo-pair
Dislocations, as carriers of plastic deformation, affect important properties in technical materials, e. g., plasticity. The realistic description of plastic deformation caused by dislocations demands the representative measurement of their features, e.g., line direction, slip plane, Burgers vector and density. Bulk deformation of structural and functional alloys requires reliable data from large regions. The filiform nature of dislocations interacting with complex microstructures additionally demands observation and analysis techniques that allow resolving the details of their interactions in space. The use of electron tomography for this purpose is bound to difficult and time consuming experimental setups, which are not always applicable to any material. In this contribution a new tool is presented, which enables the three-dimensional reconstruction, visualization and quantification of dislocation densities and directions from manual tracing of scanning transmission electron microscopy (STEM) stereo-pairs. Examples are shown from samples of a creep-deformed monocrystalline Ni-base superalloy.
For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany.
The Alpine Fault at the West Coast of the South Island (New Zealand) is a major plate boundary that is expected to rupture in the next 50 years, likely as a magnitude 8 earthquake. The Deep Fault Drilling Project (DFDP) aimed to deliver insight into the geological structure of this fault zone and its evolution by drilling and sampling the Alpine Fault at depth. Here we present results from a seismic survey around the DFDP-2 drill site in the Whataroa Valley where the drillhole almost reached the fault plane. This unique 3D seismic survey includes several 2D lines and a 3D array at the surface as well as borehole recordings. Within the borehole, the unique option to compare two measurement systems is used: conventional three-component borehole geophones and a fibre optic cable (heterodyne Distributed Vibration Sensing system (hDVS)). Both systems show coherent signals but only the hDVS system allowed a recording along the complete length of the borehole.
Despite the challenging conditions for seismic imaging within a glacial valley filled with sediments and steeply dipping valley flanks, several structures related to the valley itself as well as the tectonic fault system are imaged. The pre-processing of the seismic data also includes wavefield separation for the zero-offset borehole data. Seismic images are obtained by prestack depth migration approaches.
Within the glacial valley, particularly steep valley flanks are imaged directly and correlate well with results from the P-wave velocity model obtained by first arrival travel-time tomography. Additionally, a glacially over-deepened trough with nearly horizontally layered sediments is identified about 0.5 km south of the DFDP-2B borehole.
With regard to the expected Alpine fault zone, a set of several reflectors dipping 40-56° to the southeast are identified in a ~600 m wide zone between depths of 0.2 and 1.2 km that is interpreted to be the minimum extent of the damage zone. Different approaches image one distinct reflector dipping at 40°, which is interpreted to be the main Alpine Fault reflector. This reflector is only ~100 m ahead from the lower end of the borehole. At shallower depths (z<0.5 km), additional reflectors are identified as fault segments and generally have steeper dips up to 56°. About 1 km south of the drill site, a major fault is identified at a depth of 0.1-0.5 km that might be caused by the regional tectonics interacting with local valley structures. A good correlation is observed among the separate seismic data sets and with geological results such as the borehole stratigraphy and the expected surface trace of the fault.
In conclusion, several structural details of the fault zone and its environment are seismically imaged and show the complexity of the Alpine Fault at the Whataroa Valley. Thus, a detailed seismic characterization clarifies the subsurface structures, which is crucial to understand the transpressive fault’s tectonic processes.
The quality of components made by laser beam melting (LBM) additive manufacturing is naturally influenced by the quality of the powder bed. A packing density <1 and porosity inside the powder particles lead to intrinsic voids in the powder bed. Since the packing density is determined by the particle size and shape distribution, the determination of these properties is of significant interest to assess the printing process. In this work, the size and shape distribution, the amount of the particle’s intrinsic porosity, as well as the packing density of micrometric powder used for LBM, have been investigated by means of synchrotron X-ray computed tomography (CT). Two different powder batches were investigated: Ti–6Al–4V produced by plasma atomization and stainless steel 316L produced by gas atomization. Plasma atomization particles were observed to be more spherical in terms of the mean anisotropy compared to particles produced by gas atomization. The two kinds of particles were comparable in size according to the equivalent diameter. The packing density was lower (i.e., the powder bed contained more voids in between particles) for the Ti–6Al–4V particles. The comparison of the tomographic results with laser diffraction, as another particle size measurement technique, proved to be in agreement.
The quality of components made by laser beam melting (LBM) additive manufacturing is naturally influenced by the quality of the powder bed. A packing density < 1 and porosity inside the powder particles lead to intrinsic voids in the powder bed. Since the packing density is determined by the particle size and shape distribution, the determination of these properties is of significant interest to assess the printing process. In this work, the size and shape distribution, the amount of particle’s intrinsic porosity as well as the packing density of micrometric powder used for LBM have been investigated by means of synchrotron X-ray computed tomography (CT). Two different powder batches were investigated: Ti-6Al-4V produced by plasma atomization and Stainless Steel 316L produced by gas atomization. Plasma atomization particles were observed to be more spherical in terms of the mean anisotropy compared to particles produced by gas atomization. The two kinds of particles are comparable in size according to the equivalent diameter. The packing density is lower (i.e. the powder bed contains more voids in between particles) for the Ti-6Al-4V particles. The comparison of the tomographic results with laser diffraction, as another particle size measurements techniques, proved agreement.
Application of 4Q-BSE detector and dedicated software enables 3D surface measurements of fracture samples in SEM. 3D surface measurement is independent from magnification and material invariant. Quantitative height measurements require careful detector adjustment and system calibration. Live 3D view allows a fast assessment of topographical features. In addition to SE and BSE imaging, 3D surface data help to analyse and interpret fracture samples.
The focus of the presentation focus will be on 3D imaging by means of X-ray Computed Tomography (XCT) at the lab and at synchrotron, and the non-destructive residual stress (RS) characterization by diffraction of different kind of materials in FB8.5 Micro-NDT BAM. For instance, the manufacturing defects and high RS are inherent of additively manufacturing techniques and affect structural integrity of the components. Using XCT the defects size and shape distribution as well as geometrical deviations can be characterized, allowing the further optimization of the manufacturing process. Diffraction-based RS analysis methods using neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk RS in complex components and track their changes following applied thermal or mechanical loads.
High-energy radiography is traditionally used for the detection of defects in thick-walled, bulky components. It is also used for testing the integrity of components for civil and security-related applications, e.g. containers. The combination of high-energy sources with digital detector arrays or line cameras allows carrying out the tests either in a shorter time compared to film technique, or with higher contrast sensitivity.
The high-energy X-ray laboratory "HEXYLab" at BAM is a joint laboratory in which future users, manufacturers and scientists collaborate to initiate and develop joint development projects. The new universal manipulation system “HEXYTech” provides the engineering and technical base for meeting different requirements within HEXYLab.
Different types of trajectories for tube, object and detector can be programmed with a total of 13 rotational and linear axes. In particular, large objects with complex geometries can be examined. Measurements can be acquired as 2D images via standard radiography as well as 3D volumes from laminography or computed tomography reconstructions.
The general rules for the application of high-energy radiography with digital detectors (imaging plates, digital detector arrays) were determined within the framework of the European project "HEDRad" (High Energy Digital Radiography) and added to the standard DIN EN ISO 17636-2.
The paper gives an overview of the test technique and introduces several applications on the basis of experiments and reconstructed 3D- images.
Non-destructive testing (NDT) of concrete structures is performed using pulse-echo methods. According to the type of the applied waves it can be classified as acoustic (Impact-Echo, Ultrasonics) and electromagnetic methods (Radar). The results are visualised through different imaging processes. This work is performed in the frame of a research project promoted by Deutsche Forschungsgemeinschaft (FOR384).The objective of data fusion is to use the complementary information of the different methods. Radar can detect metallic reflectors in concrete (metallic ducts and concrete reinforcement) very well. This method is not able to locate defects behind these reflectors (injecting defects, defects behind close concrete reinforcement), because the electromagnetic waves are completely reflected at metals. The acoustic methods are able to compensate this deficit i.e. acoustic waves can penetrate through metal. But acoustic waves in the ultrasonic range are completely reflected by air layers. Air layers have smaller influence on radar propagation, so that both methods complement each other.In order to be able to combine the NDT-data from several methods records at the same volume, the different data setsmodes of signals must be adapted. The ultrasonic and radar data have to be reconstructed with programs based on the Synthetic Aperture Focusing Technique (SAFT) before data fusion. Subsequently, a conversion of the data into a uniform format has to be carried out. This is a prerequisite in order to keep the data exchange between the project partners as simple as possible. After the data sets are imported and transferred into a common reference system, they can be processed with operations according to the purpose of the investigation. Results, which have been achieved in concrete test specimen with radar and ultrasonics, will be presented and will show the feasibility of the data fusion method.