Engineering Modelling
(2019)
This chapter presents the most commonly used approach to analyse the
thermo-mechanical behaviour of concrete structures subjected to high temperatures as in the case of fire loading. Prescriptions of the Eurocode are detailed for the thermal as well as the mechanical analysis. Finally, recommendations from two national (Austrian and German) guidelines give some improvements for Underground infrastructure.
Advanced Modelling
(2019)
Concrete is a complex material and can be modeled on various spatial and temporal scales. While simulations on coarse scales are practical for engineering applications, a deeper understanding of the material is gained on finer scales. This is at the cost of an increased numerical effort that can be reduced by the three methods developed and used in this work, each corresponding to one publication.
The coarse spatial scale is related to fully homogenized models. The material is described in a phenomenological approach and the numerous parameters sometimes lack a physical meaning. Resolving the three-phase mesoscopic structure consisting of aggregates, the mortar matrix and the interfaces between them allow to describe similar effects with simpler models.
Spalling of concrete due to fire exposure can lead to severe damage of building components. It is a much discussed subject in structural engineering and not yet completely understood. Generally, it is assumed that thermohydraulic and thermomechanical processes induce tensile stresses in the concrete. Furthermore, the tensile strength of concrete is reduced due to increasing temperatures. The combination of an increasing tensile stress and a decreasing tensile strength result in the occurrence of explosive spalling. The spalling behaviour of concrete is influenced by many parameters, for instance the water cement ratio, porosity, permeability of concrete as well, the presence of steel reinforcement and polypropylene fibres, also the size and geometry of the fire exposed area. Within the current research project at Bundesanstalt für Materialforschung und prüfung (BAM), the susceptibility to spalling of six different concrete mixtures is analysed to quantify the size effect using small scale, intermediate scale and full scale tests. A special fire test setup was built to test specimens simultaneously to enable a better comparability. All specimens are tested without additional mechanical load and unrestraint to prevent external induced cracking at the fire exposed site. Thermocouples are used to measure in situ the temperature distribution as an indication on the thermal degradation of the concrete during the fire tests. Afterwards the maximum spalling depth and the damaged area of the specimen are illustrated by a photogrammetric measurement system. The contribution to the spalling workshop presents the results of four concrete mixtures tested in intermediate-scale and full-scale fire tests. The comparisons are based on the concrete temperature as well as the obtained photogrammetric data. The results show that the spalling depth and the spalling area are significantly affected by the size of the fire exposed area.
Fatigue in Concrete
(2019)
The current knowledge about fatigue behavior of concrete is still incomplete. This concerns especially the progress of fatigue which precedes the fatigue failure. An overview on the fatigue behaviour in concrete is given. Therefore, the process of fatigue itself under cyclic compressive loading was investigated in a systematic and comprehensive way. The aim of this investigation was to obtain a deeper insight and to provide a better understanding of the damage process occurring within the material during fatigue loading.
Sustainability means meeting the needs of today without compromising the needs of the next generations. How can we meet the needs of the next generations, if we do not even know what these needs are? If we do not listen to the next generation and learn from them? Do we even meet the needs of today for everyone on earth?
Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbedingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanierungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz.
Zahlreiche Schädigungsprozesse in Baustoffen stehen im engen Zusammenhang mit Feuchteeintrag und Feuchtetransport. Als Beispiel sind die schädigende Alkali-Kieselsäurereaktion (AKR) von Beton sowie Frost-Tauwechsel induzierte Gefügeschäden genannt. Zur zerstörungsfreien, ortsaufgelösten Feuchtemessung eignet sich die im Bereich der Geophysik etablierte, aber im Bauingenieurwesen noch wenig verbreitete, Messmethode der Nuklear Magnetischen Resonanz (NMR). Unter Verwendung der NMR-Relaxometrie sind sowohl Aussagen zum Feuchtegehalt und dessen räumliche Verteilung als auch die Charakterisierung der Porengrößen möglich, die das Transportverhalten eines porösen Materials maßgeblich beeinflussen.
Zur Erfassung der Mikro- und Mesoporen in Baustoffen ist dabei die Auflösung von kurzen T2 Relaxationszeiten unabdingbar. Bisher ist es mit gängigen NMR-Laborgeräten nur begrenzt möglich, solche kurzen T2-Zeiten schichtselektiv zu erfassen. Vor diesem Hintergrund wurde ein speziell für die Messung an mineralischen Baustoffen optimierter NMR-Tomograph beschafft. Dieser ermöglicht sowohl schichtselektive Messungen von Bohrkernen mit Durchmessern von bis zu 70 mm als auch bildgebende Untersuchungen an Proben mit Durchmessern ≤ 40 mm.
Erste Untersuchungsergebnisse an Sandstein, Tuffstein und Beton zeigen die Leistungsfähigkeit des neuen NMR-Tomographen zur Erfassung der porengrößenspezifischen Feuchteverteilung. In diesem Beitrag werden erste Ergebnisse verschiedenartiger Laborversuche exemplarisch dargestellt.
Für Sandsteine mit unterschiedlichsten Porengrößenverteilungen wurden mit dem neuen NMR-Tomographen und einem herkömmlichen NMR-System vergleichbare T2 Zeitenverteilungen ermittelt. Am sehr heterogenen Tuffstein konnten unterschiedlich poröse (und feuchte) Bereiche räumlich aufgelöst werden. Im Beton ließ sich der Feuchtetransport im Zementstein porengrößenspezifisch, schichtselektiv und zeitlich aufgelöst verfolgen.
Die bisher gewonnenen Ergebnisse zeigen das breite Anwendungsspektrum des neuen NMR Tomographen auf und ermöglichen ein besseres Verständnis des Feuchtetransports und der oft damit einhergehenden Schädigungsprozesse in Baustoffen.