Filtern
Erscheinungsjahr
- 2019 (28) (entfernen)
Dokumenttyp
- Vortrag (12)
- Zeitschriftenartikel (10)
- Posterpräsentation (6)
Sprache
- Englisch (28)
Schlagworte
- Nanoparticle (28) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (21)
- 1.2 Biophotonik (13)
- 1.1 Anorganische Spurenanalytik (8)
- 6 Materialchemie (6)
- 1.8 Umweltanalytik (4)
- 6.6 Physik und chemische Analytik der Polymere (3)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 6.3 Strukturanalytik (1)
Eingeladener Vortrag
- nein (12)
Dose enhancement by gold nanoparticles (AuNP) was shown to increase the biological effectiveness of radiation damage in biomolecules and tissue. Most of the current studies focus on external beam therapy on combination with AuNP. Here we present a Monte-Carlo study (Geant4) to characterise radioactive AuNP. Radioactive 198 Au emits beta and gamma rays and is considered for applications with solid tumours. To effectively apply 198 AuNP their energy deposit characteristics have to be determined in terms of intrinsic and extrinsic properties e.g. AuNP diameter, AuNP density, and their clustering behaviour. After each decay process, the energy deposit, inelastic scattering events, kinetic energy spectrum of secondary particles within the AuNP themselves and in a spherical target volume of water up to 1 μm radius were determined. Simulations were performed for AuNP radii ranging from 2.5 nm to 20 nm radius, different cluster sizes and densities. The results show an increase of the energy deposit in the vicinity of the AuNP up to 150 nm. This effect nearly vanishes for distances up to one micron. For the case of AuNP clusters and the same activity, the enhancement of the energy deposit increases with the relative gold mass percentage and therefore can be adjusted by changing AuNP radius or clustering behaviour.
Nowadays, different nanoparticles have been developed for commercial applications. However, since data on toxicity are barely available, their increasing application in cosmetic products, food and their release in the environment might cause severe problems. Since a range of physical, chemical, and biological characteristics of NPs are closely related to particle size and surface functionalization, precise separation and surface groups quantification is essential to acquire an in-depth understanding of their properties.
In this work, the performance of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for the separation of nanoparticles (NPs) with different sizes, coatings, and coating densities was investigated and optimized.
For the first time, a two-dimensional off-line hyphenation of both techniques (AF4-CE) was developed. The results clearly demonstrated, that AF4-CE hyphenation can significantly improve the separation resolution and reduce the peak broadening in CE. Also, for the first time, CE was employed to determine the coating density of NPs and the results were in good agreement with the values acquired with conductometric titration.
Non-linear optical emitters are promising materials for energy applications and biotechnologies. Solid-state multi-band emitters like lanthanide doped up-conversion nanoparticles (UCNPs) show excellent photostability, are excitable in the near infrared (NIR), and show emission bands from the UV to SWIR spectral regions. The optical properties of these materials strongly depend on the excitation power density, i.e., the number of photons absorbed per time interval. The upconversion (ΦUC) and downshifting quantum efficiencies (ΦDS) of these materials, the excitation power dependent population, and the deactivation dynamics are influenced by nanoparticle architecture, doping concentration, and the microenvironment. We studied the fundamental changes of the luminescence properties of ß-NaYF4 UCNPs doped with Yb3+ and Er3+ depending on size, different surroundings such as aqueous and organic media, and different surface chemistries. We obtained further insights into shelling procedures, FRET optimization, influence of doping concentration, and advantages of different sensitizer ions.
Yb,Nd,Er-doped upconversion nanoparticles (UCNPs) have attracted considerable interest as luminescent reporters for bioimaging, sensing, energy conversion/shaping, and anticounterfeiting due to their capability to convert multiple near-infrared (NIR) photons into shorter wavelength ultraviolet, visible or NIR luminescence by successive absorption of two or more NIR photons. This enables optical measurements in complex media with very little background and high penetration depths for bioimaging. The use of Nd3+ as substitute for the commonly employed sensitizer Yb3+ or in combination with Yb3+ shifts the excitation wavelength from about 980 nm, where the absorption of water can weaken upconversion luminescence, to about 800 nm, and laser-induced local overheating effects in cells, tissue, and live animal studies can be minimized. To systematically investigate the potential of Nd3+ doping, we assessed the performance of a set of similarly sized Yb3+,Nd3+,Er3+-doped core- and core–shell UCNPs of different particle architecture in water at broadly varied excitation power densities (P) with steady state and time-resolved fluorometry for excitation at 980 nm and 808 nm. As a measure for UCNPs performance, the P-dependent upconversion quantum yield (Φ) and its saturation behavior were used as well as particle brightness (B). Based upon spectroscopic measurements at both excitation wavelengths in water and in a lipid phantom and B-based calculations of signal size at different penetration depths, conditions under which excitation at 808 nm is advantageous are derived and parameters for the further optimization of triple-doped UCNPs are given.
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pHsensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
Two nanosensors for simultaneous optical measurements of the bioanalytically and biologically relevant analytes temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nmsized silica-coated polystyrene nanoparticles (PS-NPs) doped with a near-infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3, CrBPh4) and an inert reference dye (Nile Red, NR or 5,10,15,20tetrakis(pentafluorophenyl) porphyrin, TFPP) and are covalently labeled with pHsensitive fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal spectrally distinguishable emission bands, allowing for ratiometric intensity-based and time-resolved studies in the visible and near-infrared wavelength region. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of these nanosensors for the sensitive luminescence readout of TOP simultaneously at the same spatialposition.
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20-tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pH-sensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
In this paper, we describe the labelling of antibodies by gold nanoparticles (AuNPs) with diameters of 10 and 60 nm with detection by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Additionally, the AuNPs labelling strategy is compared with commercially available labelling reagents based on MeCAT (metal coded affinity tagging). Proof of principle experiments based on dot blot experiments were performed. The two labelling methods investigated were compared by sensitivity and limit of detection (LOD). The absolute LODs achieved were in the range of tens of picograms for AuNP labelling compared to a few hundred picograms by the MeCAT labelling.
In contrast to microplastics, little is known about nanoplastics (1 to 100 nm). In order to make the dectecability of nanoplasics more reliable, we started to develop nanoplastic reference materials. This project also aims to anser the question of how the single chain conformation of bio(polymers) changes in contact with nanoplastics. Small-angle X-ray and neutron scattering methods are suitable methods for studing this topic. Recently the soft and hard interactions between polystyrene nanoplasics and human serum albumin corona was investigated with small-angle neutron scattering. Here we concentrate on small-angle X-ray scattering as our favorite method to study how (bio)polymers change their conformation in contact with nanoplastics. The scattering of bovine serum albumin in its native state can be detected easily. The scattering pattern of this biopolymer changes dramatically when its globular stucture changes to a coil structure. Modeling of chain conformations and the calculation of the scattering pattern is relatively easy to perform. Numerous model calculations will be provided to predict the changes of conformation of single bio(polymer) chains when in conatact with nanoplastics. These predictions will be compared with recent experimenal results from in situ measurments of bio(polymers) in contact with nanoplastics. The impact of temperature, polymer concentration and salt on the single-chain conformation changes will be discussed.
OECD test guideline on particle size and size distribution: Comparability of measurement results
(2019)
OECD-Prüfrichtlinien werden weltweit für regulatorische Zwecke angewandt, da sie eine harmonisierte und über internationale Ringversuche validierte Vorschrift zur Analyse vorgeben. Die bestehende Prüfrichtlinie TG 110 zur Größencharakterisierung von Partikeln und Fasern ist für viele Methoden und Materialklassen nicht geeignet, weswegen es Bedarf an einer Neuentwicklung gibt. Im Fokus der neuen TG steht die reproduzierbare und vergleichbare Anwendung von Methoden zur Bestimmung von Partikelgröße sowie Größenverteilung annährend sphärischer und faserförmiger Nanomaterialien im Bereich 1-1000 nm. Berücksichtigt werden die häufig angewandten Methoden zur Größencharakterisierung mit ihren unterschiedlichen physikalisch-technischen Limitierungen und die Bestimmung unterschiedlicher Durchmesser (hydrodynamischer, Feret…). Weiterhin sind materialspezifische Einflüsse durch die Partikel sowie das Messmedium zu berücksichtigen. Jede der Methoden soll unter Berücksichtigung von ISO-Standards und den materialspezifischen Limitierungen in der neuen Prüfrichtlinie beschrieben und über einen Ringversuch validiert werden.