Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (87) (entfernen)
Sprache
- Englisch (67)
- Deutsch (19)
- Mehrsprachig (1)
Schlagworte
- Simulation (87) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (11)
- 8.5 Röntgenbildgebung (5)
- 8.4 Akustische und elektromagnetische Verfahren (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 3.4 Sicherheit von Lagerbehältern (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 4 Material und Umwelt (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".
It is common practice in the application of finite element analysis to model compression set (CS) of elastomers during aging with two different material models according to the two-network theory of Tobolsky. The theory relies on the existence of two networks. The first one represents the original network after vulcanization and is sensitive to chain scission. The second network accounts for the formation of additional crosslinking during aging. Besides the use of user subroutines to describe the two-network model, an element overlay technique is also needed as the full set of both material behaviors did not exist for assignment to a single element. This element overlay technique is valuable for research and developmental purposes but makes extension to industrial usage quite challenging. Our goal is to simulate the CS of elastomers after long-term aging in a commercial finite element software with no need for extra subroutine codes or mesh superposition.
Ethylene propylene diene (EPDM) O-rings were aged in a compressed state at 75 °C, 100 °C, 125 °C and 150 °C for up to 183 days. Investigations of the experimental test results were used to identify material models and their parameters to develop a finite element model to simulate CS. The model was implemented in the finite element software ABAQUS/Standard® with a sequential temperature-displacement coupling.
Regarding the influence of temperature, the Arrhenius equation is adopted for the time-temperature relationship. The activation energy value that is required for the simulation is firstly determined from shifting the experimental CS results with the time-temperature superposition technique and plotting the shift factors in an Arrhenius diagram. The experiments were compared with the simulation results. Afterwards different activation energies were used in the simulation and discussed. A suitable choice of the activation energy value with regard to the reference temperature and the test temperature is presented. With the chosen activation energies, the match between numerical CS values after long-term aging and the experimental results was improved.
Muon tomography applied to assessment of concrete structures: First experiments and simulations.
(2022)
Non-destructive techniques for reinforced or prestressed concrete inspection such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and
accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques.
However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened new fields of application. As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. In a second step, we have performed simulations to assess the potential for a set of important testing problems such as grouting defects in tendon ducts. The next steps include the development of mobile detectors and optimizing acquisition and imaging parameters.
Seit beinahe 50 Jahren werden Zuverlässigkeitsbewertungen zerstörungsfreier Prüfverfahren erfolgreich in unterschiedlichen Industriebranchen eingesetzt. Dennoch gibt es weiterhin viele Vorbehalte, da die Bewertungsgrundlage nicht standardisiert ist und konkrete Handlungsanweisungen fehlen. Dem gegenüber steht die Anerkennung in der ZfP-Community. Es ist bisher nur Wenigen bekannt, dass dem Wissen über die Zuverlässigkeit eines zerstörungsfreien Prüfverfahren eineSchlüsselfunktion für die ZfP 4.0 zukommt.
Im Vortrag wird die Notwendigkeit für eine Norm oder eine Richtlinie zum Thema Zuverlässigkeitsbewertungen aufgezeigt. Es wird darauf eingegangen, warum es bisher (in Deutschland) noch keine Richtlinie gab und gibt und was der:die Anwender:innen aus einer Richtlinie zur Zuverlässigkeitsbewertung von ZfP-Prüfverfahren erwarten kann.
Es werden konkrete Schritte und Vorgehensweisen zur Bewertung der Zuverlässigkeit eines Verfahrens aufgezeigt; von der Definition eines Anwendungsfalls, über die Herstellung geeigneter Testkörper bis hin zur Durchführung und Bewertung von Prüfungen unter Einbeziehung von menschlichen Einflüssen. Die Beispiele umfassen sowohl Anwendungen aus dem Bauwesen als auch aus dem Maschinen- und Anlagenbau.
Der Vortrag fasst die bisherigen und geplanten Arbeiten in dem WIPANO Projekt „Normung für die probabilistische Bewertung der Zuverlässigkeit für zerstörungsfreie Prüfverfahren“ zusammen.
Zur Simulation des Schallfeldes von beliebig geformten konventionellen Schallquellen existieren viele Ansätze (EFIT, GPSS). Sie alle basieren auf der Annahme eines monochromatischen akustischen Signals, was meist eine gültige Annäherung darstellt. Allerdings sind bei thermoakustischen Quellen aufgrund ihrer Funktionsweise und der hohen Bandbreite viele der existierenden Ansätze nicht direkt anwendbar und können Beobachtungen bei der Vermessung von thermoakustischen Wandlern nicht vollständig abbilden und erklären.
In diesem Beitrag wurde die bekannte Methode der generalisierten Punktquellensynthese (GPSS) für die Berechnung von Schallfeldern von thermoakustischen Schallquellen angewendet. Dabei gehen zahlreiche Parameter wie die Dicke und Geometrie der leitfähigen Schicht, Krümmung des Substrats, sowie die Signalform der Anregung in die Simulation ein. Neu an dem präsentierten Ansatz ist die Abweichung von der üblichen monochromatischen Annäherung und die Berücksichtigung der großen Bandbreite von thermoakustischen Wandlern. Für die Validierung der Simulationen wurden Schallfelder von Quellen mit bekannter Anregung und Geometrie breitbandig durch ein optisches Mikrofon vermessen.
Enhanced photon upconversion using erbium-doped nanoparticles interacting with silicon metasurfaces
(2021)
Photon upconversion (UC) using trivalent erbium (Er+3) doped crystals is a promising concept to harness near infrared photons of the solar spectrum which cannot be directly absorbed by silicon solar cells. However, their UC efficiency at low-intensity 1 sun illumination is not relevant on device level so far. Exploiting giant near-field enhancement effects on metasurfaces is an appealing approach to enable efficient UC at low irradiance conditions. Here, we report on more than 1000-fold enhanced photon UC of NaYF4:Er+3 nanoparticles interacting with the near-fields supported by a silicon metasurface under 1550 nm excitation.
The best-known discretization methods for solving engineering problems formulated as partial differential equations are finite difference method (FDM), finite element method (FEM) and finite volume method (FVM). While the finite volume method is used in fluid mechanics, the finite element method is predominant in solid state mechanics. At first glance, FVM and FEM are two highly specialized methods. However, both methods can solve problems of both solid mechanics and fluid mechanics well. Since experimental mechanics deals not only with solid state physics but also with fluid mechanics problems, we want to understand FVM in the sense of FEM in this work. In the long term, we want to use the variational calculus to unify many important numerical methods in engineering science into a common framework. In this way, we expect that experiences can be better exchanged between different engineering sciences and thus innovations in the field of experimental mechanics can be advanced. But in this work, we limit ourselves to the understanding of the FVM with the help of the variational calculus already known in FEM. We use a simple 1D Poisson equation to clarify the point. First, we briefly summarize the FVM and FEM. Then we will deal with the actual topic of this paper, as we establish the FEM and the FVM on a common basis by variation formulation. It is shown here that the FVM can be understood in terms of the finite element method with the so-called Galerkin-Petrov approach.
Radiografische Simulationswerkzeuge wie aRTist, ScorpiusXLab, SimCT oder CIVA CT verwenden analytische Methoden und physikalische Monte-Carlo-Teilchentransportsimulationen, um die Interaktionsprozesse zwischen Röntgenstrahlung und Materie zu simulieren. Die berechneten Projektionen bilden anschließend unter Berücksichtigung einer definierten Scan-Trajektorie die Basis der Simulation einer röntgencomputertomografischen Untersuchung.
Für den erfolgreichen Einsatz der Computertomografie, sei es als zerstörungsfreie Prüfmethode oder beim dimensionellen Messen, ist es generell notwendig, bekannte Fehler- bzw. Abweichungsquellen des Messverfahrens auszuschließen oder zu reduzieren. Dabei hat sich gezeigt, dass die Auswahl der Messparameter und die Erfahrung des Anwenders direkten Einfluss auf das erzielbare Messergebnis einer computertomografischen Untersuchung nehmen. Es ist daher sinnvoll, die Parameterauswahl in einem virtuellen Simulationsaufbau vorher zu erproben und an die Messaufgabe anzupassen.
Neben der Optimierung von Messparametern finden radiografische Simulationswerkzeuge auch Anwendung für Machbarkeitsstudien und werden zur Schulung von Anwendern im Bereich der Röntgen-Computertomografie verwendet.
Radiografische Simulationswerkzeuge befinden sich in einem stetigen Wandel, beispielsweise durch die Entwicklung neuer Rekonstruktionsmethoden, durch Erweiterung von analytischen Modellen, durch Integration komplexer Trajektorien oder durch Berücksichtigung von prozessbedingten geometrischen Abweichungen. Im laufenden EMPIR-Projekt „AdvanCT“ entsteht deshalb ein „Good Practice Guide“ für die Simulationsumgebung aRTist. Ziel dieses Guides ist es, die mit steigender Komplexität verbundenen Einstiegshürden für Anwender von aRTist zu reduzieren, um damit einen praxisnahen Zugang zur virtuellen Computertomografie zu ermöglichen. Dabei werden anhand von praktisch nachvollziehbaren Beispielen die grundlegenden Mechanismen der Simulationsumgebung erklärt und ein strukturierter Leitfaden zur Simulation röntgencomputertomografischer Untersuchungen mit aRTist vermittelt.
In diesem Beitrag werden erste Auszüge des Guides sowie eine Übersicht der weiteren geplanten Themen für die anschließende Diskussion vorgestellt.
Die industrielle Röntgen-Computertomografie (CT) etabliert sich für die Anwendung in der dimensionellen Messtechnik. Sie bietet als zerstörungsfreies Messverfahren das Potential, sowohl innen- als auch außenliegende Merkmale holistisch zu erfassen. Für die Bestimmung der Güte eines Messwerts muss die dem Messwert zugeordnete Messunsicherheit ermittelt werden. Dabei kann, nach derzeitigem Stand der Technik und Normung, die aufgabenspezifische Messunsicherheit nach VDI/VDE 2630 Blatt 2.1 nur unter hohem Aufwand mit einer Vielzahl an experimentellen Wiederholmessungen ermittelt werden. Ziel diverser Forschungs-projekte zu diesem Thema ist es daher, eine numerische Messunsicherheitsbestimmung zu erreichen. Dafür ist es notwendig, alle signifikanten Einflussgrößen zu erfassen, deren Unsicherheitsbeiträge zu bestimmen und zu bewerten. In diesem Beitrag wird der Einfluss des Bildrauschens auf verschiedene dimensionelle Messgrößen simulativ untersucht. Mithilfe eines prismatischen Prüfkörpers, der eine Vielzahl an Geometrieelementen aufweist, werden verschiedene Messgrößen unterschiedlicher Komplexität betrachtet. Ziel ist es, für diese Messgrößen zu testen, wie diese auf das Bildrauschen reagieren. Dieses wird dabei durch das Signal-Rausch-Verhältnis (SNR) der Projektionsgrauwerte beschrieben und variiert. Es werden Wiederholsimulationen durchgeführt, damit eine statistische Aussage über die Verteilung der Messwerte möglich ist und der Einfluss des Rauschens auf verschiedene Messgrößen individuell beurteilt werden kann. Das Simulationsszenario wird so gestaltet, dass lediglich das Bildrauschen Einfluss auf die Messung hat. Die berechneten Verteilungsbreiten lassen mit sinkendem SNR eine deutliche Zunahme erkennen, insbesondere bei der Bestimmung von Formabweichungen. Simuliert wird mit der Software aRTist 2.10 (BAM).
Elastomer seals are used in many industrial applications due to their excellent mechanical properties at a wide range of temperatures. Their high versatility and recovery potential under several load conditions make them well suitable for the application in containers designed for transport, storage and/or disposal of radioactive materials. In containers for low and intermediate level radioactive waste, elastomer seals are used as barrier seals, and as auxiliary seals in storage and transportation casks (dual purpose casks) for heat generating radioactive waste, such as spent fuel and high-level waste. While a seal exchange at defined intervals is typical in many conventional applications, it is impossible or at least hard to perform when principles of minimization of radiation exposure have to be considered and prohibit an unnecessary cask handling. An extensive knowledge of the change of the elastomer’s properties during aging and the availability of reliable end-of-lifetime criteria to guarantee the permanent safe enclosure of the radioactive material is mandatory. As BAM is involved in most of the national cask licensing procedures and in the evaluation of cask-related long-term safety issues, great efforts have been already made and are still planned to scientifically support this task.
Compression stress relaxation and compression set were identified as key indicators of elastomer long-term performance and quantitatively investigated in comprehensive test programs. Among other representative types of elastomers, specimens made from ethylene propylene diene rubber (EPDM) were tested before, during and after aging to capture the most important of their complex mechanical properties.
In the presented study, exemplary results were used to simulate the compression stress relaxation and the compression set of elastomer O-rings during aging. Regarding the influence of temperature, the time-temperature superposition principle is applied in the relaxation analysis of elastomer O-rings. The proposed model is implemented in the commercial finite element software ABAQUS/Standard® [1] with a sequential temperature displacement coupling. Numerical results match the experimental compression stress relaxation measurements well. The prediction of compression set values after long-term aging shows a relatively good agreement with the experimental results. Nevertheless, all input parameters derived from the specimen tests, additional assumptions concerning boundary conditions and modeling strategy are discussed with regard to the identified slight discrepancies.
The possibility to extend the finite element model to represent the O-ring seal’s ability to recover after a (fast) partial release is taken into account.