Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (138)
- Vortrag (99)
- Posterpräsentation (56)
- Forschungsdatensatz (9)
- Beitrag zu einem Sammelband (8)
- Beitrag zu einem Tagungsband (7)
- Sonstiges (6)
- Forschungsbericht (6)
- Handbuch (4)
- Sammelband (Herausgeberschaft für den kompletten Band) (2)
Schlagworte
- Nanoparticles (339) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (176)
- 6.1 Oberflächen- und Dünnschichtanalyse (140)
- 1 Analytische Chemie; Referenzmaterialien (38)
- 6.3 Strukturanalytik (20)
- 1.2 Biophotonik (19)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (17)
- 5 Werkstofftechnik (12)
- 6.6 Physik und chemische Analytik der Polymere (10)
- 1.1 Anorganische Spurenanalytik (9)
- 1.0 Abteilungsleitung und andere (5)
- 5.1 Mikrostruktur Design und Degradation (5)
- 7 Bauwerkssicherheit (5)
- 1.8 Umweltanalytik (4)
- 1.9 Chemische und optische Sensorik (4)
- 4 Material und Umwelt (4)
- 5.4 Multimateriale Fertigungsprozesse (4)
- 6.0 Abteilungsleitung und andere (4)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (4)
- 1.4 Prozessanalytik (3)
- 1.5 Proteinanalytik (3)
- 4.1 Biologische Materialschädigung und Referenzorganismen (3)
- 6.7 Materialsynthese und Design (3)
- 5.6 Glas (2)
- 1.6 Anorganische Referenzmaterialien (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5.5 Materialmodellierung (1)
- 7.1 Baustoffe (1)
- 7.4 Baustofftechnologie (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
- P Präsident (1)
- P.0 Präsident und andere (1)
Paper des Monats
- ja (2)
Following points are addressed in this contribution: Advantages of correlative analysis in electron microscopy; Measurement principle of the different electron microscopy modes used; Presentation of the nanomaterials used for this study; Role of sample preparation; and, with particular description, the Sequence kV-variation with InLens SE & transmission SEM detection of the same field-of-view.
A lack of harmonised terminology hinders accurate description of many nano-object properties. An overview on nanoscale reference materials for environmental , health and safety measurements has been provided by Stefaniak et al. Since then several nanoscale reference materials were produced as finely dispersed nanoparticles, including catalytic active silver nanoparticles and iron oxide nanocubes. Polymeric nanoparticles made of polypropylene (PP), polyethylene (PE) and poly(ethylene terephthalate) (PET) are ongoing reference materials projects. A first study on PP has shown that mechanical breakdown of macroscopic PP towards nano PP is possible. Hereby the nano PP is stabilized by a strongly negative zeta potential of – 44 mV. This provides a long-term stability of the nanoparticles at ambient conditions in cases of low ionic strength. Since this nano PP has no added colloidal stabilizers, we suggest this as a potential reference materials candidate for reliable determination PP nanoplastics. Moreover, the nano PP may function as a reference for the estimation of possible toxic effects of nanoplastics. Efforts in producing nano PP labeled with ultra-small gold nanoparticles are reported.
The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM).
For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary.
The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM.
With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically).
❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility.
❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs.
❑ Selection of the threshold algorithm can significantly alter the reported ECD.
Traceable morphological and chemical characterization of nanomaterials with respect to the various possible sizes, size distributions, shapes, and concentrations of real-world nanoparticles (NPs) is a challenging task. Particularly for the nonspherical, non-monodisperse nanoparticles – as typically for most of the commercial particles, including their strong tendency to agglomerate, there is a lack of standard operation procedures providing accurate nanoparticle characterisation.
In the framework of the pre-standardisation framework of VAMAS (Versailles Project on Advanced Materials and Standards, www.vamas.org) two interlaboratory comparison (ILC) studies are being carried out under the Technical Working Area (TWA) 34 “Nanoparticle Populations”:i) Project #15 addresses the analysis of the size and shape distribution of TiO2 bipyramidal NPs by traceable imaging methods such as TEM, SEM, STEM-in-SEM, AFM as well as with SAXS as an ensemble method. This ILC is thought as the next level development of the case studies exemplified in the published ISO standards ISO 21363 and ISO 19749. It was agreed to complete the first ILC with the NPs already prepared according to the same procedure on a TEM grid, and, at a later stage, to carry out second ILCs with the same NPs distributed to the participants as liquid suspensions together with protocols for the uniform NP deposition on suited substrates - as developed and optimized within the European project nPSize. Once having good deposition protocols available, the door for automated image analysis gets opened. Corresponding image analysis protocols and reporting templates have been distributed to the ILC participants, too.
ii) Project #16: two spherical SiO2 NP samples with bi-modal size distributions in two nominal relative number concentrations were prepared and distributed also as liquid suspensions accompanied by sample preparation, measurement, and image analysis protocols and reporting templates. Here, the NP concentration is the primary parameter to be measured. For the imaging methods it is targeted to
measure the relative nanoparticle concentrations (relative populations of the two modes).
The results of all the participating laboratories, in both ILCs, compiled in comparative representations will be shown and discussed for the first time. The reduction of the measurement uncertainties associated to the size, shape and number-concentration results induced by the significant improvement of the sample preparation on substrates (as single particles with a high-density coverage), combined with well-defined image analysis procedures will be highlighted.
Finally, a very recent 3rd ILC an the determination of lateral size of Graphene Oxide flakes by SEM is presented as project P13 under VAMAS TWA41 Graphene and Related 2D.
The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM).
For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary.
The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM.
With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically).
❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility.
❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs.
❑ Selection of the threshold algorithm can significantly alter the reported ECD.
In this lecture, following points are addressed:
– Advantages of correlative analysis in electron microscopy
– Measurement principle of the different electron microscopy modes used
– Presentation of the nanomaterials used for this study
– Role of sample preparation
– Sequence kV variation with InLens & transmission detection of the same field-of-view
– Conclusive remarks including Monte Carlo simulations
An overview with the basics of size and shape measurement of particles and 2D structures according to established methodologies (and popular imaging processing software packages) with imaging techniques is given. Main descriptors are explained based on practical cases are determined interactively at the flipchart.
Traceable morphological and chemical characterization of nanomaterials with respect to the various possible sizes, size distributions, shapes, and concentrations of real-world nanoparticles (NPs) is a challenging task. Particularly for the nonspherical, non-monodisperse nanoparticles – as typically for most of the commercial particles, including their strong tendency to agglomerate, there is a lack of standard operation procedures providing accurate nanoparticle characterisation.
In the framework of the pre-standardisation framework of VAMAS (Versailles Project on Advanced Materials and Standards, www.vamas.org) two interlaboratory comparison (ILC) studies are being carried out under the Technical Working Area (TWA) 34 “Nanoparticle Populations”:i) Project #15 addresses the analysis of the size and shape distribution of TiO2 bipyramidal NPs by traceable imaging methods such as TEM, SEM, STEM-in-SEM, AFM as well as with SAXS as an ensemble method. This ILC is thought as the next level development of the case studies exemplified in the published ISO standards ISO 21363 and ISO 19749. It was agreed to complete the first ILC with the NPs already prepared according to the same procedure on a TEM grid, and, at a later stage, to carry out second ILCs with the same NPs distributed to the participants as liquid suspensions together with protocols for the uniform NP deposition on suited substrates - as developed and optimized within the European project nPSize. Once having good deposition protocols available, the door for automated image analysis gets opened. Corresponding image analysis protocols and reporting templates have been distributed to the ILC participants, too.
ii) Project #16: two spherical SiO2 NP samples with bi-modal size distributions in two nominal relative number concentrations were prepared and distributed also as liquid suspensions accompanied by sample preparation, measurement, and image analysis protocols and reporting templates. Here, the NP concentration is the primary parameter to be measured. For the imaging methods it is targeted to
measure the relative nanoparticle concentrations (relative populations of the two modes).
The results of all the participating laboratories, in both ILCs, compiled in comparative representations will be shown and discussed for the first time. The reduction of the measurement uncertainties associated to the size, shape and number-concentration results induced by the significant improvement of the sample preparation on substrates (as single particles with a high-density coverage), combined with welldefined image analysis procedures will be highlighted.
Electron microscopy applied in different operating modes, e.g., SEM, TEM or STEM-in-SEM, is the gold standard method to investigate the exact size and shape of individual nanoparticles. However, when fine nanoparticles with a non-monodisperse size distribution and non-spherical shapes are analysed, achieving an accurate result is challenging. Deviations in size measurements of more than 10% may occur. Understanding of the contrasts and sensitivities characteristic to the individual operating modes of an electron microscope is key in interpreting and evaluating quantitatively the measurement uncertainties needed for an eventual certification of specific nanoparticles via traceable results. Further, beyond the pure measurement, the other components in the analysis workflow with significant impact on the overall measurement uncertainties are the sample preparation and the image segmentation. In the present study the same areas of selected iron oxide fine nanoparticles (<25 nm) as reference nanomaterial (candidate) prepared on substrate for electron microscopy imaging are analysed correlatively with SEM, STEM-in-SEM and TEM with respect to their size and shape distribution. Individual significant measurement uncertainties are discussed, e.g., the sensitivity of secondary electron detectors of InLens-type to the surface morphology, particularly to the presence of an ultrathin organic coating or signal saturation effects on the particle edges, to electron beam exposure, to surface contamination, or the selection of the threshold for image segmentation. Another goal of this study is to establish a basis of analysis conditions which shall guarantee accurate results when both manual and particularly (semi-)automated segmentation approaches are applied. Advantages as well as limitations of the use of different electron microscopy operating modes, applied individually and correlatively, are highlighted.
The research carried out at the Laboratory of Spectroscopy of Functional Materials at IFSC/USP, in Brazil, is focused on the synthesis and structural-property correlation of luminescent materials including rare-earth (RE) doped glasses, ceramics and hybrid host-guest materials. For the past five years, we have been particularly interested in the development of single- and multifunctional nanosystems based on core-shell upconversion nanoparticles (UCNP) associated with dyes, organometallic complexes and other organic molecules, for biophotonic and sensing applications. In these systems, we take advantage of energy transfer between the UCNPs and the molecules to either supress or enhance luminescent response. Examples include the possibility of bioimaging and photodynamic therapy of bacteria and cancer cells, simultaneous magnetothermia and thermometry, localized O2 sensing, fast detection and quantification of biological markers (e.g. kidney disease) and microorganisms. On what concerns the development of luminescent sensors - a recently started project, our aim is to develop paper-based platforms for point-of-care devices. In this presentation, an overview of our contributions for the past years and our future aims will be presented with several examples.