Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (22)
- Vortrag (6)
- Zeitschriftenartikel (3)
- Posterpräsentation (1)
Schlagworte
- Simulation (32) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (6)
The new standard ISO 176362:2013 'NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors' describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636-2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 116991 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SRb) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise.
One essential step on the way towards accurate quantitative simulation of radiographic testing is an accurate description of the utilized energy spectrum of X-ray photons. For use in general purpose simulation tools, the spectra of X-ray tubes have to be described by a model covering at least the intended range of applications. This range includes transmission tubes as well as direct beam tubes with varying angles of incidence and emission, for a number of typical target materials. In radiographic testing acceleration voltages frequently reach up to 450 kV for direct beam targets and up to 225 kV for transmission targets, with even higher voltages available or being developed. Currently used models are unable to cover the whole range of configurations.
Here a model is presented that employs a unified approach for simulating the photon energy spectra for transmission and direct beam targets composed of arbi-trary homogeneous materials. In order to achieve this, a detailed model of electron transport within the target is employed. The validity of the developed model is shown through comparisons with Monte Carlo simulations as well as measurements for a number of different configurations.
A model is presented that employs a unified approach for
simulating the photon energy spectra for transmission and direct
beam targets composed of arbitrary homogeneous materials. In order
to achieve this, a detailed model of electron transport within the
target is employed. The validity of the developed model is shown
through comparisons with Monte Carlo simulations as well as
measurements for a number of different configurations.
Industrial radiography or Radiographic Testing (RT) is a method of non-destructive testing where many types of manufactured components can be examined to verify the internal structure and integrity of the specimen. The computer program aRTist can generate synthetic radiographs from a virtual RT test set-up. In the field of industrial radiology simulation is used, e.g. to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes.
The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport. The program comes with a graphical user interface written in Tcl/Tk. In combination of Tcl/Tk and the 3D capabilities of the visualization toolkit (VTK) a practical and convenient simulator has been realized. This will be illustrated by discussing application scenarios of classical radiography, X-ray computer tomography, and X-ray backscatter imaging. Additionally, some insight to the software implementation of the simulator will be given.
The interest in using computer simulations of dimensional x-ray computed tomography (dXCT) for various metrological purposes—such as measurement planning, performance prediction, performance optimisation and, finally, measurement uncertainty estimation—is increasing along with the ever-growing demand for more reliable measurements with dXCT. However, before a piece of simulation software can be used for tasks related to coordinate metrology, it has to be ensured that it is able to simulate physical laws, characteristic effects and basic CT system functionalities correctly and with sufficient accuracy. In short, the software must be qualified for dimensional metrology tasks. As one part of such a qualification process, a method is presented here for determining conformity intervals of 2D tests (projection-based tests) based on 3D tests (testing based on dimensional evaluations in a reconstructed volume) for the assessment of dXCT simulation software. The method consists of varying relevant parameter values in order to verify their influence on 3D measurement results. The results of the 3D tests with varied parameter values are then transferred to the quantities tested in the 2D tests and used as the basis for determining conformity intervals. Two approaches are applied for determining whether or not a variation of a parameter value is significant: (a) statistical and (b) heuristic. Two examples are presented, each based on simulated images, which show the application of the two different approaches for determining conformity intervals for the results of the 2D tests.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we focus on Monte Carlo simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.