Filtern
Erscheinungsjahr
- 2011 (28) (entfernen)
Dokumenttyp
- Vortrag (13)
- Beitrag zu einem Tagungsband (10)
- Zeitschriftenartikel (3)
- Posterpräsentation (2)
Schlagworte
- Strain sensor (5)
- Fibre optic sensors (4)
- Monitoring (4)
- Validation (4)
- Structural health monitoring (3)
- Distributed sensor (2)
- Fiber optic sensors (2)
- Geotextiles (2)
- Surface application reliability (2)
- Acoustic wave (1)
Eingeladener Vortrag
- nein (13)
Monitoring of corrosion protection in reinforced concrete structures using an integrated pH optode
(2011)
Corrosion in steel-reinforced concrete structures is a critical issue. Corrosion appears if the pH value of the concrete matrix decreases due to deterioration of the Calcium hydroxide layer on the Steel surface. The safest Information about potential danger of Steel corrosion is the knowledge of the pH value of concrete. The paper presents a Tiber optic pH sensor for long-term monitoring of the pH value of reinforced concrete structures at risk from corrosion. The sensor probe is small (about 8 mm in diameter), can be embedded into the concrete matrix and observe changes in pH over years. Several sensor probes can be staggered to detect the progression of pH decrease. The pH values can be resolved with 0.1 to 0.2 pH value in the ränge between 12.0 and 9.5. The structure of the pH measurement System, longterm test results and the design to achieve stable probes will be explained. Experienee from test applications of pH sensors embedded in grouted anchors and in concrete components for a cooling tower will be presented.
Sensitive partial discharge (PD) measurements on HV/EHV cable systems are usually based on electrical or electromagnetic PD detection. Unfortunately, interferences may significantly reduce sensitivity, especially in on-site after-installation testing and, even more, in on-line PD monitoring. This paper deals with optical PD detection, which is absolutely immune to any kind of electromagnetic interference. Optical PD detection necessarily requires transparent or translucent insulation systems to be applicable. Stress cone elements for HV/EHV cable accessories meet the requirements for optical PD detection, if made from transparent silicone elastomers.
Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented.
FOS standards and methodologies to validate strain measurements with FBG sensors (invited lecture)
(2011)
Reinforced concrete piles are used in case of structures that are constructed on soft ground to transfer the loads into deeper strata with sufficient bearing capacity. In order to determine the pile’s behavior and possible damage, static and dynamic pile tests are carried out. Dynamic measurements taken from the pile head can show the bearing behavior and structural integrity by using the theory of wave propagation. In order to receive more precise information about the pile features, now, a string of sensors is embedded at different levels of the pile. A fiber optic strain wave sensor, based on the extrinsic Fabry-Perot interferometer (EFPI), has already been developed and tested in full-scale field tests by Schallert (2010). It was possible to detect the introduced deformation caused by the static load and the dilatational wave during dynamic loading. Although the full-scale tests were successful, the engineering design of the sensor body left room - from the economical point of view - to be optimized. After laboratory tests with the optimized sensor, a cast-in-situ bored pile has been built at the BAM Test Site Technical Safety in Horstwalde, South of Berlin. Additionally to the EFPI sensors, fiber Bragg grating (FBG) sensors, temperature sensors and resistance strain gauge (RSG) sensors are embedded in order to compare the signals with each other. In this paper, the modified sensor and the Setup of the cast-in-situ bored pile along with results of dynamic tests are shown.
Fibre-optic sensors are more and more used in geotechnical and civil engineering. There are a big number of applications with the purpose of improvement or proof of the structural integrity. This paper, presents two examples where different fibre sensor types.are exploited for safety-relevant task in geotechnique. Technical textiles with embedded distributed fibre-optic sensors based on Brillouin Scattering in silica optical fibres and OTDR (optical time-domain reflectometry) in polymer optical fibres are presented. Such “smart” technical textiles can be used for reinforcement of geotechnical structures and masonry walls, and the embedded fibre-optic sensors can provide information about the condition of the structures as well as detect the presence of any damage and destructions in real time. Highly sensitive fibre-optic geophones based on Fabry-Perot sensors embedded in large concrete pile can be used for precise measurement of Deformation and wave distribution during static and dynamic pile test. Such sensors make the evaluation of the pile’s integrity and load-bearing capacity easier.
How do application-related issues influence the reliability of fiber optic strain measurements?
(2011)
Fibre optic strain sensors are increasingly used and sensor systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor's the performance. The contribution will focus on issues that can deteriorate the sensor function or reduce the reliability of measurement results. Aspects are considered how to come to reliable strain measurements and how to validate strain measurements of applied sensors. Related to this topic, European activities like the recently started European COST TD1001 action, called (OfSeSa) will be presented.
Strain measurement in structures witli the purpose of long-term structurai health inonitoring must provide reliable inforination about the structure’s behavior over the whole period of use. The user must be sure that installed sensors are validated and work to the utmost satisfactiou. For this purpose, sensor Systems are tested using special facilities. Bccause it is not easy to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (= calibration of fiber optic sensors) can also be used for electrical strain sensors.
Calibration ineasurements are referenced by unbinsed Digital Image Correlation (D1C) and Electronic Speckle Pattern Interferometer (ESPI) methods. The strain transfer behavior can experimentally be analyzed and investigated under combined thermal and mechanical loading conditions and allows revealing wealuiesses in couimonly used attachment methodologies. The deformation of all members (particularly the coating/substrate - adhesive combination) in the sensing area is physically independently gained and recorded. Results achievcd allow precise description of the strain transfer function, Validation of the longterm strain sensor characteristics, matching of specific measurement requirements with environmental conditions, and, moreover, the verification of Standards for use of strain sensors.
Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions.