Filtern
Erscheinungsjahr
- 2019 (6) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (3)
- Vortrag (2)
- Beitrag zu einem Tagungsband (1)
Sprache
- Englisch (6) (entfernen)
Schlagworte
- Explosionsgrenzen (3)
- Kältemittel (3)
- Chemisch instabile Gase (2)
- Zündenergie (2)
- Zündquellen (2)
- Acetone (1)
- Alcohols (1)
- CAFTP (1)
- CNG (1)
- Composite cylinder (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (6)
- 2.1 Sicherheit von Energieträgern (6)
- 2.2 Prozesssimulation (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.0 Abteilungsleitung und andere (1)
- 7 Bauwerkssicherheit (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
Eingeladener Vortrag
- nein (2)
Explosion and decomposition limits of flammable and chemically unstable gases were determined experimentally in a closed autoclave with an ignition energy higher than the standard 10 J a 20 J. The ignition source was a lightning arc caused by an exploding wire igniter as described in EN 1839 B. With a newly developed ignition system a graded ignition energy between 3 J and 1000 J was generated. Different types of gases were studied with this ignition system: methane as a typical fuel gas and reference gas for some standards for explosion limit determination, the refrigerant R32 (difluoromethane) as a mildly flammable gas with low burning velocity and high minimum ignition energy compared with methane as well as the chemical unstable gases acetylene, nitrous oxide and ethylene oxide, which can decompose explosively in the absence of air or other oxidizers. It was found that the influence of strong ignition sources on explosion and decomposition limits can be very different for different systems. In case of methane only the upper explosion limit was influenced significantly by the ignition energy, whereas the lower explosion limit was constant. In a standard test vessel with an inner volume of 14 dm3 it was difficult to quantify the upper explosion limit of methane exactly with the strong ignition source, because the explosion pressure did not increase abruptly near the explosion limit, but steadily over a large concentration range. Probably a larger explosion vessel is more appropriate in this case. In case of R32 however, it was the lower explosion limit that was influenced significantly by the ignition energy and not the upper explosion limit. A particularly strong dependency from the ignition energy was found for the decomposition limits of the chemically unstable gases in nitrogen. Here special regard is necessary in practical applications, if uncommonly strong ignition sources cannot be excluded.
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP, like R134a, are flammable. For evaluating inertization measures for explosion protection, flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide, nitrogen and argon were studied experimentally in a closed autoclave at atmospheric conditions. Furthermore, a calculation method was adapted to reduce the experimental costs for flammability studies on these gas mixtures. For igniting R1234yf in the closed autoclave a newly developed ignition system was used that allows generating electric arcs with high ignition energy. Gas mixtures containing the mildly flammable R1234yf and R32 could be inerted by adding much less inert gas than mixtures containing R1132a, which is more similar to unfluorinated hydrocarbons regarding the explosion regions. By using the adapted model of constant adiabatic flame temperature profiles estimating the explosion limits of fluorinated hydrocarbons was possible with similar accuracy as for unfluorinated hydrocarbons.
Keywords: Explosion Protection, Inertization, Flammability, HFOs, HFC., R1234yf, R32, R1132a
The explosion regions of 1-propanol, 2-propanol, acetone and 1-butanol in air were measured in the presence of CO2, He, N2 and Ar in accordance with EN1839 method T at high temperatures and at atmospheric pressure. The experimental results show that 1-propanol, 2-propanol and acetone have very similar lower explosion limits (LELs). 1-Butanol shows a slightly wider explosion area near the LEL line. In addition, the explosion regions of all combustible/inert gas/air mixtures were calculated with the method of constant adiabatic flame temperature profiles (CAFTP), using the flame temperature profile along the explosion region boundary curve of each combustible/N2/air mixture as a reference to determine the explosion regions of combustible/inert gas/air mixtures with inert gases other than N2 at different initial temperatures. To calculate the explosion regions for systems containing He, the calculation method was modified to include the very different physical transport properties of He. Moreover, the procedure for calculating the apexes in the ternary explosion diagrams was modified. The calculation results show good agreement with the experimental results.
Explosion and decomposition limits of flammable and chemically unstable gases were determined experimentally in a dosed autoclave with varying ignition energy up to 1000 J. The ignition source was a lightning arc caused by an exploding wire igniter as described in EN 1839 B .. In case of methane only the upper explosion limit was influenced significantly by the ignition energy, whereas the lower explosion limit was constant. In case of R32 however. it was the lower explosion limit that was influenced significantly by the ignition energy and not the upper explosion limit. A particularly strong dependency from the ignition energy was found for the decomposition limits of the chemically unstable gases in nitrogen.
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP. like R134a. are flammable. For evaluating inertization measures for explosion protection. flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide.
Nitrogen and argon were studied experimentally in a closed autoclave
at atmospheric conditions. Furthermore, a calculation method was
adapted to reduce the experimental costs for flammability studies on
these gas mixtures. For igniting R1234yf in the closed autoclave a
newly developed ignition system was used that allows generating
electric arcs with high ignition energy. Gas mixtures containing the
mildly flammable R1234yf and R32 could be inerted by adding much
less inert gas than mixtures containing R1132a, which is more similar
to unfluorinated hydrocarbons regarding the explosion regions. By
using the adapted model of constant adiabatic flame temperature
profiles estimating the explosion limits of fluorinated hydrocarbons
was possible with similar accuracy as for unf luorinated hydrocarbons.
Compressed natural gas (CNG) is a widely used automotive fuel in a variety of countries. In case of a vehicle fire where the safety device also malfunctions, a failure of the CNG automotive cylinder could occur. Such a cylinder failure is associated with severe hazards for the surrounding environment. Firstly, a comprehensive analysis is given below, summarizing various accidents involving CNG automotive cylinders and their consequences. In an extensive experimental program, 21 CNG automotive cylinders with no safety device were tested. Of the 21, burst tests were carried out on 5 Type III and 5 Type IV cylinders. Furthermore, fire tests with 8 Type III and 3 Type IV cylinders were conducted. Apart from cylinder pressure, inner temperature and cylinder mantle temperature, the periphery consequences, such as nearfield blast pressure and fragmentation are documented. The maximum measured overpressure due to a Type III cylinder failure was p = 0.41 bar. Each traceable fragment was georeferenced. All-in-all, fragment throw distances of d > 300 m could be observed. As one key result, it can be stated that the tested Type IV CNG cylinders showed less critical failure behavior then the Type III cylinders under fire impingement.