Filtern
Erscheinungsjahr
- 2019 (83) (entfernen)
Dokumenttyp
- Posterpräsentation (83) (entfernen)
Sprache
- Englisch (83) (entfernen)
Referierte Publikation
- nein (83)
Schlagworte
- Fluorescence (12)
- Flow cytometry (7)
- LIBS (7)
- Dye (6)
- Immunoassay (5)
- ICP-MS (4)
- Laser induced plasma (4)
- Lifetime (4)
- Nanoparticle (4)
- Plasma modeling (4)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (83) (entfernen)
The elemental analysis of seawater is often critical to the understanding of marine chemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdown spectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a great potential for in-situ elemental analysis of seawater. In practice, it is crucial to create a compact, low cost and power saving instrument for the long-term deep-sea observation. A recently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidate as it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHz can provide a considerable throughput for LIBS analysis. However, the DPSS lasers operate at moderate pulse energies, usually less than one mJ, which cannot sustain stable breakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such a μJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. The phase interface and mass flow generated by the near-field ultrasound can greatly reduce the breakdown threshold and enhance element-specific emissions. Meanwhile, the high repetition-rate pulses can also improve the breakdown probability and generate unique emission lines originated from the water molecule. We further demonstrate that the high repetition-rate DPSS laser combined with the Echelle spectrometer can provide effective quantitative analysis for metal elements in bulk water.
The elemental analysis of seawater is often critical to the understanding of marinechemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdownspectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a greatpotential for in-situ elemental analysis of seawater. In practice, it is crucial to create acompact, low cost and power saving instrument for the long-term deep-sea observation. Arecently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidateas it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHzcan provide a considerable throughput for LIBS analysis. However, the DPSS lasers operateat moderate pulse energies, usually less than one mJ, which cannot sustain stablebreakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such aμJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. Thephase interface and mass flow generated by the near-field ultrasound can greatly reduce thebreakdown threshold and enhance element-specific emissions. Meanwhile, the highrepetition-rate pulses can also improve the breakdown probability and generate uniqueemission lines originated from the water molecule. We further demonstrate that the highrepetition-rate DPSS laser combined with the Echelle spectrometer can provide effectivequantitative analysis for metal elements in bulk water.
Non-linear optical emitters are promising materials for energy applications and biotechnologies. Solid-state multi-band emitters like lanthanide doped up-conversion nanoparticles (UCNPs) show excellent photostability, are excitable in the near infrared (NIR), and show emission bands from the UV to SWIR spectral regions. The optical properties of these materials strongly depend on the excitation power density, i.e., the number of photons absorbed per time interval. The upconversion (ΦUC) and downshifting quantum efficiencies (ΦDS) of these materials, the excitation power dependent population, and the deactivation dynamics are influenced by nanoparticle architecture, doping concentration, and the microenvironment. We studied the fundamental changes of the luminescence properties of ß-NaYF4 UCNPs doped with Yb3+ and Er3+ depending on size, different surroundings such as aqueous and organic media, and different surface chemistries. We obtained further insights into shelling procedures, FRET optimization, influence of doping concentration, and advantages of different sensitizer ions.
Elemental impurities (EI) in medicinal products for human use are limited according to ICH guideline Q3D, which is in force since December 2017 in Europe and US.
As a consequenceconsequence, the relevant texts of the European Pharmacopoeia (Ph. Eur.) and the United States Pharmacopeia (USP) have been modified to reflect and complement ICH Q3D, providing details on the analytical methods to be used. In those chapters (Ph. Eur. 2.4.20., USP <233>), it is stated that for the quantification of elemental impurities, certified reference materials (CRM) from a national metrology institute (NMI) or reference materials that are traceable to the CRM of an NMI should be used.
The Ph. Eur. has so far implemented elemental impurity standards of this type for the four most important elemental impurities i.e. those corresponding to ICH Q3D Class 1: lead, cadmium, mercury and arsenic.
The poster provides details on the development of those four reference standards, which was undertaken in partnership with a major institute accredited CRM producer (JRC, European Commission), and a national metrology institute (BAM and PTB, Germany), and a Designated Institute and accredited CRM producer (BAM, Germany). The reference standards were established and characterised according to rigorous metrological principles and are supplied with extended supporting information as required for the intended use.
After successful completion of the project, the four reference standards have been added to the Ph.Eur. catalogue and are in distribution. It is expected that another three elemental impurity standards will be implemented and made available to users within the next three years.
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pHsensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
In summary, by combining the NIR-emissive [Cr(ddpd)2][BPh4]3 complex CrBPh4 with its extremely large energy gap between the longest wavelength absorption and emission maxima with a pH-responsive fluorescein derivative (FITC) and an inert reference dye like Nile Red (NR) and 5,10,15,20tetrakis(pentafluorophenyl) porphyrin (TFPP), we developed nanosensors for simultaneously sensing temperature, O2 partial pressure, and pH. These novel TOP nanosensors (temperature, oxygen, pH) cover the biologically and physiologically relevant concentration ranges of these parameters/analytes with single wavelength excitation in PBS buffer and in a cell culture medium containing bovine serum albumin (BSA). The response of both nanosensors to all parameters is fully reversible and only minimally affected by the presence of BSA, the most common serum albumin. Moreover, comparative studies with nanosensors containing only a single type of stimuli-responsive molecule and with the respective molecular systems revealed that the different sensor components do not interfere with each other. Future research will include the testing of these nanosensors in cellular uptake studies and, after surface modification with targeted bioligands, eventually in in vivo experiments as previously done by some of us with other polystyrene nanoparticle reporters and nanosensors.46,47 Moreover, this concept of multianalyte sensing will be expanded to nanosensors derived from differently sized premanufactured biocompatible polymer particles and different stimuli-responsive dyes like fluorescent indicators for biologically and bioanalytically relevant metal ions.
Working towards a comprehensive understanding of introduction pathways, number, and fate of micro¬plastics in the environment, suitable analytical methods are a precondition. Micro-spectroscopic methods are probably the most widely used techniques. Besides their ability to measure single spectra of a particle or fiber, most modern FTIR- and Raman microscopes are also capable of two-dimensional imaging. This is very appealing to microplastics research because it allows to simultaneously characterize the analytes chemically as well as their size (distribution) and shape.
Two-dimensional imaging on extensive sample areas with FTIR-micros¬copes is facilitated by focal plane array (FPA) detectors resulting in large data sets comprised of up to several million spectra. With numbers too large for manual inspection of each individual spectrum, automated data evaluation is inevitable. Identifying different polymers based on the comparison with known reference spectra (library search) has proven to be a suitable approach. For that purpose, FTIR-spectra of common plastics can be collected to create an individual reference library.
To Supplement this ‘targeted analysis’, looking for known substances via library search, an exploratory approach was tested. Principal component analysis (PCA) proved to be a helpful tool to drastically reduce the size of the data set while maintaining the significant information. Subsequently, cluster analysis was used to find groups of similar spectra. Spectra found in different clusters could be assigned to different polymer types. The variation observed within clusters gives a hint on chemical variability of microplastics of the same polymer found in the sample. Spectra labeled according to the respective cluster/polymer type were used to build a classification model which allowed to quickly predict the polymer type based on the FTIR spectrum. Classification was tested on a second, independent data set and results were compared to the spectral library search procedure.
In this study, we developed a new immunoprecipitation method based on protein-coated nanodiamonds. Performing SDS-PAGE and using the SDS-PAGE buffer as an eluent showed that CER could be successfully enriched from human serum. Based on the copper determination with ICP-MS, the amount of bound CER on the nanodiamonds can be calculated. We could show the fulfilled mass balance of bound CER and CER in the supernatant after incubation with a known amount of CER. For isotope ratio analysis this method can be applied to compare ratios of the total copper content in human serum to copper ratios from CER enrichment.
Herein, we present the development of a gas chromatographic method for Determination of warfarin, its TPs, and selected metabolites.
TPs were formed by applying UV-irradiation, ozonation, and an electrochemical cell coupled to mass spectrometry to mimic the oxidative phase I metabolism. The further aim is to use this method for detection and quantification under environmentally relevant conditions, as well as, toxicological assessment.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144 and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. We could achieve for the first time measurement uncertainties for isotope amount ratios close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level (2SD). In addition, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multi-collector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ to 0.7 ‰.
With these isotope reference materials, it is possible to establish SI-traceability for magnesium delta measurements. To realize this, we organized a second study within which five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for δ26/24Mg determinations (2SD). Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.