Filtern
Erscheinungsjahr
- 2015 (13) (entfernen)
Dokumenttyp
- Sonstiges (13) (entfernen)
Referierte Publikation
- nein (13)
Schlagworte
- Biozidanalytik (1)
- Boden (1)
- Classification stem (1)
- Commercially pure iron (1)
- Ductility (1)
- Eignungsprüfung (1)
- Ellipsometrie (1)
- Ellipsometry (1)
- Emissionsmesskammer (1)
- Fluorescence label (1)
- Force controlled TMF testing (1)
- Gesamtcyanid (1)
- Haftfestigkeit (1)
- High-purity iron (1)
- Industrie 4.0 (1)
- Klassifizierungssystem (1)
- Klebfestigkeit (1)
- Ladder sequencing (1)
- MALDI-TOF-MS (1)
- MKW (1)
- Mehr-Proben-Vorbehandeln/Kleben/Prüfen (1)
- Merrifield (1)
- Microarray (1)
- Nano characterization (1)
- Nanomaterial (1)
- Nanoparticle (1)
- OBOC library (1)
- Optical konstantyss (1)
- PAH (1)
- PAK (1)
- Peptide (1)
- Polymer beads (1)
- Proficiency testing (1)
- Prozess-Sensoren (1)
- Prozessanalytik (1)
- Pure iron (1)
- Purity level (1)
- Roadmap (1)
- Round-Robin (1)
- SPPS (1)
- Schwerflüchtige organische Verbindungen (1)
- Sensoren (1)
- Sequencing (1)
- Soil (1)
- Solid-phase peptide synthesis (1)
- Split and mix technology (1)
- Sponsorship programme (1)
- Spurenelemente (1)
- Strain rate (1)
- TPH (1)
- Tensile properties (1)
- Tensile strength (1)
- Tentagel (1)
- Total cyanide (1)
- Trace elements (1)
- Ultra-high-purity iron (1)
- Yield strength (1)
- optische Konstanten (1)
Die Bundesanstalt für Materialforschung und –prüfung (BAM) wurde von der AG 3 der Kommission Lagerung hoch radioaktiver Abfallstoffe gebeten, Anforderungen an Behälter für die Endlagerung hoch radioaktiver Abfallstoffe im Hinblick auf ih-re Rückholbarkeit während des Endlagerbetriebes und ihre Bergbarkeit nach Ver-schluss des Endlagers über einen Zeitraum von 500 (bis 1.000 ?) Jahren darzu-stellen. Die BAM kommt diesem Wunsch auf der Grundlage ihrer langjährigen Er-fahrungen und Fachkenntnisse auf den Gebieten der Bauartprüfung und der si-cherheitstechnischen Begutachtung von Transport- und Lagerbehältern für radio-aktive Stoffe nach.
Ziel dieser Arbeit war die Entwicklung einer Methode zur Hochdurchsatzanalyse von partikelgebundenen Split-and-Mix-Peptidbibliotheken. Dabei wurde ein System entwickelt, das Partikelbibliotheken in kurzer Zeit auf ihre Bindung zu einem Zielmolekül hin untersucht und im nächsten Schritt eine direkte „Ein-Partikel“-Sequenzierung der Peptide von der festen Phase ermöglicht. Die Analyse der Bindung eines Zielmoleküls an ein selektiv bindendes Peptid wurde dabei in einem Modellsystem simuliert. Dazu wurde FITC-markiertes Neutravidin 3 mit festphasengebundenen biotinylierten und nicht-biotinylierten Peptiden inkubiert. Die Bindung von Neutravidin-FITC an die biotinylierten Peptide konnte erfolgreich mittels eines Fluoreszenzmikroskops nachgewiesen werden, wobei diese Methode für eine Hochdurchsatzanalyse ungeeignet war. So wurde die Analyse des Fluoreszenzassays auf einen Microarrayscanner übertragen (siehe Abbildung 33). Dies gelang erfolgreich wobei die hohe Eigenfluoreszenz des Tentagel-Harzes zu falsch positiven Ergebnissen führte. Mit einem Wechsel zum längerwelligen Fluoreszenzfarbstoff ATTO-633 konnten falsch positive Ergebnisse vermieden werden. Somit wurde die zeitintensive Fluoreszenzanalyse von einem Fluoreszenzmikroskop erfolgreich auf einen Microarrayscanner übertragen, welcher in kurzer Zeit (ca. 5 min pro Objektträger) eine Vielzahl an peptidbeladenen Partikeln gleichzeitig analysieren kann.
Die meisten organischen Biozide gehören zu der Gruppe der schwerflüchtigen organischen Verbindungen (SVOC – semi volatile organic compounds). Zu den klassischen Bioziden zählen u.a. Lindan, Pentachlorphenol PCP) und Dichlordiphenyltrichlorethan (DDT) und zu den neueren u.a. Dichlofluanid, Tebuconazol und Permethrin. Biozide kamen in Museen vor allem in den 50er und 60er Jahren zum Schutz der Exponate zum Einsatz,1 wo sie hauptsächlich in Depoträumen zu finden sind, in welchen sie zum akuten und zum präventiven Schutz vor Schadorganismen eingesetzt wurden.2 Im Laufe der Zeit wurde jedoch festgestellt, dass sich der Einsatz von Bioziden negativ auf die menschliche Gesundheit auswirkt und auch zu Schäden an den behandelten Exponaten führen kann. 3 Verschiedene Möglichkeiten der Biozidanalytik und der Einfluss von Senkeneffekten auf die Analytik werden in diesem Beitrag vorgestellt.
The room temperature tensile properties of iron with different purity levels (commercially pure, high-purity, and ultra-high-purity) were characterized at different strain rates in the framework of an international Round-Robin involving four laboratories (BAM, IMR-TU, NIST, and SCKCEN). The test results were collected and analyzed by NIST, and are presented in this Technical Note.
Data from all the participating laboratories were found in good agreement, thus allowing a clear assessment of the influence of strain rate and purity level on tensile properties (mechanical resistance and ductility). A clear increase of yield strength and, to a lesser extent, tensile strength was observed for all materials as strain rate increases and purity level decreases. The highest strain rate sensitivity was associated with the highest purity level (ultra-high-purity Fe). Ductility trends were less unequivocal, but typically an increase of elongation at fracture and reduction of area was detected as strain rate and purity level increase. Significant differences in tensile properties were observed between the two investigated types of high-purity Fe, which can be attributed to an influence of the production process in terms of melting environment (atmosphere and crucible), as well as differences in chemical compositions.
Advanced Mass Spectrometry for Food Safety and Quality provides information on recent advancements made in mass spectrometry-based techniques and their applications in food safety and quality, also covering the major challenges associated with implementing these technologies for more effective identification of unknown compounds, food profiling, or candidate biomarker discovery.
Recent advances in mass spectrometry technologies have uncovered tremendous opportunities for a range of food-related applications. However, the distinctive characteristics of food, such as the wide range of the different components and their extreme complexity present enormous challenges. This text brings together the most recent data on the topic, providing an important resource towards greater food safety and quality.
• Presents critical applications for a sustainable, affordable and safe food supply
• Covers emerging problems in food safety and quality with many specific examples.
• Encompasses the characteristics, advantages, and limitations of mass spectrometry, and the current strategies in method development and validation
• Provides the most recent data on the important topic of food safety and quality
Components in the Aerospace, Power and Automotive engineering sectors are frequently subjected to cyclic stresses induced by thermal fluctuations and mechanical loads. For the design of such components, reliable material property data are required which need to be acquired using well accepted and reproducible test procedures for thermo-mechanical fatigue (TMF) loading. Available materials TMF property data are limited so that there is a need for further TMF data generated by TMF testing. The TMF behaviour of materials is often desired to be simulated in models which describe the cyclic stress-strain behaviour, the fatigue life and the cyclic crack growth behaviour. There is a continuous need for the development and amendment of such models. Models can be validated by using materials in industrial applications which are subjected to TMF loading.
Mit den Technologie-Roadmaps „Prozesssensoren 2005–2015“ [1] (2006) und „Prozesssensoren 2015+“ [2] und [3] (2009) wurden Grundlagen für alle Unternehmen der Prozessindustrie geschaffen, um zielgerichtet auf Kundenbedürfnisse der Prozessindustrie zugeschnittene Produktentwicklungen, technologische Weiterentwicklungen und Forschungsprojekte zum Erfolg zu bringen. Die Roadmap „Prozesssensoren 2015+“ fand große Akzeptanz aufgrund der soliden Betrachtung der Prozesse und der daraus abgeleiteten Thesen. Diese Aussagen haben in vollem Umfang weiterhin Gültigkeit. Im Rückblick auf die damals formulierten Entwicklungsziele wurden viele dieser Ziele im prognostizierten Zeithorizont auf den Weg gebracht und teilweise bereits umgesetzt. In dieser Technologie-Roadmap werden einige Beispiele dazu aufgezeigt.