Filtern
Erscheinungsjahr
- 2019 (360) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (135)
- Vortrag (123)
- Posterpräsentation (88)
- Sonstiges (6)
- Beitrag zu einem Tagungsband (2)
- Dissertation (2)
- Buchkapitel (1)
- Beitrag zu einem Sammelband (1)
- Forschungsbericht (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (308)
- Deutsch (50)
- Mehrsprachig (2)
Schlagworte
- Fluorescence (41)
- LIBS (21)
- Nanoparticle (21)
- Lifetime (19)
- Quantum yield (19)
- Dye (18)
- ICP-MS (15)
- Plasma modeling (13)
- Process Analytical Technology (13)
- Laser induced plasma (12)
- NIR (12)
- Online NMR Spectroscopy (11)
- Quantum dot (11)
- Sensor (11)
- Digitalisierung (10)
- Nanomaterial (10)
- Prozessindustrie (10)
- Quantum dots (10)
- Flow cytometry (9)
- Immunoassay (9)
- Isotope analysis (9)
- Laser ablation (9)
- Mass spectrometry (9)
- Plasma diagnostics (9)
- CONSENS (8)
- HR-CS-MAS (8)
- Magnesium (8)
- Nanoparticles (8)
- Optical spectroscopy (8)
- Photoluminescence (8)
- Reaction Monitoring (8)
- Cell (7)
- Lanthanide (7)
- Mechanism (7)
- Nano (7)
- Photophysics (7)
- Prozessanalytik (7)
- XRF (7)
- Calibration (6)
- Indium phosphide (6)
- Method (6)
- Spectroscopy (6)
- Surface chemistry (6)
- pH (6)
- AIS (5)
- Boden (5)
- Cr(III) complex (5)
- Datenanalyse (5)
- ELISA (5)
- Environment (5)
- Imaging (5)
- Industrie 4.0 (5)
- LA-ICP-MS (5)
- Multiplexing (5)
- Plasma (5)
- Process Industry (5)
- Raman spectroscopy (5)
- Smarte Sensoren (5)
- Temperature (5)
- qNMR (5)
- Assay (4)
- BODIPY (4)
- Bead (4)
- Catch and release assay (4)
- Chemometrics (4)
- Data Analysis (4)
- Delta value (4)
- Diclofenac (4)
- Electrochemistry (4)
- Encoding (4)
- Energy transfer (4)
- FITC (4)
- MIPs (4)
- Medical diagnostics (4)
- NMR (4)
- Nanosensor (4)
- Oxygen (4)
- PLSR (4)
- Ratiometric (4)
- SWIR (4)
- Single particle spectroscopy (4)
- Soil (4)
- Synthesis (4)
- Thermal anhydrite (4)
- Uncertainty (4)
- Upconversion nanoparticle (4)
- Warfarin (4)
- Absolute isotope ratio (3)
- Antikörper (3)
- Automation (3)
- Barcoding (3)
- Bead-based assay (3)
- Benchtop NMR (3)
- Bioconjugation (3)
- CCQM (3)
- CHO functions (3)
- Certified reference material (3)
- Comparability (3)
- Effect based Method (3)
- Estrogens (3)
- FTIR (3)
- Fluoreszenz (3)
- GC-MS (3)
- GDMS (3)
- Gadolinium (3)
- High-fired medieval gypsum mortars (3)
- ISO-Guide 35 (3)
- IgG (3)
- InP (3)
- Integrating sphere spectroscopy (3)
- Interlaboratory Comparison (3)
- Interlaboratory comparison (3)
- MC-ICP-MS (3)
- MOF (3)
- MS based method (3)
- Mass-Spectrometry (3)
- Microfluidics (3)
- Microplastics (3)
- Modular Production (3)
- Moisture (3)
- Mycotoxins (3)
- NMR-Spektroskopie (3)
- Nanomaterialien (3)
- Online NMR spectroscopy (3)
- Online-NMR-Spektroskopie (3)
- Optical quantification (3)
- PCA (3)
- Peptide library (3)
- Polymer particles (3)
- Process analytical technology (3)
- Protein G (3)
- Prozesskontrolle (3)
- Quality assurance (3)
- RFA (3)
- Raman microspectroscopy (3)
- Reference materials (3)
- Reliable measurements (3)
- SAFIA (3)
- SI traceability (3)
- Sensing (3)
- Single cell-ICP-ToF-MS (3)
- Transformationsprodukte (3)
- fluorescence (3)
- AIS QD (2)
- Absolute fluorometry (2)
- Accurate mass (2)
- Additive Manufacturing (2)
- Additive manufacturing (2)
- Advanced Materials (2)
- Amoxicillin (2)
- Analytical Sciences (2)
- Analytical methods (2)
- Antibody coating (2)
- Array (2)
- BFR (2)
- Bead-based-assay (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biochip (2)
- Biosensor (2)
- BonaRes (2)
- Boron (2)
- Breath alcohol analyser (2)
- CRM (2)
- Cancer (2)
- Carbamazepine (2)
- Chemical reactors (2)
- Chlorine (2)
- Cleavable probe (2)
- Compact NMR Spectroscopy (2)
- Compound annotation (2)
- Copper (2)
- Core−shell particles (2)
- Cytotoxicity (2)
- DFA (2)
- DNA origami (2)
- Datenvorbehandlung (2)
- Degradation (2)
- Delta values (2)
- Diatomic molecule (2)
- Diatoms (2)
- Digitale Transformation (2)
- Digitization (2)
- EMPIR (2)
- Electrospray ionization (2)
- Ergot (2)
- Extrahierbar organisch gebundenes Fluor (EOF) (2)
- FCM (2)
- Fatty acid metabolism (2)
- Flow Chemistry (2)
- Fluorine (2)
- Funtional Groups (2)
- Gallium doping (2)
- Gas chromatography (GC) (2)
- Grain size (2)
- Graphene (2)
- Gypsum dehydration (2)
- HR-CS-GFMAS (2)
- HRMS (2)
- Halogene (2)
- Hapten Immunoassay (2)
- Herceptin (2)
- High-fired gypsum mortar (2)
- High-resolution MS (2)
- IR (2)
- Immunocapture (2)
- Immunoglobulins (2)
- Immunoprecipitation (2)
- Immunosensor (2)
- Inline (2)
- Isotope dilution (2)
- Isotope dilution (ID) (2)
- Isotope ratio (2)
- LMD (2)
- Laser (2)
- Laser-induced plasma (2)
- Lipidomic profile (2)
- Liquid chromatography (LC) (2)
- Low-field NMR spectroscopy (2)
- MOSES (2)
- Mass Spectrometry (2)
- Mass spectrometry (MS) (2)
- Measurement uncertainty (2)
- Metabolic stress (2)
- Metrology (2)
- Microparticles (2)
- Modeling (2)
- Molecularly imprinted polymers (2)
- Multicellular spheroid (2)
- Multiplex (2)
- Multivariate data analysis (2)
- NMR Spectroscopy (2)
- Nanocrystal (2)
- Nontarget analysis (2)
- Nährstoffe (2)
- Oberflächengewässer (2)
- Online (2)
- Optical Spectroscopy (2)
- Oriented immobilization (2)
- PEG (2)
- PH (2)
- Performance validation (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Polymer (2)
- Probe (2)
- Process monitoring (2)
- Protein A (2)
- Proteins (2)
- Provenance (2)
- Proximity-enhanced reaction (2)
- Quantitative Analysis (2)
- Quantitative NMR Spectroscopy (2)
- Ringversuch (2)
- SERS (2)
- SHS (2)
- Schadstoffe (2)
- Screening (2)
- Semiconductor nanocrystal (2)
- Sensitization (2)
- Sensorik (2)
- Sialic acid (2)
- Single molecule (2)
- Speciation analysis (2)
- Sulfur (2)
- Surface (2)
- TFA (2)
- Ternary quantum dots (2)
- Thermography (2)
- Transformation product (2)
- Tumor metabolism (2)
- Umweltanalytik (2)
- Underwater LIBS (2)
- UpConversion (2)
- Upconversion (2)
- Upconversion nanoparticles (2)
- Vacuum-UV (2)
- Wastewater (2)
- Water Analysis (2)
- Water synthesis (2)
- ZRM (2)
- (Organisch gebundenes) Fluor-Summenparameter (1)
- 18HLT01 MetVes II (1)
- 5-bromouracil (1)
- 8-bromoadenine (1)
- ABID (1)
- AFB1 (1)
- Absolute measurement (1)
- Absolute quantum yield (1)
- Acoustic Emission (1)
- Acoustic levitation (1)
- Acoustical Levitation (1)
- Additive Fertigung (1)
- Adulteration (1)
- Affinity chromatography (1)
- Affinity enrichment (1)
- Affinitätschromatographie (1)
- Affinitätsextraktion (1)
- Affinty (1)
- Aflatoxins (1)
- Aggregates (1)
- Agricultural economy (1)
- Agriculture (1)
- Altenuene (1)
- Alternaria (1)
- Alternaria mycotoxins (1)
- Aluminium (1)
- Ambient Ionization (1)
- Ambient ionization (1)
- Ambient pressure laser ionization (1)
- Ameisensäure (1)
- Amorphous carbon (1)
- Analyseverfahren (1)
- Aneurism (1)
- Anhydrit (1)
- Anhydrite (1)
- Antibiotics (1)
- Antibodies (1)
- Antibody (1)
- Antifouling biocides (1)
- Antifouling surface (1)
- Antifouling-Biozide (1)
- Applied optical spectroscopy (1)
- Archean ocean (1)
- Artificial weathering (1)
- Atomic (1)
- Atomic force microscopy (1)
- Automated single cell-ICP-ToF-MS (1)
- Automated system (1)
- Autophagy (1)
- BERM (1)
- BODIPYs (1)
- BPA (1)
- Ball milling (1)
- Bead injection spectroscopy (1)
- Bead injections (1)
- Bead-based assays (1)
- Benchtop (1)
- Benzin (1)
- Binder (1)
- Bio-gated hybrid materials (1)
- Biogenic carbonates (1)
- Bioimaging (1)
- Biomarkers (1)
- Biosilicification (1)
- Blood (1)
- Boron isotope (1)
- Borosilicate glass (1)
- Borosilikatglas (1)
- Brightness (1)
- Bundesoberbehörden (1)
- C-C coupling (1)
- C3A (1)
- CE-ICP-MS (1)
- CF LIBS algorithms (1)
- CVD-Graphene (1)
- Caffeine (1)
- Calcification (1)
- Calibration beads (1)
- Calibration-free LIBS (1)
- Cancer cells (1)
- Capillary electrophoresis (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbon Nanodots (1)
- Carbon dot (1)
- Carriers (1)
- Catalysis (1)
- CdS shell (1)
- CdSe (1)
- Cellulose (1)
- Cement (1)
- Cement clinker remnants (1)
- Central Taurus (1)
- Characterization (1)
- Chemical coverage (1)
- Chemiluminescence (1)
- Chemometric (1)
- Chemometry (1)
- Chlor (1)
- Cleavable linker (1)
- Click chemistry (1)
- Clones (1)
- Cluster (1)
- Cobaloxime complex (1)
- Cocaine (1)
- Cocrystals (1)
- Collision induced dissociation (CID) (1)
- Combinatorial chemistry (1)
- Combinatorial polymer libraries (1)
- Combinatorial screening (1)
- Compact NMR spectroscopy (1)
- Compact spectrometers (1)
- Competitive Immunoassay (1)
- Complementary MS (1)
- Conductometry (1)
- Conjugates (1)
- Continuous processes (1)
- Core-shell structures (1)
- Core/shell quantum dot (1)
- Crosslinker (1)
- Crosslinking (1)
- Crude oil (1)
- Curcubituril (1)
- DFT (1)
- DNA (1)
- DNA-Sequence (1)
- DPA (1)
- DPSS-laser (1)
- Data Fusion (1)
- Data processing (1)
- Datenauswertung (1)
- Debromination (1)
- Defect photoluminescence (1)
- Degradation of refrigerants (1)
- Density functional calculations (1)
- Deoxynivalenol (1)
- Depht profiling (1)
- Diagnostic antibodies (1)
- Diatom (1)
- Diatomeenanalytik (1)
- Diatomic (1)
- Difluoressigsäure (1)
- Digital Twin (1)
- Digitaler Zwilling (1)
- Dip-stick assay (1)
- Dipole moment (1)
- Direct/indirect photolysis (1)
- Dissociative electron attachment (1)
- Dissolution (1)
- Distributed Networks (1)
- Dolomite (1)
- Double strands (1)
- Dried fig (1)
- Druckgasspeicher (1)
- Druckstabilität (1)
- Drug (1)
- Drug discovery (1)
- Dual sensing (1)
- Dye degradation (1)
- Dye labeling (1)
- EC/MS (1)
- EMPIR project (1)
- ESI MS (1)
- EURAMET (1)
- EXAFS (1)
- Ecotoxicological Assessment (1)
- Ecotoxicology testing (1)
- Education (1)
- Eingnugsprüfung (1)
- Elastin (1)
- Electrochemical (1)
- Electrochemical sensor (1)
- Electron transfer (1)
- Elektrochemie (1)
- Elemental Impurities (1)
- Elemental composition (1)
- Embedded sensor (1)
- Emerging brominated flame retardant (1)
- Energetic Materials (1)
- Energiespeicherung (1)
- Energy (1)
- Enhancement (1)
- Ensemble measurements (1)
- Environmental simulation (1)
- Environmental speciation (1)
- Epigenetics (1)
- Er(III) (1)
- Excimers (1)
- Excitation power density (1)
- Exciton (1)
- Explosionsschutz (1)
- Explosives determination (1)
- Extracellualr vesicles (1)
- Extracellular matrix (1)
- Extracellular vesicles (EV) (1)
- FLIM (1)
- FPIA (1)
- FPLC (1)
- FRET (1)
- False Positives (1)
- Fast flow GD (1)
- Fenton’s reagent (1)
- Ferumoxytol (1)
- Festphasenextraktion (1)
- Film (1)
- Fingerprint (1)
- Flow Cell (1)
- Flow Chemie (1)
- Fluorchlorkohlenwasserstoffe (1)
- Fluorescein (1)
- Fluorescence standard (1)
- Fluorescent label (1)
- Fluorierte Organische Verbindungen (1)
- Fluoroacetic acid (1)
- Fluorophores (1)
- Fluxomics (1)
- Food Safety (1)
- Food contaminants (1)
- Food fermentation (1)
- Food safety (1)
- Forschungsbedarf (1)
- Forschungsstrategie (1)
- Forsterite (1)
- Fragmentation activation (1)
- Fresenius (1)
- Fresenius Lecture (1)
- Fresenius lecture (1)
- Friction (1)
- Fully aromatic frameworks (1)
- Fusarium (1)
- GC-FID (1)
- GC-MS/MS (1)
- GDCh (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Gas analysis (1)
- Gas sensing (1)
- Gas-phase reactions (1)
- Gaschromatographie (1)
- Gaschromatography-Mass Spectrometry (1)
- Gasdetektion (1)
- Gasoline (1)
- Gassensorik (1)
- Genotoxicity testing (1)
- Geological thermometer (1)
- Germanium sulfide (1)
- Gips (1)
- Glasmonolith (1)
- Glasspeicher (1)
- Glue (1)
- Glycan (1)
- Gold nanoclusters (1)
- Graphite furnace (1)
- Gravimtric isotope mixtures (1)
- Ground water (1)
- Grundwasser (1)
- Gypsum (1)
- HPLC (1)
- HR-CS-AAS (1)
- HTS (1)
- Halogens (1)
- Heavy crude oil (1)
- Hexabenzocoronenes (1)
- High repetition-rate (1)
- High-fired gypsum (1)
- Hochauflösende Massenspektrometrie (1)
- Hochauflösende continuum source-Graphitrohr Molekülabosprtionsspektrometrie (HR-CS-GFMAS) (1)
- Hochauflösende-continuum source Graphitrohr Molekülabsorptionsspektrometrie (HR-CS-GFMAS) (1)
- Holographic microscopy (1)
- Host-guest interaction (1)
- Hot steam (1)
- Hot-electrons (1)
- Human antibodies (1)
- Human serum (1)
- Hybridoma (1)
- Hydration (1)
- Hydrazin (1)
- Hydrogenation (1)
- Hydrolysis (1)
- Hydrolysis products (1)
- Hydrolytic resistance (1)
- Hydrothermal fluid (1)
- Hydroxylation (1)
- Hyphenated (1)
- Hyphenated techniques (1)
- ICH guideline Q3D (1)
- IDMS (1)
- Iisotopic signature (1)
- Imaging Mass Cytometry (1)
- Imidazole (1)
- Immobilisierung (1)
- Immobilization (1)
- Immunglobulin (1)
- Immunoaffinity (1)
- Immunoaffinity extraction (1)
- In situ (1)
- In-vivo (1)
- Indirect Hard Modeling (1)
- Indirect hard modeling (1)
- Inflammation (1)
- Infrared Thermography (1)
- Inline NMR Spectroscopy (1)
- Integrated Processes (1)
- Integrating sphere spectroscopy, (1)
- Integration sphere spectroscopy (1)
- Interdisciplinary research (1)
- Interferences (1)
- Ion mobility spectrometry (1)
- Ionmobility spectrometry (1)
- Ionophore Antibiotika (1)
- Ionophore antibiotic (1)
- Iron isotope fractionation (1)
- Iron oxide (1)
- Isotope amount ratio (1)
- Isotope anaylsis (1)
- Isotope fractionation (1)
- Isotope purification (1)
- Isotope reference material (1)
- Isotope-labeled (1)
- Isotopic analysis (1)
- Isotopic fingerprints (1)
- Isotopic fractionation (1)
- Joung Analysts (1)
- Kapillarelektrophorese-Massenspektrometrie (1)
- Komplementäre Massenspektrometrie (1)
- Korrelationsmatrix (1)
- Künstliche Intelligenz (1)
- LC/HRMS (1)
- LFIA (1)
- LT-FCM (1)
- Lab-on-a-Chip (1)
- Lab-on-chip (1)
- Labeling (1)
- Labor 4.0 (1)
- Ladder sequencing (1)
- Lanthanide nanoparticle (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Laser induced breakdown (1)
- Laser metal deposition (1)
- Laser-Induced Background Spectroscopy (1)
- Lasers (1)
- Lateral Flow Immunoassay (1)
- Layers (1)
- Lead isotope composition (1)
- Lead isotope variations (1)
- Lead-free (1)
- Legionella (1)
- Lifetime, synthesis (1)
- Lifetime-encoding (1)
- Ligand (1)
- Lignin (1)
- Linear dynamic range (1)
- Lipid metabolism (1)
- Lipidomics (1)
- Liquid chromatography-mass spectrometry (1)
- Locked nucleic acids (1)
- Longst luminescence lifetime (1)
- Low-Energy (1)
- Low-field NMR Spectroscopy (1)
- Lysosome (1)
- MALDI (1)
- MALDI-TOF (1)
- MBA (1)
- MIP (1)
- MS-ICP-MS (1)
- Macrocyclus (1)
- Macrophage (1)
- Macrophages (1)
- Magnesium isotope ratios (1)
- Magnetic (1)
- Magnetic resonance imaging (1)
- Mangesium (1)
- Mass cytometry (1)
- Massenspektrometrie (1)
- Material Science (1)
- Matrix independent calibration (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Mechanochemistry (1)
- Medicinal plants (1)
- Mesofluidics (1)
- Messunsicherheit (1)
- Metabolomics (1)
- Metal sublimation (1)
- Metalloprotein (1)
- Metal–organic framework (1)
- Method comparison (1)
- Method development (1)
- Method validation (1)
- Methodenentwicklung (1)
- Methos comparision (1)
- Metrology in chemistry (1)
- Micro Reactor (1)
- Micro-Hydrocyclone (1)
- Micro-sublimation (1)
- Microarray (1)
- Microbeads (1)
- Microbially induced corrosion (1)
- Microemulsion (1)
- Microfluidic (1)
- Microfluidic Chip (1)
- Microparticle (1)
- Migration (1)
- Mikrofluidik (1)
- Mikromischer (1)
- Mikroplastik (1)
- Mineralölkohlenwasserstoffe (1)
- Mini-UAV (1)
- Mixed surface (1)
- Mmoisture (1)
- Modeling chemical reactions (1)
- Modelling (1)
- Modified mycotoxins (1)
- Molecular MRI (1)
- Molecular absorption spectrometry (1)
- Molecular spectrum (1)
- Molecularly Imprinted Polymers (1)
- Molecule (1)
- Monensin (1)
- Monoclonal Antibodies (1)
- Monoelemental solutions (1)
- Multicollector-ICP-MS (1)
- Multielemental analysis (1)
- Multielementanalytik in kurzen transienten Signalen (1)
- Multivariate (1)
- Multivariate Datenanalyse (1)
- Multivariate Datenauswertung (1)
- Multivariate analysis (1)
- Mycotoxin-Biomarker (1)
- NAMUR Open Architecture (1)
- NDT (1)
- NIR Spectroscopy (1)
- NIR Spektroskopie (1)
- NIR dyes (1)
- NMR Method Validation (1)
- NMR Spektroskopie (1)
- NOA (1)
- NSO-Heterozyklen (1)
- Nahinfrarotspektroskopie (1)
- Nanaoparticles (1)
- Nanocomposite (1)
- Nanohybrid (1)
- Nanolenses (1)
- Nanoparticle characterization (1)
- Nanoparticle dimers (1)
- Nanoparticle formation (1)
- Nanosciences (1)
- Nanostructures (1)
- Nanotechnologie (1)
- Naphthalene (Nap) (1)
- Nd excitation (1)
- Near-infrared (1)
- Neuartige Materialien (1)
- Next Generation Sequencing (1)
- Nichtmetall-Analytik (1)
- Nichtmetalle (1)
- Niederfeld-NMR-Spektroskopie (1)
- Niobcarbid (1)
- Nnanoparticle (1)
- Non-metal analysis (1)
- Non-metals analysis (1)
- Nontargeted approach (1)
- OBOC (1)
- Old nanocrystal (1)
- Oligonucleotide fragmentation (1)
- Oligonucleotides (1)
- Online fluorescence (1)
- Online-NMR spectroscopy (1)
- Online-Referenzmethode (1)
- Optical Emission Spectroscopy (1)
- Optical assay (1)
- Optical emission spectroscopy (1)
- Optical properties (1)
- Ore provenance (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Organic–inorganic nanostructures (1)
- Origami (1)
- Oxidative metabolism (1)
- Oxygen sensitive (1)
- PANIC (1)
- PAT (1)
- PBFSM (1)
- PDT (1)
- Paint (1)
- Pentaphenes (1)
- Peptide (1)
- Peptide Library (1)
- Peptide mass fingerprinting (1)
- Peptides (1)
- Perovskite (1)
- Pesticide (1)
- Pflanzenwachstum (1)
- Phage Display (1)
- Pharmaceutical (1)
- Pharmacopoeial Reference Standards (1)
- Phosphinine (1)
- Photo-transformation products (1)
- Photocatalyst (1)
- Photocatalytic reduction (1)
- Photochemistry (1)
- Photoluminescence quantum yield (1)
- Photooxidation (1)
- Photostability (1)
- Phytoliths (1)
- Plant tissue (1)
- Plasma chemical reactor (1)
- Plasma enhanced chemical vapor deposition (1)
- Plasma physics (1)
- Plasmaspectrochemistry (1)
- Plasmonic heating (1)
- Plastic (1)
- Pollutants (1)
- Polyethylene Glycol (1)
- Polyethylene glycol (1)
- Polymer particle (1)
- Polymers (1)
- Polyurethane (1)
- Pore fluids (1)
- Porosity (1)
- Porphyrin (1)
- Powder X-ray diffraction (1)
- Power-to-Gas (1)
- Pozessindustrie (1)
- Precision polymer sequencing (1)
- Priam's treasure (1)
- Primäre Kalibriersubstanzen (1)
- Principal component analysis (PCA) (1)
- Process industry (1)
- Proficiency Testing (1)
- Protein g (1)
- Prozess-Sensoren 4.0 (1)
- Prozesslabor (1)
- Pseudo peptides (1)
- Pseudomonas fluorescens (1)
- Pulsed-GD-SFMS (1)
- Pyrolysis (1)
- Quality Management (1)
- Quality assurcance (1)
- Qualitätskontrolle (1)
- Quantification (1)
- Quantum yield standard (1)
- Quantum yields (1)
- Quinones (1)
- R package (1)
- Radiogenic isotopes (1)
- Rainwater (1)
- Raman (1)
- Raman band width (1)
- Raman band width determination (1)
- Raman microscopy (1)
- Raman-Spektroskopie (1)
- Raman-spectroscopy (1)
- Ramanspektroskopie (1)
- Rapid test (1)
- Reaktionsmonitoring (1)
- Real-time imaging (1)
- Real-time process monitoring (1)
- Real-time quality control (1)
- Reference Material (1)
- Reference material (1)
- Reference methods (1)
- Reference particles (1)
- Referenzmaterial (1)
- Referenzmaterial-Herstellung (1)
- Referenzmaterialien (1)
- Regeneration (1)
- Reinstmetalle (1)
- Reinststoffe (1)
- Reverse microemulsion (1)
- Rhizopus and Aspergillus oryzae (1)
- Risikoanalyse (1)
- SC-ICP-MS (1)
- SDS-PAGE (1)
- SI Traceability (1)
- SI-traceability (1)
- SI-traceable (1)
- SIDA-LC-MS/MS (1)
- SMASH (1)
- SWIR photoluminescence (1)
- Safe by design (1)
- Salicylic acid (1)
- Salts (1)
- Sample-sample bracketing (1)
- Saure Hydrolyse (1)
- Scattering (1)
- Schnelltest (1)
- Schwangerschaftstest (1)
- Scientific communication (1)
- Scientific method (1)
- Scientific rigour (1)
- Self-assembly (1)
- Semiconductor (1)
- Sensitizers (1)
- Sequence-defined oligomer (1)
- Sequencing (1)
- Serum (1)
- Shape (1)
- Shell (1)
- Si isotope fractionation (1)
- Signal amplification (1)
- Silane (1)
- Silica (1)
- Silica coating (1)
- Silver indium sulfide (1)
- Simultaneous determination (1)
- Single cell-ICP-MS (1)
- Single particle-ICP-ToF-MS (1)
- Single-dot spectroscopy (1)
- Single-particle measurements (1)
- Singlet oxygen (1)
- Size (1)
- Small-angle scattering (1)
- Smarte Aktoren (1)
- Smarte Laborgeräte (1)
- Software (1)
- Solid state (1)
- Solid state NMR (1)
- Solid-state fluorescence (1)
- Solubilizer (1)
- Sonochemical synthesis (1)
- Sorghum (1)
- Spatial Heterodyne Spectrometer (1)
- Spatial Heterodyne Spectroscopy (1)
- Spatial heterodyne spectrometer (1)
- Spatial heterodyne spectroscopy (1)
- Spectroscopic imaging (1)
- Speiseöle (1)
- Speroid (1)
- Spheroid (1)
- SsNMR (1)
- Stabilization (1)
- Standardization (1)
- Static Mixing (1)
- Stepwise growth (1)
- Sulfide sensing (1)
- Summenparameter Fluor (1)
- Summer School (1)
- Superplasticizer (1)
- Supramolecular chemistry (1)
- Surface Chemistry (1)
- Surface analysis (1)
- Surface group (1)
- Surface group analysis (1)
- Surface group quantification (1)
- Surface-enhanced Raman scattering (1)
- Surfaces (1)
- Suspension Array (1)
- Suzuki coupling (1)
- Suzuki-Miyaura coupling (1)
- Switch (1)
- Synchrotron FTIR (1)
- TGA-FTIR (1)
- TTBP-TAZ (1)
- Tandem MS (1)
- Target (1)
- Teaching (1)
- Tenuazonic acid (1)
- Terbutryne (1)
- Ternary quantum dot (1)
- Test strips (1)
- Teststreifen (1)
- Theory (1)
- Therapeutic Drug Monitoring (1)
- Therapeutic antibodies (1)
- Thermal decomposition (1)
- Thermographie (1)
- Thick shells (1)
- Thin film (1)
- Time-gated emission (1)
- Time-resolved (1)
- Time-resolved flow cytometry (1)
- Titan-Halterung (1)
- Toxicity (1)
- Transformation Products (1)
- Transformation products (1)
- Transformations products (1)
- Trastuzumab (1)
- Trialkoxysilane (1)
- Triazine herbicide (1)
- Tribofilm (1)
- Tribologie (1)
- Trichodiene (1)
- Trifluoressigsäure (1)
- Trinitro (1)
- Triple isotope fractionation (1)
- Triplet-triplet annihilation (1)
- Trojan silver artefacts (1)
- UV Vis (1)
- UV irradiation (1)
- UiO (1)
- Ultrasound (1)
- Umwelt-Speziation (1)
- Umweltsimulation (1)
- Umweltverhalten (1)
- Uncertainty Evaluation (1)
- Upconverstion (1)
- Vacuum ultraviolet (VUV) light (1)
- Validation trial (1)
- Validierung (1)
- Vanadiumcarbid (1)
- Vernetzung (1)
- Veterinary drugs (1)
- Wasser (1)
- Wasserstoff (1)
- Wasserstofferzeugung (1)
- Water (1)
- Wear (1)
- Weighing Uncertainty (1)
- Wolframcarbid (1)
- Work function (1)
- X-ray microspectroscopy (1)
- XRD (1)
- Yb(III) (1)
- Yb(III) complex (1)
- Yerba mate tea (1)
- Zearalenone sulfate (1)
- Zellulose (1)
- Zirconia (1)
- Zn (1)
- a-zearalenol (1)
- agricultural economy (1)
- anion-exchange (1)
- antibody (1)
- bacteria (1)
- bacteria detection (1)
- bell pepper (1)
- biokompatibel (1)
- boron (1)
- delta value (1)
- embedded sensor (1)
- environment (1)
- flow cytometry (1)
- fluorescence microscopy (1)
- gas analysis (1)
- gesintert (1)
- imaging (1)
- immunoseparation (1)
- ion optics (1)
- isotope fractionation (1)
- lifetime (1)
- magnetic nanoparticle (1)
- measurement uncertainty (1)
- metabolism (1)
- method (1)
- nanoparticle (1)
- pH sensor (1)
- particle (1)
- quantum dot (1)
- quantum yield (1)
- screening tes (1)
- single cell-ICP-ToF-MS (1)
- single particle-ICP-ToF-MS (1)
- spectroscopy (1)
- µJ-DPSS laser (1)
- γ-H2AX assay (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (360) (entfernen)
Eingeladener Vortrag
- nein (123)
Metabolomics, the analysis of potentially all small molecules within a biological system, has become a valuable tool for biomarker identification and the elucidation of biological processes. While metabolites are often present in complex mixtures at extremely different concentrations, the dynamic range of available analytical methods to capture this variance is generally limited. Here, we show that gas chromatography coupled to atmospheric pressure chemical ionization mass spectrometry (GC-APCI-MS), a state of the art analytical technology applied in metabolomics analyses, shows an average linear range (LR) of 2.39 orders of magnitude for a set of 62 metabolites from a representative compound mixture. We further developed a computational tool to extend this dynamic range on average by more than 1 order of magnitude, demonstrated with a dilution series of the compound mixture, using robust and automatic reconstruction of intensity values exceeding the detection limit. The tool is freely available as an R package (CorrectOverloadedPeaks) from CRAN (https://cran.r-project.org/) and can be incorporated in a metabolomics data processing pipeline facilitating large screening assays.
Die neue Crosslinking-Methode ist hilfreich, um Immunglobuline des Isotyps G ortspezifisch an ihrer Bindungsstelle mit Protein A oder G zu konjugieren. Die Kopplungen von Protein A und G konnten erfolgreich an Maus- und Human-IgG durchgeführt, sowie die Bedingungen untersucht und optimiert werden. Die Aktivierung von Protein G mit Glutaraldehyd erfolgt am besten bei pH 8 und die anschließende Kopplung mit Maus-IgG1 bei einem pH-Wert von 6. Jedoch wurden mit SIAB und Sulfo-SIAB als Crosslinker im Vergleich zu Glutaraldehyd noch höhere Signale erhalten. Für die Kopplung von SIAB sind 40% DMSO im Reaktionspuffer günstig, währenddessen Sulfo-SIAB gut wasserlöslich ist daher keine Lösungsvermittler benötigt. Es ergab sich ein optimaler pH-Wert von 7,4 um Protein A mit SIAB zu aktivieren und den gleichen pH-Wert um die Kopplung mit Maus-IgG1 durchzuführen. Für die Kopplung von Protein G mit Maus-IgG1 hingegen zeigten die Experimente, dass ein leicht saurer pH-Wert bei pH 6 für den IgG-Kopplungsschritt am günstigsten ist. Während die Inkubationszeit von Maus-IgG1 mit Protein G bei 16 h liegt, muss mit Protein A bis zu 40 h inkubiert werden, um das Kopplungsmaximum zu erreichen. Des Weiteren wurde das Crosslinking von Human-IgG (Herceptin) mit SIAB untersucht. Dabei zeigte sich, wie in der Abbildung 47 zu sehen ist, dass Protein A und G vergleichbar gut an Human-IgG zu koppeln sind. Für das Crosslinking von Protein G mit Maus-IgG1 ist dagegen ein deutlich besserer Umsatz im Vergleich zu Protein A zu erkennen (Abbildung 48). Heterobifunktionale Linker können mit der reaktiveren Gruppe die erste Bindung eingehen, um erst nach Zugabe eines weiteren Reagenzes die zweite Bindung auszubilden und zudem intramolekulare Reaktionen möglichst zu vermeiden.
Im Vergleich zu anderen Proteinen ist die Identifizierung von Antikörpern anhand ihrer Sequenz zum Beispiel mittels "peptide mass fingerprinting" schwierig. Da die Sequenzinformation eines Antikörpers aufgrund der hypersomatischen Mutation während der Affinitätsreifung nicht im Genom eines Organismus gespeichert ist, kann die Aminosäuresequenz nicht auf einfachem Weg der DNA-Sequenzierung gewonnen werden. Das ist nur in seltenen Fällen möglich, wenn dem Endanwender der Zellklon der Antikörper-produzierenden Zelle zugänglich ist. Eine Sequenzierung auf Protein-Ebene ist sehr aufwändig und teuer und wird daher fast nie für die Charakterisierung von analytischen Antikörpern verwendet. Der Mangel an Validierung dieser analytischen Antikörper, die bei Experimenten verwendeten werden, löst aber eine Reihe Probleme aus, die die Wiederholbarkeit dieser Experimente schwierig und in einigen Fällen unmöglich macht. Das sorgt jährlich für verschwendete Forschungsgelder in Milliardenhöhe und hindert den wissenschaftlichen Fortschritt.
Ziel der vorliegenden Arbeit war die Entwicklung einer einfachen und schnellen Methode, die es trotzdem ermöglicht, die Identifikation von Antikörpern sicherzustellen. Dazu wurde eine Methode basierend auf dem "peptide mass fingerprinting" gewählt. Das Problem der unbekannten Aminosäuresequenz der Antikörper wurde gelöst, indem lediglich die Peptidmuster der entstehenden Fingerprint-Spektren zur Identifikation herangezogen wurden. MALDI wurde dabei als Ionisationsmethode für die Massenspektrometrie gewählt, da die resultierenden Spektren im Gegensatz zu ESI-MS einfach auszuwerten sind. Auch kann auf eine vorige Trennung der Peptide mittels LC verzichtet werden, was zusätzlich Analysenzeit spart. Für die Proteinspaltung wurde eine simple saure Hydrolyse mittels Ameisensäure gewählt. Im Vergleich zum herkömmlichen Trypsin-Verdau konnten auf zeitraubende Arbeitsschritte wie Denaturierung, Reduktion und Alkylierung der Antikörper verzichtet werden. Die Hydrolyse mittels Ameisensäure wurde bisher nur auf kleine und mittelgroße Proteine angewendet, sodass im ersten Teil dieser Arbeit mehrere Schritte optimiert wurden bevor zufriedenstellende Fingerprint-Spektren von Antikörpern erhalten wurden.
The high ionization potentials and low wavelength emission lines of halogens difficult the analysis of their organohalogen compounds by ICP-based methods [1]. Other techniques, such as combustion ion chromatography (CIC) or ion-selective electrodes have proven to be more reliable to determine these elements. However, these techniques are more time-consuming and/or have lower precision and accuracy.
High resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS) allows the determination of solid and liquid samples by monitoring a molecule formed with the analyte and a molecule forming reagent. In the case of F, Cl and Br, several molecule forming agents have been studied for their determination. Among all of them, calcium can form a stable bond with the three elements and provides optimal analytical properties for trace analysis [2]. However, the spectral window of commercially available continuum source AAS instruments is not broad enough to cover the wavelength range necessary for a simultaneous determination. Thus, coupling it with a modular simultaneous echelle spectrograph (MOSES), which can register around 200 nm in a single measure, allows the simultaneous study of the three analytes [3].
This instrumentation is capable of register more than 200 nm of the spectra per measure keeping a high resolution. This spectral window is suitable for the monitorization of a variety of transitions of the three molecules. However, some of them are overlapped and the competitive mechanism of formation of the three molecules modify their sensitivity depending on the proportions in the sample.
In this study, a compromise in the conditions and modifiers were selected in order to maximize the sensitivity and signal to noise ratio for the three molecules. The determination was carried out by standard addition of CaF and Cl and Br were obtained from the PLS model.
References:
[1] X. Bu, T. Wang, G. Hall, J. Anal. At. Spectrom., 18, 1443–1451 (2003)
[2] M. Resano, E. García-Ruiz, M. Aramendía, M. A. Belarra, J. Anal. At. Spectrom., 34, 59–80 (2019)
[3] S. Geisler, M. Okruss, H. Becker-Ross, M. Dong Huang, N. Esser, S. Florek, Spectrochimica Acta PartB, 107, 11–16 (2015)
Binder remnants in historical mortars represent a record of the connection between the raw materials that enter the kiln, the process parameters, and the end product of the calcination. Raman microspectroscopy combines high structural sensitivity with micrometre to sub-micrometre spatial resolution and compatibility with conventional thin-sectional samples in an almost unique fashion, making it an interesting complementary extension of the existing methodological arsenal for mortar analysis. Raman spectra are vibrational fingerprints of crystalline and amorphous compounds, and contain marker bands that are specific for minerals and their polymorphic forms. Relative intensities of bands that are related to the same crystalline species change according to crystal orientations, and band shifts can be caused by the incorporation of foreign ions into crystal lattices, as well as stoichiometric changes within solid solution series. Finally, variations in crystallinity affect band widths. These effects are demonstrated based on the analysis of three historical mortar samples: micrometric distribution maps of phases and polymorphs, crystal orientations, and compositional variations of solid solution series of unreacted clinker grains in the Portland cement mortars of two 19th century castings, and the crystallinities of thermal anhydrite clusters in a high-fired medieval gypsum mortar as a measure for the applied burning temperature were successfully acquired.
In the last years, the Process Analytical Technology (PAT) research field has become of great importance due to its connection with the industrial world. This industry related research, along with the evolutionary progress that technology has seen lately, has allowed that key analytical techniques in an industrial environment have undergone a radical development. One of these techniques has been the near-infrared spectroscopy (NIRS). This technique, currently common in "online" industrial analysis, has seen a remarkable revolution, especially since the introduction of the microelectromechanical systems technology (MEMS) in the spectroscopy field. Nowadays it is possible to find compact spectrometers no bigger than a wristwatch in the market. Although there is an unavoidable question: can these compact spectrometers actually compete against the traditional spectrometers?
In this project different calibration parameters of two compact NIR spectrometers ("Spectral Engines Oy NIR-One Sensor NM2.0", with 1550 to 1950 nm range; and "NeoSpectra Si-ware", with 1300 to 2550 nm range) were evaluated, and the obtained results were compared with a reference spectrometer ("Bruker Optik GmbH Matrix-F", with 15000 to 4000 cm–1 range). In order to obtain the different calibration parameters, a sequence of quality performance tests were conducted. The results obtained after the different experiments carried out with both compact spectrometers prove that their performance is more than acceptable for routine analysis.
Afterward, model samples of different microplastics in soil at different known concentration were analyzed with all three spectrometers. Chemometric models capable to identify and classify microplastics in soil were established. For this analysis five of the most used plastics worldwide were used: polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), and polyvinyl chloride (PVC). After the Principal component analysis (PCA), it can be seen that only the NIR-One NM2.0 is capable to differentiate all types of microplastics in soil at concentrations of 1–2 %, while the NeoSpectra Si-ware is unable to identify the PET sample.
Eu2+ is used to replace toxic Pb2+ in metal halide perovskite nanocrystals (NCs). The synthesis implies injection of cesium oleate into a solution of europium (II) bromide at an experimentally determined optimum temperature of 130 ○C and a reaction time of 60 s. Structural analysis indicates the formation of spherical CsEuBr3 nanoparticles with a mean size of 43 ± 7 nm. Using EuI2 instead of EuBr2 leads to the formation of 18-nm CsI nanoparticles, while EuCl2 does not show any reaction with cesium oleate forming 80-nm EuCl2 nanoparticles.
The obtained CsEuBr3 NCs exhibit bright blue emission at 413 nm (FWHM 30 nm) with a room temperature photoluminescence quantum yield of 39%. The emission originates from the Laporte-allowed 4f7–4f65d1 transition of Eu2+ and shows a PL decay time of 263 ns.
The long-term stability of the optical properties is observed, making inorganic lead-free CsEuBr3 NCs promising deep blue emitters for optoelectronics.
The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones.
Singlet oxygen can severely damage biological tissue, which is exploited in photodynamic therapy (PDT). In PDT, the effective range is limited by the distribution of the photosensitizer (PS) and the illuminated area. However, no distinction is made between healthy and pathological tissue, which can cause undesired damage. This encouraged us to exploit the more acidic pH of cancerous tissue and design pH-controllable singlet oxygen-generating boron-dipyrromethene (BODIPY) dyes. A pH sensitivity of the dyes is achieved by the introduction of an electronically decoupled, photoinduced electron transfer (PET)-capable subunit in meso-position of the BODIPY core. To favor triplet-state formation as required for singlet Oxygen generation, iodine substituents were introduced at the chromophore core. The resulting pH-controlled singlet oxygen-generating dyes with pKa values in the physiological range were subsequently assessed regarding their potential as pH-controlled PS for PDT.
Using HeLa cells, we could successfully demonstrate markedly different pH-dependent cytotoxicities upon illumination.
Extracellular vesicles (EV) are cell-derived particles in body fluids, which have excellent potential as next-generation biomarkers. The exploitation of EV requires reliable measurements, which is currently very difficult, as most EV are smaller than 200 nm. At present, flow cytometry (FCM) is the most appropriate technique for EV analysis in biological samples, as FCM is readily available in many clinical laboratories and allows to identify cell-specific EV at high throughput. However, due to technical variations between different FCM instruments, EV concentration measurements are currently not well comparable between most laboratories. Therefore, EV reference materials and standardized reference methods are urgently needed to calibrate flow rate, light scattering intensity, and fluorescence intensity of FCM in the sub-micrometer size range. This requires a better matching of the optical properties of calibration beads and EV as can be realized with current polystyrene calibration beads.
The EMPIR project 18HLT01 “MetVes II” aims to develop synthetic reference materials and traceable measurement methods to standardize EV measurements. The reference materials should resemble EV properties, so that calibrations are reliable and do not require a change of acquisition settings. Hence, the reference materials should contain particles with a traceable number concentration in the range of 109–1012 particles/mL to calibrate flow rate, a traceable size with discrete diameters between 50–1000 nm and a refractive index (RI) in the range of 1.37–1.42 to calibrate scattering intensity, and a traceable fluorescence intensity between 100–100,000 molecules of equivalent soluble fluorochromes (MESF). At BAM, various approaches to prepare such low-RI nanometer-sized reference materials will be studied, preliminary results of the primary characterization of these candidate reference particles will be presented, and possible applications besides FCM-based EV detection will be outlined.